CT-ELS10-27-MIB DEFINITIONS ::= BEGIN

    -- ctELS10-27mib.txt
    -- Revision: 01.00.07
    -- Part Number:
    -- Date: October 25, 1999

    -- Cabletron Systems, Inc.
    -- 35 Industrial Way, P.O. Box 5005
    -- Rochester, NH 03867-0505
    -- (603) 332-9400
    -- support@ctron.com
    --
    -- Copyright 1999 Cabletron System Inc.  All Rights Reserved.
    --
    -- Reproduction of this document is authorized on condition that this
    -- copyright notice is included.  This Cabletron Systems Inc. 
    -- SNMP Management Information Base Specification (Specification) embodies
    -- Cabletron Systems Inc. proprietary intellectual property.
    -- Cabletron Systems Inc. retains all title and ownership in
    -- the Specification, including any revisions.
    --
    -- It is Cabletron Systems Inc. intent to encourage the
    -- widespread use of this Specification in connection with the management
    -- of Cabletron Systems Inc. products. Cabletron Systems Inc. 
    -- grants vendors, end-users, and other interested parties a
    -- non-exclusive license to use this Specification in connection with the
    -- management of Cabletron Systems Inc. products.

    -- This Specification is supplied "AS IS," and Cabletron Systems Inc. 
    -- makes no warranty, either express or implied, as to the use,
    -- operation, condition, or performance of the Specification.

    -- This mib is part of the assigned enterprise MIB tree for Cabletron Systems.
    -- This mib provides management information for the ELS10 product line
    -- (specifically: ELS10-27TX and ELS10-27MDU), part of the SmartSTACK 
    -- product line.

IMPORTS

      OBJECT-TYPE
		  FROM RFC-1212

      DisplayString, sysObjectID, ifOutDiscards, ifInErrors, ifOutErrors
		FROM RFC1213-MIB

      Counter, Gauge, IpAddress,
      TimeTicks, enterprises
		FROM RFC1155-SMI
		PhysAddress FROM SNMPv2-TC

      dot1dStpDesignatedRoot, dot1dStpRootCost, dot1dStpRootPort,
      dot1dStpMaxAge, dot1dStpHelloTime, dot1dStpForwardDelay,
      dot1dStpPortDesignatedRoot, dot1dStpPortDesignatedBridge,
      dot1dStpPortDesignatedCost, dot1dStpPortDesignatedPort,
      dot1dStpPortState
		FROM BRIDGE-MIB

      TRAP-TYPE
		FROM RFC-1215;

	--  mgmt        OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
	--  mib           OBJECT IDENTIFIER ::= { mgmt 1 }
	--  directory     OBJECT IDENTIFIER ::= { internet 1 }
	--  experimental  OBJECT IDENTIFIER ::= { internet 3 }
	--  private       OBJECT IDENTIFIER ::= { internet 4 }
	--  enterprises   OBJECT IDENTIFIER ::= { private 1 }

	 sigma                                  OBJECT IDENTIFIER ::= { enterprises 97 }
	 sys                                            OBJECT IDENTIFIER ::= { sigma 1 }
	 els10-27                                      OBJECT IDENTIFIER ::= { sigma 9 }
	 els10-27hw                                     OBJECT IDENTIFIER ::= { els10-27 1 }
	 els10-27sw                                     OBJECT IDENTIFIER ::= { els10-27 2 }
	 els10-27admin                          OBJECT IDENTIFIER ::= { els10-27 3 }
	 els10-27swdis                          OBJECT IDENTIFIER ::= { els10-27 4 }
	 els10-27addr                                   OBJECT IDENTIFIER ::= { els10-27 5 }
	 els10-27if                                     OBJECT IDENTIFIER ::= { els10-27 6 }
	 els10-27dot3                                   OBJECT IDENTIFIER ::= { els10-27 7 }
	 els10-27uart                                   OBJECT IDENTIFIER ::= { els10-27 8 }
	 els10-27debug                          OBJECT IDENTIFIER ::= { els10-27 10 }
	 els10-27lpbk                                   OBJECT IDENTIFIER ::= { els10-27 11 }
	 els10-27proto                          OBJECT IDENTIFIER ::= { els10-27 12 }
	 els10-27trunk                          OBJECT IDENTIFIER ::= { els10-27 13 }
	 els10-27workgroup                      OBJECT IDENTIFIER ::= { els10-27 14 }
	 els10-27trapMgt                                OBJECT IDENTIFIER ::= { els10-27 15 }
	 els10-27pingMgt                                OBJECT IDENTIFIER ::= { els10-27 16 } 
	 els10-27traceMgt                       OBJECT IDENTIFIER ::= { els10-27 17 } 
	 els10-27volmirrorgroup         OBJECT IDENTIFIER ::= { els10-27 19 }
	 els10-27VlanBridgeConfig       OBJECT IDENTIFIER ::= { els10-27 20 }
    els10-27volipmgroup                 OBJECT IDENTIFIER ::= { els10-27 21 }
    els10-27voligmpgroup                OBJECT IDENTIFIER ::= { els10-27 22 }
	 els10-27FlowControlCtl         OBJECT IDENTIFIER ::= { els10-27 23 }



   -- Cabletron MIB
   -- System group
		
	sysID OBJECT-TYPE
		SYNTAX  INTEGER {
		 els10-27-bridge(7)
		}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { sys 1 }

	sysReset        OBJECT-TYPE
		SYNTAX  TimeTicks
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { sys 2 }

	sysTrapPort OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { sys 6 }


	--  HW Configuration Group


	els10-27hwDiagCode      OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hw 1 }

	els10-27hwManufData     OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hw 2 }

	els10-27hwPortCount     OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hw 3 }

	els10-27hwPortTable     OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxhwPortEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hw 4 }

	els10-27hwPortEntry     OBJECT-TYPE
		SYNTAX  LxhwPortEntry
		ACCESS          not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		INDEX     { els10-27hwPortIndex }
		::= { els10-27hwPortTable 1 }

	LxhwPortEntry ::= SEQUENCE {
			els10-27hwPortIndex
				INTEGER,
			els10-27hwPortType
				INTEGER,
			els10-27hwPortSubType
				INTEGER,
			els10-27hwPortDiagPassed
				INTEGER,
			els10-27hwAddr
				OCTET STRING
			}

	els10-27hwPortIndex     OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hwPortEntry 1 }

	els10-27hwPortType      OBJECT-TYPE
		SYNTAX  INTEGER {
							port-csma(1),
							port-uart(6),
							port-none(255)
			}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hwPortEntry 2 }

	els10-27hwPortSubType   OBJECT-TYPE
		SYNTAX  INTEGER { csmacd-tpx(13),
						  csmacd-100-tpx(16),
						  csmacd-100-fx(17),
			 uart-female-9pin(80),
			  no-information(255)
			}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hwPortEntry 3 }

	els10-27hwPortDiagPassed        OBJECT-TYPE
		SYNTAX  INTEGER { diag-passed(1), diag-failed(2) }
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hwPortEntry 4 }

	els10-27hwAddr  OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27hwPortEntry 5 }


    els10-27hwUpLink  OBJECT-TYPE
	 SYNTAX  INTEGER { true(1), false(2) }
	 ACCESS  read-only
	 STATUS  mandatory
	 DESCRIPTION
	   "Specifies whether the Up-Link I/O module is existed"
		 ::= { els10-27hw 5 }

	els10-27hwUpLinkManufData OBJECT-TYPE
	 SYNTAX  OCTET STRING
	 ACCESS  read-only
	 STATUS  mandatory
	 DESCRIPTION
	   "This is a 32-byte array which contains the part number, 
			serial number, and hardware revision level of the Up-Link 
			I/O module. This array is valid only when the els10-27hwUplink 
			is true. If els10-27hwUplink is false, it returns an error"
	 ::= { els10-27hw 6 }


	--  LXSW Configuration Group

	els10-27swNumber        OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27sw 1 }

	els10-27swFilesetTable  OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxswFilesetEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27sw 2 }

	els10-27swFilesetEntry  OBJECT-TYPE
		SYNTAX  LxswFilesetEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		INDEX { els10-27swIndex }
		::= { els10-27swFilesetTable 1 }

	LxswFilesetEntry ::= SEQUENCE {
			els10-27swIndex
				INTEGER,
			els10-27swDesc
				DisplayString,
			els10-27swCount
				INTEGER,
			els10-27swType
				OCTET STRING,
			els10-27swSizes
				OCTET STRING,
			els10-27swStarts
				OCTET STRING,
			els10-27swBases
				OCTET STRING,
			els10-27swFlashBank
				INTEGER
			}

	els10-27swIndex OBJECT-TYPE
	SYNTAX  INTEGER {
		    currently-executing(1),
		    next-boot(2)
		}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 1 }

	els10-27swDesc  OBJECT-TYPE
		SYNTAX  DisplayString
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 2 }

	els10-27swCount OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 3 }

	els10-27swType          OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 4 }

	els10-27swSizes OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 5 }

	els10-27swStarts        OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 6 }

	els10-27swBases OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 7 }

	els10-27swFlashBank     OBJECT-TYPE
	SYNTAX  INTEGER {
		    first-bank(1),
		    second-bank(2)
		}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27swFilesetEntry 8 }



