REPEATER-MIB DEFINITIONS ::= BEGIN

--  ctron-rrev4-mib.txt
--  Revision: 1.30
--  Date: August 14, 1992

--  Cabletron Systems, Inc.
--  35 Industrial Way, P.O. Box 5005
--  Rochester, NH 03867-0505
--  (603) 332-9400
--  support@ctron.com

--  This module provides authoritative definitions for Cabletron's
--  enterprise-specific repeater MIB.
--
--  This module will be extended, as required.
--

--  Cabletron Systems reserves the right to make changes in 
--  specification and other information contained in this document 
--  without prior notice.  The reader should consult Cabletron Systems
--  to determine whether any such changes have been made.
--
--  In no event shall Cabletron Systems be liable for any incidental, 
--  indirect, special, or consequential damages whatsoever (including 
--  but not limited to lost profits) arising out of or related to this
--  document or the information contained in it, even if Cabletron
--  Systems has been advised of, known, or should have known, the 
--  possibility of such damages.
--
--  Cabletron grants vendors, end-users, and other interested parties
--  a non-exclusive license to use this Specification in connection
--  with the management of Cabletron products.

--  Copyright August 92 Cabletron Systems

IMPORTS
	enterprises, NetworkAddress, Counter
			FROM  RFC1155-SMI
	OBJECT-TYPE	FROM RFC-1212
	DisplayString FROM SNMPv2-TC;


-- Formal definitions for Repeater

cabletron	OBJECT IDENTIFIER ::= { enterprises 52 }

mibs		OBJECT IDENTIFIER ::= { cabletron 4 }

ctron		OBJECT IDENTIFIER ::= { mibs 1 }

ctphysical	OBJECT IDENTIFIER ::= { ctron 1 }


-- Repeater Node

-- The following branch in the repeater MIB tree pertains to the repeater
-- as a whole

repeater	OBJECT IDENTIFIER ::= {ctphysical 1 }

repeaterRev4	OBJECT IDENTIFIER ::= { repeater 4 }

-- 
-- Repeater Management Object Definitions

rptr		OBJECT IDENTIFIER ::= { repeaterRev4 1 }

rptrMgmt	OBJECT IDENTIFIER ::= { rptr 1 }

-- This section defines the management objects under the Repeater node.
-- The implementation of this group of objects is mandatory.

  
rptrMgmtName     OBJECT-TYPE
SYNTAX      DisplayString (SIZE(20))
ACCESS      read-write
STATUS      mandatory
DESCRIPTION
    "The ASCII name assigned to this network."
 ::= {rptrMgmt 1}

rptrMgmtPortCount        OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
    "Total number of ports residing on this lan segment."
 ::= {rptrMgmt 2}

rptrMgmtPortsEnable      OBJECT-TYPE
SYNTAX      INTEGER {
		noEnable(1),
		enable(2)
		}
ACCESS      read-write
STATUS      mandatory
DESCRIPTION
	"Setting this object to Enable will cause all the ports
	residing in this network segment to be enabled.  Setting
	this object to noEnable will have no effect.  When read
	this object will always return noEnable."
 ::= {rptrMgmt 3}

rptrMgmtPortsOn      OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get the total number of ON ports in this network."
 ::= {rptrMgmt 4}
																				  
rptrMgmtPortsOper        OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get the number of operational ports in this network."
 ::= {rptrMgmt 5}
-- 

rptrMgmtBoardMap     OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get a map of the chassis slots occupied by the boards in
	this network."
 ::= {rptrMgmt 6}
	  
rptrMgmtInterfaceNum	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get the MIBII interface number of this network.  A return of zero will 
	mean this network is not associated with a MIBII interface."
 ::= {rptrMgmt 7}


-- Repeater Packet Statistical Object Definitions

rptrStats		OBJECT IDENTIFIER ::= { rptr 2 }

-- This section defines the packet statistical objects under the
-- Repeater node.
-- The implementation of this group of objects is mandatory.

rptrPktStats		OBJECT IDENTIFIER ::= { rptrStats 1 }


rptrPktStatsPackets	OBJECT-TYPE
SYNTAX	   	Counter
ACCESS		read-only
STATUS	   	mandatory
DESCRIPTION
	"Get this repeater's total received packets."
 ::= {rptrPktStats 1}

rptrPktStatsBytes	OBJECT-TYPE
SYNTAX	   	Counter
ACCESS		read-only
STATUS	   	mandatory
DESCRIPTION
	"Get this repeater's total received bytes."
 ::= {rptrPktStats 2}

rptrPktStatsColls	OBJECT-TYPE
SYNTAX	   	Counter
ACCESS		read-only
STATUS	   	mandatory
DESCRIPTION
	"Get this repeater's total collisions."
 ::= {rptrPktStats 3}
-- 

rptrPktStatsErrors	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total errors."
 ::= {rptrPktStats 4}

rptrPktStatsAlign	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total frame alignment errors."
 ::= {rptrPktStats 5}

rptrPktStatsCRC		OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total CRC errors."
 ::= {rptrPktStats 6}

rptrPktStatsOOW		OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total out-of-window collisions."
 ::= {rptrPktStats 7}

rptrPktStatsNoRsc	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"This counter is the number of packets on this network that the
	hardware has processed that the management has either not seen yet,
	in the case of an active network, or has missed missed all
	together, in the case of a once active network."

 ::= {rptrPktStats 8}

-- Repeater Protocol Statistical Object Definitions
-- This section defines the protocol statistical objects under the 
-- Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrProtocols		OBJECT IDENTIFIER ::= { rptrStats 2 }

rptrProtocolsOSI	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received OSI packets."
 ::= {rptrProtocols 1}
-- 

rptrProtocolsNovell	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received Novell packets."
 ::= {rptrProtocols 2}

rptrProtocolsBanyan	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received Banyan packets."
 ::= {rptrProtocols 3}

rptrProtocolsDECNet	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received DECNet packets."
 ::= {rptrProtocols 4}

rptrProtocolsXNS	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received XNS  packets."
 ::= {rptrProtocols 5}

rptrProtocolsIP	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received TCP/IP packets."
 ::= {rptrProtocols 6}

rptrProtocolsCtron	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received CTRON Management packets."
 ::= {rptrProtocols 7}

rptrProtocolsAppletalk	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received Appletalk packets."
 ::= {rptrProtocols 8}
-- 

rptrProtocolsOther	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received unknown protocol packets."
 ::= {rptrProtocols 9}


-- Repeater Frame Size Statistical Object Definitions

rptrFrameSizes		OBJECT IDENTIFIER ::= { rptrStats 3 }

-- This section defines the frame size statistical objects under the 
-- Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrFrameSzRunt		OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size less than
	64 bytes."
 ::= {rptrFrameSizes 1}

rptrFrameSz64To127	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size between
	64 and 127 bytes."
 ::= {rptrFrameSizes 2}

rptrFrameSz128To255	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size between
	128 and 255 bytes."
 ::= {rptrFrameSizes 3}

rptrFrameSz256To511	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size between
	256 and 511 bytes."
 ::= {rptrFrameSizes 4}
-- 

rptrFrameSz512To1023	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size between
	512 and 1023 bytes."
 ::= {rptrFrameSizes 5}

rptrFrameSz1024To1518	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size between
	1024 and 1518 bytes."
 ::= {rptrFrameSizes 6}


rptrFrameSzGiant	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this repeater's total received packets of size greater
	than 1518 bytes."
 ::= {rptrFrameSizes 7}


