ADTRAN-GEN-FRAME-RELAY-MIB

DEFINITIONS ::= BEGIN

    -- ******************************************************************
    -- TITLE:     ADTRAN GEN FRAME RELAY CLIENT MIB
    -- DATE:      September 9, 2010
    --
    -- HISTORY:
    -- yy/mm/dd
    -- 2010/03/24 cb STATUS: PRELIMINARY.
	-- 2010/03/29 jlb - Changed adGenFrameRelayId to adGenFrameRelayID.
	--					adGenFrameRelay and adGenFrameRelayID are now imported from adGenCndSystem.
	-- 2010/04/30 cb  - Added adGenFrPVCOperStatus and adGenFrPVCLastChange.  Corrected enumerated
	--                  values for adGenFrPVCState.
	-- 2010/05/03 cb  - Changed read-write types to read-create and moved previous scalars
	--                  for Group and PVC information to appropriate slot tables and the
	--                  adFrGroupTable.
	-- 2010/06/25 na  - Added PM intervals for groups and PVCs
	-- 2010/09/02 cb  - Removed adGenFrPVC* oids related to secondary IP gateway
	--                  address and primary and secondary gateway subnet masks
	-- 2010/09/09 cb  - Added adGenFrPVCDescription and adGenFrPVCMtu
	-- 2010/09/30 glf - correct varbinds in the adGenFrGroupDownAlarmClr, add ifOperStatus so varbinds will 
	--                  match the adGenFrGroupDownAlarmAct alarm

    -- ******************************************************************

    IMPORTS
        MODULE-IDENTITY,
        OBJECT-TYPE,
        NOTIFICATION-TYPE,
        Integer32,
        Counter32,
        TimeTicks,
        Unsigned32               FROM SNMPv2-SMI    -- [RFC2578]
        sysName                  FROM SNMPv2-MIB
        RowStatus,
        TruthValue,
        DisplayString            FROM SNMPv2-TC     -- [RFC2579]
        InterfaceIndex,
        ifIndex,
        ifOperStatus             FROM IF-MIB        -- [RFC2863]
        MODULE-COMPLIANCE,
        OBJECT-GROUP,
        NOTIFICATION-GROUP       FROM SNMPv2-CONF   -- [RFC2580]
        InetAddressType,
        InetAddress              FROM INET-ADDRESS-MIB  -- [RFC2851]
        adGenFrameRelay,
        adGenFrameRelayID        FROM ADTRAN-SHARED-CND-SYSTEM-MIB
        adTrapInformSeqNum       FROM ADTRAN-GENTRAPINFORM-MIB
        adTAeSCUTrapAlarmLevel   FROM ADTRAN-TAeSCUEXT1-MIB
        adGenPortTrapIdentifier  FROM ADTRAN-GENPORT-MIB
        adGenSlotInfoIndex       FROM ADTRAN-GENSLOT-MIB
        ;

    adGenFrameRelayMib   MODULE-IDENTITY
        LAST-UPDATED "201009090000Z"    -- 9/9/2010 00:00GMT
        ORGANIZATION "ADTRAN"
        CONTACT-INFO
           "WG-URL:
            WG-EMail: http://www.adtran.com

            Contact:  ADTRAN
                      901 Explorer Blvd
                      Huntsville, AL 35806

            E-mail:

           "
       DESCRIPTION
         "ADTRAN Generic Frame Relay Management Module"

       REVISION "201009090000Z"    -- 9/9/2010 00:00GMT
       DESCRIPTION
		  "cb  - Added adGenFrPVCDescription and adGenFrPVCMtu"

       REVISION "201009020000Z"    -- 9/2/2010 00:00GMT
       DESCRIPTION
		  "cb  - Removed adGenFrPVC* oids related to secondary IP gateway
		         address and primary and secondary gateway subnet masks"

       REVISION "201006250000Z"    -- 6/25/2010 00:00GMT
       DESCRIPTION
		  "na  - Added PM intervals for groups and PVCs."

       REVISION "201005030000Z"    -- 5/3/2010 00:00GMT
       DESCRIPTION
		  "cb  - Changed read-write types to read-create and moved previous scalars
	             for Group and PVC information to appropriate slot tables and the
	             adFrGroupTable."

       REVISION "201004300000Z"    -- 4/30/2010 00:00GMT
       DESCRIPTION
		  "cb  - Added adGenFrPVCOperStatus and adGenFrPVCLastChange.  Corrected enumerated
	             values for adGenFrPVCState."

       REVISION "201003290000Z"    -- 3/29/2010 00:00GMT
       DESCRIPTION
		  "jlb - Changed adGenFrameRelayId to adGenFrameRelayID.
			 	 adGenFrameRelay and adGenFrameRelayID are now imported from adGenCndSystem."

       REVISION "201003240000Z"    -- 3/24/2010 00:00GMT
       DESCRIPTION
          ""
         ::= { adGenFrameRelayID 1 }

    adGenFrameRelayMIBObjects      OBJECT IDENTIFIER  ::= { adGenFrameRelay 1 }

    -- ******************************************************************
    -- Tables
    -- ******************************************************************

    adGenFrGroup        OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 1 }
    adGenFrLink         OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 2 }
    adGenFrPVC          OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 3 }
    adGenFrSlot         OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 4 }

    adGenFrAlarmsPrefix OBJECT IDENTIFIER ::= {adGenFrameRelay 2 }
    adGenFrAlarms       OBJECT IDENTIFIER ::= {adGenFrAlarmsPrefix 0 }

    -- ******************************************************************
    -- Textual conventions
    -- ******************************************************************

    -- ******************************************************************
    -- The Frame Relay Group Provisioning Table
    -- ******************************************************************
    
    adGenFrGroupTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrGroupEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This table provides provisioning and status information
                     on all frame relay groups / bearer channels."
         ::= { adGenFrGroup 2 }

    adGenFrGroupEntry OBJECT-TYPE
        SYNTAX      AdGenFrGroupEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The Frame Relay Group provisioning and status table entry.  To
                     create a frame relay group, the following procedures are used:

                     (1) The management application creates Frame Relay Group
                         entry in the adGenFrGroupTable by setting the
                         adGenFrGroupRowStatus to createAndWait(5).

                         This may fail for the following reasons which are reported
                         through the adGenFrSlotGroupLastCreateError object:

                         - The selected ifIndex specifies an invalid interface
                         - The selected ifIndex is already in use by another Frame
                           Relay Group

                         Otherwise, upon successful creation of the row, the group
                         is reserved and a corresponding row (identical ifIndex)
                         in the frMgtVcSigTable is created.

                     (2) The manager sets other provisioning rows in the
                         adGenFrGroupTable and the frMgtVCSigTable that are
                         appropriate for the service that is to be provided.

                     (3) Connect a frame relay link to the group to specify which
                         interface is to provide service to the group.  See the
                         adGenFrLinkTable description for more information.

                     (4) If no detectable errors or conflicts in the group
                         provisioning is detected, the adGenFrSlotGroupLastCreateError
                         object will contain an empty (zero length) string and
                         and can be enabled by setting adGenFrGroupRowStatus to active(1).
                         