	-- LXADMIN Group

	els10-27adminFatalErr   OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 1 }

	els10-27adminAnyPass  OBJECT-TYPE
		SYNTAX   OCTET STRING
		ACCESS   read-write
		STATUS   mandatory
		DESCRIPTION  
		" " 
	   ::= { els10-27admin 2 }

  els10-27adminGetPass  OBJECT-TYPE
	  SYNTAX   OCTET STRING
	  ACCESS   read-write
	  STATUS   mandatory
		DESCRIPTION  
		" " 
	  ::= { els10-27admin 3 }
								
	els10-27adminNMSIPAddr OBJECT-TYPE
		SYNTAX  IpAddress
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 4 }
									
	els10-27adminStorageFailure OBJECT-TYPE
		SYNTAX  INTEGER { true(1), false(2) }
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 7 }

  els10-27adminAuthenticationFailure OBJECT-TYPE
	   SYNTAX   IpAddress
	   ACCESS   read-only
	   STATUS   mandatory
		DESCRIPTION  
		" " 
	   ::= { els10-27admin 8 }

	els10-27adminNAMReceiveCongests  OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 10 }
									
	els10-27adminArpEntries  OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 11 }
									
	els10-27adminArpStatics OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 12 }
									
	els10-27adminArpOverflows   OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 13 }

	els10-27adminIpEntries   OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 14 }
									
	els10-27adminIpStatics   OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 15 }
									
	els10-27adminStaticPreference  OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 16 }

	els10-27adminRipPreference  OBJECT-TYPE
		SYNTAX   INTEGER
		ACCESS   read-write
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 17 }

	els10-27adminRipRouteDiscards  OBJECT-TYPE
		SYNTAX   Counter
		ACCESS   read-only
		STATUS   mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 18 }

	els10-27adminRebootConfig   OBJECT-TYPE
		SYNTAX  INTEGER {
						no-change(1),
						tftp-config(2),
						revert-to-defaults(3)
					}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 19 }

	els10-27adminDisableButton      OBJECT-TYPE
		SYNTAX  INTEGER  { true(1), false(2) }
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 21 }

	els10-27adminButtonSelection    OBJECT-TYPE
		SYNTAX  INTEGER {
						led-any-activity(1),
						led-rx-activity(2),
						led-tx-activity(3),
						led-any-collision(4),
						led-programmed(5),
						led-duplex(6),
						led-speed(7),
						led-mirror(8)
					}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 22 }

	els10-27adminLEDProgramOption   OBJECT-TYPE
		SYNTAX  INTEGER {
						program-led-any-error(1)
					}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27admin 23 }

	-- Software Distribution Group

	els10-27swdisDesc       OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
       DESCRIPTION
	"The description (0-32 bytes) of the software set currently
	 being downloaded, or a description of the software set last
	 downloaded since the els10-27 booted."
		::= { els10-27swdis 1 }

	els10-27swdisAccess     OBJECT-TYPE
		SYNTAX  INTEGER {
		    protected(1),
		    any-software(2)
		}
		ACCESS  read-write
		STATUS  mandatory
       DESCRIPTION
	"The version of software that may be downloaded. Attempts to
	 download other versions of software will be rejected. The
	 value for swdisAccess is embedded within the software files
	 that are to be distributed via TFTP. Its value may be
	 derived from the names of the software files. the NMS operator
	 may wish to use the following special values:
	 protected (1)  No software downloads will be accepted
	 any-software (2)  A software download of any version of new
	 software will be accepted - this is the factory default"
		::= { els10-27swdis 2 }

	els10-27swdisWriteStatus        OBJECT-TYPE
	SYNTAX  INTEGER {
		    in-progress(1),
		    success(2),
		    config-error(3),
		    flash-error(4),
		    config-and-flash-errors(5)
		}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION
	"The status of the erase/write operation."
		::= { els10-27swdis 3 }

	els10-27swdisConfigIp   OBJECT-TYPE
		SYNTAX  IpAddress
		ACCESS  read-write
		STATUS  mandatory
       DESCRIPTION
	"The IP address of the NMS (i.e., any IP host) that is allowed
	 to use TFTP to send/retrieve the configuration file of the
	 els10-27. A value of 0.0.0.0 (which is the factory specified
	 default) prevents any NMS from obtaining access, while a
	 value of 255.255.255.255 gives every NMS permission."
		::= { els10-27swdis 4 }

	els10-27swdisConfigRetryTime    OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
       DESCRIPTION
	"The number of seconds that the els10-27 will wait for an
	 acknowledgment before it retransmits an unacknowledged TFTP
	 data block. The factory specified default is 5 seconds."
		::= { els10-27swdis 5 }

	els10-27swdisConfigTotalTimeout OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
       DESCRIPTION
	"The number of seconds that the els10-27 will wait for an
	 acknowledgment to a data block before it cancels a TFTP
	 session. The factory specified default is 25 seconds."
		::= { els10-27swdis 6 }

	-- Address Configuration

	els10-27addrStatics     OBJECT-TYPE
		SYNTAX   Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 1 }

	els10-27addrDynamics    OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 2 }

	els10-27addrDynamicMax  OBJECT-TYPE
		SYNTAX  Gauge
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 3 }

	els10-27addrDynamicOverflows    OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 4 }

	els10-27addrFlags       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 5 }

	els10-27addrMAC OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 6 }

	els10-27addrPort        OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 7 }


	els10-27addrOperation   OBJECT-TYPE
	SYNTAX  INTEGER {
		    read-random(1),
		    read-next(2),
		    update(4),
		    delete(5),
		    read-block(6)
		}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 8 }

	els10-27addrIndex       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 9 }

	els10-27addrNext        OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 10 }


	els10-27addrBlockSize   OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 19 }

	els10-27addrBlock       OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27addr 20 }


	-- Interfaces Group


	els10-27ifTable OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxifEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27if 1  }

	els10-27ifEntry OBJECT-TYPE
		SYNTAX  LxifEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
	INDEX { els10-27ifIndex }
		::= { els10-27ifTable 1 }

	LxifEntry ::= SEQUENCE {
			els10-27ifIndex
				INTEGER,
			---els10-27ifRxCnt
			---	INTEGER,
			---els10-27ifTxCnt
			---	INTEGER,
			els10-27ifThreshold
				INTEGER,
			els10-27ifThresholdTime
				INTEGER,
			els10-27ifRxQueueThresh
				INTEGER,
			els10-27ifRxQueueThreshTime
				INTEGER,
			els10-27ifTxStormCnt
				INTEGER,
			els10-27ifTxStormTime
				TimeTicks,
			els10-27ifFunction
				INTEGER,
			els10-27ifRxHwFCSs
				Counter,
			els10-27ifRxQueues
				Counter,
			els10-27ifStatisticsTime
				TimeTicks,
		els10-27ifForwardedChars
				Counter,
			els10-27ifDescr
				DisplayString,
			els10-27ifGoodRxFrames
				Counter,
			els10-27ifGoodTxFrames
				Counter
			}

	els10-27ifIndex OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 1 }

---	els10-27ifRxCnt OBJECT-TYPE
---		SYNTAX  INTEGER
---		ACCESS  read-only
---		STATUS  mandatory
---		DESCRIPTION  
---		" " 
---		::= { els10-27ifEntry 2 }

---	els10-27ifTxCnt OBJECT-TYPE
---		SYNTAX  INTEGER
---		ACCESS  read-only
---		STATUS  mandatory
---		DESCRIPTION  
---		" " 
---		::= { els10-27ifEntry 3 }

	els10-27ifThreshold     OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 4 }

	els10-27ifThresholdTime OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 5 }

	els10-27ifRxQueueThresh OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 6 }

	els10-27ifRxQueueThreshTime     OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 7 }

	els10-27ifTxStormCnt    OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 8 }

	els10-27ifTxStormTime   OBJECT-TYPE
		SYNTAX  TimeTicks
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 9 }

	els10-27ifFunction      OBJECT-TYPE
		SYNTAX  INTEGER 
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 16 }

	els10-27ifRxHwFCSs      OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 18 }

	els10-27ifRxQueues      OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 19 }

	els10-27ifStatisticsTime        OBJECT-TYPE
		SYNTAX  TimeTicks
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 27 }

	els10-27ifForwardedChars        OBJECT-TYPE
	SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 28 }

	els10-27ifDescr OBJECT-TYPE
		SYNTAX  DisplayString
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27ifEntry 29 }

	els10-27ifGoodRxFrames  OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
		DESCRIPTION  
		" " 
	::= { els10-27ifEntry 30 }

	els10-27ifGoodTxFrames  OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS  mandatory
		DESCRIPTION  
		" " 
	::= { els10-27ifEntry 31 }

	--  Dot3 Group

	els10-27dot3Table       OBJECT-TYPE
		SYNTAX  SEQUENCE OF Lxdot3Entry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3 1 }

	els10-27dot3Entry       OBJECT-TYPE
		SYNTAX  Lxdot3Entry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
	INDEX { els10-27dot3Index }
		::= { els10-27dot3Table 1 }


	Lxdot3Entry ::= SEQUENCE {
				els10-27dot3Index
					INTEGER,
				els10-27dot3TPLinkOK
					INTEGER,
				els10-27dot3LedOn
					INTEGER,
				els10-27dot3RxCollisions
					Counter,
				els10-27dot3RxRunts
					Counter,
				els10-27dot3RxLateColls
					Counter,
				els10-27dot3TxJabbers
					Counter,
				els10-27dot3TxBabbles
					Counter,
				els10-27dot3TxCollisions
					Counter,
				els10-27dot3SpeedSelection
					INTEGER,
				els10-27dot3DuplexSelection
					INTEGER
				}

	els10-27dot3Index       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 1 }

	els10-27dot3TPLinkOK    OBJECT-TYPE
		SYNTAX  INTEGER { true(1), false(2) }
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 2 }

	els10-27dot3LedOn       OBJECT-TYPE
		SYNTAX  INTEGER { led-on(1), led-off(2) }
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 3 }

	els10-27dot3RxCollisions        OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 4 }

	els10-27dot3RxRunts     OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 5 }

	els10-27dot3RxLateColls OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 6 }

	els10-27dot3TxJabbers   OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 7 }

	els10-27dot3TxBabbles   OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 8 }

	els10-27dot3TxCollisions        OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 9 }

	els10-27dot3SpeedSelection      OBJECT-TYPE
		SYNTAX  INTEGER { speed-10mbit(1), speed-100mbit(2), speed-auto(3) }
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 13 }

	els10-27dot3DuplexSelection     OBJECT-TYPE
		SYNTAX  INTEGER { duplex-auto(1), duplex-half(2), duplex-full(3) }
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27dot3Entry 14 }

