ADTRAN-GENERIC-BRIDGE-MIB

-- TITLE:     The ADTRAN GENERIC BRIDGING MIB
-- PRODUCT:   ADTRAN MSAP PRODUCTS
-- VERSION:   1.0
-- DATE:      02/11/2007
-- AUTHOR:    Peter Som de Cerff
-- STATUS:    PRELIMINARY
--
-- This MIB defines the object identifiers (OID) for the
-- ADTRAN GENERIC Bridge MIB objects
--
-- The generic bonding model follows the general approach of the
-- ATM IMA model published by the ATM Forum.
-- The intent is for the generic MIB described here to form the basis of multiple
-- bonding and bridging solutions, with helper MIBs as necessary for the
-- specific needs of each application.
-- Applications to be supported by this MIB include:
--      EFM Any Port Bonding
--      For this application, GenBridge provides the bonding layer model,
--      and GenEFM will continue to provide the statistics and alarm MIBs.
--  TR101 Aggregation
--      For this application, GenBridge provides the bridging layer model,
--      and GenTR101 will be created to provide bridge/port descriptors
--      and support any necessary statistics and alarm MIBs.
--  ML-PPP Cross-slot Bonding
--      Future helper MIB for stats and so forth.
--  ATM IMA Cross-slot Bonding
--      GenBridge provides the bonding layer, while the IMA MIB will
--      continue to provide the statistics and alarm MIBs.  Test and OAM needs TBD.
--  Ethernet Link Aggregation
--      Future consideration.
--  Ethernet Provider Bridging
--      Future consideration.
--  DSL Cross-slot Bonding
--      Should support Ethernet or ATM cross-slot bonding, akin to EFM or IMA
--  DS1 CES Transport
--      Will require PHYL cross-connect table, TBD.
--  DS0 CES Switching
--      Possible future consideration.
--
-- The intent is for this MIB to augment, but not in general to replace, the existing
-- Adtran GenEFM MIB and the ATM Forum IMA MIB (partially replaced).
-- This MIB is expected to augment the GenEthernet MIB, and to be augmented by
-- additional application-specific MIBs.
--
-- This MIB defines the following entities:
-- (1) Bridge table (for various bridging and bonding types)
-- (2) PHYL-Bridge mapping table (for adding physical links to bridges)
-- (3) PHYL assignment table (for displaying physical links)
-- (4) Easy Bridge Creation Table (simplified way of creating bridges in the bridge table)
-- (5) Bridge Name - IfIndex lookup table (specify a name and retrieve an IfIndex)
--
-- HISTORY:
-- 02/11/07 pcs STATUS: PRELIMINARY.
-- 03/01/07 pcs Updated structures and added details per comments.  STATUS: PRELIMINARY.
-- 03/12/07 djb Removed PHYL table. Changed "BridgeGroup" to "Bridge". Removed txId and rxId
--              from the Bridge table. Added PHYL-Bridge mapping table. Added a table to
--              display the available PHYLs in the system and their current status.
--              STATUS: PRELIMINARY
-- 03/16/07 aed Changed enum definition for textual convention adGenBridgeType.
--              Use "notProvisioned" rather than "default."
-- 03/28/07 aed Corrected module identity definition, and placed this MIB under genTa5k.
--              Corrected compiler warnings about mixing read-write and read-create columns
--              in the same table.
-- 04/04/07 aed Added a bridge type for link aggregation
--              Added new objects for bandwidth management.
--              Changed protection parameters to read-only.
-- 04/05/07 aed Modified indexing to correct errors found on smic compile.
--              Added a new bridge type for a mac-switched bridge.
-- 10/26/07 twc Removed "unknown" enum from AdGenBridgeOperStatus.
-- 11/08/07 twc Added enums noLinksInGroup(4) and upPartial(5) to AdGenBridgeOperStatus. This list now matches
--		AdGenEFMGroupStatus in genefm.mi2 mib.
-- 11/29/07 mcr Added protection alarms and fix AdGenBridgeManualSwitch to include enable/disable
-- 11/06/07 jga Added GenEasyBridge and GenBridgeNameLookup tables
-- 02/05/08 aed Fixed some errors found by the SMIC compiler.
-- 02/20/08 aed Changed adGenEasyBridgeStatusString to be 1..255.
--              Modified the type and description for adGenBridgeProtectionState
-- 02/25/08 twc Added adGenBridgeLockoutProtectionAlmACT and adGenBridgeLockoutProtectionAlmCLR Alarm Traps.
-- 03/07/08 twc Corrected adGenEasyBridgeMemberPhyls comment.
-- 04/23/08 twc Removed unnecessary import of SnmpAdminString, also added ifIndex import from IF-MIB.
-- 08/26/08 dcc Added ATM bridge type
--              DO NOT ADD REVISION INFORMATION HERE.
-- ******************************************************************************************

DEFINITIONS ::= BEGIN

    IMPORTS
        MODULE-IDENTITY, OBJECT-TYPE,
        TimeTicks, Integer32, Unsigned32,NOTIFICATION-TYPE
            FROM SNMPv2-SMI
        sysName
            FROM SNMPv2-MIB
        DisplayString, RowStatus, TEXTUAL-CONVENTION
            FROM SNMPv2-TC
        ifIndex,
        InterfaceIndex
            FROM IF-MIB
        adGenSlotInfoIndex
            FROM ADTRAN-GENSLOT-MIB
        adGenBridge, adGenBridgeID
            FROM ADTRAN-GENTA5K-MIB
        adTrapInformSeqNum
            FROM ADTRAN-GENTRAPINFORM-MIB
        adGenPortTrapIdentifier
            FROM ADTRAN-GENPORT-MIB
        ;

    adGenBridgeMIB MODULE-IDENTITY
        LAST-UPDATED "201112230000Z"
        ORGANIZATION
            "ADTRAN, Inc."
        CONTACT-INFO
            "CND Tech Support
                Postal: ADTRAN, Inc.
                        901 Explorer Blvd.
                        Huntsville, AL  35806
                        Tel: +1 800 726-8663
                        Fax: +1 256 963 6217
                        E-mail: support@adtran.com"
        DESCRIPTION
            "Generic Bridge MIB"
            
        REVISION "201112230000Z"
        DESCRIPTION  "Added new Table, adGenBridgeBulkInstanceTable, and OID,adGenBridgeBulkInstance, for TLV instance number"

        REVISION "201112010000Z"
        DESCRIPTION  "Added adGenBridgeCount "
        
        REVISION "201108100000Z"
        DESCRIPTION  "Added adGenBridgeSecondaryUpstreamRate and adGenBridgeSecondaryDownstreamRate"

        REVISION "201104180000Z"
        DESCRIPTION  "Added adGenBridgeAlarmSuppress"

        ::= {adGenBridgeID 1}

-- OBJECT IDENTIFIERS
adGenBridgeMIBObjects       OBJECT IDENTIFIER ::= {adGenBridge 1}
adGenEasyBridgeMIBObjects   OBJECT IDENTIFIER ::= {adGenBridge 2}
adGenBridgeAlarmsPrefix     OBJECT IDENTIFIER ::= {adGenBridge 3}
adGenBulkBridge             OBJECT IDENTIFIER ::= {adGenBridge 4}
adGenBridgeAlarms           OBJECT IDENTIFIER ::= {adGenBridgeAlarmsPrefix 0}