                     (*) Signaling errors (if enabled) and any provisioning failures
                         after setting the adGenFrGroupRowStatus to active(1) can be
                         detected by examining the ifTable's ifOperStatus object.  If
                         this value is not up(1), the adGenFrSlotGroupLastCreateError
                         object will contain further diagnostic information as to the
                         cause of any failure.
                     "
        INDEX       { ifIndex }
         ::= { adGenFrGroupTable 1 }

    AdGenFrGroupEntry ::= SEQUENCE {
          adGenFrGroupRowStatus            RowStatus,
          adGenFrGroupStatusString         DisplayString,
          adGenFrGroupAdminStatus          INTEGER,
          adGenFrGroupLmiType              INTEGER,
          adGenFrGroupLmiStatus            INTEGER,
          adGenFrGroupLmiEnquiryIn         Counter32,
          adGenFrGroupLmiEnquiryOut        Counter32,
          adGenFrGroupLmiStatusIn          Counter32,
          adGenFrGroupLmiStatusOut         Counter32,
          adGenFrGroupLmiInvalidIn         Counter32,
          adGenFrGroupLmiStatusEnqTimeouts Counter32,
          adGenFrGroupLmiStatusTimeouts    Counter32,
          adGenFrGroupClearCounters        INTEGER,
          adGenFrGroupClearPmHistory       INTEGER,
          adGenFrGroupLinkLastCreateError  DisplayString,
          adGenFrGroupPvcLastCreateError   DisplayString
       }

    adGenFrGroupRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The adGenFrGroupRowStatus object allows create, change, and
                     delete operations on the Frame Relay Group / Bearer Channel."
         ::= { adGenFrGroupEntry 1 }

    adGenFrGroupStatusString OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason, if any, why the why the group is not in an
                     operational state due to provisioning or hardware limitations."
         ::= { adGenFrGroupEntry 2 }
         
    adGenFrGroupAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                              up(1),
                              down(2),
                              testing(3)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The desired state of the frame relay group.  This object
                     must be set to up(1) or testing(3) to enable user data
                     transmission on PVCs of this group and for enabling of
                     any signaling protocol for this group."
        DEFVAL      { down }
        ::= { adGenFrGroupEntry 3 }

    adGenFrGroupLmiType OBJECT-TYPE
        SYNTAX      INTEGER {
                              none(1),        -- No signaling
                              ansi617d1994(3) -- ANSI T1.617a-1994 Annex D
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The value of this object identifies the local in-channel signaling
                     protocol that is used for this frame relay UNI/NNI logical port."
        REFERENCE   "American National Standard T1.617-1991, American National Standard
                     T1.617a-1994, ITU-T Recommendation Q.933 (03/93)."
        DEFVAL      { ansi617d1994 }
        ::= { adGenFrGroupEntry 5 }

    adGenFrGroupLmiStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                              up(1),
                              down(2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The value of this object identifies status of local in-channel signaling
                     protocol.  If the signaling protocol is 'none', then this object will
                     report 'up'."
        ::= { adGenFrGroupEntry 6 }

    adGenFrGroupLmiEnquiryIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages received.  If the logical
                     port is not performing network-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupEntry 7 }

    adGenFrGroupLmiEnquiryOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages transmitted.  If the logical
                     port is not performing user-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupEntry 8 }

    adGenFrGroupLmiStatusIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages received.  If the logical port
                     is not performing user-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupEntry 9 }

    adGenFrGroupLmiStatusOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages transmitted.  If the logical port
                     is not performing network-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupEntry 10 }

    adGenFrGroupLmiInvalidIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of invalid LMI messages received by this logical port."
        ::= { adGenFrGroupEntry 11 }

    adGenFrGroupLmiStatusEnqTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status Enquiry message in T392 seconds.  If the logical port is
                     not performing network-side or bidirectional procedures then this
                     object is not applicable."
        ::= { adGenFrGroupEntry 12 }

    adGenFrGroupLmiStatusTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status message in a polling interval (within T391 seconds).  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupEntry 13 }

    adGenFrGroupClearCounters OBJECT-TYPE
        SYNTAX      INTEGER { reset(1) }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Writing a value of 1 will reset the interface and signaling
                     statistics for this logical port."
         ::= { adGenFrGroupEntry 14 }

    adGenFrGroupClearPmHistory OBJECT-TYPE
        SYNTAX      INTEGER { reset(1) }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Writing a value of 1 will reset the interface performance
                     monitoring statistics/intervals for this logical port."
         ::= { adGenFrGroupEntry 15 }
                                               
    adGenFrGroupLinkLastCreateError OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason for the last error that occurred while attempting to
                     create an entry in the Frame Relay Link Table (adGenFrLinkTable)
                     for this specific frame relay group."
         ::= { adGenFrGroupEntry 16 }
                                               
    adGenFrGroupPvcLastCreateError OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason for the last error that occurred while attempting to
                     create an entry in the Frame Relay PVC Table (adGenFrPVCTable)
                     for this specific frame relay group."
         ::= { adGenFrGroupEntry 17 }

    -- ******************************************************************
    -- The Frame Relay Group Current Table
    -- ******************************************************************
    
    adGenFrGroupCurrentTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrGroupCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR Group current table contains performance
                     monitoring data for the current 15-minute interval."
         ::= { adGenFrGroup 3 }

    adGenFrGroupCurrentEntry OBJECT-TYPE
        SYNTAX      AdGenFrGroupCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR Group current table"
        INDEX       { ifIndex }
         ::= { adGenFrGroupCurrentTable 1 }

    AdGenFrGroupCurrentEntry ::= SEQUENCE {
        adGenFrGroupCurrentInOctets             Counter32,
        adGenFrGroupCurrentInPkts               Counter32,
        adGenFrGroupCurrentInDiscards           Counter32,
        adGenFrGroupCurrentInErrors             Counter32,
        adGenFrGroupCurrentOutOctets            Counter32,
        adGenFrGroupCurrentOutPkts              Counter32,
        adGenFrGroupCurrentOutDiscards          Counter32,
        adGenFrGroupCurrentOutErrors            Counter32,
        adGenFrGroupCurrentLmiEnquiryIn         Counter32,
        adGenFrGroupCurrentLmiEnquiryOut        Counter32,
        adGenFrGroupCurrentLmiStatusIn          Counter32,
        adGenFrGroupCurrentLmiStatusOut         Counter32,
        adGenFrGroupCurrentLmiInvalidIn         Counter32,
        adGenFrGroupCurrentLmiStatusEnqTimeouts Counter32,
        adGenFrGroupCurrentLmiStatusTimeouts    Counter32,
        adGenFrGroupCurrentNetworkInactive      Counter32
    }

    adGenFrGroupCurrentInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR Group."

        ::= { adGenFrGroupCurrentEntry 1 }

    adGenFrGroupCurrentInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR Group."

        ::= { adGenFrGroupCurrentEntry 2 }

    adGenFrGroupCurrentInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR Group."

        ::= { adGenFrGroupCurrentEntry 3 }

    adGenFrGroupCurrentInErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets received on the FR Group."

        ::= { adGenFrGroupCurrentEntry 4 }

    adGenFrGroupCurrentOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR Group."

        ::= { adGenFrGroupCurrentEntry 5 }

    adGenFrGroupCurrentOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR Group."

        ::= { adGenFrGroupCurrentEntry 6 }

    adGenFrGroupCurrentOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR Group."

        ::= { adGenFrGroupCurrentEntry 7 }

    adGenFrGroupCurrentOutErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets transmitted on the FR Group."