	-- UART Interface Group

	els10-27uartTable       OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxuartEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27uart 1 }

	els10-27uartEntry       OBJECT-TYPE
		SYNTAX  LxuartEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
	INDEX { els10-27uartIndex }
		::= { els10-27uartTable 1 }

	LxuartEntry ::= SEQUENCE {
				els10-27uartIndex
					INTEGER,
				els10-27uartBaud
					INTEGER,
				els10-27uartAlignmentErrors
					Counter,
				els10-27uartOverrunErrors
					Counter
				}

	els10-27uartIndex       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27uartEntry 1 }

	els10-27uartBaud        OBJECT-TYPE
	SYNTAX  INTEGER {
		    b2400-baud(3),
		    b4800-baud(4),
		    b9600-baud(5),
		    b19200-baud(6)
		}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27uartEntry 2 }

	els10-27uartAlignmentErrors     OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27uartEntry 3 }

	els10-27uartOverrunErrors       OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27uartEntry 4 }

	-- Debug Command Group

	els10-27debugStringID   OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debug 1 }

	els10-27debugString     OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debug 2 }

	els10-27debugTable      OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxdebugEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debug 3 }

	els10-27debugEntry      OBJECT-TYPE
		SYNTAX  LxdebugEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
	INDEX { els10-27debugIndex }
		::= { els10-27debugTable 1 }

	LxdebugEntry ::= SEQUENCE {
			els10-27debugIndex
				INTEGER,
			els10-27debugOperation
				INTEGER,
			els10-27debugBase
				INTEGER,
			els10-27debugLength
				INTEGER,
			els10-27debugData
				OCTET STRING
			}

	els10-27debugIndex      OBJECT-TYPE
		SYNTAX  INTEGER {
				debug-nam(1)
				}
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debugEntry 1 }

	els10-27debugOperation  OBJECT-TYPE
		SYNTAX  INTEGER {
		    examine(1),
		    modify(2)
		}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debugEntry 2 }

	els10-27debugBase       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debugEntry 3 }

	els10-27debugLength     OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debugEntry 4 }

	els10-27debugData       OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27debugEntry 5 }

	-- Loopback Command Group

	els10-27lpbkTable       OBJECT-TYPE
		SYNTAX  SEQUENCE OF LxlpbkEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbk 1 }

	els10-27lpbkEntry       OBJECT-TYPE
		SYNTAX  LxlpbkEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION  
		" " 
	INDEX { els10-27lpbkIndex }
		::= { els10-27lpbkTable 1 }

	LxlpbkEntry ::= SEQUENCE {
			els10-27lpbkIndex
				INTEGER,
			els10-27lpbkOperation
				INTEGER,
			els10-27lpbkDestAddr
				OCTET STRING,
			els10-27lpbkPktNum
				INTEGER,
			els10-27lpbkInterval
				TimeTicks,
			els10-27lpbkPktLength
				INTEGER,
			els10-27lpbkIncrements
				INTEGER,
			els10-27lpbkGoods
				Counter,
			els10-27lpbkErrorNoReceives
				Counter,
			els10-27lpbkErrorBadReceives
				Counter,
			els10-27lpbkErrorSize
				INTEGER,
			els10-27lpbkErrorSent
				OCTET STRING,
			els10-27lpbkErrorReceived
				OCTET STRING,
			els10-27lpbkErrorOffset
				INTEGER
			}

	els10-27lpbkIndex       OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 1 }

	els10-27lpbkOperation   OBJECT-TYPE
	SYNTAX  INTEGER {
		    loopback-off(1),
		    loopback-local(2),
		    loopback-remote(3)
		}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 2 }

	els10-27lpbkDestAddr    OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 3 }

	els10-27lpbkPktNum      OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 4 }

	els10-27lpbkInterval    OBJECT-TYPE
		SYNTAX  TimeTicks
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 5 }

	els10-27lpbkPktLength   OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 6 }

	els10-27lpbkIncrements  OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 7 }

	els10-27lpbkGoods       OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 8 }

	els10-27lpbkErrorNoReceives     OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 9 }

	els10-27lpbkErrorBadReceives    OBJECT-TYPE
		SYNTAX  Counter
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 10 }

	els10-27lpbkErrorSize   OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 11 }

	els10-27lpbkErrorSent   OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 12 }

	els10-27lpbkErrorReceived       OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 13 }

	els10-27lpbkErrorOffset OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION  
		" " 
		::= { els10-27lpbkEntry 14 }



	--  Protocols Group

els10-27protoTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF LxprotoEntry
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
	  "This table contains configuration information specify-
	  ing the types of protocols used to bridge, route,
	  translate, and filter frames for each port."
     ::= { els10-27proto 1 }

els10-27protoEntry OBJECT-TYPE
     SYNTAX  LxprotoEntry
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
	  "Each entry in this table specifies which protocols are
	  used by a particular port in the ES/1."
     INDEX { els10-27protoIfIndex }
     ::= { els10-27protoTable 1 }

LxprotoEntry ::=
     SEQUENCE { 
			els10-27protoIfIndex
				 INTEGER,
	  els10-27protoBridge
	     INTEGER,
	  els10-27protoSuppressBpdu
	     INTEGER,
	  els10-27protoRipListen
	     INTEGER,
	  els10-27protoTrunking
	     INTEGER,
	  els10-27sprotoTransmitPacing 
	     INTEGER
     }

els10-27protoIfIndex OBJECT-TYPE
	  SYNTAX  INTEGER
	  ACCESS  read-only
	  STATUS  mandatory
	  DESCRIPTION
			 "Identifies the interface (port) to which this entry's
			 information belongs. The value of this variable
			 corresponds to ifIndex, as well as most of the other
			 port identification values in related MIBs."
	  ::= { els10-27protoEntry 1 }

els10-27protoBridge OBJECT-TYPE
     SYNTAX  INTEGER { transparent(1), none(4) }
     ACCESS  read-write
     STATUS  mandatory
     DESCRIPTION
	  "Defines the bridging method to be applied to frames
	  received at, or destined for, this port. Ethernet and
	  FDDI ports may be configured for transparent, srt, or
	  none.  Token Ring ports may be configured for any of
	  the four options. The UART may only be configured to
	  none."
     ::= { els10-27protoEntry 2 }

els10-27protoSuppressBpdu OBJECT-TYPE
     SYNTAX  INTEGER { normal(1), suppressed(2) }
     ACCESS  read-write
     STATUS  mandatory
     DESCRIPTION
	  "Allows transmission of spanning tree protocol packets
	  to be suppressed.  If normal(1), 802.1d spanning tree
	  packets are
	  transmitted as usual. If suppressed(2), these packets
	  are not transmitted. This option may be needed for in-
	  teroperability with non-802.1d spanning tree protocols
	  (e.g., DEC LanBridge 100)."
     ::= { els10-27protoEntry 3 }

els10-27protoRipListen OBJECT-TYPE
     SYNTAX  INTEGER { enabled(1), disabled(2) }
     ACCESS  read-write
     STATUS  mandatory
     DESCRIPTION
	  "Specifies whether the port should listen for internet
	  Routing Information Protocol (RFC-1058) packets, in order to
	  build the routing table for the unit."
     ::= { els10-27protoEntry 4 }

els10-27protoTrunking OBJECT-TYPE
     SYNTAX  INTEGER { enabled(1), disabled(2) }
     ACCESS  read-write
     STATUS  mandatory
     DESCRIPTION
	  "Specifies whether SMC's trunking protocol (an extension
	  to the standard Spanning Tree) is to be used over this port."
     ::= { els10-27protoEntry 5 }

els10-27sprotoTransmitPacing OBJECT-TYPE
     SYNTAX  INTEGER { enabled(1), disabled(2) }
     ACCESS  read-write
     STATUS  mandatory
     DESCRIPTION
	  "When enabled, introduces delays into normal transmission of frames, to
		   reduce the probability of collisions during heavy traffic."
     ::= { els10-27protoEntry 6 }

	--  Trunking Group


els10-27trunkTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF LxtrunkEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"This table describes the trunking status and attributes of
		 the interfaces that are configured for bridge trunking."
	::= { els10-27trunk 1 }

els10-27trunkEntry OBJECT-TYPE
	SYNTAX  LxtrunkEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION
		"An entry exists in this table for each physical interface
		 (port) that is configured for trunking."
	INDEX { els10-27trunkIfIndex }
	::= { els10-27trunkTable 1 }