-- Repeater Alarm Object Definitions

rptrAlarms		OBJECT IDENTIFIER ::= { rptr 3 }

-- This section defines the alarm objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrAlarmsTrafEnable	OBJECT-TYPE
SYNTAX		INTEGER {
      		disable(1),
      		enable(2)
      		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether traffic alarms are enabled/disabled.
	Set allows for enabling/disabling of traffic alarms."
 ::= {rptrAlarms 1}

rptrAlarmsTrafThreshold	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set packet threshold within the timebase that will cause
	an alarm."
 ::= {rptrAlarms 2}
-- 

rptrAlarmsCollEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether collision alarms are enabled/disabled.
	Set allows for enabling/disabling of collision alarms."
 ::= {rptrAlarms 3}

rptrAlarmsCollThreshold	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the number of collisions per good packet within
	the timebase that will cause an alarm."
 ::= {rptrAlarms 4}

rptrAlarmsErrEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether error alarms are enabled/disabled.
	Set allows for enabling/disabling of error alarms."
 ::= {rptrAlarms 5}

rptrAlarmsErrThreshold		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the percentage of errors per good packet within
	the timebase that will cause an alarm."
 ::= {rptrAlarms 6}

rptrAlarmsErrSource		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set a bit encoded map of which errors to include in the
	error sum, as follows:

	CRC_errors 	-	Bit 0 - Least Significant Bit
	runts 		-	Bit 1
	OOW_colls 	-	Bit 2
	align_errs 	-	Bit 3
	No_resource -	Bit 4
	Giants 		-	Bit 5"
 ::= {rptrAlarms 7}
-- 

rptrAlarmsAlarmTimebase   OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-write
STATUS      mandatory
DESCRIPTION
	"Get/Set alarm timebase."
 ::= {rptrAlarms 8}


-- Repeater Redundancy Object Definitions

-- Repeater redundancy as a whole is an optional implementation.
-- However, if any group concerning redundancy is implemented, all
-- of the groups involved in the redundancy implementation must be
-- provided.

rptrRedundancy		OBJECT IDENTIFIER ::= { rptr 4 }

-- This section defines the redundancy objects under the Repeater node.

rptrRedund		OBJECT IDENTIFIER ::= { rptrRedundancy 1 }

rptrRedundReset		OBJECT-TYPE
SYNTAX	INTEGER {
	noReset(1),
	reset(2)
	}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"If this object is set to Reset it will cause a reset
	 of the redundancy object to occur.  Setting this
	 object to NoReset will do nothing. This object will always 
	 be read as NoReset."
 ::= {rptrRedund 1}

rptrRedundPollInterval	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the number of seconds between polls for redundancy."
 ::= {rptrRedund 2}

rptrRedundTestTOD	OBJECT-TYPE
SYNTAX		DisplayString (SIZE(8))
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the time of day at which the redundant circuits will
	be tested.  The format of the time string is hh:mm:ss."
 ::= {rptrRedund 3}
-- 

rptrRedundPerformTest	OBJECT-TYPE
SYNTAX	INTEGER {
	noTest(1),
	test(2)
	}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"If this object is set to Test it will cause a test of the
	redundant circuits to be performed.  Setting this object to
	NoTest will have no effect.  When read this object will always
	return NoTest."
 ::= {rptrRedund 4}

rptrRedundMaxCrcts		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the maximum number of circuits which may exist on this
	network."
 ::= {rptrRedund 5}

-- Repeater Redundant Circuit Object Definitions

-- This section defines a table of redundant circuit objects under the Repeater node.

rptrRedundCrctTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrRedundCrctEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"A list of redundant circuit objects for this repeater."
 ::= { rptrRedundancy 2 }

rptrRedundCrctEntry	OBJECT-TYPE
SYNTAX		RptrRedundCrctEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"A list of objects for a particular redundant circuit."
INDEX		{ rptrRedundCrctId }
 ::= { rptrRedundCrctTable 1 }
-- 

RptrRedundCrctEntry ::=
  SEQUENCE {
	rptrRedundCrctId
		INTEGER,
	rptrRedundCrctName
		OCTET STRING,
	rptrRedundCrctRetrys
		INTEGER,
	rptrRedundCrctNumBPs
		INTEGER,
	rptrRedundCrctNumAddr
		INTEGER,
	rptrRedundCrctAddAddr
		NetworkAddress,
	rptrRedundCrctDelAddr
		NetworkAddress,
	rptrRedundCrctEnable
		INTEGER,
	rptrRedundCrctReset
		INTEGER
  }	

rptrRedundCrctId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the index for a member circuit in the table of
	redundant circuits."
 ::= {rptrRedundCrctEntry 1}

rptrRedundCrctName	OBJECT-TYPE
SYNTAX		OCTET STRING
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the name of the indicated circuit."
 ::= {rptrRedundCrctEntry 2}

rptrRedundCrctRetrys	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the the number of unanswered polls allowed for
	the circuit."
 ::= {rptrRedundCrctEntry 3}

rptrRedundCrctNumBPs	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get the number of board/port combinations associated with
	the circuit."
 ::= {rptrRedundCrctEntry 4}
-- 

rptrRedundCrctNumAddr	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get the number of IP Addresses associated with the circuit."
 ::= {rptrRedundCrctEntry 5}

rptrRedundCrctAddAddr	OBJECT-TYPE
SYNTAX		NetworkAddress
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Add an IP Address to the polling list for the indicated circuit."
 ::= {rptrRedundCrctEntry 6}

rptrRedundCrctDelAddr	OBJECT-TYPE
SYNTAX		NetworkAddress
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Delete an IP Address from the polling list of the indicated
	circuit."
 ::= {rptrRedundCrctEntry 7}

rptrRedundCrctEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"If this object is set to Enable, the circuit is enabled.  If
	this object is set to Disable,  the circuit is disbabled.  When
	read, this object returns the state of the object based on the
	last request made."
 ::= {rptrRedundCrctEntry 8}


rptrRedundCrctReset	OBJECT-TYPE
SYNTAX		INTEGER {
		noReset(1),
		reset(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"If this object is set to Reset, the circuit is reset.  All
	of the circuit's associated boards and ports are returned to
	NOT_USED, any associated IP Addresses are purged from the
	circuit's address list, the name is cleared, and the retry
	count is reset to a default value.  Setting this object to
	NoReset has no effect.  When read, NoReset is always returned."
 ::= {rptrRedundCrctEntry 9}


-- 
-- Repeater Redundant Port Object Definitions

-- This section defines a table of redundant port objects under the Repeater node.

rptrRedundPortTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrRedundPortEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"A list of redundant port objects for this repeater."
 ::= { rptrRedundancy 3 }

rptrRedundPortEntry	OBJECT-TYPE
SYNTAX		RptrRedundPortEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"A redundant port entry containing objects pertaining to
		 a particular redundant port."
INDEX		{ rptrRedundPortId, rptrRedundPortCrctId }
 ::= { rptrRedundPortTable 1 }

RptrRedundPortEntry ::=
  SEQUENCE {
	rptrRedundPortId
		INTEGER,
	rptrRedundPortCrctId
		INTEGER,
	rptrRedundPortNum
		INTEGER,
	rptrRedundPortBoardNum
		INTEGER,
	rptrRedundPortType
		INTEGER
  }

rptrRedundPortId		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"A unique value identifying an element in a sequence of member
	ports which belong to a circuit in the table of redundant
	circuits.  This value is not a port number; rather it is a value
	which goes from 1 to the maximum number of ports which may be
	included in a redundant circuit."
 ::= {rptrRedundPortEntry 1}

rptrRedundPortCrctId		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"A unique value identifying a member circuit in the table of
	redundant circuits.  This value is similar to rptrRedundCrctId."
 ::= {rptrRedundPortEntry 2}
-- 

rptrRedundPortNum		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the port number of a member port belonging to a redundant
	circuit."
 ::= {rptrRedundPortEntry 3}

rptrRedundPortBoardNum		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the board number of a member port belonging to a
	redundant circuit."
 ::= {rptrRedundPortEntry 4}

rptrRedundPortType		OBJECT-TYPE
SYNTAX		INTEGER {
		notUsed(1),
		primary(2),
		backup(3)
		}
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return the state of a port associated with the indicated circuit."
 ::= {rptrRedundPortEntry 5}


-- Repeater Redundant IP Address Object Definitions

-- This section defines a table of redundant IP Address objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrRedundAddrTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrRedundAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrRedundancy 4 }

rptrRedundAddrEntry	OBJECT-TYPE
SYNTAX		RptrRedundAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrRedundAddrId, rptrRedundAddrCrctId }
 ::= { rptrRedundAddrTable 1 }
-- 

RptrRedundAddrEntry ::=
  SEQUENCE {
	rptrRedundAddrId
		INTEGER,
	rptrRedundAddrCrctId
		INTEGER,
	rptrRedundAddrIPAddr
		NetworkAddress
  }

rptrRedundAddrId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"A unique value identifying an element in a sequence of member
	IP Addresses which belong to a circuit in the table of redundant
	circuits.  This value goes from 1 to the maximum number of IP
	Addresses which may be included in a redundant circuit."
 ::= {rptrRedundAddrEntry 1}


rptrRedundAddrCrctId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"A unique value identifying a member circuit in the table of
	redundant circuits.  This value is similar to rptrRedundCrctId."
 ::= {rptrRedundAddrEntry 2}

rptrRedundAddrIPAddr	OBJECT-TYPE
SYNTAX		NetworkAddress
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an IP Address associated with the indicated circuit."