        ::= { adGenFrGroupCurrentEntry 8 }

    adGenFrGroupCurrentLmiEnquiryIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages received.  If the logical
                     port is not performing network-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 9 }

    adGenFrGroupCurrentLmiEnquiryOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages transmitted.  If the logical
                     port is not performing user-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 10 }

    adGenFrGroupCurrentLmiStatusIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages received.  If the logical port
                     is not performing user-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 11 }

    adGenFrGroupCurrentLmiStatusOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages transmitted.  If the logical port
                     is not performing network-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 12 }

    adGenFrGroupCurrentLmiInvalidIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of invalid LMI messages received by this logical port."
        ::= { adGenFrGroupCurrentEntry 13 }

    adGenFrGroupCurrentLmiStatusEnqTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status Enquiry message in T392 seconds.  If the logical port is
                     not performing network-side or bidirectional procedures then this
                     object is not applicable."
        ::= { adGenFrGroupCurrentEntry 14 }

    adGenFrGroupCurrentLmiStatusTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status message in a polling interval (within T391 seconds).  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 15 }
    
    adGenFrGroupCurrentNetworkInactive OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "TODO.  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupCurrentEntry 16 }
    
    -- ******************************************************************
    -- The FR Group Interval Table
    -- ******************************************************************
    
    adGenFrGroupIntervalTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrGroupIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR Group Interval Table contains various statistics
                     collected by each Frame Relay Group over the previous
                     24 hours of operation. The past 24 hours are broken
                     into 96 completed 15-minute intervals.  Each row in
                     this table represents one such interval (identified by
                     adGenFrGroupIntervalNumber) and for one specific
                     interface (identifed by ifIndex)."
         ::= { adGenFrGroup 4 }

    adGenFrGroupIntervalEntry OBJECT-TYPE
        SYNTAX      AdGenFrGroupIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR Group Interval table"
        INDEX       { ifIndex, adGenFrGroupIntervalNumber }
         ::= { adGenFrGroupIntervalTable 1 }

    AdGenFrGroupIntervalEntry ::= SEQUENCE {
        adGenFrGroupIntervalNumber               INTEGER,
        adGenFrGroupIntervalTimeStamp            DisplayString,
        adGenFrGroupIntervalInOctets             Counter32,
        adGenFrGroupIntervalInPkts               Counter32,
        adGenFrGroupIntervalInDiscards           Counter32,
        adGenFrGroupIntervalInErrors             Counter32,
        adGenFrGroupIntervalOutOctets            Counter32,
        adGenFrGroupIntervalOutPkts              Counter32,
        adGenFrGroupIntervalOutDiscards          Counter32,
        adGenFrGroupIntervalOutErrors            Counter32,
        adGenFrGroupIntervalLmiEnquiryIn         Counter32,
        adGenFrGroupIntervalLmiEnquiryOut        Counter32,
        adGenFrGroupIntervalLmiStatusIn          Counter32,
        adGenFrGroupIntervalLmiStatusOut         Counter32,
        adGenFrGroupIntervalLmiInvalidIn         Counter32,
        adGenFrGroupIntervalLmiStatusEnqTimeouts Counter32,
        adGenFrGroupIntervalLmiStatusTimeouts    Counter32,
        adGenFrGroupIntervalNetworkInactive      Counter32
    }
    
    adGenFrGroupIntervalNumber OBJECT-TYPE
        SYNTAX      INTEGER (1..96)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "A number between 1 and 96, where 1 is the most
                     recently completed 15-minute interval and 96 is the least
                     recently completed 15-minute interval (assuming that all
                     96 intervals are valid)."
        ::= { adGenFrGroupIntervalEntry 1 }
    
    adGenFrGroupIntervalTimeStamp OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Timestamp of the 15-minute interval"

        ::= { adGenFrGroupIntervalEntry 2 }

    adGenFrGroupIntervalInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR Group."

        ::= { adGenFrGroupIntervalEntry 3 }

    adGenFrGroupIntervalInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR Group."

        ::= { adGenFrGroupIntervalEntry 4 }

    adGenFrGroupIntervalInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR Group."

        ::= { adGenFrGroupIntervalEntry 5 }

    adGenFrGroupIntervalInErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets received on the FR Group."

        ::= { adGenFrGroupIntervalEntry 6 }

    adGenFrGroupIntervalOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR Group."

        ::= { adGenFrGroupIntervalEntry 7 }

    adGenFrGroupIntervalOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR Group."

        ::= { adGenFrGroupIntervalEntry 8 }

    adGenFrGroupIntervalOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR Group."

        ::= { adGenFrGroupIntervalEntry 9 }

    adGenFrGroupIntervalOutErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets transmitted on the FR Group."

        ::= { adGenFrGroupIntervalEntry 10 }

    adGenFrGroupIntervalLmiEnquiryIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages received.  If the logical
                     port is not performing network-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 11 }

    adGenFrGroupIntervalLmiEnquiryOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages transmitted.  If the logical
                     port is not performing user-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 12 }

    adGenFrGroupIntervalLmiStatusIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages received.  If the logical port
                     is not performing user-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 13 }

    adGenFrGroupIntervalLmiStatusOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages transmitted.  If the logical port
                     is not performing network-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 14 }

    adGenFrGroupIntervalLmiInvalidIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of invalid LMI messages received by this logical port."
        ::= { adGenFrGroupIntervalEntry 15 }

    adGenFrGroupIntervalLmiStatusEnqTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status Enquiry message in T392 seconds.  If the logical port is
                     not performing network-side or bidirectional procedures then this
                     object is not applicable."
        ::= { adGenFrGroupIntervalEntry 16 }

    adGenFrGroupIntervalLmiStatusTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status message in a polling interval (within T391 seconds).  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 17 }
    
    adGenFrGroupIntervalNetworkInactive OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "TODO.  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupIntervalEntry 18 }
    
    -- ******************************************************************
    -- The Frame Relay Group Current Day Table
    -- ******************************************************************
    
    adGenFrGroupDayCurrentTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrGroupDayCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR Group current day table contains performance
                     monitoring data for the current 24-hour interval."
         ::= { adGenFrGroup 5 }

    adGenFrGroupDayCurrentEntry OBJECT-TYPE
        SYNTAX      AdGenFrGroupDayCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR Group current day table"
        INDEX       { ifIndex }
         ::= { adGenFrGroupDayCurrentTable 1 }

    AdGenFrGroupDayCurrentEntry ::= SEQUENCE {
        adGenFrGroupDayCurrentInOctets             Counter32,
        adGenFrGroupDayCurrentInPkts               Counter32,
        adGenFrGroupDayCurrentInDiscards           Counter32,
        adGenFrGroupDayCurrentInErrors             Counter32,
        adGenFrGroupDayCurrentOutOctets            Counter32,
        adGenFrGroupDayCurrentOutPkts              Counter32,
        adGenFrGroupDayCurrentOutDiscards          Counter32,
        adGenFrGroupDayCurrentOutErrors            Counter32,
        adGenFrGroupDayCurrentLmiEnquiryIn         Counter32,
        adGenFrGroupDayCurrentLmiEnquiryOut        Counter32,
        adGenFrGroupDayCurrentLmiStatusIn          Counter32,
        adGenFrGroupDayCurrentLmiStatusOut         Counter32,
        adGenFrGroupDayCurrentLmiInvalidIn         Counter32,
        adGenFrGroupDayCurrentLmiStatusEnqTimeouts Counter32,
        adGenFrGroupDayCurrentLmiStatusTimeouts    Counter32,
        adGenFrGroupDayCurrentNetworkInactive      Counter32
    }

    adGenFrGroupDayCurrentInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 1 }

    adGenFrGroupDayCurrentInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 2 }

    adGenFrGroupDayCurrentInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 3 }

    adGenFrGroupDayCurrentInErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets received on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 4 }

    adGenFrGroupDayCurrentOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 5 }

    adGenFrGroupDayCurrentOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 6 }

    adGenFrGroupDayCurrentOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 7 }

    adGenFrGroupDayCurrentOutErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets transmitted on the FR Group."