	LxtrunkEntry ::=
		SEQUENCE {
			els10-27trunkIfIndex
				INTEGER,
			els10-27trunkState
				INTEGER,
			els10-27trunkRemoteBridgeAddr
				OCTET STRING,
			els10-27trunkRemoteIp
				IpAddress,
			els10-27trunkLastError
				INTEGER,
			els10-27trunkLinkOrdinal
				INTEGER,
			els10-27trunkLinkCount
				INTEGER,
			els10-27trunkLastChange
				INTEGER
			}

els10-27trunkIfIndex OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"Identifies a physical interface (port) which is
		configured for LAN trunking. The value of this variable
		corresponds to ifIndex, as well as most of the other
		port identification values in related MIBs."
	::= { els10-27trunkEntry 1 }

els10-27trunkState OBJECT-TYPE
	SYNTAX  INTEGER { off(1),
		      closed(2),
		      oneway(3),
		      joined(4),
		      perturbed(5),
		      helddown(6),
		      broken(7) }
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		 "If off(1) then this link has not been enabled for trunking.
		 If closed(2) then this link has not yet received any Trunking
		 PDUs. If oneway(3) then incoming Trunking PDUs do not indicate
		 that our PDUs are being successfully received by the far end.
		 If joined(4) then this link is actively participating in the
		 trunk group. If perturbed(5) then this link is actively
	 participating in the trunk group;  however, the transmission of
	 data packets has been temporarily stopped due to a change in
	 membership of the group.  If helddown(6) then an error has been
		 detected and the link is being held out-of-service until the error
		 clears.  If broken(7) then this link has been configured for trunking,
	 but the port is physically non-operational."
	::= { els10-27trunkEntry 2 }

els10-27trunkRemoteBridgeAddr OBJECT-TYPE
	SYNTAX  OCTET STRING
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The MAC address portion of the bridge ID of the remote bridge."
	::= { els10-27trunkEntry 3 }

els10-27trunkRemoteIp OBJECT-TYPE
	SYNTAX  IpAddress
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The IP address of the remote bridge, as reported by that
		 bridge for administrative purposes."
	::= { els10-27trunkEntry 4 }

els10-27trunkLastError OBJECT-TYPE
	SYNTAX  INTEGER { none(1),
		      in-bpdu(2),
		      multiple-bridges(3),
		      ack-lost(4),
		      standby(5),
		      too-many-groups(6),
		      no-ack(7),
		      perturbed-threshold(8),
		      self-connect(9),
		      port-moved(10),
					  multiple-lan-types(11) }
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The last reason for failure when the link is in closed, oneway, or helddown state."
	::= { els10-27trunkEntry 5 }

els10-27trunkLinkOrdinal OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The position of this link within the trunk group."
	::= { els10-27trunkEntry 6 }

els10-27trunkLinkCount OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of links within the trunk group."
	::= { els10-27trunkEntry 7 }

els10-27trunkLastChange OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION
		"The number of seconds since els10-27trunkState changed."
	::= { els10-27trunkEntry 8 }

    --  Workgroup Group

els10-27WorkGroupNextNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The next available workgroup number to be used.  When creating
	 a new workgroup, it is recommended to read the value of the variable
	 and use it to key into the workgroup table."
    ::= { els10-27workgroup 1 }

els10-27WorkGroupCurrentCount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The total number of workgroups currently defined."
    ::= { els10-27workgroup 2 }

els10-27WorkGroupMaxCount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The maximum number of workgroups allowed."
    ::= { els10-27workgroup 3 }

els10-27WorkGroupTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF LxWorkGroupEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
	"This table contains work group definitions for the interfaces."
    ::= { els10-27workgroup 4 }

els10-27WorkGroupEntry OBJECT-TYPE
    SYNTAX  LxWorkGroupEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
	"Each entry in this table contains a definition of a work group."
    INDEX   { els10-27WorkGroupNumber }
    ::= { els10-27WorkGroupTable 1 }

    LxWorkGroupEntry ::= 
	SEQUENCE {
	    els10-27WorkGroupNumber
		INTEGER,
	    els10-27WorkGroupName
		DisplayString,
	    els10-27WorkGroupPorts
		OCTET STRING,
	    els10-27WorkGroupType
		INTEGER
	    }

els10-27WorkGroupNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"An integer that identifies the work group, used as an index
	 to this table."
    ::= { els10-27WorkGroupEntry 1 }

els10-27WorkGroupName   OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"A 1-16 character work group name."
    ::= { els10-27WorkGroupEntry 2 }    

els10-27WorkGroupPorts OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"A list of all ports within the group.  The first
	 octet specified ports 1-8, the second 9-16, etc."
    ::= { els10-27WorkGroupEntry 3 }    

els10-27WorkGroupType OBJECT-TYPE
    SYNTAX  INTEGER { all(3), -- all broadcast packets
		      invalid(4) } -- to delete this group
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"The type of work group:
	 all - no additional information needs to be supplied."
    ::= { els10-27WorkGroupEntry 4 }    

	--  Trap Group

els10-27trapControlTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF LxtrapControlEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
	"This table contains information about the severity of each trap
	 and whether the trap is currently enabled."
    ::= { els10-27trapMgt 1 }         

els10-27trapControlEntry OBJECT-TYPE
    SYNTAX  LxtrapControlEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION  
	   " " 
    INDEX   { els10-27trapIndex }
    ::= { els10-27trapControlTable 1 }

    LxtrapControlEntry ::= 
	SEQUENCE {
	    els10-27trapIndex
		INTEGER,
	    els10-27trapEnabled
		INTEGER,
	    els10-27trapSeverity
		INTEGER,
	    els10-27trapText
		DisplayString
	    }

els10-27trapIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The specific trap number."
    ::= { els10-27trapControlEntry 1 }

els10-27trapEnabled OBJECT-TYPE
    SYNTAX  INTEGER { true(1), false(2) }        
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"Enable or disable the generation of this trap."
    ::= { els10-27trapControlEntry 2 }

els10-27trapSeverity OBJECT-TYPE
    SYNTAX  INTEGER { informational(1),
		      warning(2),
		      minor(3),
		      major(4),
		      critical(5) }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"A user-definable severity, indicating the importance of the
	 trap."
    ::= { els10-27trapControlEntry 3 }

els10-27trapText OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"A description of the trap."
    ::= { els10-27trapControlEntry 4 }

els10-27trapSeverityControlTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF LxtrapSeverityControlEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
	"This table contains information about whether a class of
	 traps of a particular severity are enabled or disabled."
    ::= { els10-27trapMgt 2 }

els10-27trapSeverityControlEntry OBJECT-TYPE
    SYNTAX  LxtrapSeverityControlEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION  
	    " " 
    INDEX   { els10-27trapSeverity }
    ::= { els10-27trapSeverityControlTable 1 }

    LxtrapSeverityControlEntry ::= 
	SEQUENCE {
	    els10-27trapSeverityControlSeverity
		INTEGER,
	    els10-27trapSeverityEnable
		INTEGER
	    }

els10-27trapSeverityControlSeverity OBJECT-TYPE
    SYNTAX  INTEGER { informational(1),
		      warning(2),
		      minor(3),
		      major(4),
		      critical(5) }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"A user-definable severity, indicating the importance of the
	 trap."
    ::= { els10-27trapSeverityControlEntry 1 }

els10-27trapSeverityEnable OBJECT-TYPE
    SYNTAX  INTEGER { enabled(1), disabled(2) }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"Enable or disable all traps of a given severity level."
    ::= { els10-27trapSeverityControlEntry 2 }

els10-27trapIncludeText OBJECT-TYPE
    SYNTAX  INTEGER { true(1), false(2) }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"Whether or not a formatted text string is included in the trap
	 PDU."
    ::= { els10-27trapMgt 3 }

els10-27trapTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"The time, in centiseconds, which should expire between the sending
	 of traps."
    -- DEFVAL { 100 }
    ::= { els10-27trapMgt 4 }

els10-27trapRetry OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
	"The number of times any enterprise-specific trap is to be sent for
	 a given event.  PDUs are retried using a truncated exponential backoff:
	 2 seconds, 4 seoncs, 8 seconds, 16 seconds, and then 32 seconds for
	 all succeeding intervals."
    -- DEFVAL { 1 }
    ::= { els10-27trapMgt 5 }

els10-27trapNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The number of traps that are in the els10-27trapTable."
    ::= { els10-27trapMgt 6 }

els10-27trapTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF LxtrapEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
	"This table contains the latest traps that have been generated."
    ::= { els10-27trapMgt 7 }

els10-27trapEntry OBJECT-TYPE
    SYNTAX  LxtrapEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION  
	    " " 
    INDEX   { els10-27trapEntryIndex }
    ::= { els10-27trapTable 1 }

    LxtrapEntry ::= 
	SEQUENCE {
	    els10-27trapEntryIndex
		INTEGER,
	    els10-27trapEntryTimeStamp
		TimeTicks,
	    els10-27trapEntryText
		DisplayString,
	    els10-27trapEntryNumber
		INTEGER,
	    els10-27trapEntrySeverity
		INTEGER
	    }

els10-27trapEntryIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"A number representing the order in which the trap occurred
	 in time.  This 32 bit number can wrap."
    ::= { els10-27trapEntry 1 }

els10-27trapEntryTimeStamp OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The time at which the trap occurred."
    ::= { els10-27trapEntry 2 }

els10-27trapEntryText OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"A description of the trap."
    ::= { els10-27trapEntry 3 }

els10-27trapEntryNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"The specific trap number, as specified in the TRAP PDU."
    ::= { els10-27trapEntry 4 }

els10-27trapEntrySeverity OBJECT-TYPE
    SYNTAX  INTEGER { informational(1),
		      warning(2),
		      minor(3),
		      major(4),
		      critical(5) }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
	"A user-definable severity, indicating the importance of the
	 trap."
    ::= { els10-27trapEntry 5 }


	--  Ping Management MIB


	els10-27pingDataTimeout OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The time, in centiseconds, from the last ping activity (a send
			or receive of an ECHO_RESPONSE or ECHO_REQUEST
			message), to when the els10-27pingEntry information for that ping
			request will be deleted."
	::= {els10-27pingMgt 1}

	els10-27pingTable OBJECT-TYPE
		SYNTAX          SEQUENCE OF LxpingEntry
		ACCESS          not-accessible
		STATUS          mandatory
		DESCRIPTION
			"The set of information describing the active ping requests and
			their results."
	::= {els10-27pingMgt 2}

	els10-27pingEntry OBJECT-TYPE
		SYNTAX          LxpingEntry
		ACCESS          not-accessible
		STATUS          mandatory
		DESCRIPTION
			"The parameters, state, and results of a ping request."
		INDEX           { els10-27pingNMSAddr,els10-27pingDestAddr }
	::= {els10-27pingTable 1}