 ::= {rptrRedundAddrEntry 3}


-- Repeater Source Address List Object Definitions
-- Repeater Source Addressing List as a whole is an optional implementation.
-- However, if any group of source addressing objects is implemented, the
-- entire set of source addressing object groups must be implemented.

rptrSourceAddress	OBJECT IDENTIFIER ::= { rptr 5 }

-- This section defines a table of Source Address List objects under the Repeater node.

rptrSrcAddrListTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrSrcAddrListEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrSourceAddress 1 }
-- 

rptrSrcAddrListEntry	OBJECT-TYPE
SYNTAX		RptrSrcAddrListEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrSrcAddrListId }
 ::= { rptrSrcAddrListTable 1 }

RptrSrcAddrListEntry ::=
  SEQUENCE {
	rptrSrcAddrListId
		INTEGER,
	rptrSrcAddrAddressList
		OCTET STRING
  }

rptrSrcAddrListId		OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index into a table of source address seen by this
	repeater."
 ::= {rptrSrcAddrListEntry 1}

rptrSrcAddrAddressList		OBJECT-TYPE
SYNTAX		OCTET STRING (SIZE(6))
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns a source address seen by this repeater."
 ::= {rptrSrcAddrListEntry 2}


-- Repeater Source Address Source Object Definitions

-- This section defines a table of Source Address Source objects under the Repeater node.

rptrSrcAddrSrcTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrSrcAddrSrcTableEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrSourceAddress 2 }

rptrSrcAddrSrcTableEntry	OBJECT-TYPE
SYNTAX		RptrSrcAddrSrcTableEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrSrcAddrSrcTableEntryId }
 ::= { rptrSrcAddrSrcTable 1 }
-- 

RptrSrcAddrSrcTableEntry ::=
  SEQUENCE {
	rptrSrcAddrSrcTableEntryId
		OCTET STRING,
	rptrSrcAddrSrcTableEntryPort
		INTEGER,
	rptrSrcAddrSrcTableEntryPortGroup
		INTEGER
  }

rptrSrcAddrSrcTableEntryId	OBJECT-TYPE
SYNTAX		OCTET STRING (SIZE(6))
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the source address to which this table's information
	pertains."
 ::= {rptrSrcAddrSrcTableEntry 1}

rptrSrcAddrSrcTableEntryPort	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the port# of the port that sourced the source address."
 ::= {rptrSrcAddrSrcTableEntry 2}

rptrSrcAddrSrcTableEntryPortGroup	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the port group# of the port that sourced the source address."
 ::= {rptrSrcAddrSrcTableEntry 3}


-- Repeater Source Address Source Object Definitions

-- This section defines a table of Source Address Source objects under the Repeater node.

rptrSrcAddrMgmt	OBJECT IDENTIFIER ::= { rptrSourceAddress 3 }

rptrSrcAddrMgmtSrcAgeInterval	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set source addressing ageing interval."
 ::= {rptrSrcAddrMgmt 1}
-- 

rptrSrcAddrMgmtPortLock	OBJECT-TYPE
SYNTAX		INTEGER {
       		unlock(1),
       		lock(2)
       		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Setting this object to Lock will activate the network port
	security lock."
 ::= {rptrSrcAddrMgmt 2}

rptrSrcAddrMgmtActiveUsers	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get the number of active users on this network."
 ::= {rptrSrcAddrMgmt 3}


-- Repeater Port Group Node

-- The following branch in the repeater MIB tree pertains to individual
-- Repeater Port Group Node

-- The following branch in the repeater MIB tree pertains to individual
-- groups of repeater ports

rptrPortGroup		OBJECT IDENTIFIER ::= { repeaterRev4 2 }

-- Repeater Port Group Management Object Definitions

-- This section defines a table of Port Group Management objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortGrpMgmtTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpMgmtEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGroup 1 }

rptrPortGrpMgmtEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpMgmtEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpMgmtGrpId }
 ::= { rptrPortGrpMgmtTable 1 }

-- 

RptrPortGrpMgmtEntry ::=
  SEQUENCE {
	rptrPortGrpMgmtGrpId
		INTEGER,
	rptrPortGrpMgmtName
		INTEGER,
	rptrPortGrpMgmtPortCount
		INTEGER,
	rptrPortGrpMgmtPortsEnable
		INTEGER,
	rptrPortGrpMgmtPortsOn
		INTEGER,
	rptrPortGrpMgmtPortsOper
		INTEGER
  }

rptrPortGrpMgmtGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
::= {rptrPortGrpMgmtEntry 1}

rptrPortGrpMgmtName		OBJECT-TYPE
SYNTAX		DisplayString (SIZE(20))
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Gets/Sets a name for the specified port group."
 ::= {rptrPortGrpMgmtEntry 2}

rptrPortGrpMgmtPortCount  OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
		"Get total number of ports contained on the board."
 ::= {rptrPortGrpMgmtEntry 3}

rptrPortGrpMgmtPortsEnable    OBJECT-TYPE
SYNTAX      INTEGER {
		noEnable(1),
		enable(2)
		}
ACCESS      read-write
STATUS      mandatory
DESCRIPTION
	"Setting this object to Enable will cause all the ports
	residing in this network segment to be enabled.  Setting
	this object to noEnable will have no effect.  When read
	this object will always return noEnable."
 ::= {rptrPortGrpMgmtEntry 4}
-- 

rptrPortGrpMgmtPortsOn    OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get total number of ON ports on the board."
 ::= {rptrPortGrpMgmtEntry 5}

rptrPortGrpMgmtPortsOper  OBJECT-TYPE
SYNTAX      INTEGER
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get total number of operational ports on the board."
 ::= {rptrPortGrpMgmtEntry 6}
		  

-- Repeater Port Group Statistical Object Definitions

rptrPortGrpStats	OBJECT IDENTIFIER ::= { rptrPortGroup 2 }

-- Repeater Port Group Packet Statistical Object Definitions

-- This section defines a table of Port Group Packet Statistical objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortGrpPktStatsTbl		OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpPktStatsEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGrpStats 1 }

rptrPortGrpPktStatsEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpPktStatsEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpPktStatsId }
 ::= { rptrPortGrpPktStatsTbl 1 }
-- 

RptrPortGrpPktStatsEntry ::=
  SEQUENCE {
	rptrPortGrpPktStatsId	
		INTEGER,
	rptrPortGrpPktStatsPkts	
		Counter,
	rptrPortGrpPktStatsBytes	
		Counter,
	rptrPortGrpPktStatsColls	
		Counter,
	rptrPortGrpPktStatsErrors	
		Counter,
	rptrPortGrpPktStatsAlign	
		Counter,
	rptrPortGrpPktStatsCRC
		Counter,
	rptrPortGrpPktStatsOOW	
		Counter
  }

rptrPortGrpPktStatsId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortGrpPktStatsEntry 1}

rptrPortGrpPktStatsPkts	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets."
 ::= {rptrPortGrpPktStatsEntry 2}

rptrPortGrpPktStatsBytes	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received bytes."
 ::= {rptrPortGrpPktStatsEntry 3}

rptrPortGrpPktStatsColls	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total collisions."
 ::= {rptrPortGrpPktStatsEntry 4}
-- 

rptrPortGrpPktStatsErrors	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total errors."
 ::= {rptrPortGrpPktStatsEntry 5}

rptrPortGrpPktStatsAlign	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total frame alignment errors."
 ::= {rptrPortGrpPktStatsEntry 6}

rptrPortGrpPktStatsCRC	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total CRC errors."
 ::= {rptrPortGrpPktStatsEntry 7}

rptrPortGrpPktStatsOOW	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total out-of-window collisions."
 ::= {rptrPortGrpPktStatsEntry 8}