        ::= { adGenFrGroupDayCurrentEntry 8 }

    adGenFrGroupDayCurrentLmiEnquiryIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages received.  If the logical
                     port is not performing network-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 9 }

    adGenFrGroupDayCurrentLmiEnquiryOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages transmitted.  If the logical
                     port is not performing user-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 10 }

    adGenFrGroupDayCurrentLmiStatusIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages received.  If the logical port
                     is not performing user-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 11 }

    adGenFrGroupDayCurrentLmiStatusOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages transmitted.  If the logical port
                     is not performing network-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 12 }

    adGenFrGroupDayCurrentLmiInvalidIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of invalid LMI messages received by this logical port."
        ::= { adGenFrGroupDayCurrentEntry 13 }

    adGenFrGroupDayCurrentLmiStatusEnqTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status Enquiry message in T392 seconds.  If the logical port is
                     not performing network-side or bidirectional procedures then this
                     object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 14 }

    adGenFrGroupDayCurrentLmiStatusTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status message in a polling interval (within T391 seconds).  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 15 }
    
    adGenFrGroupDayCurrentNetworkInactive OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "TODO.  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupDayCurrentEntry 16 }
        
    -- ******************************************************************
    -- The FR Group Day Interval Table
    -- ******************************************************************
    
    adGenFrGroupDayIntervalTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrGroupDayIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR Group Day Interval Table contains various statistics
                     collected by each Frame Relay Group over the previous 7 days of
                     operation.  The past 7 days are broken into completed 24-hour
                     intervals.  Each row in this table represents one such interval
                     (identified by adGenFrGroupDayIntervalNumber) and for one specific
                     interface (identifed by ifIndex)."
         ::= { adGenFrGroup 6 }

    adGenFrGroupDayIntervalEntry OBJECT-TYPE
        SYNTAX      AdGenFrGroupDayIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR Group Interval table"
        INDEX       { ifIndex, adGenFrGroupDayIntervalNumber }
         ::= { adGenFrGroupDayIntervalTable 1 }

    AdGenFrGroupDayIntervalEntry ::= SEQUENCE {
        adGenFrGroupDayIntervalNumber               INTEGER,
        adGenFrGroupDayIntervalTimeStamp            DisplayString,
        adGenFrGroupDayIntervalInOctets             Counter32,
        adGenFrGroupDayIntervalInPkts               Counter32,
        adGenFrGroupDayIntervalInDiscards           Counter32,
        adGenFrGroupDayIntervalInErrors             Counter32,
        adGenFrGroupDayIntervalOutOctets            Counter32,
        adGenFrGroupDayIntervalOutPkts              Counter32,
        adGenFrGroupDayIntervalOutDiscards          Counter32,
        adGenFrGroupDayIntervalOutErrors            Counter32,
        adGenFrGroupDayIntervalLmiEnquiryIn         Counter32,
        adGenFrGroupDayIntervalLmiEnquiryOut        Counter32,
        adGenFrGroupDayIntervalLmiStatusIn          Counter32,
        adGenFrGroupDayIntervalLmiStatusOut         Counter32,
        adGenFrGroupDayIntervalLmiInvalidIn         Counter32,
        adGenFrGroupDayIntervalLmiStatusEnqTimeouts Counter32,
        adGenFrGroupDayIntervalLmiStatusTimeouts    Counter32,
        adGenFrGroupDayIntervalNetworkInactive      Counter32
    }
    
    adGenFrGroupDayIntervalNumber OBJECT-TYPE
        SYNTAX      INTEGER (1..7)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "A number between 1 and 7, where 1 is the most
                     recently completed 24-hour interval and 96 is the least
                     recently completed 24-hour interval (assuming that all
                     7 intervals are valid)."
        ::= { adGenFrGroupDayIntervalEntry 1 }
    
    adGenFrGroupDayIntervalTimeStamp OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Timestamp of the 15-minute interval"

        ::= { adGenFrGroupDayIntervalEntry 2 }

    adGenFrGroupDayIntervalInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 3 }

    adGenFrGroupDayIntervalInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 4 }

    adGenFrGroupDayIntervalInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 5 }

    adGenFrGroupDayIntervalInErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets received on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 6 }

    adGenFrGroupDayIntervalOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 7 }

    adGenFrGroupDayIntervalOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 8 }

    adGenFrGroupDayIntervalOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 9 }

    adGenFrGroupDayIntervalOutErrors OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of errored packets transmitted on the FR Group."

        ::= { adGenFrGroupDayIntervalEntry 10 }

    adGenFrGroupDayIntervalLmiEnquiryIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages received.  If the logical
                     port is not performing network-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 11 }

    adGenFrGroupDayIntervalLmiEnquiryOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status Enquiry messages transmitted.  If the logical
                     port is not performing user-side or bidirectional procedures
                     then this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 12 }

    adGenFrGroupDayIntervalLmiStatusIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages received.  If the logical port
                     is not performing user-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 13 }

    adGenFrGroupDayIntervalLmiStatusOut OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of Status messages transmitted.  If the logical port
                     is not performing network-side or bidirectional procedures then
                     this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 14 }

    adGenFrGroupDayIntervalLmiInvalidIn OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of invalid LMI messages received by this logical port."
        ::= { adGenFrGroupDayIntervalEntry 15 }

    adGenFrGroupDayIntervalLmiStatusEnqTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status Enquiry message in T392 seconds.  If the logical port is
                     not performing network-side or bidirectional procedures then this
                     object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 16 }

    adGenFrGroupDayIntervalLmiStatusTimeouts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of times this logical port has failed to receive a
                     Status message in a polling interval (within T391 seconds).  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 17 }
    
    adGenFrGroupDayIntervalNetworkInactive OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "TODO.  If
                     the logical port is not performing user-side or bidirectional
                     procedures then this object is not applicable."
        ::= { adGenFrGroupDayIntervalEntry 18 }
    
    -- ******************************************************************
    -- The Frame Relay Link Provisioning Table
    -- ******************************************************************

    adGenFrLinkTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrLinkEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This table provides provisioning and status information
                     on all frame relay links."
         ::= { adGenFrLink 2 }

    adGenFrLinkEntry OBJECT-TYPE
        SYNTAX      AdGenFrLinkEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The Frame Relay Link provisioning and status table entry."
        INDEX       { adGenFrLinkGroupIfIndex, adGenFrLinkIfIndex, adGenFrLinkBundleId }
         ::= { adGenFrLinkTable 1 }

    AdGenFrLinkEntry ::= SEQUENCE {
          adGenFrLinkGroupIfIndex       InterfaceIndex,
          adGenFrLinkIfIndex            InterfaceIndex,
          adGenFrLinkBundleId           INTEGER,
          adGenFrLinkRowStatus          RowStatus,
          adGenFrLinkTimeslots          DisplayString,
          adGenFrLinkStatusString       DisplayString
       }

     adGenFrLinkGroupIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This object represents the frame relay group to which
                     this frame relay link is to be connected."
     ::= { adGenFrLinkEntry 1 }

     adGenFrLinkIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This object represents the physical T1/E1 link to which
                     this frame relay link is to constructed from."
     ::= { adGenFrLinkEntry 2 }

     adGenFrLinkBundleId OBJECT-TYPE
        SYNTAX      INTEGER (1..32)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This object represents the ds0 bundle ID number for this
                     frame relay link.  Some hardware implementations will
                     only support a single ds0 bundle per T1/E1 link.  For
                     implementations with this limitation, the bundle ID may
                     only be 1."
     ::= { adGenFrLinkEntry 3 }

    adGenFrLinkRowStatus OBJECT-TYPE
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The adGenFrLinkRowStatus object allows create, change, and
                     delete operations on the Frame Relay link."
         ::= { adGenFrLinkEntry 4 }

    adGenFrLinkTimeslots OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The adGenFrLinkTimeslots is a string representation of
        	         the timeslot or timeslot range that describes the active
        	         ds0's for this link.