	LxpingEntry ::= SEQUENCE {
		els10-27pingNMSAddr
			IpAddress,
		els10-27pingDestAddr
			IpAddress,
		els10-27pingState
			INTEGER,
		els10-27pingCount
			INTEGER,
		els10-27pingDataSize
			INTEGER,
		els10-27pingWait
			TimeTicks,
		els10-27pingTimeOut
			TimeTicks,
		els10-27pingOperation
			INTEGER,
		els10-27pingMin
			TimeTicks,
		els10-27pingMax
			TimeTicks,
		els10-27pingAvg
			TimeTicks,
		els10-27pingNumTransmitted
			INTEGER,
		els10-27pingNumReceived
			INTEGER
	}

	els10-27pingNMSAddr OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The IP address of the NMS, used to determine which ping
			request to return information on."
	::= {els10-27pingEntry 1}

	els10-27pingDestAddr OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The IP address which is to be the destination of the ping
			ECHO_REQUEST. This variable cannot be set while
			els10-27pingOperation is on."
	::= {els10-27pingEntry 2}

	els10-27pingState OBJECT-TYPE
		SYNTAX          INTEGER {
				not-started(0),
				active (1),
				timed-out (2),
				completed (3)}
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The current state of the ping request. "
	::= {els10-27pingEntry 3}

	els10-27pingCount OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The number of ping requests which are to be sent. This
			variable cannot be set while els10-27pingOperation is on."
	::= { els10-27pingEntry 4}

	els10-27pingDataSize OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The datagram packet size which will be sent with the
			ECHO_REQUEST, in bytes. This variable cannot be set while
			els10-27pingOperation is on."
	::= { els10-27pingEntry 5}

	els10-27pingWait OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The time, in centiseconds, between the sending of each
			ECHO_REQUEST message. This variable cannot be set while
			els10-27pingOperation is on."
	::= { els10-27pingEntry 6}

	els10-27pingTimeOut OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The time, in centiseconds, since the last ECHO_RESPONSE
			was received (or the last ECHO_REQUEST was sent, if there
			have been no responses) when the ping request will time out.
			This variable cannot be set while els10-27pingOperation is on."
	::= {els10-27pingEntry 7}

	els10-27pingOperation OBJECT-TYPE
		SYNTAX          INTEGER {on (1), off(2) }
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"Setting els10-27pingOperation to on will begin the ping request.
			Setting els10-27pingOperation to off will terminate the ping request."
	::= {els10-27pingEntry 8}

	els10-27pingMin OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The minimum round trip time for the ping requests and
			responses, in centiseconds."
	::= {els10-27pingEntry 9}

	els10-27pingMax OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The maximum round trip for the ping requests and
			responses, in centiseconds."
	::= {els10-27pingEntry 10}

	els10-27pingAvg OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The average round trip time for the ping requests and
			responses, in centiseconds."
	::= {els10-27pingEntry 11}

	els10-27pingNumTransmitted OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The number of ICMP ECHO_REQUEST messages that have
			been transmitted during this ping request."
	::= {els10-27pingEntry 12}

	els10-27pingNumReceived OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The number of ICMP ECHO_RESPONSE messages that have
			been received as a result of this ping request."
	::= {els10-27pingEntry 13}



	--  Traceroute Management 


	els10-27traceDataTimeout OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The time, in centiseconds, from the last traceroute activity (the
			response to or timeout of the last probe sent), to when the
			els10-27traceEntry information for that traceroute                      request will be
			deleted."
	::= {els10-27traceMgt 1}

	els10-27traceTable OBJECT-TYPE
		SYNTAX          SEQUENCE OF LxtraceEntry
		ACCESS          not-accessible
		STATUS          mandatory
		DESCRIPTION
			"The set of information describing the active traceroute requests
			and their results."
	::= {els10-27traceMgt 2}

	els10-27traceEntry OBJECT-TYPE
		SYNTAX          LxtraceEntry
		ACCESS          not-accessible
		STATUS          mandatory
		DESCRIPTION
			"The parameters, state, and results of a traceroute request."
		INDEX           { els10-27traceNMSAddr, els10-27traceDestAddr, els10-27traceHop,
				els10-27traceProbe}
	::= {els10-27traceTable 1}

	LxtraceEntry ::= SEQUENCE {
		els10-27traceNMSAddr
			IpAddress,
		els10-27traceDestAddr
			IpAddress,
		els10-27traceMaxTTL
			INTEGER,
		els10-27traceDataSize
			INTEGER,
		els10-27traceNumProbes
			INTEGER,
		els10-27traceWait
			TimeTicks,
		els10-27traceOperation
			INTEGER,
		els10-27traceHop
			INTEGER,
		els10-27traceHopAddr
			IpAddress,
		els10-27traceProbe
			INTEGER,
		els10-27traceState
			INTEGER,
		els10-27traceTime
			TimeTicks
	}

	els10-27traceNMSAddr OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The IP address of the NMS, used to determine which traceroute
			request to return information on."
	::= {els10-27traceEntry 1}

	els10-27traceDestAddr OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The IP address which is to be the destination of the traceroute
			request.This variable cannot be set while els10-27traceOperation is on."
	::= {els10-27traceEntry 2}

	els10-27traceMaxTTL OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The maximum time-to-live for outgoing traceroute probe
			packets. This determines the number of hops that can be in a
			traceroute. This variable cannot be set while els10-27traceOperation
			is on."
	::= {els10-27traceEntry 3}

	els10-27traceDataSize OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The size of the datagram sent with each probe. This variable
			cannot be set while els10-27traceOperation is on."
	::= {els10-27traceEntry 4}

	els10-27traceNumProbes OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The number of probes which are sent for each hop. This
			variable cannot be set while els10-27traceOperation is on."
	::= {els10-27traceEntry 5}

	els10-27traceWait OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"The time to wait in response to a probe. This variable cannot be
			set while els10-27traceOperation is on."
	::= {els10-27traceEntry 6}

	els10-27traceOperation OBJECT-TYPE
		SYNTAX          INTEGER {on (1), off(2) }
		ACCESS          read-write
		STATUS          mandatory
		DESCRIPTION
			"Setting els10-27traceOperation to on will begin the traceroute request.
			Setting els10-27traceOperation to off will terminate the traceroute
			request."
	::= {els10-27traceEntry 7}

	els10-27traceHop OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The hop count for a set of probes with a particular TTL."
	::= {els10-27traceEntry 8}

	els10-27traceHopAddr OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The IP address of the host which responded for a probe with a
			particular TTL."
	::= {els10-27traceEntry 9}

	els10-27traceProbe OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The probe instance for a particular hop."
	::= {els10-27traceEntry 10}

	els10-27traceState OBJECT-TYPE
		SYNTAX          INTEGER {
				not-started(0),
				active (1),
				time-exceeded(2),
				host-unreachable (3),
				net-unreachable (4),
				completed (5)}
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"The current state of the trace probe."
	::= {els10-27traceEntry 11}

	els10-27traceTime OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS          read-only
		STATUS          mandatory
		DESCRIPTION
			"Round trip time of a probe for a particular hop."
	::= {els10-27traceEntry 12}


-- Enterprise Specific Objects for Port Mirroring

	els10-27volmirrorMode OBJECT-TYPE
	SYNTAX INTEGER { off(0), 
		     on(1) }
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		" To turn port mirroring on or off."
	::= { els10-27volmirrorgroup 1 }

	els10-27volmirrorPort OBJECT-TYPE
	SYNTAX INTEGER 
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		" The number of the port whose data will be mirrored to a      
	  special monitor or analyzer port."
	::= { els10-27volmirrorgroup 2 }

	els10-27volmonitorPort OBJECT-TYPE
	SYNTAX INTEGER 
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		" Identifies the monitor or analyzer port to receive 
	  frames from the special mirror port."
	::= { els10-27volmirrorgroup 3 }

	els10-27volMirrorMacTable OBJECT-TYPE
	SYNTAX SEQUENCE OF Els10-27volMirrorMacEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		" A table that contains information for the mirroring
	  on MAC addresses."
	::= { els10-27volmirrorgroup 4 }

	els10-27volmirrorMacEntry OBJECT-TYPE
	SYNTAX Els10-27volMirrorMacEntry
	ACCESS not-accessible
	STATUS mandatory
	DESCRIPTION
		" Information about specific unicast MAC addresses
	  for which mirroring will act upon."
	INDEX {els10-27volmirrorIndex}
	::= { els10-27volMirrorMacTable 1 }

	Els10-27volMirrorMacEntry ::= SEQUENCE {
		els10-27volmirrorIndex
			INTEGER,
		els10-27volmirrorMac1
			OCTET STRING 
	  --      els10-27volmirrorMac2
	  --              OCTET STRING,
	  --      els10-27volmirrorMac3
	  --              OCTET STRING,
	  --      els10-27volmirrorMac4
	  --              OCTET STRING
		}
	
	els10-27volmirrorIndex   OBJECT-TYPE
		SYNTAX  INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION
		" Entry Index"
		::= {els10-27volmirrorMacEntry 1}
	
	els10-27volmirrorMac1  OBJECT-TYPE
		SYNTAX  OCTET STRING
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
		" First MAC address for mirroring."
		::= {els10-27volmirrorMacEntry 2}

	--els10-27volmirrorMac2  OBJECT-TYPE
	--        SYNTAX  OCTET STRING
	--        ACCESS  read-write
	--        STATUS  mandatory
	--        DESCRIPTION
	--        " Second MAC address for mirroring."
	--        ::= {els10-27volMirrorMacEntry 2}

	--els10-27volmirrorMac3  OBJECT-TYPE
	--        SYNTAX  OCTET STRING
	--        ACCESS  read-write
	--        STATUS  mandatory
	--        DESCRIPTION
	--        " Third MAC address for mirroring."
	--        ::= {els10-27volMirrorMacEntry 3}

	--els10-27volmirrorMac4  OBJECT-TYPE
	--        SYNTAX  OCTET STRING
	--        ACCESS  read-write
	--        STATUS  mandatory
	--        DESCRIPTION
	--        " Fourth MAC address for mirroring."
	--        ::= {els10-27volMirrorMacEntry 4}

-- The els10-27VlanBridgeConfig group manages the overall configuration
-- of the bridge's VLAN resources.
--
-- The implementation of this group is MANDATORY.