-- Repeater Port Group Protocol Statistical Object Definitions

-- This section defines a table of Port Group Protocol Statistical objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortGrpProtocolTbl	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpProtocolEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGrpStats 2 }

rptrPortGrpProtocolEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpProtocolEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpProtocolId }
 ::= { rptrPortGrpProtocolTbl 1 }
-- 

RptrPortGrpProtocolEntry ::=
  SEQUENCE {
	rptrPortGrpProtocolId
		INTEGER,
	rptrPortGrpProtocolOSI
		Counter,
	rptrPortGrpProtocolNovell
		Counter,
	rptrPortGrpProtocolBanyan
		Counter,
	rptrPortGrpProtocolDECNet
		Counter,
	rptrPortGrpProtocolXNS
		Counter,
	rptrPortGrpProtocolIP
		Counter,
	rptrPortGrpProtocolCtron
		Counter,
	rptrPortGrpProtocolAppletalk
		Counter,
	rptrPortGrpProtocolOther
		Counter
  }

rptrPortGrpProtocolId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortGrpProtocolEntry 1}

rptrPortGrpProtocolOSI	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received OSI packets."
 ::= {rptrPortGrpProtocolEntry 2}

rptrPortGrpProtocolNovell	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received Novell packets."
 ::= {rptrPortGrpProtocolEntry 3}

rptrPortGrpProtocolBanyan OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received Banyan packets."
 ::= {rptrPortGrpProtocolEntry 4}
-- 

rptrPortGrpProtocolDECNet OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received DECNet packets."
 ::= {rptrPortGrpProtocolEntry 5}

rptrPortGrpProtocolXNS	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received XNS packets."
 ::= {rptrPortGrpProtocolEntry 6}

rptrPortGrpProtocolIP	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received TCP/IP packets."
 ::= {rptrPortGrpProtocolEntry 7}

rptrPortGrpProtocolCtron	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received CTRON Management packets."
 ::= {rptrPortGrpProtocolEntry 8}

rptrPortGrpProtocolAppletalk OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received Appletalk packets."
 ::= {rptrPortGrpProtocolEntry 9}

rptrPortGrpProtocolOther OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received unknown protocol packets."
 ::= {rptrPortGrpProtocolEntry 10 }


-- Repeater Port Group Frame Size Statistical Object Definitions

-- This section defines a table of Port Group Frame Size Statistical objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory
-- 

rptrPortGrpFrameSzTbl	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpFrameSzEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGrpStats 3 }

rptrPortGrpFrameSzEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpFrameSzEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpFrameSzId }
 ::= { rptrPortGrpFrameSzTbl 1 }

RptrPortGrpFrameSzEntry ::=
  SEQUENCE {
	rptrPortGrpFrameSzId
		INTEGER,
	rptrPortGrpFrameSzRunt
		Counter,
	rptrPortGrpFrameSz64To127
		Counter,
	rptrPortGrpFrameSz128To255
		Counter,
	rptrPortGrpFrameSz256To511
		Counter,
	rptrPortGrpFrameSz512To1023
		Counter,
	rptrPortGrpFrameSz1024To1518
		Counter,
	rptrPortGrpFrameSzGiant
		Counter
  }

rptrPortGrpFrameSzId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortGrpFrameSzEntry 1}

rptrPortGrpFrameSzRunt OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size less
	than 64 bytes."
 ::= {rptrPortGrpFrameSzEntry 2}
-- 

rptrPortGrpFrameSz64To127 OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size between
	64 and 127 bytes."
 ::= {rptrPortGrpFrameSzEntry 3}

rptrPortGrpFrameSz128To255 OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size between
	128 and 255 bytes."
 ::= {rptrPortGrpFrameSzEntry 4}

rptrPortGrpFrameSz256To511 OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size between
	256 and 511 bytes."
 ::= {rptrPortGrpFrameSzEntry 5}

rptrPortGrpFrameSz512To1023 OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size between
	512 and 1023 bytes."
 ::= {rptrPortGrpFrameSzEntry 6}

rptrPortGrpFrameSz1024To1518 OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size between
	1024 and 1518 bytes."
 ::= {rptrPortGrpFrameSzEntry 7}

rptrPortGrpFrameSzGiant	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Return this port group's total received packets of size greater
	than 1518 bytes."
 ::= {rptrPortGrpFrameSzEntry 8}

-- 

-- Repeater Port Group Alarm Object Definitions

-- This section defines a table of Port Group Alarm objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortGrpAlarmTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpAlarmEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGroup 3}

rptrPortGrpAlarmEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpAlarmEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpAlarmId }
 ::= { rptrPortGrpAlarmTable 1 }

RptrPortGrpAlarmEntry ::=
  SEQUENCE {
	rptrPortGrpAlarmId
		INTEGER,
	rptrPortGrpAlarmTrafEnable
		INTEGER,
	rptrPortGrpAlarmTrafThreshold
		INTEGER,
	rptrPortGrpAlarmTrafGrpDisable
		INTEGER,
	rptrPortGrpAlarmCollEnable
		INTEGER,
	rptrPortGrpAlarmCollThreshold
		INTEGER,
	rptrPortGrpAlarmCollBdDisable
		INTEGER,
	rptrPortGrpAlarmErrEnable
		INTEGER,
	rptrPortGrpAlarmErrThreshold
		INTEGER,
	rptrPortGrpAlarmErrSource
		INTEGER,
	rptrPortGrpAlarmErrGrpDisable
		INTEGER
  }

rptrPortGrpAlarmId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortGrpAlarmEntry 1}
-- 

rptrPortGrpAlarmTrafEnable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether traffic alarms are enabled/disabled.
	 Set allows for enabling/disabling of traffic alarms."
 ::= {rptrPortGrpAlarmEntry 2}

rptrPortGrpAlarmTrafThreshold OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set packet threshold within the timebase that will cause
	an alarm."
 ::= {rptrPortGrpAlarmEntry 3}

rptrPortGrpAlarmTrafGrpDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a port group to be disabled on a traffic alarm
	condition.  Get will show whether the port group disabling is
	allowed or not."
 ::= {rptrPortGrpAlarmEntry 4}

rptrPortGrpAlarmCollEnable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether collision alarms are enabled/disabled.
	Set allows for enabling/disabling of collision alarms"
 ::= {rptrPortGrpAlarmEntry 5}

rptrPortGrpAlarmCollThreshold OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the number of collisions per good packet within the
	timebase that will cause an alarm."
 ::= {rptrPortGrpAlarmEntry 6}
-- 

rptrPortGrpAlarmCollBdDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a board to be disabled on a collision alarm
	condition.  Get will show whether the board disabling is allowed
	or not."
 ::= {rptrPortGrpAlarmEntry 7}

rptrPortGrpAlarmErrEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether error alarms are enabled/disabled.
	Set allows for enabling/disabling of error alarms"
 ::= {rptrPortGrpAlarmEntry 8}

rptrPortGrpAlarmErrThreshold OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the percentage of errors per good packet within the
	timebase that will cause an alarm."
 ::= {rptrPortGrpAlarmEntry 9}

rptrPortGrpAlarmErrSource OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set a bit encoded map of which errors to include in the
	error sum, as follows:

	CRC_errors 	-	Bit 0 - Least Significant Bit
	runts 		-	Bit 1
	OOW_colls 	-	Bit 2
	align_errs	-	Bit 3
	undefined	-	Bit 4
	Giants 		-	Bit 5"
 ::= {rptrPortGrpAlarmEntry 10}
-- 

rptrPortGrpAlarmErrGrpDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a port group to be disabled on an error alarm
	condition.  Get will show whether the port group disabling is
	allowed or not."
 ::= {rptrPortGrpAlarmEntry 11}


-- Repeater Port Group Source Address Object Definitions

-- This section defines a table of Port Group Soure Address objects
-- under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortGrpSrcAddrTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortGrpSrcAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortGroup 4}

rptrPortGrpSrcAddrEntry	OBJECT-TYPE
SYNTAX		RptrPortGrpSrcAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortGrpSrcAddrId }
 ::= { rptrPortGrpSrcAddrTable 1 }

RptrPortGrpSrcAddrEntry ::=
  SEQUENCE {
	rptrPortGrpSrcAddrId
		INTEGER,
	rptrPortGrpSrcAddrActiveUsers
		INTEGER
  }

rptrPortGrpSrcAddrId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortGrpSrcAddrEntry 1}
-- 

rptrPortGrpSrcAddrActiveUsers OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the total number of active users seen by this port group."
 ::= {rptrPortGrpSrcAddrEntry 2}


-- Repeater Port Node

-- The following branch in the repeater MIB tree pertains to individual
-- repeater ports

rptrPort		OBJECT IDENTIFIER ::= {repeaterRev4 3 }


-- Repeater Port Management Object Definitions

-- This section defines a table of Port Management objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortMgmtTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortMgmtEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 1 }

rptrPortMgmtEntry	OBJECT-TYPE
SYNTAX		RptrPortMgmtEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortMgmtPortId , rptrPortMgmtPortGrpId }
 ::= { rptrPortMgmtTable 1 }

RptrPortMgmtEntry ::=
  SEQUENCE {
	rptrPortMgmtPortId
		INTEGER,
	rptrPortMgmtPortGrpId
		INTEGER,
	rptrPortMgmtName
		DisplayString,
	rptrPortMgmtAdminState
		INTEGER,
	rptrPortMgmtOperState
		INTEGER,
	prtrPortMgmtPortType
		OBJECT IDENTIFIER
  }
-- 

rptrPortMgmtPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortMgmtEntry 1}

rptrPortMgmtPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortMgmtEntry 2}

rptrPortMgmtName			OBJECT-TYPE
SYNTAX		DisplayString (SIZE(20))
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Sets/Gets an ASCII name assigned to this port."
 ::= {rptrPortMgmtEntry 3}

rptrPortMgmtAdminState      OBJECT-TYPE
SYNTAX		INTEGER {
			disable(1),
			enable(2)
			}
ACCESS      read-write
STATUS      mandatory
DESCRIPTION
	"Setting this object to Enable will cause port to be enabled.
	Setting this object to Disable will cause
	the port to be disabled.  When read this object will return
	the state of the object per the last request."
 ::= {rptrPortMgmtEntry 4}
													
rptrPortMgmtOperState        OBJECT-TYPE
SYNTAX      INTEGER {
			notOperational(1),
			operational(2)
			}
ACCESS      read-only
STATUS      mandatory
DESCRIPTION
	"Get port operational status."
 ::= {rptrPortMgmtEntry 5}

	prtrPortMgmtPortType	OBJECT-TYPE
	SYNTAX	OBJECT IDENTIFIER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	    "Uniquely defines the repeater port type.  A authoritative
	    identification for a port type.  By convention, this value
	    is alocated within the SMI enterprises subtree
	    (1.3.6.1.4.1), and provides an easy and unambiguous means to
	    determine the type of repeater port."
	::= { rptrPortMgmtEntry 6 }

																		   
-- 

-- Repeater Port Statistical Object Definitions

rptrPortStats		OBJECT IDENTIFIER ::= { rptrPort 2 }

-- Repeater Port Packet Statistical Object Definitions

-- This section defines a table of Port Packet Statistical objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortPktStatsTbl	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortPktStatsEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortStats 1 }

rptrPortPktStatsEntry	OBJECT-TYPE
SYNTAX		RptrPortPktStatsEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortPktStatsPortId , rptrPortPktStatsPortGrpId }
 ::= { rptrPortPktStatsTbl 1 }

RptrPortPktStatsEntry ::=
  SEQUENCE {
	rptrPortPktStatsPortId
		INTEGER,
	rptrPortPktStatsPortGrpId
		INTEGER,
	rptrPortPktStatsPackets
		Counter,
	rptrPortPktStatsBytes
		Counter,
	rptrPortPktStatsColls
		Counter,
	rptrPortPktStatsErrors
		Counter,
	rptrPortPktStatsAlign
		Counter,
	rptrPortPktStatsCRC
		Counter,
	rptrPortPktStatsOOW
		Counter
  }

rptrPortPktStatsPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortPktStatsEntry 1}
-- 

rptrPortPktStatsPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."

 ::= {rptrPortPktStatsEntry 2}

rptrPortPktStatsPackets	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets."
 ::= {rptrPortPktStatsEntry 3}

rptrPortPktStatsBytes	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received bytes."
 ::= {rptrPortPktStatsEntry 4}

rptrPortPktStatsColls	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total  collisions."
 ::= {rptrPortPktStatsEntry 5}

rptrPortPktStatsErrors	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total errors."
 ::= {rptrPortPktStatsEntry 6}

rptrPortPktStatsAlign	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total frame alignment errors."
 ::= {rptrPortPktStatsEntry 7}

rptrPortPktStatsCRC	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total CRC errors."
 ::= {rptrPortPktStatsEntry 8}
-- 

rptrPortPktStatsOOW	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total out-of-window collisions."
 ::= {rptrPortPktStatsEntry 9}


-- Repeater Port Protocol Statistical Object Definitions

-- This section defines a table of Port Protocol Statistical objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortProtocolTbl	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortProtocolEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPortStats 2 }

rptrPortProtocolEntry	OBJECT-TYPE
SYNTAX		RptrPortProtocolEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortProtocolPortId , rptrPortProtocolPortGrpId }
 ::= { rptrPortProtocolTbl 1 }

RptrPortProtocolEntry ::=
  SEQUENCE {
	rptrPortProtocolPortId
		INTEGER,
	rptrPortProtocolPortGrpId
		INTEGER,
	rptrPortProtocolOSI
		Counter,
	rptrPortProtocolNovell
		Counter,
	rptrPortProtocolBanyan
		Counter,
	rptrPortProtocolDECNet
		Counter,
	rptrPortProtocolXNS
		Counter,
	rptrPortProtocolIP
		Counter,
	rptrPortProtocolCtron
		Counter,
	rptrPortProtocolAppletalk
		Counter,
	rptrPortProtocolOther
		Counter
  }
-- 

rptrPortProtocolPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortProtocolEntry 1}

rptrPortProtocolPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortProtocolEntry 2}

rptrPortProtocolOSI	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received OSI protocol packets."
 ::= {rptrPortProtocolEntry 3}

rptrPortProtocolNovell	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received Novell protocol packets."
 ::= {rptrPortProtocolEntry 4}

rptrPortProtocolBanyan	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received Banyan protocol packets."
 ::= {rptrPortProtocolEntry 5}

rptrPortProtocolDECNet	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received DECNet protocol packets."
 ::= {rptrPortProtocolEntry 6}

rptrPortProtocolXNS	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received XNS protocol packets."
 ::= {rptrPortProtocolEntry 7}
-- 

rptrPortProtocolIP	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received TCP/IP protocol packets."
 ::= {rptrPortProtocolEntry 8}

rptrPortProtocolCtron	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received CTRON Management protocol packets."
 ::= {rptrPortProtocolEntry 9}

rptrPortProtocolAppletalk	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received Appletalk protocol packets."
 ::= {rptrPortProtocolEntry 10}

rptrPortProtocolOther	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received unknown protocol packets."
 ::= {rptrPortProtocolEntry 11}