-- **********************************************************************
-- Textual Conventions
-- **********************************************************************
AdGenBridgeProtMode ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "Specifies the protection mode of a particular bridge.
             Unsupported indicates that the particular bridge cannot support
             protection. Unprotected indicates that the particular bridge
             could support protection but chooses not to."
        SYNTAX   INTEGER {
          unsupported(1),
          unprotected(2),
          protected(3)
          }

AdGenBridgeProtAvail ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "Indicates if the selected protection slot is available
             for protection switchover."
        SYNTAX   INTEGER {
          unsupported(1),
          unavailable(2),
          available(3)
          }

AdGenBridgeProtState ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "Indicates if the protection card is actively running this bonding
             group."
        SYNTAX   INTEGER {
          unsupported(1),
          unprotected(2),
          protected(3)
          }

AdGenBridgeOperStatus ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
           "The value determines the operational status of a
            bridge or cross-connect. The up and down
            states indicate that the traffic flow is enabled
            or disabled respectively on the bridge or
            cross-connect."
        SYNTAX   INTEGER {
           up(1),
           down(2),
           testing(3),
           noLinksInGroup(4),
           upPartial(5)
           }

AdGenBridgePhylOperStatus ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
           "The current operational status of the Bridge-PHYL
            mapping indicating if the physical link is actively
            participating in the Bridge. This can be down if the
            row status of the BridgePhyl Map entry is down, the
            row status of the Bridge is down, or the physical link is down."
        SYNTAX   INTEGER {
           up(1),
           down(2),
           testing(3),
           unknown(4)
           }

AdGenBridgeType ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "This value indicates the particular type of bridge, such
             as EFM, TR101, IMA, etc. The enumeration should be updated
             for each new bridge type that is created."
        SYNTAX   INTEGER {
           notProvisioned(1),
           efm(2),
           tr101(3),
           ima(4),
           linkAggregation(5),
           macSwitched(6),
           ppp(7),
           atm(8)
           }

AdGenBridgeRateControl ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "This value indicates the rate control is enabled or not"
        SYNTAX   INTEGER {
           rateControlOn(1),
           rateControlOff(2)
           }

AdGenBridgeLastChange ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "The value of MIB II's sysUpTime at the time a
            virtual link or cross-connect entered its current
            operational state. If the current state was
            entered prior to the last re-initialization of the
            agent then this object contains a zero value."
        SYNTAX   TimeTicks

AdGenBridgeAlarmSuppress ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Indicates whether or not alarms will be generated
                 by this interface.  It is only applicable if
                 rowStatus = active."
        SYNTAX  INTEGER {
                suppress(1),
                noSuppress(2)
                }

AdGenBridgePhylInstalled ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Indicates whether or not the physical interface
                 associated with this PHYL exists."
        SYNTAX  INTEGER {
                uninstalled(1),
                installed(2)
                }
-- **********************************************************************
-- Textual Conventions - Bonding Engine Protection Related
-- **********************************************************************
AdGenBridgeProtectionRevertiveSwitch ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Indicates whether Revertive Switch is enabled or disabled."
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }

AdGenBridgeProtectionLockout ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Indicates whether Lockout is enabled or disabled."
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }

AdGenBridgeManualSwitch ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
                "Triggers a switch to protected or Non Protected."
        SYNTAX  INTEGER {
                switchToProtect(1),
                switchToNonProtect(2)
                }

AdGenProtectionVersion ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "Version indicates the capacity of protection module. Whether the Protection
            Module is capable of protecting the Protected Modules. A higher version (capacity)
            Protection Module can be compatible with a lower version of Protected Modules."
        SYNTAX   INTEGER {
           notsupported(0),
           version1(1)
           }


-- **********************************************************************
-- Configuration
-- **********************************************************************
-- Module (card) level configuration table, indicates maximum values
-- supported by each card as well as the currently configured number

adGenBridgeModuleConfTable  OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgeModuleConfEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This table contains global bridge configuration
            parameters, per populated card slot."
          ::= { adGenBridgeMIBObjects 1 }

adGenBridgeModuleConfEntry    OBJECT-TYPE
          SYNTAX         AdGenBridgeModuleConfEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "This list contains bridge group limits per module ."
          INDEX { adGenSlotInfoIndex }
          ::= { adGenBridgeModuleConfTable  1}

AdGenBridgeModuleConfEntry    ::= SEQUENCE  {
          adGenBridgeModuleMaxBridges           INTEGER,
          adGenBridgeModuleMaxPhyls             INTEGER,
          adGenBridgeModuleConfBridges          INTEGER,
          adGenBridgeModuleConfPhyls            INTEGER,
          adGenBridgeModuleMaxBandwidth         Integer32,
          adGenBridgeModuleConfBandwidth        Integer32
          }

adGenBridgeModuleMaxBridges OBJECT-TYPE
          SYNTAX         INTEGER  (0..100)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The maximum number of bridges this module will support. "
          ::= { adGenBridgeModuleConfEntry 1}

adGenBridgeModuleMaxPhyls OBJECT-TYPE
          SYNTAX         INTEGER  (0..2200)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The total number of physical links that may be mapped to
            bridges on the module, including active and inactive mappings."
          ::= { adGenBridgeModuleConfEntry 2}

adGenBridgeModuleConfBridges OBJECT-TYPE
          SYNTAX         INTEGER  (0..100)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The current number of bridges configured on the module."
          ::= { adGenBridgeModuleConfEntry 3}

adGenBridgeModuleConfPhyls OBJECT-TYPE
          SYNTAX         INTEGER  (0..2200)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The total number of physical links currently mapped to
            bridges on the module, including in-service and
            out-of-service mappings."
          ::= { adGenBridgeModuleConfEntry 4}

adGenBridgeModuleMaxBandwidth OBJECT-TYPE
          SYNTAX        Integer32
          MAX-ACCESS    read-write
          STATUS        current
          DESCRIPTION
          "The maximum bandwith allocated for this module in kbps."
          ::= { adGenBridgeModuleConfEntry 5}

adGenBridgeModuleConfBandwidth OBJECT-TYPE
          SYNTAX        Integer32
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
          "The bandwidth currently being used by this module in kbps."
          ::= { adGenBridgeModuleConfEntry 6}
          
          
--==================================================================================================================
-- Bulk Bridge instance
--==================================================================================================================

    adGenBridgeBulkInstanceTable
     OBJECT-TYPE
       SYNTAX      SEQUENCE OF AdGenBridgeBulkInstanceEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Table contains instances that are created when there is a request to a bulk bridge instance."
       ::= { adGenBulkBridge 1 }

    adGenBridgeBulkInstanceEntry OBJECT-TYPE
       SYNTAX      AdGenBridgeBulkInstanceEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Index is the slot number."
       INDEX { adGenSlotInfoIndex }
       ::= { adGenBridgeBulkInstanceTable 1 }

