CAMBIUM-NETWORKS-INTERF-MIB DEFINITIONS ::= BEGIN

IMPORTS
        OBJECT-TYPE, MODULE-IDENTITY, enterprises,
                Integer32, Counter32, Gauge32, IpAddress
                FROM SNMPv2-SMI
        OBJECT-GROUP
                FROM SNMPv2-CONF
        DateAndTime, TruthValue, DisplayString
                FROM SNMPv2-TC;

cnInterfaces MODULE-IDENTITY
    LAST-UPDATED "202205260000Z" -- May 26, 2022
    ORGANIZATION
        "Cambium Networks Inc."
    CONTACT-INFO
        "Cambium Networks Support"
    DESCRIPTION
        "This module contains MIB definitions with statistics functions
         for cnMatrix."

    REVISION "202205260000Z" -- November 30, 2021
    DESCRIPTION
        "Added ifCnPortCpuStatisticsTable with the folowing prameters:
            - ifCnCpuIndex
            - ifCnCpuRxUcastPkts
            - ifCnCpuRxMcastPkts
            - ifCnCpuRxBcastPkts
            - ifCnCpuRxArpPkts
            - ifCnCpuRxIgmpPkts
            - ifCnCpuRxIpMcastPkts
            - ifCnCpuRxStpPkts
            - ifCnCpuRxLldpPkts
            - ifCnCpuRxDhcpPkts
            - ifCnCpuRxOtherPkts"

    REVISION "202111300000Z" -- November 30, 2021
    DESCRIPTION
        "Updated MIB registration node to fix
        conflict with CAMBIUM-NETWORKS-EEE-MIB."

    REVISION "202104081800Z" -- April 08, 2021
    DESCRIPTION
        "Added ifCnTablePortLinkTransitions with the folowing parameters:
            - ifCnIndex
            - ifCnPortLinkTransitions"

    ::= { enterprises cambium(17713) cnMatrix(24) 11 }

ifCnTablePortLinkTransitions OBJECT-TYPE
    SYNTAX      SEQUENCE OF IfCnEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of interface entries.  The number of entries is
            given by the value of ifCnNumber."
    ::= { cnInterfaces 1 }

ifCnEntry OBJECT-TYPE
    SYNTAX      IfCnEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "An entry containing management information applicable to a
            particular interface."
    INDEX   { ifCnIndex }
    ::= { ifCnTablePortLinkTransitions 1 }

IfCnEntry ::=
    SEQUENCE {
        ifCnIndex               Integer32,
        ifCnPortLinkTransitions Gauge32
    }

ifCnIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "A unique value, greater than zero, for each interface.  It
            is recommended that values are assigned contiguously
            starting from 1.  The value for each interface sub-layer
            must remain constant at least from one re-initialization of
            the entity's network management system to the next re-
            initialization."
    ::= { ifCnEntry 1 }

ifCnPortLinkTransitions OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "The number of Link Up and Link Down transition events
            counted for a port."
    ::= { ifCnEntry 2 }

ifCnPortCpuStatisticsTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF IfCnCpuEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "A list of CPU interface entries. The number of entries is
            given by the value of ifCnCpuIndex."
    ::= { cnInterfaces 2}

ifCnCpuEntry OBJECT-TYPE
    SYNTAX      IfCnCpuEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
            "An entry containing management information applicable to a
            particular interface."
    INDEX       { ifCnCpuIndex }

    ::=  { ifCnPortCpuStatisticsTable 1 }

IfCnCpuEntry ::=
    SEQUENCE  {
        ifCnCpuIndex        Integer32,
        ifCnCpuRxUcastPkts  Counter32,
        ifCnCpuRxMcastPkts  Counter32,
        ifCnCpuRxBcastPkts  Counter32,
        ifCnCpuRxArpPkts    Counter32,
        ifCnCpuRxIgmpPkts   Counter32,
        ifCnCpuRxIpMcastPkts Counter32,
        ifCnCpuRxStpPkts    Counter32,
        ifCnCpuRxLldpPkts   Counter32,
        ifCnCpuRxDhcpPkts   Counter32,
        ifCnCpuRxOtherPkts  Counter32
        }

ifCnCpuIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..2147483647)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "A unique value, greater than zero, for each interface.  It
            is recommended that values are assigned contiguously
            starting from 1.  The value for each interface sub-layer
            must remain constant at least from one re-initialization of
            the entity's network management system to the next re-
            initialization."
    ::= { ifCnCpuEntry 1 }

ifCnCpuRxUcastPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of unicast packets received by the CPU through the
            associated device interface."
    ::= { ifCnCpuEntry 2 }

ifCnCpuRxMcastPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of multicast packets received by the CPU through
            the associated device interface."
    ::= { ifCnCpuEntry 3 }

ifCnCpuRxBcastPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of broadcast packets received by the CPU through
            the associated device interface."
    ::= { ifCnCpuEntry 4 }

ifCnCpuRxArpPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of ARP packets received by the CPU  through the
            associated device interface."
    ::= { ifCnCpuEntry 5 }

ifCnCpuRxIgmpPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of IGMP packets received by the CPU  through the
            associated device interface."
    ::= { ifCnCpuEntry 6 }

ifCnCpuRxIpMcastPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of IP multicast packets received by the CPU
            through the associated device interface."
    ::= { ifCnCpuEntry 7 }

ifCnCpuRxStpPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of STP packets received by the CPU through the
            associated device interface."
    ::= { ifCnCpuEntry 8 }

ifCnCpuRxLldpPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of LLDP packets received by the CPU through the
            associated device interface."
    ::= { ifCnCpuEntry 9 }

ifCnCpuRxDhcpPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of DHCP packets received by the CPU through the
            associated device interface."
    ::= { ifCnCpuEntry 10 }

ifCnCpuRxOtherPkts OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
            "Number of other packets received by the CPU that are not:
              ARP,IGMP, IP Multicast, STP, LLDP, DHCP."
    ::= { ifCnCpuEntry 11 }

END