-- Repeater Port Frame Size Statistical Object Definitions

-- This section defines a table of Port Frame Size Statistical objects
-- under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortFrameSzTbl	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortFrameSzEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"Description goes here."
 ::= { rptrPortStats 3 }

rptrPortFrameSzEntry	OBJECT-TYPE
SYNTAX		RptrPortFrameSzEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	"Description goes here."
INDEX		{ rptrPortFrameSzPortId , rptrPortFrameSzPortGrpId }
 ::= { rptrPortFrameSzTbl 1 }
-- 

RptrPortFrameSzEntry ::=
  SEQUENCE {
	rptrPortFrameSzPortId
		INTEGER,
	rptrPortFrameSzPortGrpId
		INTEGER,
	rptrPortFrameSzRunt
		Counter,
	rptrPortFrameSz64To127
		Counter,
	rptrPortFrameSz128To255
		Counter,
	rptrPortFrameSz256To511
		Counter,
	rptrPortFrameSz512To1023
		Counter,
	rptrPortFrameSz1024To1518
		Counter,
	rptrPortFrameSzGiant
		Counter
  }

rptrPortFrameSzPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortFrameSzEntry 1}

rptrPortFrameSzPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortFrameSzEntry 2}

rptrPortFrameSzRunt	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size less than 64 bytes."
 ::= {rptrPortFrameSzEntry 3}

rptrPortFrameSz64To127	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size between 64 and
	127 bytes."
 ::= {rptrPortFrameSzEntry 4}
-- 

rptrPortFrameSz128To255	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size between 128
	and 255 bytes."
 ::= {rptrPortFrameSzEntry 5}

rptrPortFrameSz256To511	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size between 256
	and 511 bytes."
 ::= {rptrPortFrameSzEntry 6}

rptrPortFrameSz512To1023	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size between 512
	and 1023 bytes."
 ::= {rptrPortFrameSzEntry 7}

rptrPortFrameSz1024To1518	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size between 1024
	and 1518 bytes."
 ::= {rptrPortFrameSzEntry 8}

rptrPortFrameSzGiant	OBJECT-TYPE
SYNTAX		Counter
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Get this port's total received packets of size greater than
	1518 bytes."
 ::= {rptrPortFrameSzEntry 9}

-- 
-- Repeater Port Alarm Object Definitions

-- This section defines a table of Port Alarm objects under the Repeater node.
-- The implementation of this group is optional, but within the group all
-- of the elements are mandatory

rptrPortAlarmTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortAlarmEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 3 }

rptrPortAlarmEntry	OBJECT-TYPE
SYNTAX		RptrPortAlarmEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortAlarmPortId , rptrPortAlarmPortGrpId }
 ::= { rptrPortAlarmTable 1 }

RptrPortAlarmEntry ::=
  SEQUENCE {
	rptrPortAlarmPortId
		INTEGER,
	rptrPortAlarmPortGrpId
		INTEGER,
	rptrPortAlarmTrafEnable
		INTEGER,
	rptrPortAlarmTrafThreshold
		INTEGER,
	rptrPortAlarmTrafPortDisable
		INTEGER,
	rptrPortAlarmCollEnable
		INTEGER,
	rptrPortAlarmCollThreshold
		INTEGER,
	rptrPortAlarmCollPortDisable
		INTEGER,
	rptrPortAlarmErrEnable
		INTEGER,
	rptrPortAlarmErrThreshold
		INTEGER,
	rptrPortAlarmErrSource
		INTEGER,
	rptrPortAlarmErrPortDisable
		INTEGER
  }

rptrPortAlarmPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortAlarmEntry 1}
-- 

rptrPortAlarmPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortAlarmEntry 2}

rptrPortAlarmTrafEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether traffic alarms are enabled/disabled.
	Set allows for enabling/disabling of traffic alarms."
 ::= {rptrPortAlarmEntry 3}

rptrPortAlarmTrafThreshold OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set packet threshold within the timebase that will cause
	an alarm."
 ::= {rptrPortAlarmEntry 4}

rptrPortAlarmTrafPortDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a port to be disabled on a traffic alarm
	condition.  Get will show whether the port disabling is allowed
	or not."
 ::= {rptrPortAlarmEntry 5}

rptrPortAlarmCollEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether collision alarms are enabled/disabled.
	Set allows for enabling/disabling of collision alarms."
 ::= {rptrPortAlarmEntry 6}
-- 
rptrPortAlarmCollThreshold OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the number of collisions per good packet within the
	timebase that will cause an alarm."
 ::= {rptrPortAlarmEntry 7}

rptrPortAlarmCollPortDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a port to be disabled on a collision alarm
	condition.  Get will show whether the port disabling is allowed
	or not."
 ::= {rptrPortAlarmEntry 8}

rptrPortAlarmErrEnable	OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get returns whether error alarms are enabled/disabled.
	Set allows for enabling/disabling of error alarms"
 ::= {rptrPortAlarmEntry 9}

rptrPortAlarmErrThreshold	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set the percentage of errors per good packet within the
	timebase that will cause an alarm."
 ::= {rptrPortAlarmEntry 10}

rptrPortAlarmErrSource	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set a bit encoded map of which errors to include in the
	error sum, as follows:

	CRC_errors 	-	Bit 0 - Least Significant Bit
	runts 		-	Bit 1
	OOW_colls 	-	Bit 2
	align_errs	-	Bit 3
	undefined 	-	Bit 4
	Giants 		-	Bit 5"
 ::= {rptrPortAlarmEntry 11}
-- 

rptrPortAlarmErrPortDisable OBJECT-TYPE
SYNTAX		INTEGER {
		disable(1),
		enable(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Set will permit a port to be disabled on an error alarm condition.
	Get will show whether the port disabling is allowed or not."
 ::= {rptrPortAlarmEntry 12}


-- Repeater Port Redundancy Object Definitions

-- This section defines a table of Port Redundancy objects under the Repeater node.
-- This group of objects may be implemented only if the entire set of
-- redundancy object groups have been implemented.

rptrPortRedundTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortRedundEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 4 }

rptrPortRedundEntry	OBJECT-TYPE
SYNTAX		RptrPortRedundEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortRedundPortId , rptrPortRedundPortGrpId }
 ::= { rptrPortRedundTable 1 }

RptrPortRedundEntry ::=
  SEQUENCE {
	rptrPortRedundPortId
		INTEGER,
	rptrPortRedundPortGrpId
		INTEGER,
	rptrPortRedundCrctNum
		INTEGER,
	rptrPortRedundType
		INTEGER,
	rptrPortRedundStatus
		INTEGER
  }

rptrPortRedundPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortRedundEntry 1}
-- 

rptrPortRedundPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortRedundEntry 2}

rptrPortRedundCrctNum	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set redundant circuit number of redundant circuit that port
	is or is to be associated with."
 ::= {rptrPortRedundEntry 3}

rptrPortRedundType	OBJECT-TYPE
SYNTAX		INTEGER {
		notUsed(1),
		primary(2),
		backup(3)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set redundant port type."
::= { rptrPortRedundEntry 4 }

rptrPortRedundStatus	OBJECT-TYPE
SYNTAX		INTEGER {
		notUsed(1),
		active(2),
		inactive(3)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"Get/Set redundant port status."
 ::= {rptrPortRedundEntry 5}


-- Repeater Port Source Address Object Definitions

-- This section defines a table of Port Source Address
-- objects under the Repeater node.
-- This group of objects may be implemented only if the entire set of
-- this group has been implemented.

rptrPortSrcAddrTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortSrcAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 5 }
-- 

rptrPortSrcAddrEntry	OBJECT-TYPE
SYNTAX		RptrPortSrcAddrEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortSrcAddrPortId , rptrPortSrcAddrPortGrpId }
 ::= { rptrPortSrcAddrTable 1 }