        	         For example:

        	         To indicate that timeslots 3 through 8 are active, the
        	         string would be '3-8'.

        	         To indicate a single ds0, such as timeslot 18, the string
        	         would be '18'."
         DEFVAL      { "1-24" }
         ::= { adGenFrLinkEntry 5 }

    adGenFrLinkStatusString OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason, if any, why the frame relay link is
                     not in an operational state due to provisioning or
                     hardware limitations."
         ::= { adGenFrLinkEntry 7 }

    -- ******************************************************************
    -- The Frame Relay PVC Provisioning Table
    -- ******************************************************************

    -- adGenFrPVC      OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 3 }

    adGenFrPVCTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrPVCEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This table provides provisioning and status information
                     on all frame relay virtual circuits (PVCs)."
         ::= { adGenFrPVC 4 }

    adGenFrPVCEntry OBJECT-TYPE
        SYNTAX      AdGenFrPVCEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The Frame Relay PVC supplemental provisioning and status
                    table entry.  To create a Frame Relay PVC, the following
                    procedures are used:

                     (1) The management application creates Frame Relay PVC by
                         creating entry in the frPVCEndptTable by setting the
                         frPVCEndPtRowStatus to createAndWait(5).

                         This may fail for the following reasons which are reported
                         through the associated frame-relay group's 
                         adGenFrGroupPvcLastCreateError object.

                         - The selected adGenFrPVCIfIndex specifies an invalid interface
                         - The selected frPVCEndptDLCIIndex specifies an invalid or
                           reserved DLCI value
                         - The selected frPVCEndptDLCIIndex is already in use by
                           another Frame Relay PVC on this group
                         - The maximum number of PVCs for this access module has
                           been created and resources are not available for creation
                           of another PVC.

                         Otherwise, upon successful creation of the row, the PVC
                         is reserved and a corresponding row (identical ifIndex
                         (adGenFrPVCIfIndex) and  DLCI (adGenFrPVCDLCIIndex) in
                         this table is created.

                     (2) The manager sets other provisioning rows in the
                         adGenFrPVCTable and the frPVCEndptTable that are
                         appropriate for the service that is to be provided.

                     (3) Provisioning failures or conflicts with other provisioning
                         for a PVC can be detected by examining the adGenFrPVCStatus
                         string.
                     "
        INDEX       { ifIndex, adGenFrPVCDLCIIndex }
         ::= { adGenFrPVCTable 1 }

    AdGenFrPVCEntry ::= SEQUENCE {
        adGenFrPVCIfIndex                         InterfaceIndex,
        adGenFrPVCDLCIIndex                       Integer32,
        adGenFrPVCStatusString                    DisplayString,
        adGenFrPVCAdminStatus                     INTEGER,
        adGenFrPVCState                           INTEGER,

        adGenFrPVCEncapsulation                   INTEGER,
        adGenFrPVCPrimaryPeerIpAddressType        InetAddressType,
        adGenFrPVCPrimaryPeerIpAddress            InetAddress,
        adGenFrPVCSecondaryPeerAddressType        InetAddressType,
        adGenFrPVCSecondaryPeerIpAddress          InetAddress,
        adGenFrPVCPrimaryGatewayAddressType       InetAddressType,
        adGenFrPVCPrimaryGatewayAddress           InetAddress,
        adGenFrPVCInverseArpEnable                TruthValue,
        adGenFrPVCLearnedPrimaryPeerIpAddressType InetAddressType,
        adGenFrPVCLearnedPrimaryPeerIpAddress     InetAddress,
        adGenFrPVCLearnedSecondaryPeerAddressType InetAddressType,
        adGenFrPVCLearnedSecondaryPeerIpAddress   InetAddress,
        adGenFrPVCClearCounters                   INTEGER,
        adGenFrPVCClearPmHistory                  INTEGER,
        adGenFrPVCOperStatus                      INTEGER,
        adGenFrPVCLastChange                      TimeTicks,
        adGenFrPVCDescription                     DisplayString,
        adGenFrPVCMtu                             Integer32
    }
                      
    adGenFrPVCIfIndex OBJECT-TYPE
        SYNTAX      InterfaceIndex
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The value of this object is equal to the ifIndex
                    value for this PVC end-point."
         ::= { adGenFrPVCEntry 1 }

    adGenFrPVCDLCIIndex OBJECT-TYPE
        SYNTAX      Integer32 (16..991)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The value of this object is equal to the DLCI
                    value for this PVC end-point.

                    The values are restricted to the legal range for
                    the size of address field supported by the
                    application which is currently 10-bits."
        REFERENCE   "ITU Q.922"

         ::= { adGenFrPVCEntry 2 }

     adGenFrPVCStatusString OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason, if any, why the why the PVC is not in an
                     operational state due to provisioning or hardware limitations."
         ::= { adGenFrPVCEntry 3 }

    adGenFrPVCAdminStatus OBJECT-TYPE
        SYNTAX      INTEGER {
                              up(1),
                              down(2),
                              testing(3)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The desired state of the frame relay PVC.  This object
                     must be set to up(1) or testing(3) to enable user data
                     transmission on the PVC."
        DEFVAL      { down }
        ::= { adGenFrPVCEntry 4 }

    adGenFrPVCState OBJECT-TYPE
        SYNTAX      INTEGER {
                              new(1),     -- PVC is new
                              none(2),    -- in-channel signaling is disabled or starting
                              active(3),  -- PVC is operational
                              inactive(4),-- PVC is not operational
                              deleted(5)  -- PVC is marked for deletion
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "This object provides the operation state information of
                     the PVC."
        ::= { adGenFrPVCEntry 5 }

    adGenFrPVCEncapsulation OBJECT-TYPE
        SYNTAX      INTEGER {
                              ipv4(1)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The network protocol encapsulated on this frame relay PVC."
        DEFVAL      { ipv4 }
        ::= { adGenFrPVCEntry 6 }

    adGenFrPVCPrimaryPeerIpAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
                     adGenFrPVCPrimaryPeerIpAddress column.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        DEFVAL      { ipv4 }
        ::= { adGenFrPVCEntry 7 }

    adGenFrPVCPrimaryPeerIpAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Provisioned Primary Peer IP address.  If this object
                     is set to a valid non-zero IP address and Inverse ARP
                     is enabled, the address much match that learned from
                     the Inverse ARP protocol.  If they do not match, nor
                     does the adGenFrPVCSecondaryIpAddress match, then
                     user data transmission over the PVC will be disabled
                     and the adGenFrPVCState object will report inactive(3)."
        ::= { adGenFrPVCEntry 8 }

    adGenFrPVCSecondaryPeerAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
                     adGenFrPVCSecondaryPeerIpAddress column.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        DEFVAL      { ipv4 }
        ::= { adGenFrPVCEntry 9 }

    adGenFrPVCSecondaryPeerIpAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Provisioned Secondary Peer IP address.  If this object
                     is set to a valid non-zero IP address and Inverse ARP
                     is enabled, the address much match that learned from
                     the Inverse ARP protocol.  If they do not match, nor
                     does the adGenFrPVCPrimaryIpAddress match, then
                     user data transmission over the PVC will be disabled
                     and the adGenFrPVCState object will report inactive(3)."
        ::= { adGenFrPVCEntry 10 }

    adGenFrPVCPrimaryGatewayAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
                     adGenFrPVCPrimaryGatewayAddress column.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        DEFVAL      { ipv4 }
        ::= { adGenFrPVCEntry 11 }

    adGenFrPVCPrimaryGatewayAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "The primary gateway IP address for the peer.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        ::= { adGenFrPVCEntry 12 }

    adGenFrPVCInverseArpEnable OBJECT-TYPE
        SYNTAX      TruthValue
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Setting this value to true enables transmission of Inverse ARP
                     requests by this frame relay PVC.   If the encapsulation protocol
                     is not ipv4, this oid has no effect.  Note that if InARP request
                     transmissions are disabled and an InARP request is received from
                     the peer, a InARP response will be transmitted if appropriate."
        DEFVAL      { true }
        ::= { adGenFrPVCEntry 19 }

    adGenFrPVCLearnedPrimaryPeerIpAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Learned IP address type (ipv4 or ipv6) represented by in the
                     adGenFrPVCLearnedPrimaryPeerIpAddress column.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        ::= { adGenFrPVCEntry 20 }

    adGenFrPVCLearnedPrimaryPeerIpAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Learned Primary Peer IP address.  This value
                     is learned through the Inverse ARP protocol mechanism."
        ::= { adGenFrPVCEntry 21 }

    adGenFrPVCLearnedSecondaryPeerAddressType OBJECT-TYPE
        SYNTAX      InetAddressType
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Learned IP address type (ipv4 or ipv6) represented by in the
                     adGenFrPVCLearnedSecondaryPeerIpAddress column.  This oid is only
                     significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
        ::= { adGenFrPVCEntry 22 }

    adGenFrPVCLearnedSecondaryPeerIpAddress OBJECT-TYPE
        SYNTAX      InetAddress
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Learned Secondary Peer IP address.  This value
                     is learned through the Inverse ARP protocol mechanism."
        ::= { adGenFrPVCEntry 23 }
        
    adGenFrPVCClearCounters OBJECT-TYPE
        SYNTAX      INTEGER { reset(1) }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Writing a value of 1 will reset the PVC statistics for
                     this logical port."
         ::= { adGenFrPVCEntry 24 }

    adGenFrPVCClearPmHistory OBJECT-TYPE
        SYNTAX      INTEGER { reset(1) }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION "Writing a value of 1 will reset the interface performance
                     monitoring statistics/intervals for this logical port."
         ::= { adGenFrPVCEntry 25 }

    adGenFrPVCOperStatus OBJECT-TYPE
       SYNTAX  INTEGER {
                   up(1),        -- ready to pass packets
                   down(2),
                   testing(3),   -- not expected
                   unknown(4),   -- status can not be determined
                                 -- for some reason.
                   dormant(5),
                   notPresent(6),    -- some component is missing
                   lowerLayerDown(7) -- down due to state of
                                     -- lower-layer interface(s)
               }

       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The current operational state of the PVC."
       ::= { adGenFrPVCEntry 26 }

   adGenFrPVCLastChange OBJECT-TYPE
       SYNTAX      TimeTicks
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
               "The value of sysUpTime at the time the PVC
               entered its current operational state.  If the current
               state was entered prior to the last re-initialization
               of the local network management subsystem, then this
               object contains a zero value."
       ::= { adGenFrPVCEntry 27 }

   adGenFrPVCDescription OBJECT-TYPE
       SYNTAX      DisplayString
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
               "A descriptive name for the PVC"
       ::= { adGenFrPVCEntry 28 }

   adGenFrPVCMtu OBJECT-TYPE
       SYNTAX      Integer32 (262..1600)
       UNITS       "Octets"
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
               "The size of the largest packet which can be
               sent/received on the interface, specified in octets.
               For a PVC, this is the size of the frame relay payload
               and does not count the HDLC start/end flags, Frame Relay
               address field, or the CRC-16 trailer."
       DEFVAL      { 1500 }
       ::= { adGenFrPVCEntry 29 }

    -- ******************************************************************
    -- The Frame Relay PVC Current Table
    -- ******************************************************************

    adGenFrPVCCurrentTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrPVCCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR PVC current table contains performance
                     monitoring data for the current 15-minute interval."
         ::= { adGenFrPVC 5 }

    adGenFrPVCCurrentEntry OBJECT-TYPE
        SYNTAX      AdGenFrPVCCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR PVC Current table"
        INDEX       { ifIndex, adGenFrPVCDLCIIndex }
         ::= { adGenFrPVCCurrentTable 1 }

    AdGenFrPVCCurrentEntry ::= SEQUENCE {
        adGenFrPVCCurrentInOctets                        Counter32,
        adGenFrPVCCurrentInPkts                          Counter32,
        adGenFrPVCCurrentInDiscards                      Counter32,
        adGenFrPVCCurrentOutOctets                       Counter32,
        adGenFrPVCCurrentOutPkts                         Counter32,
        adGenFrPVCCurrentOutDiscards                     Counter32,
        adGenFrPVCCurrentPktsFECN1In                     Counter32,
        adGenFrPVCCurrentPktsFECN1Out                    Counter32,
        adGenFrPVCCurrentPktsBECN1In                     Counter32,
        adGenFrPVCCurrentPktsBECN1Out                    Counter32,
        adGenFrPVCCurrentPktsDE1In                       Counter32,
        adGenFrPVCCurrentPktsDE1Out                      Counter32,
        adGenFrPVCCurrentOctetsDE1In                     Counter32,
        adGenFrPVCCurrentOctetsDE1Out                    Counter32
    }
    
    adGenFrPVCCurrentInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 1 }

    adGenFrPVCCurrentInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 2 }

    adGenFrPVCCurrentInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 3 }

    adGenFrPVCCurrentOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 5 }

    adGenFrPVCCurrentOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 6 }

    adGenFrPVCCurrentOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR PVC."

        ::= { adGenFrPVCCurrentEntry 7 }

    adGenFrPVCCurrentPktsFECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCCurrentEntry 9 }

    adGenFrPVCCurrentPktsFECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCCurrentEntry 10 }

    adGenFrPVCCurrentPktsBECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCCurrentEntry 11 }

    adGenFrPVCCurrentPktsBECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCCurrentEntry 12 }

    adGenFrPVCCurrentPktsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCCurrentEntry 13 }

    adGenFrPVCCurrentPktsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCCurrentEntry 14 }

    adGenFrPVCCurrentOctetsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCCurrentEntry 15 }
    
    adGenFrPVCCurrentOctetsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCCurrentEntry 16 }

    -- ******************************************************************
    -- The Frame Relay PVC Interval Table
    -- ******************************************************************

    adGenFrPVCIntervalTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrPVCIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR PVC Interval Table contains various statistics
                     collected by each Frame Relay PVC over the previous
                     24 hours of operation. The past 24 hours are broken
                     into 96 completed 15-minute intervals.  Each row in
                     this table represents one such interval (identified by
                     adGenFrPVCIntervalNumber) and for one specific
                     interface (identifed by ifIndex and
                     adGenFrPVCDLCIIndex)."
         ::= { adGenFrPVC 6 }

    adGenFrPVCIntervalEntry OBJECT-TYPE
        SYNTAX      AdGenFrPVCIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR PVC Interval table"
        INDEX       { ifIndex, adGenFrPVCDLCIIndex, adGenFrPVCIntervalNumber }
         ::= { adGenFrPVCIntervalTable 1 }