    AdGenBridgeBulkInstanceEntry ::=
       SEQUENCE {
           adGenBridgeBulkInstance           Integer32
       }

    adGenBridgeBulkInstance     OBJECT-TYPE
       SYNTAX                           Integer32
       MAX-ACCESS                       read-only
       STATUS                           current
       DESCRIPTION
           "Used to index the TlV table; Each time this is called by slot it
            creates an instance for that viewer. Once an instance is created, it may
            be found by doing a get on adTa5kTlvBySlotInstance with the instance 
            number"
        ::= { adGenBridgeBulkInstanceEntry 1 }

-- **********************************************************************
-- Provisioning
-- **********************************************************************
-- Bridge entity, providing multi-link any port bonding of PHYL interfaces

adGenBridgeStatus OBJECT-TYPE
         SYNTAX         DisplayString
         MAX-ACCESS     read-only
         STATUS         current
         DESCRIPTION
             "Error status messages for Bridge entities."
         ::= { adGenBridgeMIBObjects 2 }

adGenBridgeTable         OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgeEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The Bridge table.  A unique Bridge is created
            for every bonding or bridging instance, with an associated
            type that determines its functionality."
          ::= { adGenBridgeMIBObjects 3}

adGenBridgeEntry         OBJECT-TYPE
          SYNTAX         AdGenBridgeEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the Bridge table.  This entry is
            used to model a single instance of an aggregation
            (bridging or bonding) engine."
          INDEX  {adGenBridgeIfIndex}
          ::= { adGenBridgeTable  1}

     AdGenBridgeEntry    ::= SEQUENCE  {
          adGenBridgeIfIndex               InterfaceIndex,
          adGenBridgeType                  AdGenBridgeType,
          adGenBridgeName                  DisplayString,
          adGenBridgeProtMode              AdGenBridgeProtMode,
          adGenBridgeProtAvail             AdGenBridgeProtAvail,
          adGenBridgeProtState             AdGenBridgeProtState,
          adGenBridgeProtSlot              Unsigned32,
          adGenBridgeMinNumActivePhyls     INTEGER,
          adGenBridgeOperStatus            AdGenBridgeOperStatus,
          adGenBridgeLastChange            AdGenBridgeLastChange,
          adGenBridgeNumCfgEVPLs           INTEGER,
          adGenBridgeNumCfgEVCLs           INTEGER,
          adGenBridgeNumCfgPhyls           INTEGER,
          adGenBridgeNumActPhyls           INTEGER,
          adGenBridgeLastError             DisplayString,
          adGenBridgeRowStatus             RowStatus,
          adGenBridgeMaxBandwidth          Integer32,
          adGenBridgeCurrentBandwidth      Integer32,
          adGenBridgeUpstreamRate          Unsigned32,
          adGenBridgeDownstreamRate        Unsigned32,
          adGenBridgeCurrentUpstreamRate   Unsigned32,
          adGenBridgeCurrentDownstreamRate Unsigned32,
          adGenBridgeRateControl           AdGenBridgeRateControl,
          adGenBridgeAlarmSuppress         AdGenBridgeAlarmSuppress,
          adGenBridgeSecondaryUpstreamRate    Unsigned32,
          adGenBridgeSecondaryDownstreamRate    Unsigned32
}

adGenBridgeIfIndex OBJECT-TYPE
          SYNTAX         InterfaceIndex
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The ifIndex value of the interface associated
            with this Bridge. The IANA type should be linegroup (210)."
          ::= { adGenBridgeEntry 1 }

adGenBridgeType OBJECT-TYPE
          SYNTAX         AdGenBridgeType
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "The intended type of this bridge EFM, IMA, TR-101, etc."
          ::= { adGenBridgeEntry 2 }

adGenBridgeName OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "The textual name given to this Bridge."
          ::= { adGenBridgeEntry 3 }

adGenBridgeProtMode OBJECT-TYPE
          SYNTAX         AdGenBridgeProtMode
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The protection mode of the group single-slot (not protectable),
             unprotected (but potentially protectable), or protected."
          ::= { adGenBridgeEntry 4 }

adGenBridgeProtAvail OBJECT-TYPE
        SYNTAX         AdGenBridgeProtAvail
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION
            "Indicates if the selected protection slot is available
             for protection switchover."
          ::= { adGenBridgeEntry 5 }

adGenBridgeProtState OBJECT-TYPE
        SYNTAX         AdGenBridgeProtState
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION
            "Indicates if the protection card is actively running this bridge."
          ::= { adGenBridgeEntry 6 }


adGenBridgeProtSlot OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "A bit map of Protection Module slots part of this Protection Group.
            Slot 1  0x00000001
            Slot 2  0x00000002
            Slot 3  0x00000004
            Slot 4  0x00000008
            Slot 5  0x00000010
                        |
                        |
            Slot 30 0x20000000
            Slot 31 0x40000000
            Slot 32 0x80000000
            For all slots ranging from slot 1 to 32 (inclusive of both), the
            value will be 0xFFFFFFFF (4294967295)"
          ::= { adGenBridgeEntry 7 }

adGenBridgeMinNumActivePhyls OBJECT-TYPE
          SYNTAX         INTEGER (1..16)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "The minimum number of active PHYLS that have
            to be mapped to this group before the OperStatus
            of the bridge can be declared to be 'up'.
            If the active number ever drops below this number
            then the Bridge will enter an OperStatus of 'down'"
          ::= { adGenBridgeEntry 8 }


adGenBridgeOperStatus    OBJECT-TYPE
          SYNTAX         AdGenBridgeOperStatus
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The current operational status of the local end of the group."
          ::= { adGenBridgeEntry 9}

adGenBridgeLastChange    OBJECT-TYPE
          SYNTAX         AdGenBridgeLastChange
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The value of sysUpTime at the time this
            Bridge group entered its current operational state."
          ::= { adGenBridgeEntry 10 }

adGenBridgeNumCfgEVPLs  OBJECT-TYPE
          SYNTAX         INTEGER  (0..4096)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of EVPLs currently assigned against the ifIndex
           of this bridge. This value is incremented by the agent
           upon the creation of an EVPL against this bridge and
           decremented upon the deletion of an EVPL that was assigned
           against this bridge."
          ::= { adGenBridgeEntry 11}

adGenBridgeNumCfgEVCLs  OBJECT-TYPE
          SYNTAX         INTEGER  (0..4096)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of EVCLs currently assigned against the ifIndex
           of this bridge. This value is incremented by the agent
           upon the creation of an EVCL against this bridge and
           decremented upon the deletion of an EVCL that was assigned
           against this bridge."
          ::= { adGenBridgeEntry 12}

adGenBridgeNumCfgPhyls  OBJECT-TYPE
          SYNTAX         INTEGER  (0..2200)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of PHYLs currently mapped to this bridge.
           This value is incremented by the agent upon the creation
           of a Bridge-PHYL mapping."
          ::= { adGenBridgeEntry 13}