els10-27VlanVersionNumber OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "Specifies the version IEEE 802.1Q VLAN that has been implemented to."
    ::= { els10-27VlanBridgeConfig 1 }

els10-27VlanOperatingMode OBJECT-TYPE
    SYNTAX INTEGER { ieee8021d(1), ieee8021Q(2) }  
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "Selects the mode of operation.  The switch can operate as simply an 802.1d switch,
		or an 802.1d switch with IEEE VLAN capability (802.1Q).  A read of this object will return
		the current operating mode."
    DEFVAL { ieee8021d }
    ::= { els10-27VlanBridgeConfig 2 }

els10-27VlanResetDefaults OBJECT-TYPE
    SYNTAX INTEGER {
      operating(1),
      reset(2)
      }  
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "To reset the specified bridge.  The filtering database is cleared and initialized
			with the entries specified in the Permananent database, and the Bridge protocol Entity is
			initialized.  While initializing a read will return a value of reset (2).  While
			operational a read will return a value of operating (1)."
    ::= { els10-27VlanBridgeConfig 3 }
 
els10-27VlanGVRPEnable OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "If the switch is operating in 802.1Q mode, this selects whether GVRP protocol
		messages should be processed and VLANs configured accordingly for each
		port on the switch. Each octet within the value of this object specifies a set of eight
		ports, with the first octet specifying ports 1 through 8, the next octet specifying ports
		9 through 16, etc.  Within each octet, the least significant bit represents the 
		lowest numbered port, and the most significant bit represents the highest numbered port.  
		Thus, each port of the VLAN bridge is represented by single bit
		within the value of this object.  If that bit has a value of '1' then that port is
		included in the set of ports; the port is not included if its bit has a value of '0'"
    ::= { els10-27VlanBridgeConfig 4 }
 
els10-27VlanAccessList OBJECT-TYPE
    SYNTAX 	OCTET STRING (SIZE (1..8))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
      "A list of ports that should act as 'Access Ports'.  These ports will strip all tags
		on egress and also make use of a shared database that will automatically be kept by the
		firmware. Each octet within the value of this object specifies a set of eight ports, with
		the first octet specifying ports 1 through 8, the next octet specifying ports 9 through
		16, etc.  Within each octet, the least significant bit represents the lowest numbered
		port, and the most significant bit represents the highest numbered port.  Thus, each port
		of the VLAN bridge is represented by  single bit within the value of this object.  If that
		bit has a value of '1' then that port is included in the set of ports; the port is not
		included if its bit has a value of '0'"
    ::= { els10-27VlanBridgeConfig 5 }
 

els10-27VlanConfigVlan OBJECT IDENTIFIER ::= { els10-27VlanBridgeConfig 6 }
 
-- The els10-27VlanConfigVlan  manages the configuration of a specific
-- VLAN within a bridge.
-- Each VLAN will have an entry in  the  els10-27VlanConfigTable
--
-- The implementation of this group is MANDATORY.
 
els10-27VlanNumActiveEntries OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "The number of active VLAN entries for the device.  This includes both static and
			dynamic VLANs."
    ::= { els10-27VlanConfigVlan 1 }
 
els10-27VlanNumConfiguredEntries OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "The number of configured VLAN entries for the device."
    ::= { els10-27VlanConfigVlan 2 }
 
els10-27VlanMaxNumEntries OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "The maximum number of VLAN entries for the device."
    ::= { els10-27VlanConfigVlan 3 }
 
els10-27VlanConfigTable     OBJECT-TYPE
    SYNTAX SEQUENCE OF Els10-27VlanConfigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "This table allows for the creation, deletion, and modification of
       specific VLANs. The ports defined within this group will be members of the 'member
		 set' as defined in the IEEE 802.1Q specification.  Although this is configured 
       as a table, there is only a single instance. Entries should be referenced as 
		 simple variables"
    ::= { els10-27VlanConfigVlan 4 }

els10-27VlanConfigEntry    OBJECT-TYPE
    SYNTAX Els10-27VlanConfigEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Allows for configuration of specific VLAN entries. Although this is configured 
       as a table, there is only a single instance. Entries should be referenced as 
		 simple variables"
    INDEX { els10-27VlanConfigVID }
    ::= { els10-27VlanConfigTable 1 }

Els10-27VlanConfigEntry ::= SEQUENCE {
      els10-27VlanConfigIndex
	    INTEGER,
      els10-27VlanConfigVID
	    OCTET STRING,
      els10-27VlanConfigPorts
	    OCTET STRING,
      els10-27VlanConfigIP
	    IpAddress,
      els10-27VlanConfigIPMask
	    IpAddress,
      els10-27VlanConfigName
	    DisplayString,
      els10-27VlanConfigStatus
	    INTEGER,
      els10-27VlanConfigEstablish
	    INTEGER
      }  

els10-27VlanConfigIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The index into the table of vlans. The table has 32 entries (0 - 31). An index
		 value outside this range will reference the local variable.  For example if the index is
		 set to -1 and the els10-27VlanConfigVID object is read, the local variable is read, not the
		 table entry. By using an out of range value, the local variables can be read. 
		 Only the local variables are written to until els10-27VlanConfigStatus is written."
    ::= { els10-27VlanConfigEntry 1 }
 
els10-27VlanConfigVID OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8)) 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The 12 bit VLAN Identifier associated with the configured VLAN. Valid range (1..4094)"
    ::= { els10-27VlanConfigEntry 2 }
 
els10-27VlanConfigPorts OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
      " Each octet within the value of this object specifies
       a set of eight ports, with the first octet specifying
       ports 1 through 8, the next octet specifying ports 9
       through 16, etc.  Within each octet, the least significant
       bit represents the lowest numbered port, and the most
       significant bit represents the highest numbered port.
       Thus, each port of the VLAN bridge is represented by
       single bit within the value of this object.  If that bit
       has a value of '1' then that port is included in the set
       of ports; the port is not included if its bit has a value of '0'."
    ::= { els10-27VlanConfigEntry 3 }

els10-27VlanConfigIP OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The IP address to be used to access the unit on this Vlan.  This must be a
	 valid host address."
    ::= { els10-27VlanConfigEntry 4 }
 
els10-27VlanConfigIPMask OBJECT-TYPE
    SYNTAX IpAddress
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The IP subnet mask to be used with this IP address."
    ::= { els10-27VlanConfigEntry 5 }
 
els10-27VlanConfigName OBJECT-TYPE
    SYNTAX DisplayString (SIZE (1..32))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The ASCII name associated with this VLAN."
    ::= { els10-27VlanConfigEntry 6 }


els10-27VlanConfigStatus OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A set with any value of will create, modify or delete entries in 
		 the specified VLAN according to the vlaue in els10-27VlanConfigEstablish." 
    ::= { els10-27VlanConfigEntry 7 }

 
els10-27VlanConfigEstablish OBJECT-TYPE
    SYNTAX INTEGER {
      create(1),
      delete(2)
      }  
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A set of the value create(1), causes an entry to be created in
       the els10-27VlanConfigTable as specified by the instancing information
       of els10-27VlanConfigVID, els10-27VlanConfigName, and els10-27VlanConfigPorts etc,
		 when the els10-27VlanConfigStatus is written to.
       A set of delete(2) causes the specified entry to be removed from the table,
		 when the els10-27VlanConfigStatus is written to."
    ::= { els10-27VlanConfigEntry 8 }


els10-27VlanConfigEgressTable     OBJECT-TYPE
    SYNTAX SEQUENCE OF Els10-27VlanConfigEgressEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "This table allows for the specifying of the default VLAN ID for a specific port. If
		 NOT configured as an 'Access' port, then packets containing this VLAN ID will have the tag
		 stripped on egress.  This will set the PVID for each port contained within the list."
    ::= { els10-27VlanConfigVlan 5 }
 

els10-27VlanConfigEgressEntry    OBJECT-TYPE
    SYNTAX Els10-27VlanConfigEgressEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Allows for configuration of specific Egress entries. Although this is configured
       as a table, there is only a single instance. Entries should be referenced as
       simple variables"

    INDEX { els10-27VlanEgressVID }
    ::= { els10-27VlanConfigEgressTable 1 }
 
Els10-27VlanConfigEgressEntry ::= SEQUENCE {
      els10-27VlanEgressIndex
		INTEGER,
      els10-27VlanEgressVID
	    OCTET STRING,
     els10-27VlanEgressList
	    OCTET STRING,
     els10-27VlanEgressStatus
	    INTEGER
      }   

els10-27VlanEgressIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The index into the Vlan table.  A port must be a member of this Vlan prior
       to assigning this Id as the default. The table has 32 entries (0 - 31). An index
       value outside this range will reference the local variable.  
		 For example if the index is set to -1 and the els10-27VlanEgressVID object is read, 
		 the local variable is read, not the table entry.
		 By using an out of range value, the local variables can be read.
       Only the local variables are written to until els10-27VlanEgressStatus is written."
    ::= { els10-27VlanConfigEgressEntry 1 }

els10-27VlanEgressVID OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The 12 bit VLAN Identifier associated with the configured VLAN. Valid range (1..4094)"
    ::= { els10-27VlanConfigEgressEntry 2 }

els10-27VlanEgressList OBJECT-TYPE
    SYNTAX	OCTET STRING (SIZE (1..8))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
      "The set of ports to which traffic destined for
       the VLAN specified by els10-27VlanEgressVID
       on the device will have this tag stripped on
       egress.  Each octet within the value of
       this object specifies a set of eight ports, with thee
       first octet specifying ports 1 through 8, the second
       octet specifying ports 9 through 16, etc.  Within each
       octet, the least significant bit represents the lowest
       numbered port, and the most significant bit represents
       the highest numbered port.  Thus, each port of the VLAN
       bridge is represented by a single bit within the value
       of this object.  If that bit has a value of '1' then
       that port is included in the set of ports; the port is
       not included if its bit has a value of '0'."
    ::= { els10-27VlanConfigEgressEntry 3 }
 

els10-27VlanEgressStatus OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A set with any value will change all associated entries in the 
		 els10-27VlanEgressList to have the default Vlan id set to the value
       in els10-27VlanEgressVID using the els10-27VlanEgressIndex vlaue to
       index into the table."
    ::= { els10-27VlanConfigEgressEntry 4 }
 

els10-27VlanFilterGVRPTable     OBJECT-TYPE
    SYNTAX SEQUENCE OF Els10-27VlanFilterGVRPEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "This table allows for the specifying of VLAN ID's that will be resticted from being learnt
		 by the device.  If a GVRP packet is received specifying this VLAN ID, it will be ignored."
    ::= { els10-27VlanConfigVlan 6 }

els10-27VlanFilterGVRPEntry    OBJECT-TYPE
    SYNTAX Els10-27VlanFilterGVRPEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Allows for configuration of specific entries. Although this is configured
       as a table, there is only a single instance. Entries should be referenced as
       simple variables"