    AdGenFrPVCIntervalEntry ::= SEQUENCE {
        adGenFrPVCIntervalNumber                          INTEGER,
        adGenFrPVCIntervalTimeStamp                       DisplayString,
        adGenFrPVCIntervalInOctets                        Counter32,
        adGenFrPVCIntervalInPkts                          Counter32,
        adGenFrPVCIntervalInDiscards                      Counter32,
        adGenFrPVCIntervalOutOctets                       Counter32,
        adGenFrPVCIntervalOutPkts                         Counter32,
        adGenFrPVCIntervalOutDiscards                     Counter32,
        adGenFrPVCIntervalPktsFECN1In                     Counter32,
        adGenFrPVCIntervalPktsFECN1Out                    Counter32,
        adGenFrPVCIntervalPktsBECN1In                     Counter32,
        adGenFrPVCIntervalPktsBECN1Out                    Counter32,
        adGenFrPVCIntervalPktsDE1In                       Counter32,
        adGenFrPVCIntervalPktsDE1Out                      Counter32,
        adGenFrPVCIntervalOctetsDE1In                     Counter32,
        adGenFrPVCIntervalOctetsDE1Out                    Counter32
    }

    adGenFrPVCIntervalNumber OBJECT-TYPE
        SYNTAX      INTEGER (1..96)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "A number between 1 and 96, where 1 is the most
                     recently completed 15-minute interval and 96 is the least
                     recently completed 15-minute interval (assuming that all
                     96 intervals are valid)."
        ::= { adGenFrPVCIntervalEntry 1 }
    
    adGenFrPVCIntervalTimeStamp OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Timestamp of the 15-minute interval"

        ::= { adGenFrPVCIntervalEntry 2 }

    adGenFrPVCIntervalInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 3 }

    adGenFrPVCIntervalInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 4 }

    adGenFrPVCIntervalInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 5 }

    adGenFrPVCIntervalOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 7 }

    adGenFrPVCIntervalOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 8 }

    adGenFrPVCIntervalOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR PVC."

        ::= { adGenFrPVCIntervalEntry 9 }

    adGenFrPVCIntervalPktsFECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCIntervalEntry 11 }

    adGenFrPVCIntervalPktsFECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCIntervalEntry 12 }

    adGenFrPVCIntervalPktsBECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCIntervalEntry 13 }

    adGenFrPVCIntervalPktsBECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCIntervalEntry 14 }

    adGenFrPVCIntervalPktsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCIntervalEntry 15 }

    adGenFrPVCIntervalPktsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCIntervalEntry 16 }

    adGenFrPVCIntervalOctetsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCIntervalEntry 17 }
    
    adGenFrPVCIntervalOctetsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCIntervalEntry 18 }

    -- ******************************************************************
    -- The Frame Relay PVC Day Current Table
    -- ******************************************************************

    adGenFrPVCDayCurrentTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrPVCDayCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR PVC current day table contains performance
                     monitoring data for the current 24-hour interval."
         ::= { adGenFrPVC 7 }

    adGenFrPVCDayCurrentEntry OBJECT-TYPE
        SYNTAX      AdGenFrPVCDayCurrentEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR PVC current day table"
        INDEX       { ifIndex, adGenFrPVCDLCIIndex }
         ::= { adGenFrPVCDayCurrentTable 1 }

    AdGenFrPVCDayCurrentEntry ::= SEQUENCE {
        adGenFrPVCDayCurrentInOctets                        Counter32,
        adGenFrPVCDayCurrentInPkts                          Counter32,
        adGenFrPVCDayCurrentInDiscards                      Counter32,
        adGenFrPVCDayCurrentOutOctets                       Counter32,
        adGenFrPVCDayCurrentOutPkts                         Counter32,
        adGenFrPVCDayCurrentOutDiscards                     Counter32,
        adGenFrPVCDayCurrentPktsFECN1In                     Counter32,
        adGenFrPVCDayCurrentPktsFECN1Out                    Counter32,
        adGenFrPVCDayCurrentPktsBECN1In                     Counter32,
        adGenFrPVCDayCurrentPktsBECN1Out                    Counter32,
        adGenFrPVCDayCurrentPktsDE1In                       Counter32,
        adGenFrPVCDayCurrentPktsDE1Out                      Counter32,
        adGenFrPVCDayCurrentOctetsDE1In                     Counter32,
        adGenFrPVCDayCurrentOctetsDE1Out                    Counter32
    }
    
    adGenFrPVCDayCurrentInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 1 }

    adGenFrPVCDayCurrentInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 2 }

    adGenFrPVCDayCurrentInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 3 }

    adGenFrPVCDayCurrentOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 5 }

    adGenFrPVCDayCurrentOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 6 }

    adGenFrPVCDayCurrentOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR PVC."

        ::= { adGenFrPVCDayCurrentEntry 7 }

    adGenFrPVCDayCurrentPktsFECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 9 }

    adGenFrPVCDayCurrentPktsFECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 10 }

    adGenFrPVCDayCurrentPktsBECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 11 }

    adGenFrPVCDayCurrentPktsBECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 12 }

    adGenFrPVCDayCurrentPktsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 13 }

    adGenFrPVCDayCurrentPktsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 14 }

    adGenFrPVCDayCurrentOctetsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 15 }
    
    adGenFrPVCDayCurrentOctetsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayCurrentEntry 16 }
    
    -- ******************************************************************
    -- The Frame Relay PVC Day Interval Table
    -- ******************************************************************

    adGenFrPVCDayIntervalTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrPVCDayIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "The FR PVC Day Interval Table contains various statistics
                     collected by each Frame Relay PVC over the previous
                     7 days of operation. The past 7 days are broken
                     into completed 24-hour intervals.  Each row in
                     this table represents one such interval (identified by
                     adGenFrPVCIntervalNumber) and for one specific
                     interface (identifed by ifIndex and
                     adGenFrPVCDLCIIndex)."
         ::= { adGenFrPVC 8 }

    adGenFrPVCDayIntervalEntry OBJECT-TYPE
        SYNTAX      AdGenFrPVCDayIntervalEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "An entry in the FR PVC Day Interval table"
        INDEX       { ifIndex, adGenFrPVCDLCIIndex, adGenFrPVCDayIntervalNumber }
         ::= { adGenFrPVCDayIntervalTable 1 }

    AdGenFrPVCDayIntervalEntry ::= SEQUENCE {
        adGenFrPVCDayIntervalNumber                          INTEGER,
        adGenFrPVCDayIntervalTimeStamp                       DisplayString,
        adGenFrPVCDayIntervalInOctets                        Counter32,
        adGenFrPVCDayIntervalInPkts                          Counter32,
        adGenFrPVCDayIntervalInDiscards                      Counter32,
        adGenFrPVCDayIntervalOutOctets                       Counter32,
        adGenFrPVCDayIntervalOutPkts                         Counter32,
        adGenFrPVCDayIntervalOutDiscards                     Counter32,
        adGenFrPVCDayIntervalPktsFECN1In                     Counter32,
        adGenFrPVCDayIntervalPktsFECN1Out                    Counter32,
        adGenFrPVCDayIntervalPktsBECN1In                     Counter32,
        adGenFrPVCDayIntervalPktsBECN1Out                    Counter32,
        adGenFrPVCDayIntervalPktsDE1In                       Counter32,
        adGenFrPVCDayIntervalPktsDE1Out                      Counter32,
        adGenFrPVCDayIntervalOctetsDE1In                     Counter32,
        adGenFrPVCDayIntervalOctetsDE1Out                    Counter32
    }

    adGenFrPVCDayIntervalNumber OBJECT-TYPE
        SYNTAX      INTEGER (1..7)
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "A number between 1 and 7, where 1 is the most
                     recently completed 24-hour interval and 96 is the least
                     recently completed 24-hour interval (assuming that all
                     7 intervals are valid)."
        ::= { adGenFrPVCDayIntervalEntry 1 }
    
    adGenFrPVCDayIntervalTimeStamp OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Timestamp of the 15-minute interval"

        ::= { adGenFrPVCDayIntervalEntry 2 }

    adGenFrPVCDayIntervalInOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 3 }

    adGenFrPVCDayIntervalInPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 4 }

    adGenFrPVCDayIntervalInDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of received packets discarded on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 5 }

    adGenFrPVCDayIntervalOutOctets OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 7 }

    adGenFrPVCDayIntervalOutPkts OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 8 }

    adGenFrPVCDayIntervalOutDiscards OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of transmit packets discarded on the FR PVC."