adGenBridgeNumActPhyls  OBJECT-TYPE
          SYNTAX         INTEGER  (0..2200)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The number of PHYLs currently active
           as part of this group."
          ::= { adGenBridgeEntry 14}

adGenBridgeLastError OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The string describing the last error experienced."
          ::= { adGenBridgeEntry 15 }

adGenBridgeRowStatus  OBJECT-TYPE
          SYNTAX         RowStatus
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "This object is used to create a new row or modify or delete an
            existing row in this table. Setting this value to 'active'
            indicates that the Bridge is administratively In-Service.
            Setting this value to 'inactive' indicates that the
            Bridge is administratively 'Out-Of-Service'"
          DEFVAL  { active }
          ::= {adGenBridgeEntry 16}

adGenBridgeMaxBandwidth    OBJECT-TYPE
          SYNTAX        Integer32
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
          "The maximum bandwidth allocated for this bridge in kbps."
          ::= { adGenBridgeEntry 17 }

adGenBridgeCurrentBandwidth  OBJECT-TYPE
          SYNTAX        Integer32
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
          "The bandwith currently used by this bridge in kpbs."
          ::= { adGenBridgeEntry 18 }

adGenBridgeUpstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "The Upstream Rate configured on the bridge in kbps."
          ::= { adGenBridgeEntry 19 }

adGenBridgeDownstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "The Downstream Rate configured on the bridge in kbps."
          ::= { adGenBridgeEntry 20 }

adGenBridgeCurrentUpstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
            "The Upstream Rate current status on the bridge in kbps."
          ::= { adGenBridgeEntry 21 }

adGenBridgeCurrentDownstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
            "The Downstream Rate current status on the bridge in kbps."
          ::= { adGenBridgeEntry 22 }

adGenBridgeRateControl OBJECT-TYPE
          SYNTAX         AdGenBridgeRateControl
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "Mode that divides the bridge rates over the links.
             Bridge Rate Control On is 1
             Bridge Rate Control Off is 2"
          ::= { adGenBridgeEntry 23 }

adGenBridgeAlarmSuppress    OBJECT-TYPE
          SYNTAX         AdGenBridgeAlarmSuppress
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "Indicates whether or not alarms will be generated
             by this Bridge group.  It is only applicable if
             rowStatus = active."
          ::= { adGenBridgeEntry 24 }

adGenBridgeSecondaryUpstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "The Secondary Upstream Rate threshold configured on the bridge in kbps. This is only a threshold used to trigger an alarm.
             A non-zero value enables the alarm associated with the provisioned threshold, default is disabled (0)"
          ::= { adGenBridgeEntry 25 }

adGenBridgeSecondaryDownstreamRate OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
            "The Secondary Downstream Rate threshold configured on the bridge in kbps. This is only a threshold used to trigger an alarm.
             A non-zero value enables the alarm associated with the provisioned threshold, default is disabled (0)"
          ::= { adGenBridgeEntry 26 }

-- Bridge to Phyl mapping table.
adGenBridgePhylMapStatus OBJECT-TYPE
         SYNTAX         DisplayString
         MAX-ACCESS     read-only
         STATUS         current
         DESCRIPTION
             "Error status messages for Bridge-PHYL mappings."
         ::= { adGenBridgeMIBObjects 4 }

adGenBridgePhylMapTable OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgePhylMapEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "Row creation adds/maps the physical link to a bridge."
          ::= { adGenBridgeMIBObjects 5 }

 adGenBridgePhylMapEntry OBJECT-TYPE
          SYNTAX       AdGenBridgePhylMapEntry
          MAX-ACCESS   not-accessible
          STATUS       current
          DESCRIPTION
           "An entry in the PHYL Map table.
            This entry is represents one link that
            is associated with a bridge."

        INDEX { adGenBridgePhylMapBridgeIfIndex,
                adGenBridgePhylMapPhylIfIndex
              }
          ::= { adGenBridgePhylMapTable 1 }

     AdGenBridgePhylMapEntry ::= SEQUENCE {
          adGenBridgePhylMapBridgeIfIndex       InterfaceIndex,
          adGenBridgePhylMapPhylIfIndex         InterfaceIndex,
          adGenBridgePhylMapOperStatus          AdGenBridgePhylOperStatus,
          adGenBridgePhylMapLastChange          AdGenBridgeLastChange,
          adGenBridgePhylMapLastError           DisplayString,
          adGenBridgePhylMapRowStatus           RowStatus
          }

adGenBridgePhylMapBridgeIfIndex OBJECT-TYPE
          SYNTAX         InterfaceIndex
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The ifIndex value of the Bridge to which the physical link
            is mapped."
          ::= { adGenBridgePhylMapEntry 1 }

adGenBridgePhylMapPhylIfIndex OBJECT-TYPE
          SYNTAX         InterfaceIndex
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The ifIndex value of the physical link."
          ::= { adGenBridgePhylMapEntry 2 }

adGenBridgePhylMapOperStatus    OBJECT-TYPE
          SYNTAX         AdGenBridgePhylOperStatus
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The current operational status of the Bridge-PHYL mapping
            indicating if the physical link is actively participating
            in the Bridge. This can be down if the row status of the
            BridgePhyl Map entry is down, the row status of the Bridge
            is down, or the physical link is down."
          ::= { adGenBridgePhylMapEntry 3}

adGenBridgePhylMapLastChange    OBJECT-TYPE
          SYNTAX         AdGenBridgeLastChange
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The value of sysUpTime at the time this
            Bridge-PHYL mapping entered its current operational state."
          ::= { adGenBridgePhylMapEntry 4 }

adGenBridgePhylMapLastError OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The string describing the last error experienced."
          ::= { adGenBridgePhylMapEntry 5 }

adGenBridgePhylMapRowStatus  OBJECT-TYPE
          SYNTAX         RowStatus
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "This object is used to create a new row or modify or delete an
            existing row in this table. Creating a row adds the
            PHYL to the Bridge. Setting this value to 'active'
            indicates that the Bridge-PHYL mapping is
            administratively In-Service. Setting this value to
            'Not-In-Service' indicates that the PHYL will no longer
            participate in the bridge. This does not effect the physical link."
          DEFVAL  { active }
          ::= {adGenBridgePhylMapEntry 6}

-- Phyl Status table.
adGenBridgePhylStatusTable OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgePhylStatusEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
          "Displays the status of the available PHYLs in the system,
           including which Bridge (if any) a PHYL is associated.
           It also indicates the installed status of a certain
           PHYL."
          ::= { adGenBridgeMIBObjects 6 }

 adGenBridgePhylStatusEntry OBJECT-TYPE
          SYNTAX       AdGenBridgePhylStatusEntry
          MAX-ACCESS   not-accessible
          STATUS       current
          DESCRIPTION
           "An entry in the PHYL Status table.
            This entry is represents one link."