RptrPortSrcAddrEntry ::=
  SEQUENCE {
	rptrPortSrcAddrPortId
		INTEGER,
	rptrPortSrcAddrPortGrpId
		INTEGER,
	rptrPortSrcAddrTopoState
		INTEGER,
	rptrPortSrcAddrForceTrunk
		INTEGER,
	rptrPortSrcAddrActiveUsers
		INTEGER
  }

rptrPortSrcAddrPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortSrcAddrEntry 1}

rptrPortSrcAddrPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortSrcAddrEntry 2}

rptrPortSrcAddrTopoState	OBJECT-TYPE
SYNTAX		INTEGER {
			station(1),
			trunk(2)
			}
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the topological state of the port."
 ::= {rptrPortSrcAddrEntry 3}
-- 

rptrPortSrcAddrForceTrunk	OBJECT-TYPE
SYNTAX		INTEGER {
		noForce(1),
		force(2)
		}
ACCESS		read-write
STATUS		mandatory
DESCRIPTION
	"When this object is set to Force it causes the port
	to be placed into a Trunk topological state whether
	the network traffic would warrant such a state or not.
	When this object is set to NoForce it allows the port
	to assume the topological state it would naturally
	assume based on the network activity acrossed it.
	When read this object reports the current setting."
 ::= {rptrPortSrcAddrEntry 4}

rptrPortSrcAddrActiveUsers	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns the total number of active users seen by this port."
 ::= {rptrPortSrcAddrEntry 5}


-- Repeater Port Source Address List Object Definitions

-- This section defines a table of Port Source Address List 
-- objects under the Repeater node.
-- This group may only be implemented if the entire set of source addressing
-- object groups have been implemented.

rptrPortSrcAddrListTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortSrcAddrListEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 6 }

rptrPortSrcAddrListEntry	OBJECT-TYPE
SYNTAX		RptrPortSrcAddrListEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortSrcAddrListId, rptrPortSrcAddrListPortId , rptrPortSrcAddrListPortGrpId }
 ::= { rptrPortSrcAddrListTable 1 }
-- 

RptrPortSrcAddrListEntry ::=
  SEQUENCE {
	rptrPortSrcAddrListId
		INTEGER,
	rptrPortSrcAddrListPortId
		INTEGER,
	rptrPortSrcAddrListPortGrpId
		INTEGER,
	rptrPortSrcAddrAddressList
		OCTET STRING
  }

rptrPortSrcAddrListId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index associated with the number of address to be returned."
 ::= {rptrPortSrcAddrListEntry 1}

rptrPortSrcAddrListPortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortSrcAddrListEntry 2}

rptrPortSrcAddrListPortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."
 ::= {rptrPortSrcAddrListEntry 3}

rptrPortSrcAddrAddressList	OBJECT-TYPE
SYNTAX		OCTET STRING
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns a source address seen on this port."
 ::= {rptrPortSrcAddrListEntry 4}

-- 

-- Repeater Port Hardware List Object Definitions

-- This section defines a table of Hardware objects under the port node.
-- This group may only be implemented if the entire set of source addressing
-- object groups have been implemented.

rptrPortHardwareTable	OBJECT-TYPE
SYNTAX		SEQUENCE OF RptrPortHardwareEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
 ::= { rptrPort 7 }

rptrPortHardwareEntry	OBJECT-TYPE
SYNTAX		RptrPortHardwareEntry
ACCESS		not-accessible
STATUS		mandatory
DESCRIPTION
	""
INDEX		{ rptrPortHardwarePortId , rptrPortHardwarePortGrpId }
 ::= { rptrPortHardwareTable 1 }

RptrPortHardwareEntry ::=
  SEQUENCE {
	rptrPortHardwarePortId
		INTEGER,
	rptrPortHardwarePortGrpId
		INTEGER,
	rptrPortHardwareSegStatus
		INTEGER,
	rptrPortHardwareLinkStatus
		INTEGER
  }

rptrPortHardwarePortId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port for which the information in this
	table pertains."
 ::= {rptrPortHardwareEntry 1}

rptrPortHardwarePortGrpId	OBJECT-TYPE
SYNTAX		INTEGER
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns an index to a port group for which the information in
	this table pertains."

 ::= {rptrPortHardwareEntry 2}
-- 

rptrPortHardwareSegStatus	OBJECT-TYPE
SYNTAX		INTEGER {
			notSegmented(1),
			segmented(2)
			}
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns port segmentation status."
 ::= {rptrPortHardwareEntry 3}

rptrPortHardwareLinkStatus	OBJECT-TYPE
SYNTAX		INTEGER {
			notLinked(1),
			linked(2),
			notApplicable(3)
			}
ACCESS		read-only
STATUS		mandatory
DESCRIPTION
	"Returns port link status."
 ::= {rptrPortHardwareEntry 4}


-- 
-- TrapTypes 

--      This section  will describe  the trap  types  that  the
-- repeater section  of the  EMMe can  generate. These  are not
-- objects, but  Object identifers used to indicate the specfic
-- trap. They  are taken  from the  object space  and are  thus
-- documented here.

--      The   SNMP    protocol   provides   a   mechanism   for
-- asynchronusly notifying  management stations  of significant
-- changes in  the network.  This mechanism  is the  SNMP  trap
-- message. This  document will describe the general format for
-- all trap  messages that  Cabletron products will generate as
-- well as the specific traps that the will be generated by the
-- EMMe.

--  Trap Formats

--      The  SNMP  trap  messages  are  composed  of  two  user
-- definable areas: the specific trap type and the VarBindings
-- (eg. the interesting information). The specific trap type is
-- an INTEGER  that is used to determine the specific trap that
-- has occurred. The "interesting information" contains a group
-- of objects  identifiers (OID)  and their values that provide
-- information about the trap.


-- Trap Description
--  PortSegmenting 

-- Specfic Trap Type Code - 0x101

--      When a  port goes from operational to segmented, a trap
-- will be  generated. For  these purposes, the port state will
-- be sampled  every XXX seconds, thus it will be statistically
-- possible to miss oscillating circuits.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortUnsegementing 

-- Specfic Trap Type Code - 0x102

--      When it  is detected  that a  previously segmented port
-- has gone  operational, a  trap will  be generated.   This is
-- also sampled,  thus a  trap may  not be  generated for  each
-- transition.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortLinkUp 

-- Specfic Trap Type Code - 0x103

--      This trap  will be generated when it is determined that
-- MAU has  been attached to the MMAC. This is only appropriate
-- for MIMs that support the concept of a link state.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortLinkDown 

-- Specfic Trap Type Code - 0x104

--      This trap  will be generated when a previously attached
-- MAU  is  removed  or  powered  down.  Again,  this  is  only
-- appropriate for MIM's that support link state.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  NewSourceAddress 

-- Specfic Trap Type Code - 0x105

--      This trap  will be  generated when the MMAC detects the
-- existence of a new source address on one of it's ports.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortSourceAddr {rptrPortSrcAddrListEntry 4}

-- Trap Description
--  SourceAddressTimeout 

-- Specfic Trap Type Code - 0x106

--      This trap  will indicate that the MMAC has not detected
-- a packet  generated by  this source address within a certain
-- timeout.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortSourceAddr {rptrPortSrcAddrListEntry 4}

-- Trap Description
--  BoardRemoval 

-- Specfic Trap Type Code - 0x107

--      This trap  will be generated when the MMAC detects that
-- MIM has been removed.
-- The interesting information will include:

--        BoardIndex {chSlotEntry 1} in the chassisMib 1.3.6.1.4.1.52.4.1.1.2.5.1.1

-- Trap Description
--  BoardInsertion 

-- Specfic Trap Type Code - 0x108

--      This trap  will be  generated when  the MMAC determines
-- that a new board has been inserted.
-- The interesting information will include:

--        BoardIndex {chSlotEntry 1} in the chassisMib 1.3.6.1.4.1.52.4.1.1.2.5.1.1
--        BoardType {chSlotEntry 4} in the chassisMib 1.3.6.1.4.1.52.4.1.1.2.5.1.4