        ::= { adGenFrPVCDayIntervalEntry 9 }

    adGenFrPVCDayIntervalPktsFECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 11 }

    adGenFrPVCDayIntervalPktsFECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Forward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 12 }

    adGenFrPVCDayIntervalPktsBECN1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 13 }

    adGenFrPVCDayIntervalPktsBECN1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Backward Explicit
                     Congestion Notification bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 14 }

    adGenFrPVCDayIntervalPktsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 15 }

    adGenFrPVCDayIntervalPktsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of packets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 16 }

    adGenFrPVCDayIntervalOctetsDE1In OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets received with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 17 }
    
    adGenFrPVCDayIntervalOctetsDE1Out OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The number of octets transmitted with the Discard Eligible
                     bit set to 1."
        ::= { adGenFrPVCDayIntervalEntry 18 }

    -- ******************************************************************
    -- The Frame Relay Slot Specific Table
    -- ******************************************************************

    adGenFrSlotTable OBJECT-TYPE
        SYNTAX      SEQUENCE OF AdGenFrSlotEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "This table provides frame relay group/bearer channel
                     and PVC slot specific information."
         ::= { adGenFrSlot 1 }

    adGenFrSlotEntry OBJECT-TYPE
        SYNTAX      AdGenFrSlotEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION "Slot specific Frame Relay Group information."
        INDEX       { adGenSlotInfoIndex }
         ::= { adGenFrSlotTable 1 }

    AdGenFrSlotEntry ::= SEQUENCE {
          adGenFrSlotGroupLastCreateError   DisplayString,
          adGenFrSlotPVCMaxNumber           Unsigned32,
          adGenFrSlotPVCCurrentNumber       Unsigned32
       }
   
    adGenFrSlotGroupLastCreateError OBJECT-TYPE
        SYNTAX      DisplayString
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The reason for the last error that occurred while attempting to
                     create an entry in the Frame Relay Group Table (adGenFrGroupTable)
                     on a specific slot."
     ::= { adGenFrSlotEntry 1 }
        
    adGenFrSlotPVCMaxNumber OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "Maximum number of allowed Frame Relay PVCs on this slot.  Each access
                     module provides a pool of available PVC resources that may
                     be assigned to any Frame Relay Group."
     ::= { adGenFrSlotEntry 2 }

    adGenFrSlotPVCCurrentNumber OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION "The current number of Frame Relay PVC resources currently in
                     use on this slot.  Each access module provides a pool of available PVC
                     resources that may be assigned to any Frame Relay Group.  This
                     object reports the number currently assigned to carry user data."
     ::= { adGenFrSlotEntry 3 }

    -- ******************************************************************
    -- Frame Relay Notifications
    -- ******************************************************************

    adGenFrGroupDownAlarmClr NOTIFICATION-TYPE
         OBJECTS { adTrapInformSeqNum,
                   sysName,
                   ifIndex,
                   ifOperStatus,
                   adTAeSCUTrapAlarmLevel,
                   adGenFrGroupLmiStatus
                 }
         STATUS  current
         DESCRIPTION
                 "A adGenFrGroupDownAlarm clear is sent when the local in-channel
                  signaling protocol indicates that it is in the active(2) state.
                  If Frame Relay signaling is disabled, then group LMI status is
                  based on the operStatus of the frame-relay group."

         	--#TYPE         "Major - Frame Relay Group Down - Cleared"
    	 	--#SUMMARY      "Frame Relay Group Down - Cleared"
    	 	--#SUMMARY      "cleared at shelf: %s, slot: %d, interface: %d"
    	 	--#ARGUMENTS    {1,2,3}
    	 	--#SEVERITY     "MAJOR"
    	 	--#GENERIC      6
    	 	--#CATEGORY     "Alarm Events"
    		--#SOURCE_ID    "A"
    	 	--#TIMEINDEX    0
          ::= { adGenFrAlarms 1 }

    adGenFrGroupDownAlarmAct NOTIFICATION-TYPE
         OBJECTS { adTrapInformSeqNum,
                   sysName,
                   ifIndex,
                   ifOperStatus,
                   adTAeSCUTrapAlarmLevel,
                   adGenFrGroupLmiStatus
                 }
         STATUS  current
         DESCRIPTION
                 "A adGenFrGroupDownAlarm active is sent when the local in-channel
                  signaling protocol indicates that it is in a state other than
                  active(2).  If Frame Relay signaling is disabled, then group 
                  LMI status is based on the operStatus of the frame-relay group."

         	--#TYPE         "Major - Frame Relay Group Down - Active"
    	 	--#SUMMARY      "Frame Relay Group Down - Active"
    	 	--#SUMMARY      "cleared at shelf: %s, slot: %d, interface: %d"
    	 	--#ARGUMENTS    {1,2,3,4}
    	 	--#SEVERITY     "MAJOR"
    	 	--#GENERIC      6
    	 	--#CATEGORY     "Alarm Events"
    		--#SOURCE_ID    "A"
    	 	--#TIMEINDEX    0
          ::= { adGenFrAlarms 2 }

    adGenFrDlciDownAlarmClr NOTIFICATION-TYPE
         OBJECTS { adTrapInformSeqNum,
                   sysName,
                   adGenFrPVCIfIndex,
                   adGenFrPVCDLCIIndex,
                   adTAeSCUTrapAlarmLevel,
                   adGenFrPVCState
                 }
         STATUS  current
         DESCRIPTION
                 "A adGenFrDlciDownAlarm clear is sent when data DLCI is in the
                  active(2) state and is capable of passing user traffic."

         	--#TYPE         "Minor - Frame Relay DLCI Inactive - Cleared"
    	 	--#SUMMARY      "Frame Relay DLCI Inactive - Cleared"
    	 	--#SUMMARY      "cleared at shelf: %s, slot: %d, interface: %d, dlci: %u"
    	 	--#ARGUMENTS    {1,2,3,4}
    	 	--#SEVERITY     "MINOR"
    	 	--#GENERIC      6
    	 	--#CATEGORY     "Alarm Events"
    		--#SOURCE_ID    "A"
    	 	--#TIMEINDEX    0
          ::= { adGenFrAlarms 3 }

    adGenFrDlciDownAlarmAct NOTIFICATION-TYPE
         OBJECTS { adTrapInformSeqNum,
                   sysName,
                   adGenFrPVCIfIndex,
                   adGenFrPVCDLCIIndex,
                   adTAeSCUTrapAlarmLevel,
                   adGenFrPVCState
                 }
         STATUS  current
         DESCRIPTION
                 "A adGenFrDlciDownAlarm clear is sent when data DLCI is in a
                  state other than active(2) and is incapable of passing user traffic."

         	--#TYPE         "Minor - Frame Relay DLCI Down - Active"
    	 	--#SUMMARY      "Frame Relay DLCI Down - Active"
    	 	--#SUMMARY      "cleared at shelf: %s, slot: %d, interface: %d, dlci: %u"
    	 	--#ARGUMENTS    {1,2,3,4}
    	 	--#SEVERITY     "MINOR"
    	 	--#GENERIC      6
    	 	--#CATEGORY     "Alarm Events"
    		--#SOURCE_ID    "A"
    	 	--#TIMEINDEX    0
          ::= { adGenFrAlarms 4 }
END