        INDEX { adGenBridgePhylStatusPhylIfIndex }
          ::= { adGenBridgePhylStatusTable 1 }

     AdGenBridgePhylStatusEntry ::= SEQUENCE {
          adGenBridgePhylStatusPhylIfIndex         InterfaceIndex,
          adGenBridgePhylStatusBridgeIfIndex       InterfaceIndex,
          adGenBridgePhylStatusBridgeType          AdGenBridgeType,
          adGenBridgePhylStatusInstallStatus       AdGenBridgePhylInstalled,
          adGenBridgePhylStatusOperStatus          AdGenBridgePhylOperStatus
          }


adGenBridgePhylStatusPhylIfIndex OBJECT-TYPE
          SYNTAX         InterfaceIndex
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The ifIndex value of the physical link. IANA type should be propVirtual(53)."
          ::= { adGenBridgePhylStatusEntry 1 }

adGenBridgePhylStatusBridgeIfIndex OBJECT-TYPE
          SYNTAX         InterfaceIndex
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The ifIndex value of the Bridge of which this
            physical link is apart. A value of '0' indicates
            that the link is currently not mapped to any
            Bridge.  IANA type should be linegroup(210)."
          ::= { adGenBridgePhylStatusEntry 2 }

adGenBridgePhylStatusBridgeType    OBJECT-TYPE
          SYNTAX         AdGenBridgeType
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "Indicates the type (if any) of bridge with which this PHYL is associated."
          ::= { adGenBridgePhylStatusEntry 3}

adGenBridgePhylStatusInstallStatus    OBJECT-TYPE
          SYNTAX         AdGenBridgePhylInstalled
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "Indicates whether or not the physical interface associated with this PHYL
            exists."
          ::= { adGenBridgePhylStatusEntry 4}

adGenBridgePhylStatusOperStatus    OBJECT-TYPE
          SYNTAX         AdGenBridgePhylOperStatus
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The current operational status of the Bridge-PHYL Mapping. This status
            should match the adGenBridgePhylMapOperStatus of the
            corresponding row in the adGenBridgePhylMapTable.
            The current operational status of the Bridge-PHYL
            mapping indicates if the physical link is actively
            participating in the Bridge. This can be down if the
            row status of the BridgePhyl Map entry is down, the
            row status of the Bridge is down, or the physical link is down."
          ::= { adGenBridgePhylStatusEntry 5}

-- **********************************************************************
-- Bonding Engine Protection Provisioning
-- **********************************************************************
adGenBridgeProtectionGroupIndexNext OBJECT-TYPE
      SYNTAX      INTEGER (1..10)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
        "Returns the next available Protection Group Index."
      ::= { adGenBridgeMIBObjects 7 }

adGenBridgeProtectionGroupStatus OBJECT-TYPE
         SYNTAX         DisplayString
         MAX-ACCESS     read-only
         STATUS         current
         DESCRIPTION
             "Error status messages for Protection Group Creation."
         ::= { adGenBridgeMIBObjects 8 }

adGenBridgeProtectionGroupTable         OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgeProtectionGroupEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The Bridge Protection Group table.  A unique Bridge Protection Group is created
            to protect bonding engine. This fecilitates creating a Protection Group and
            adding or removing Protection Slots (PM slots) and Protected Slots (AM slots) to or
            from an existing Protection Groups. The Protection or Protected slots can be added
            or removed when the Protection Group Row Status is in active state. The Last Error
            string will return the error message if for some reason the slots cannot be added
            (for e.g. Bridge Type mismatch) or the Protection Group cannot be created. There
            are no variables in this table that needs to be set before the row status can be
            set to active."
          ::= { adGenBridgeMIBObjects 9}

adGenBridgeProtectionGroupEntry         OBJECT-TYPE
          SYNTAX         AdGenBridgeProtectionGroupEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the Bridge Protection Group table.  This entry is
            used to model a protection group for a protection engine."
          INDEX  {adGenBridgeProtectionGroupGroupIndex}
          ::= { adGenBridgeProtectionGroupTable  1}

     AdGenBridgeProtectionGroupEntry    ::= SEQUENCE  {
          adGenBridgeProtectionGroupGroupIndex            INTEGER,
          adGenBridgeProtectionGroupBridgeType            AdGenBridgeType,
          adGenBridgeProtectionGroupName                  DisplayString,
          adGenBridgeProtectionGroupProtectingSlots       Unsigned32,
          adGenBridgeProtectionGroupProtectedSlots        Unsigned32,
          adGenBridgeProtectionGroupAddProtectingModule   INTEGER,
          adGenBridgeProtectionGroupAddProtectedModule    INTEGER,
          adGenBridgeProtectionGroupRmvProtectingModule   INTEGER,
          adGenBridgeProtectionGroupRmvProtectedModule    INTEGER,
          adGenBridgeProtectionGroupWaitToRestoreTime     INTEGER,
          adGenBridgeProtectionGroupLastError             DisplayString,
          adGenBridgeProtectionGroupRowStatus             RowStatus
          }

adGenBridgeProtectionGroupGroupIndex OBJECT-TYPE
          SYNTAX         INTEGER (1..10)
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "A unique value to identify this Bridge Protection Group."
          ::= { adGenBridgeProtectionGroupEntry 1 }

adGenBridgeProtectionGroupBridgeType OBJECT-TYPE
          SYNTAX         AdGenBridgeType
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "Indicates the type of bridge this Protection Group is created for.
           This must be compatible with the Protection and Protected Module slot
           bridge type."
          ::= { adGenBridgeProtectionGroupEntry 2 }

adGenBridgeProtectionGroupName OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "The textual name given to this Protection Group."
          ::= { adGenBridgeProtectionGroupEntry 3 }

adGenBridgeProtectionGroupProtectingSlots OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "A bit map of Protection Module slots part of this Protection Group.
           Displays the Protection Modules in this Protection Group.
            Slot 1  0x00000001
            Slot 2  0x00000002
            Slot 3  0x00000004
            Slot 4  0x00000008
            Slot 5  0x00000010
                        |
                        |
            Slot 30 0x20000000
            Slot 31 0x40000000
            Slot 32 0x80000000
            For all slots ranging from slot 1 to 32 (inclusive of both), the
            value will be 0xFFFFFFFF (4294967295)"
          ::= { adGenBridgeProtectionGroupEntry 4 }

adGenBridgeProtectionGroupProtectedSlots OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "A bit map of Bonding Engine slots to be protected (part of this Protection Group).
           Displays the Protecting Modules in this Protection Group.
            Slot 1  0x00000001
            Slot 2  0x00000002
            Slot 3  0x00000004
            Slot 4  0x00000008
            Slot 5  0x00000010
                        |
                        |
            Slot 30 0x20000000
            Slot 31 0x40000000
            Slot 32 0x80000000
            For all slots ranging from slot 1 to 32 (inclusive of both), the
            value will be 0xFFFFFFFF (4294967295)"
          ::= { adGenBridgeProtectionGroupEntry 5 }

adGenBridgeProtectionGroupAddProtectingModule OBJECT-TYPE
          SYNTAX         INTEGER (1..32)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "Add a Protecting Module (slot) to the Protection Group identified by
           adGenBridgeProtectionGroupIndex."
          ::= { adGenBridgeProtectionGroupEntry 6 }