    INDEX { els10-27VlanFilterGVRPVID }
    ::= { els10-27VlanFilterGVRPTable 1 }
 
Els10-27VlanFilterGVRPEntry ::= SEQUENCE {
		els10-27VlanFilterGVRPIndex
		INTEGER,
      els10-27VlanFilterGVRPVID
	 	OCTET STRING,
      els10-27VlanFilterGVRPList
	 	OCTET STRING,
		els10-27VlanFilterGVRPStatus
	 	INTEGER,
		els10-27VlanFilterGVRPEstablishVID
	 	INTEGER	
		}
 
els10-27VlanFilterGVRPIndex OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The index into the Vlan Filter table.  A maximum of 32
		 Vlan ID can be restricted from being learnt via GVRP. The table has 
		 32 entries (0 - 31). An index value outside this range will 
		 reference the local variable.
       For example if the index is set to -1 and the els10-27VlanFilterGVRPVID 
		 object is read, the local variable is read, not the table entry.
		 By using an out of range value, the local variables can be read.
       Only the local variables are written to until els10-27VlanFilterGVRPStatus is written."
    ::= { els10-27VlanFilterGVRPEntry 1 }
 
els10-27VlanFilterGVRPVID OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The 12 bit VLAN Identifier associated with the configured VLAN. Valid range (1..4094)"
    ::= { els10-27VlanFilterGVRPEntry 2 }
 
els10-27VlanFilterGVRPList OBJECT-TYPE
    SYNTAX 	OCTET STRING (SIZE (1..8))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
      "The set of ports that will be restricted from leaning
		 of a  VLAN ID from a GVRP message.  The VLAN ID
       is specified by els10-27VlanFilterGVRPVID.
       Each octet within the value of
       this object specifies a set of eight ports, with thee
       first octet specifying ports 1 through 8, the second
       octet specifying ports 9 through 16, etc.  Within each
       octet, the least significant bit represents the lowest
       numbered port, and the most significant bit represents
       the highest numbered port.  Thus, each port of the VLAN
       bridge is represented by a single bit within the value
       of this object.  If that bit has a value of '1' then
       that port is included in the set of ports; the port is
       not included if its bit has a value of '0'."
    ::= { els10-27VlanFilterGVRPEntry 3 }
 

els10-27VlanFilterGVRPStatus OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A set with any value enables all associated entries
      in els10-27VlanFilterGVRPVID table for the specified VLAN."
    ::= { els10-27VlanFilterGVRPEntry 4 }
 

els10-27VlanFilterGVRPEstablishVID OBJECT-TYPE
    SYNTAX INTEGER {
      create(1),
      delete(2)
      }  
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A set of the value create(1), will cause an entry to be created in
       the els10-27VlanFilterGVRPTable using els10-27VlanFilterGVRPIndex,
       els10-27VlanFilterGVRpVID, and els10-27VlanFilterGVRPList once a write is
		 done to els10-27VlanFilterGVRPStatus.
       A set of delete(2) causes the specified entry to be removed from the table
		 once a write is done to els10-27VlanFilterGVRPStatus."
    ::= { els10-27VlanFilterGVRPEntry 5 }
 

els10-27VlanStaticTable     OBJECT-TYPE
    SYNTAX SEQUENCE OF Els10-27VlanStaticEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Allows for configuration of specific VLAN/MAC Address entries and to specify the
		 port to which traffic destined for this address pair should be forwarded.  These entries
		 will not be aged out of the forwarding data base, but they will not be saved across
		 a reboot."
    ::= {  els10-27VlanConfigVlan 7 }
 

els10-27VlanStaticEntry    OBJECT-TYPE
    SYNTAX Els10-27VlanStaticEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Allows for configuration of specific entries. Although this is configured
       as a table, there is only a single instance. Entries should be referenced as
       simple variables"

    INDEX { els10-27VlanStaticVID }
    ::= { els10-27VlanStaticTable 1 }
 
Els10-27VlanStaticEntry ::= SEQUENCE {
      els10-27VlanStaticVID
	    OCTET STRING,
     els10-27VlanStaticMAC
	    PhysAddress,
     els10-27VlanStaticPort
	    INTEGER,
     els10-27VlanStaticEstablish
	    INTEGER
      }  

els10-27VlanStaticVID OBJECT-TYPE
    SYNTAX OCTET STRING (SIZE (1..8))
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "The 12 bit VLAN Identifier associated with the configured VLAN. Valid range (1..4094)"
    ::= { els10-27VlanStaticEntry 1 }
 
els10-27VlanStaticMAC OBJECT-TYPE
    SYNTAX  PhysAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
      "The media dependent physical address."
    ::= { els10-27VlanStaticEntry 2 }
 
els10-27VlanStaticPort OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "An integer designating the port number to associate this address to."
    ::= { els10-27VlanStaticEntry 3 }
 

els10-27VlanStaticEstablish OBJECT-TYPE
    SYNTAX INTEGER {
      create(1),
      delete(2)
      }  
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
   "A set of the value create(1), causes an entry to be created  as specified by the instancing
    information of els10-27VlanSaticVID, els10-27VlanStaticMAC, and els10-27VlanStaticPort. 
	 A set of delete(2) causes the specified entry to be removed from the table."
    ::= { els10-27VlanStaticEntry 4 }
 
-- the IP Multicast group

	els10-27IPMulticastStatus       OBJECT-TYPE
		SYNTAX  INTEGER {enabled (1),
		     disabled (0)}
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
		" Parameter to enable or disable IP multicast filtering 
      on the device. When enabled, the device will examine IP
      Multicast data packets and dynamically set up filter 
      ports to prevent flooding.
      The default is disabled."
		::= {els10-27volipmgroup 1}

	els10-27ipmInterfaceRtr         OBJECT-TYPE
		SYNTAX  INTEGER 
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
    "Parameter to enable or disable the inclusion of this
     interface in all Multicast filters. When enabled, all
     IP Multicast packets for all group filters will be
     transmitted over this interface. Value is a bit mask."
		::= {els10-27volipmgroup 2}


-- the IGMP group
	els10-27igmpStatus      OBJECT-TYPE 
		SYNTAX  INTEGER {enabled (0),
		     disabled (1) }
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
    "Parameter to enable or disable IGMP snooping on
     the device. When enabled, the device will examine IGMP
     packets and set  up filters for IGMP ports.
     The default is enabled."
		::= {els10-27voligmpgroup 1}

	els10-27igmpQueryStatus OBJECT-TYPE
		SYNTAX  INTEGER {enabled (1),
		     disabled (0) }
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
    "Parameter to enable or disable the device to act as a
     Querier. If enabled, the device will send out a Query
     as a Proxy to solicit reports. The device will not 
     become an IGMP router.
     The default is disabled."
		::= {els10-27voligmpgroup 2}

	els10-27igmpQueryCount  OBJECT-TYPE
		SYNTAX  INTEGER 
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
    "Maximum number of queries that have not been heard on the
     system before the system starts taking action to solicit
     reports (default is 5)."
		::= {els10-27voligmpgroup 3}

	els10-27igmpPortDelay   OBJECT-TYPE
		SYNTAX  INTEGER 
		ACCESS  read-write
		STATUS  mandatory
		DESCRIPTION
    "Timeout value (mins) between IGMP Reports or IGMP Queries
     received on a port before the system times out the entry
     from the Multicast Address Filter (default is 5 minutes)."
		::= {els10-27voligmpgroup 4}

-- The IGMP Cache Table

	els10-27igmpCacheTable  OBJECT-TYPE
		SYNTAX  SEQUENCE OF Els10-27igmpCacheEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION
    "The (conceptual) table listing the IP multicast groups
     for which there are members on a particular interface."
		::={els10-27voligmpgroup 5}

	els10-27igmpCacheEntry  OBJECT-TYPE
		SYNTAX  Els10-27igmpCacheEntry
		ACCESS  not-accessible
		STATUS  mandatory
		DESCRIPTION
	"An entry (conceptual row) in the els10-27igmpCacheTable."
	INDEX   {els10-27igmpCacheAddress,els10-27igmpCacheIfIndex}
		::={els10-27igmpCacheTable 1}

	Els10-27igmpCacheEntry ::= SEQUENCE {
		els10-27igmpCacheAddress
		IpAddress,
		els10-27igmpCacheIfIndex
		INTEGER,
		els10-27igmpCacheExpiryTime
		TimeTicks
		}

	els10-27igmpCacheAddress        OBJECT-TYPE
		SYNTAX          IpAddress
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION
	"The IP multicast group address for which this entry
	contains information."
		::={els10-27igmpCacheEntry 1}

	els10-27igmpCacheIfIndex        OBJECT-TYPE
		SYNTAX          INTEGER
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION
	"The interface for which this entry contains infor-
	mation for an IP multicast group address."
		::={els10-27igmpCacheEntry 2}

	els10-27igmpCacheExpiryTime     OBJECT-TYPE
		SYNTAX          TimeTicks
		ACCESS  read-only
		STATUS  mandatory
		DESCRIPTION
	"The minimum amount of time remaining before this
	entry will be aged out."
		::={els10-27igmpCacheEntry 3}
  