-- Trap Description
--  ActivePortInRedundantCircuitFailed 

-- Specfic Trap Type Code - 0x109

--      This trap  will be  generated when the active port in a
-- redundant circuit has failed polling. This will indicate the
-- activation of redundancy.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortRedundCrt {rptrPortRedundEntry 3}

-- Trap Description
--  RedundantPortActivated 

-- Specfic Trap Type Code - 0x10a

--      This trap  indicates that a new port has been activated
-- in a  redundant circuit.  This does  NOT indicate  that this
-- port is  usable, but  is being tested. If the port fails the
-- above (3.9) trap will be generated.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortRedundCrt {rptrPortRedundEntry 3}

-- Trap Description
--  RedundantPortTestFailed 

-- Specfic Trap Type Code - 0x10b

--      This trap will be generated when the MMAC executes it's
-- periodic redundancy diagnostics and finds on of the ports in
-- a redundant  circuit  has  failed.  This  message  will  not
-- indicate that  redundancy has  been activated, just that the
-- port has failed and should be fixed before it is needed.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortRedundCrt {rptrPortRedundEntry 3}

-- Trap Description
--  BoardTrafficThresholdExceeded 

-- Specfic Trap Type Code - 0x10f

--      This trap  will be  generated when  the  traffic  (good
-- packets per  time interval) has been exceed for a particular
-- MIM.
-- The interesting information will include:

--        BoardTrafficThreshold {rptrPortGrpAlarmEntry 3}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  BoardErrorThresholdExceeded 

-- Specfic Trap Type Code - 0x110

--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets for a particular interval for a particular MIM.
-- This will most likely indicate a bad MIM.
-- The interesting information will include:

--        BoardErrorThreshold {rptrPortGrpAlarmEntry 9}
--        BoardErrorSource {rptrPortGrpAlarmEntry 10}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  BoardCollisionThresholdExceeded 

-- Specfic Trap Type Code - 0x111

--      This trap  will be  generated when  collisions exceed a
-- threshold percentage  of the  good packets  for a particular
-- interval for a particular MIM.
-- The interesting information will include:

--        BoardCollsThreshold {rptrPortGrpAlarmEntry 6}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  PortTrafficThresholdExceeded 

-- Specfic Trap Type Code - 0x112

--      This trap  will be  generated when  the  traffic  (good
-- packets per  time interval) has been exceed for a particular
-- port.
-- The interesting information will include:

--        PortTrafficThreshold {rptrPortAlarmEntry 4}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortErrorThresholdExceeded 

-- Specfic Trap Type Code - 0x113

--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets  for a  particular interval  for  a  particular
-- port.
-- The interesting information will include:

--        PortErrorThreshold {rptrPortAlarmEntry 10}
--        PortErrorSource {rptrPortAlarmEntry 11}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortCollisionThresholdExceeded 

-- Specfic Trap Type Code - 0x114

--      This trap  will be  generated when  collisions exceed a
-- threshold percentage  of the  good packets  for a particular
-- interval for a particular port.
-- The interesting information will include:

--        PortCollsThreshold {rptrPortAlarmEntry 7}
--        RptrTimebase {rptrAlarms 8}
--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  PortTypeChanged

-- Specfic Trap Type Code - 0x115

--   This trap indicates that a port has changed from a 
-- station port to a link port or vice versa.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortTopologyType {rptrPortSrcAddrEntry 3 }


-- Trap Description
--  PortSecurityViolation

-- Specfic Trap Type Code - 0x117

--   This trap is generated when a source address other than those
-- locked to a port is seen.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortSourceAddr {rptrPortSrcAddrListEntry 4} 

-- Trap Description
--  PortViolationReset

-- Specfic Trap Type Code - 0x118 

--   This trap is generated when management intervention has 
-- reset a port after a violation has occured.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  EnvTempWarm

-- Specfic Trap Type Code - 0x119

--   This trap is generated when the device detects that the temperature
-- within a MIM has reached a WARM condition.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  EnvTempHot

-- Specfic Trap Type Code - 0x11A

--   This trap is generated when the device detects that the temperature
-- within a MIM has reached a HOT condition.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  EnvTempNormal

-- Specfic Trap Type Code - 0x11C

--   This trap is generated when the device detects that the temperature
-- within  a MIM has returned to a NORMAL state.
-- The interesting information is:

--        BoardIndex {rptrPortGrpMgmtEntry 1}

-- Trap Description
--  EnvVoltageLow

-- Specfic Trap Type Code - 0x11B

--   This trap is generated when a power supply`s voltage is LOW.
-- The interesting information is:

--        PowerSupply {PowerEntry 1} in the commonMib 1.3.6.1.4.1.52.1.6.1.4.1.1

-- Trap Description
--  EnvVoltageNormal

-- Specfic Trap Type Code - 0x11D

--   This trap is generated when a power supply's voltage
-- has returned to a NORMAL state.
-- The interesting information is:

--        PowerSupply {PowerEntry 1} in the commonMib 1.3.6.1.4.1.52.1.6.1.4.1.1

-- Trap Description
--  FanFail

-- Specfic Trap Type Code - 0x11E

--   This trap is generated when the device detects that the system fans
-- have failed.
-- The interesting information is:

--        None

-- Trap Description
--  FanNormal

-- Specfic Trap Type Code - 0x11F

--   This trap is generated when the device detects that the system fans
-- have returned to normal.
-- The interesting information is:

--        None

-- Trap Description
--  SystemVolatgeLow

-- Specfic Trap Type Code - 0x125

--   This trap is generated when the device detects that the power
-- to the EMMe is low.
-- The interesting information is:

--        None

-- Trap Description
--  SystemVolatgeNormal

-- Specfic Trap Type Code - 0x126

--   This trap is generated when the device detects that the power
-- to the EMMe has returned to normal.
-- The interesting information is:

--        None

-- Trap Description
--  EpimRemoval 

-- Specfic Trap Type Code - 0x127

--      This trap  will be generated when it is detected that an EPIM
-- has been removed.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}

-- Trap Description
--  Epiminsertion 

-- Specfic Trap Type Code - 0x128

--      This trap  will be generated when it is detected that an EPIM
-- has been inserted.
-- The interesting information will include:

--        BoardIndex {rptrPortGrpMgmtEntry 1}
--        PortIndex {rptrPortMgmtEntry 1}
--        PortType {} oid to be determined


-- Trap Description
--  RptrTrafficThresholdExceeded 

-- Specfic Trap Type Code - 0x129

--      This trap  will be  generated when  the  traffic  (good
-- packets per time interval) has been exceed for a network.
-- The interesting information will include:

--        RptrTrafficThreshold {rptrAlarms 2}
--        RptrTimebase {rptrAlarms 8}
--        RptrInterfaceNum {rptrMgmt 6}

-- Trap Description
--  RptrErrorThresholdExceeded 

-- Specfic Trap Type Code - 0x130

--      This  trap  will  be  generated  when  packets  of  the
-- selected error  type exceeds  a threshold  percentage of the
-- good packets for a particular interval for an entire network.
-- The interesting information will include:

--        RptrErrorThreshold {rptrAlarms 6}
--        RptrErrorSource {rptrAlarms 7}
--        RptrTimebase {rptrAlarms 8}
--        RptrInterfaceNum {rptrMgmt 6}

-- Trap Description
--  RptrCollsionThresholdExceeded 

-- Specfic Trap Type Code - 0x131

--      This trap  will be  generated when  collsions exceed  a
-- threshold percentage  of the  good packets  for a particular
-- interval for an entire network.
-- The interesting information will include:

--        RptrCollsThreshold {rptrAlarms 4}
--        RptrTimebase {rptrAlarms 8}
--        RptrInterfaceNum {rptrMgmt 6}

-- Trap Description
--  RptrLockSTATUSChanged

-- Specfic Trap Type Code - 0x132

--   This trap is generated when the status of the address lock 
-- changes for a certain network.
-- The interesting information is:

--        RptrSrcAddrLocked {rptrSrcAddrMgmt 2}
--        RptrInterfaceNum {rptrMgmt 6}

END