adGenBridgeProtectionGroupAddProtectedModule OBJECT-TYPE
          SYNTAX         INTEGER (1..32)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "Add a Protected Module (slot) to the Protection Group identified by
           adGenBridgeProtectionGroupIndex."
          ::= { adGenBridgeProtectionGroupEntry 7 }

adGenBridgeProtectionGroupRmvProtectingModule OBJECT-TYPE
          SYNTAX         INTEGER (1..32)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "Remove a Protecting Module (slot) from the Protection Group identified by
           adGenBridgeProtectionGroupIndex."
          ::= { adGenBridgeProtectionGroupEntry 8 }

adGenBridgeProtectionGroupRmvProtectedModule OBJECT-TYPE
          SYNTAX         INTEGER (1..32)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "Remove a Protected Module (slot) from the Protection Group identified by
           adGenBridgeProtectionGroupIndex."
          ::= { adGenBridgeProtectionGroupEntry 9 }

adGenBridgeProtectionGroupWaitToRestoreTime OBJECT-TYPE
          SYNTAX         INTEGER(1..20)
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "In case of a revertive swicth, this indicates the time in minutes
           to wait before a switch back can take place. Wait To Restore time is
           set for the whole group and is applicable to all the Protected Slots
           (AMs) in the group."
          ::= { adGenBridgeProtectionGroupEntry 10 }

adGenBridgeProtectionGroupLastError OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The string describing the last error experienced provisioning the Protection Group
           or adding or removing Protection or Protected slots."
          ::= { adGenBridgeProtectionGroupEntry 11 }

adGenBridgeProtectionGroupRowStatus  OBJECT-TYPE
          SYNTAX         RowStatus
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "This object is used to create a new row or modify or delete an
            existing row in this table. Creating a row adds either a Protected Module or
            a Protecting Module to a Protection Group.
            Setting this value to 'active' indicates that the Protection Group is
            administratively In-Service. Setting this value to
            'Not-In-Service' indicates that the Protection Group will not function or
            the whole Protection Group is in Lockout."
          DEFVAL  { active }
          ::= {adGenBridgeProtectionGroupEntry 12}

adGenBridgeProtectionTable         OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgeProtectionEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The Bridge Protection table containing protection related provisioning
            for each of the Protected Modules or Protection Modules. This is
            a static table for all the slots in the system. The Protected Modules and
            Protection Modules forming a Protection Group are identified by the
            adGenBridgeProtectionGroupTable."
          ::= { adGenBridgeMIBObjects 10}

adGenBridgeProtectionEntry         OBJECT-TYPE
          SYNTAX         AdGenBridgeProtectionEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the Bridge Protection table. This entry is
            used to provision the protection related parameters for bonding
            engine protection. These parameters are provisioned for Protected
            Module slots and Protection Module slots. This is a static table, a
            row created for every slot in the system. These values are only
            meaningful if they are part of a protection group, otherwise they are
            ignored."
          INDEX  {adGenSlotInfoIndex}
          ::= { adGenBridgeProtectionTable  1}

     AdGenBridgeProtectionEntry    ::= SEQUENCE  {
          adGenBridgeProtectionGroupIndex            INTEGER,
          adGenBridgeProtectionBridgeType            AdGenBridgeType,
          adGenBridgeProtectionVersion               AdGenProtectionVersion,
          adGenBridgeProtectionSlot                  INTEGER,
          adGenBridgeProtectionState                 Integer32,
          adGenBridgeProtectionPriority              INTEGER,
          adGenBridgeProtectionRevertiveSwitch       AdGenBridgeProtectionRevertiveSwitch,
          adGenBridgeProtectionLockout               AdGenBridgeProtectionLockout,
          adGenBridgeProtectionManualSwitch          AdGenBridgeManualSwitch,
          adGenBridgeProtectionManualSwitchTime      INTEGER,
          adGenBridgeProtectionErrorStatus           DisplayString
          }

adGenBridgeProtectionGroupIndex OBJECT-TYPE
          SYNTAX         INTEGER (0..2147483647)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "Displays the Protection Group Index this slot is part of. If this slot
           is not part of any Protection Group, then this value will be zero."
          ::= { adGenBridgeProtectionEntry 1 }

adGenBridgeProtectionBridgeType OBJECT-TYPE
          SYNTAX         AdGenBridgeType
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This is the value read from the module that is plugged into the slot. If bridge
           type of this module is incompatible with the Bridge Type of the Protection
           Group this module is part of then an alarm will be generated. "
          ::= { adGenBridgeProtectionEntry 2 }

adGenBridgeProtectionVersion OBJECT-TYPE
          SYNTAX         AdGenProtectionVersion
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This must be compatible with Protection and Protected Modules. A higher
           version Protection Module can protect a lower or equal version Protected
           module. This versioning is done to make sure that the Protection Module
           has enough bandwidth capacity to protect the Protected Modules. This value
           is read from the module that is plugged into the slot."
          ::= { adGenBridgeProtectionEntry 3 }

adGenBridgeProtectionSlot OBJECT-TYPE
          SYNTAX         INTEGER (0..32)
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This is a read only value and indicates the slot number of this entry."
          ::= { adGenBridgeProtectionEntry 4 }

adGenBridgeProtectionState OBJECT-TYPE
          SYNTAX         Integer32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "This is a read only value and indicates state of the Protection or Protected Module.
            A value of zero indicates the module plugged into this slot is not being protected
            or is not protecting another module. A non-zero value indicates the module plugged
            into this slot is being protected or is protecting another module. A non-zero value
            contains the protecting module slot number and the protected module slot number
            encoded with in it. Least significant 16 bits indicate the protected module slot and
            most significant 16 bits indicate the protecting module slot."
          ::= { adGenBridgeProtectionEntry 5 }

adGenBridgeProtectionPriority OBJECT-TYPE
          SYNTAX         INTEGER (0..32)
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "This is the priority of the Protected Modules within the protection
           group in case priority protection is enabled. This value can be set to
           zero. If all the Protected Modules priority is set to zero then priority
           protection is disabled. Protected Modules with in a group can have equal
           priority. This item is not intended for the Protection Module and is ignored."
          ::= { adGenBridgeProtectionEntry 6 }

adGenBridgeProtectionRevertiveSwitch OBJECT-TYPE
          SYNTAX         AdGenBridgeProtectionRevertiveSwitch
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "Indicates whether revertive switch is enabled or not for this Protected
           Module. This item is not intended for the Protection Module and is ignored."
          ::= { adGenBridgeProtectionEntry 7 }

adGenBridgeProtectionLockout OBJECT-TYPE
          SYNTAX         AdGenBridgeProtectionLockout
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "Indicates whether lockout is enabled or not for this Module."
          ::= { adGenBridgeProtectionEntry 8 }

adGenBridgeProtectionManualSwitch OBJECT-TYPE
          SYNTAX         AdGenBridgeManualSwitch
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "Indicates whether to do a manual switch to protection or to manual switch
           back from protect. Not intended for the Protection Module and is ignored."
          ::= { adGenBridgeProtectionEntry 9 }

adGenBridgeProtectionManualSwitchTime OBJECT-TYPE
          SYNTAX         INTEGER(1..10)
          MAX-ACCESS     read-write
          STATUS         current
          DESCRIPTION
           "In case a manual switch is triggered, this time in minutes
           indicates for how long the manual switch will be in effect. This
           item is not intended for the Protection Module and is ignored."
          ::= { adGenBridgeProtectionEntry 10 }

adGenBridgeProtectionErrorStatus OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "Displays error status in case the manual switch command fails."
          ::= { adGenBridgeProtectionEntry 11 }