 
--  The els10-27FlowControl MIB is used to manage Volcano devices.
--  This managed object will allow for control and statistics
--  on half duplex flow control (back pressure) ports and IEEE 802.3x full
--  duplex flow control ports.


els10-27FlowControlBackPressure OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "Control back pressure on a system wide basis.
	On (1),
	Off (2)"
    ::= { els10-27FlowControlCtl 1 }
 
els10-27FlowControlThresholdValue OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      " A value specified as a percent of the available buffers.
	 When fewer than the percent of the avaialable buffers
	 is detected, flow control will be initiated.  Flow control
	 will cease when the free buffer count meets or exceeds
	 this percent."
    ::= { els10-27FlowControlCtl 2 }
 
els10-27FlowControlPauseInteval OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      "A value between 10 and 65535.  Each pause interval is  equal
	to '5.12 microseconds'.   A value of 10 will equal '51.2
	microseconds'."
    ::= { els10-27FlowControlCtl 3 }
 
els10-27FlowControlTable OBJECT-TYPE
    SYNTAX SEQUENCE OF Els10-27FlowControlEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
      "Provides a list of control objects over flow control parameters."
    ::= { els10-27FlowControlCtl 4 }
 
els10-27FlowControlEntry OBJECT-TYPE
     SYNTAX Els10-27FlowControlEntry
     ACCESS not-accessible
     STATUS mandatory
     DESCRIPTION
       "Defines a particular entry containing objects pertaining to
	definition and control over flow control ports."
     INDEX { els10-27FlowControlInterface}
     ::= { els10-27FlowControlTable 1 }
 
Els10-27FlowControlEntry ::= SEQUENCE {
      els10-27FlowControlInterface
	     INTEGER,
      els10-27FlowControlEnable
	     INTEGER,
      els10-27FlowControlRxPauseFrames
	     INTEGER,
      els10-27FlowControlTxPauseFrames
	     INTEGER
 }


els10-27FlowControlInterface OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      " The MIB2 interface for which this flow control information pertains"
    ::= { els10-27FlowControlEntry 1 }

els10-27FlowControlEnable OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
      " Control 802.3x flow control on a per interface basis.
	On (1),
	Off (2)"
    ::= { els10-27FlowControlEntry 2 }
 
els10-27FlowControlRxPauseFrames   OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "The number of pause frames received on this interface."
    ::= { els10-27FlowControlEntry 3 }
 
els10-27FlowControlTxPauseFrames OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
      "The number of pause frames transmitted on this interface."
    ::= { els10-27FlowControlEntry 4 }


-- Enterprise Specific Traps for the ELS10-27

els10-27WriteStatusTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27swdisWriteStatus,
	els10-27swdisDesc       
    }
    DESCRIPTION
	"Sent when a bank of Flash EPROM has been erased.  If 
	 els10-27swdisWriteStatus indicates success, then the unit is ready 
	 to be downloaded with the new software."  
    ::= 2

els10-27PortFunctionsTrap TRAP-TYPE 
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27ifFunction
    }
    DESCRIPTION
	"Sent whenever the current functional state (active 
	 protocols) of the port has changed."
    ::= 3

els10-27RxQueuesTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27ifRxQueues      
    }
    DESCRIPTION
	"Sent whenever the number of times that the port's receiver 
	 has stopped receiving packets due to buffer space shortages 
	 has exceeded the port's limit." 
    ::= 4

els10-27RxStormFlagTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity 
    }
    DESCRIPTION
	"Sent whenever broadcast/multicast storm protection has been invoked 
	 for the port."
    ::= 5

els10-27TxCongestsTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27adminNAMReceiveCongests
    }
    DESCRIPTION
	"Sent whenever packets destined for the unit itself were 
	 discarded due to lack of buffer space."
    ::= 6

els10-27DebugStringIdTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27debugStringID,
	els10-27debugString
    }
    DESCRIPTION
	"Sent whenever the unit has a debug text string to be 
	 displayed. The text strings are sent in a stream-like 
	 fashion."  
    ::= 8

els10-27LpbkOperationTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	els10-27lpbkOperation,  
	els10-27lpbkErrorNoReceives,    
	els10-27lpbkErrorBadReceives    
    }
    DESCRIPTION
	"Send whenever the unit has finished a loop back test, or 
	 a loop back error has been detected."  
    ::= 9

els10-27TrunkStateTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	els10-27trunkState
    }
    DESCRIPTION
	"A trunking state change transition has occurred. The possible 
	 transitions are:
	    CLOSED-ONEWAY
	    ONEWAY-PERTURBED
	    PERTURBED-JOINED
	    JOINED-HELDDOWN
	    CLOSED-HELDDOWN
	    ONEWAY-HELDDOWN
	    PERTURBED-HELDDOWN"
    ::= 10

els10-27TrunkBridgeAddrTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	els10-27trunkRemoteBridgeAddr
    }
    DESCRIPTION
	"The associated trunking MAC address of the bridge ID of the remote 
	 bridge has changed."
    ::= 11

els10-27TrunkIPAddrTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	els10-27trunkRemoteIp
    }
    DESCRIPTION
	"The associated trunking IP address of the remote bridge has changed."
    ::= 12

els10-27TrunkErrorTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	els10-27trunkLastError
    }
    DESCRIPTION
	"An error has occurred in trunking."
    ::= 13

els10-27TrunkLinkOrdinalTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	els10-27trunkLinkOrdinal
    }
    DESCRIPTION
	"The port's index in the trunking group has changed."
    ::= 14

els10-27TrunkLinkCountTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
    els10-27trapSeverity,
    els10-27trunkLinkCount
    }
    DESCRIPTION
	"The number of ports in the trunking group has changed."
    ::= 15

els10-27DiagUnitBootedTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   { 
	els10-27trapSeverity,
	els10-27adminFatalErr
    }
    DESCRIPTION
	"The unit has booted. els10-27adminFatalErr contains information about 
	 why the unit rebooted."
    ::= 16

els10-27StorageFailureTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity
    }
    DESCRIPTION
	"Sent if the unit's Configuration EEPROM has failed. The unit
	 will not be able to reboot, and must be returned to the 
	 factory."
::= 17

els10-27PortCongestedTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	ifOutDiscards
    }
    DESCRIPTION
	"Sent whenever outbound congestion control has been invoked 
	 for the port."
    ::= 18

els10-27TopChangeBegunTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity
    }
    DESCRIPTION
	"The spanning tree topology has begun to change."
    ::= 19

els10-27TopChangeEndTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity
    }
    DESCRIPTION
	"The spanning tree topology has stopped changing."
::= 20

els10-27IfErrorsTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {
	els10-27trapSeverity,
	ifInErrors,
	ifOutErrors
    }
    DESCRIPTION
	"Sent whenever the number of hardware errors in received and 
	 transmitted packets has exceeded the port's limit." 
    ::= 21

els10-27StRootIDTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpDesignatedRoot
    } 
    DESCRIPTION
	"The spanning tree root bridge ID for the unit has changed."
    ::= 22

els10-27StRootCostTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpRootCost
    }
    DESCRIPTION
	"The unit's spanning tree cost to the root bridge has changed."
    ::= 23

els10-27StRootPortTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpRootPort
    } 
    DESCRIPTION
	"The unit's spanning tree root port has changed."
    ::= 24

els10-27StMaxAgeTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpMaxAge
    }
    DESCRIPTION
	"The unit's spanning tree maximum age has changed."
    ::= 25

els10-27StHelloTimeTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpHelloTime
    }
    DESCRIPTION
	"The unit's spanning tree hello time has changed."
    ::= 26

els10-27StForwardDelayTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpForwardDelay
    }
    DESCRIPTION
	"The unit's spanning tree forward delay time has changed."
    ::= 27

els10-27StDesigRootTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpPortDesignatedRoot
    }
    DESCRIPTION
	"The Root Bridge ID in received Spanning Tree Configuration BPDUs
	 from the port has changed."
    ::= 28

els10-27StPortDesigBridgeTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpPortDesignatedBridge
    }
    DESCRIPTION 
	"The bridge ID of the spanning tree designated bridge of the LAN/WAN
	 to which the port is attached has changed."
    ::= 29

els10-27StPortDesigCostTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpPortDesignatedCost
    }
    DESCRIPTION
	"The cost to the spanning tree root bridge from the designated port of 
	 the LAN/WAN to which the port is attached has changed."
    ::= 30

els10-27StPortDesigPortTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpPortDesignatedPort
    }
    DESCRIPTION
	"The port ID of the spanning tree designated port of the LAN/WAN
	 to which the port is attached has changed."
    ::= 31

els10-27StPortStateTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
	els10-27trapSeverity,
	dot1dStpPortState
    }
    DESCRIPTION
	"The spanning tree state of the port has changed."
    ::= 32

els10-27hwDiagTrap TRAP-TYPE
    ENTERPRISE  sysObjectID
    VARIABLES   {       
	els10-27trapSeverity,
	els10-27hwDiagCode      
    }
    DESCRIPTION
	"Sent whenever the unit's diagnostics have indicated an error."
    ::= 100
 
els10-27InvalidConfigurationFileTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
   els10-27trapSeverity,
   dot1dStpPortDesignatedPort
    }
    DESCRIPTION
   "Diagnostics has detected corrupted configuration data. 
	 Default parameter values have been restored."
    ::= 34
 
els10-27StInvalidFlashCodeImageTrap TRAP-TYPE
    ENTERPRISE sysObjectID
    VARIABLES {
   els10-27trapSeverity,
   dot1dStpPortState
    }
    DESCRIPTION
   "An invalid code image was detected in flash memory. 
	 An attempt will be made to obtain a valid image."
    ::= 35
 


	END