    -- ======================================================================
    --
    adGenEasyBridgeIndexNext OBJECT-TYPE
      SYNTAX      INTEGER (1..2147483647)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
        "Returns the next available EasyBridge index number."
      ::= { adGenEasyBridgeMIBObjects 1 }

    adGenEasyBridgeTable OBJECT-TYPE
       SYNTAX      SEQUENCE OF AdGenEasyBridgeEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Activation of a row in this table causes the TA5000 to perform the following:
            1) Verify that all pertinent parameters are set.
            2) Verify that there are resources available to perform the requested operation
            3) If resources are available then apply to the GenBridge and GenBridgePhylMap tables
            This table abstracts the user from internal bandwidth constraints, AM incompatabilities, and
            other TA5000 limitations that will change over time. If a requested operation cannot
            occur then the status string will be set with an appropriate error."
       ::= { adGenEasyBridgeMIBObjects 2 }

   adGenEasyBridgeEntry OBJECT-TYPE
       SYNTAX      AdGenEasyBridgeEntry
       MAX-ACCESS  not-accessible
       STATUS      current
       DESCRIPTION
           "Each entry corresponds to a different bridge. An entry will be deleted after 2 minutes of
           inactivity. This table is indexed by the values returned from the
           adGenEasyBridgeIndexNext OID."
       INDEX { adGenEasyBridgeIndex }
       ::= { adGenEasyBridgeTable 1 }

   AdGenEasyBridgeEntry ::=
       SEQUENCE {
           adGenEasyBridgeIndex              Integer32,
           adGenEasyBridgeName               DisplayString,
           adGenEasyBridgeType               AdGenBridgeType,
           adGenEasyBridgeCreateOrModify     INTEGER,
           adGenEasyBridgeUpstreamRate       Integer32,
           adGenEasyBridgeDownstreamRate     Integer32,
           adGenEasyBridgeMemberPhyls        DisplayString,
           adGenEasyBridgeMinNumActivePhyls  Integer32,
           adGenEasyBridgeStatusString       DisplayString,
           adGenEasyBridgeRowStatus          RowStatus,
           adGenEasyBridgeRateControl        AdGenBridgeRateControl,
           adGenEasyBridgeAddMemberPhyls     DisplayString,
           adGenEasyBridgeDeleteMemberPhyls  DisplayString
       }

   adGenEasyBridgeIndex OBJECT-TYPE
       SYNTAX       Integer32
       MAX-ACCESS   not-accessible
       STATUS       current
       DESCRIPTION
       "This is an arbitrary index assigned by the adGenEasyBridgeIndexNext
       OID."
       ::= { adGenEasyBridgeEntry 1 }

   adGenEasyBridgeName OBJECT-TYPE
       SYNTAX       DisplayString (SIZE (1..50))
       MAX-ACCESS   read-create
       STATUS       current
       DESCRIPTION
       "This object must be set before a row is activated whether this row is
       'Create' or 'Modify'. If it is 'Create' then this string will be set
       in the adGenBridgeName OID. If the row is 'Modify' then this name
       will only be used for lookup. Once a bridge is created the name
       may not be changed.
       DEFAULT: Empty String"
       ::= { adGenEasyBridgeEntry 2 }

    adGenEasyBridgeType OBJECT-TYPE
          SYNTAX         AdGenBridgeType
          MAX-ACCESS     read-create
          STATUS         current
          DESCRIPTION
           "The intended type of this bridge EFM, IMA, TR-101, etc."
          ::= { adGenEasyBridgeEntry 3 }

   adGenEasyBridgeCreateOrModify OBJECT-TYPE
       SYNTAX      INTEGER {
                     create(1),
                     modify(2)}
       MAX-ACCESS  read-create
       STATUS      current
       DESCRIPTION
       "This OID indicates if this row is attempting to create a new bridge
       or modify an existing one. If the mode is 'create' then the bridge will
       be created with the parameters in this table unless they are invalid
       (such as an unspecified name). If the mode is 'modify' then only those
       parameters that are not invalid will be applied.
       DEFAULT: create"
       ::= { adGenEasyBridgeEntry 4 }

    adGenEasyBridgeUpstreamRate OBJECT-TYPE
       SYNTAX          Integer32
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object specifies the rate of the bridge for the upstream direction in Kbps. This parameter
           helps the agent determine the location of the bridge as well as the
           rate of each of the links associated with this bridge. The rate must be
           non-zero on a 'create' operation.
           DEFAULT: 0"
         ::= { adGenEasyBridgeEntry 5 }

    adGenEasyBridgeDownstreamRate OBJECT-TYPE
       SYNTAX          Integer32
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object specifies the rate of the bridge for the downstream direction in Kbps. This parameter
           helps the agent determine the location of the bridge as well as the
           rate of each of the links associated with this bridge. The rate must be
           non-zero on a 'create' operation.
           DEFAULT: 0"
         ::= { adGenEasyBridgeEntry 6 }

    adGenEasyBridgeMemberPhyls OBJECT-TYPE
       SYNTAX      DisplayString
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object is a comma delimited string of ifIndices. Each ifIndices
           corresponds to a GenBridgePhyl that should be attached to the bridge.
           This string must contain at least one ifIndex on a 'create' operation. For
           example, if the user wanted to create a bridge with the following phyls
           slot 1/port 1, slot 1/port 5, slot 10/port 3, slot 21/port 14, the string that
           would represent this would be:
           '23910101,23910105,23911003,23912114'.
           DEFAULT: Empty String"
         ::= { adGenEasyBridgeEntry 7 }

    adGenEasyBridgeMinNumActivePhyls OBJECT-TYPE
       SYNTAX          Integer32
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object specifies the genBridgeMinNumActivePhyls value. It must
           always be at most the same number as phyls specified in
           adGenEasyBridgeMemberPhyls. If the number of phyls specified by
           adGenEasyBridgeMemberPhyls is greater than this object's value then
           the user is trying to indicate the notion of spare links. This number must
           be non-zero on a 'create' operation.
           DEFAULT: 0"
         ::= { adGenEasyBridgeEntry 8 }

    adGenEasyBridgeStatusString OBJECT-TYPE
       SYNTAX          DisplayString
       MAX-ACCESS      read-only
       STATUS          current
       DESCRIPTION
           "This object indicates the status of the last attempted activation of this
           row. It will indicate pass/fail status as well as reasons in the case of
           a failure."
         ::= { adGenEasyBridgeEntry 9 }

    adGenEasyBridgeRowStatus OBJECT-TYPE
       SYNTAX      RowStatus
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "For this row to go active all pertinent parameters must be set (see
           individual parameter descriptions) as well as the agent must
           be able to create a bridge or modify the selected bridge. If an activate
           fails then the adGenEasyBridgeStatusString will be populated with
           the failure reasons."
         ::= { adGenEasyBridgeEntry 10 }

    adGenEasyBridgeRateControl OBJECT-TYPE
       SYNTAX          AdGenBridgeRateControl
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           ""
         ::= { adGenEasyBridgeEntry 11 }

    adGenEasyBridgeAddMemberPhyls OBJECT-TYPE
       SYNTAX      DisplayString
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object is a comma delimited string of ifIndices. This OID is referred
           to when adGenEasyBridgeCreateOrModify is set to modify(2), which must be done
           prior to setting this OID. Each ifIndex corresponds to a GenBridgePhyl that
           should be added to the bridge. This string must contain at least one ifIndex.
           For example, if the user wants to add the following phyls to a bridge;
           slot 1/port 1, slot 1/port 5, slot 10/port 3, slot 21/port 14, the string
           that would represent this would be: '23910101,23910105,23911003,23921014'.
           DEFAULT: Empty String"
         ::= { adGenEasyBridgeEntry 12 }

    adGenEasyBridgeDeleteMemberPhyls OBJECT-TYPE
       SYNTAX      DisplayString
       MAX-ACCESS      read-create
       STATUS          current
       DESCRIPTION
           "This object is a comma delimited string of ifIndices. This OID is referred
           to when adGenEasyBridgeCreateOrModify is set to modify(2), which must be done
           prior to setting this OID. Each ifIndex corresponds to a GenBridgePhyl that
           should be delete from the bridge. This string must contain at least one ifIndex.
           For example, if the user wants to delete the following phyls from a bridge;
           slot 1/port 1, slot 1/port 5, slot 10/port 3, slot 21/port 14, the string
           that would represent this would be: '23910101,23910105,23911003,23921014'.
           DEFAULT: Empty String"
         ::= { adGenEasyBridgeEntry 13 }

-- Bridge Name Lookup Table - table indexed by the AdGenBridgeName and returns the ifIndex

adGenBridgeBridgeNameLookupStatus OBJECT-TYPE
         SYNTAX         DisplayString
         MAX-ACCESS     read-only
         STATUS         current
         DESCRIPTION
             "Error status messages for lookups."
         ::= { adGenBridgeMIBObjects 11 }

adGenBridgeNameLookupTable         OBJECT-TYPE
          SYNTAX         SEQUENCE OF AdGenBridgeNameLookupEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "The Bridge Name Lookup table. As each bridge receives a name
            it is inserted into a lookup table along with it's ifIndex."
          ::= { adGenBridgeMIBObjects 12}

adGenBridgeNameLookupEntry         OBJECT-TYPE
          SYNTAX         AdGenBridgeNameLookupEntry
          MAX-ACCESS     not-accessible
          STATUS         current
          DESCRIPTION
           "An entry in the Bridge Name Lookup table.  This entry is
            used to store the bridge IfIndex and indexed by the name."
          INDEX  {adGenBridgeNameLookupIndex}
          ::= { adGenBridgeNameLookupTable  1}

AdGenBridgeNameLookupEntry    ::= SEQUENCE  {
      adGenBridgeNameLookupIndex          DisplayString,
      adGenBridgeNameIfIndex              Unsigned32
}

adGenBridgeNameLookupIndex OBJECT-TYPE
          SYNTAX         DisplayString
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The sring name value of the the bridge enity"
          ::= { adGenBridgeNameLookupEntry 1 }

adGenBridgeNameIfIndex OBJECT-TYPE
          SYNTAX         Unsigned32
          MAX-ACCESS     read-only
          STATUS         current
          DESCRIPTION
           "The Bridge IfIndex that is retrieved from the table"
          ::= { adGenBridgeNameLookupEntry 2 }

adGenBridgeCount OBJECT-TYPE
        SYNTAX         Integer32
        MAX-ACCESS     read-only
        STATUS         current
        DESCRIPTION
            "The total number of bridges in the system."
        ::= { adGenBridgeMIBObjects 13 }

-- ******************************************************************************************

-- Alarms
--

-- ********************************************
-- Active/Clear Type Alarms
-- ********************************************

adGenBridgeNonProtectedAlmCLR    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Non-Protected"
    --#TYPE         "Minor - Non-Protected"
    --#SUMMARY      "Non-Protected Alarm "
    --#SUMMARY      "cleared at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 2}

adGenBridgeNonProtectedAlmACT    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Non-Protected"
    --#TYPE         "Minor - Non Protected"
    --#SUMMARY      "Non-Protected Alarm "
    --#SUMMARY      "detected at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 3}

adGenBridgeProtectedAlmCLR    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Protected"
    --#TYPE         "Minor - Protected"
    --#SUMMARY      "Protected Alarm "
    --#SUMMARY      "cleared at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 4}

adGenBridgeProtectedAlmACT    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Protected"
    --#TYPE         "Minor - Protected"
    --#SUMMARY      "Protected Alarm "
    --#SUMMARY      "detected at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 5}

adGenBridgeNeedsProtectionAlmCLR    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Needs-Protection"
    --#TYPE         "Major - Needs-Protection"
    --#SUMMARY      "Needs-Protection Alarm "
    --#SUMMARY      "cleared at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MAJOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 6}

adGenBridgeNeedsProtectionAlmACT    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Needs Protection"
    --#TYPE         "Major - Needs Protection"
    --#SUMMARY      "Needs-Protection Alarm "
    --#SUMMARY      "detected at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MAJOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 7}

adGenBridgeManualProtectionAlmCLR    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module ManualSwitch Protection"
    --#TYPE         "Minor - Protect-ManualSw"
    --#SUMMARY      "Protect-ManualSw Alarm "
    --#SUMMARY      "cleared at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 8}

adGenBridgeManualProtectionAlmACT    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module ManualSwitch Protection"
    --#TYPE         "Minor - Protect-ManaulSw"
    --#SUMMARY      "Protect-ManualSw Alarm "
    --#SUMMARY      "detected at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 9}

adGenBridgeLockoutProtectionAlmCLR    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Protection Lockout"
    --#TYPE         "Minor - Protection Lockout-OFPR"
    --#SUMMARY      "Protection Lockout Alarm "
    --#SUMMARY      "cleared at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 10}

adGenBridgeLockoutProtectionAlmACT    NOTIFICATION-TYPE
    OBJECTS         {
                    adTrapInformSeqNum,
                    sysName,
                    adGenSlotInfoIndex,
                    ifIndex
                    }
    STATUS          current
    DESCRIPTION
                    "Access Module Protection Lockout"
    --#TYPE         "Minor - Protection Lockout-OFPR"
    --#SUMMARY      "Protection Lockout Alarm "
    --#SUMMARY      "detected at shelf: %s, slot: %d and port: %d"
    --#ARGUMENTS    {1,2,3}
    --#SEVERITY     "MINOR"
    --#GENERIC      6
    --#CATEGORY     "Error Events"
    --#SOURCE_ID    "A"
    --#TIMEINDEX    0
    ::= {adGenBridgeAlarms 11}


END