-- CISCO-IGNITION-MIB.my
--   
-- January 2021, Sherry Chang
--
-- Copyright (c) 2021, 2023 by Cisco Systems, Inc.
-- All rights reserved.
--   
-- *****************************************************************

CISCO-IGNITION-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Counter32,
    NOTIFICATION-TYPE,
    Unsigned32,
    Integer32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE,
    NOTIFICATION-GROUP,
    OBJECT-GROUP
        FROM SNMPv2-CONF
    TruthValue
        FROM SNMPv2-TC
    ciscoMgmt
        FROM CISCO-SMI;


-- ********************************************************************
-- *  MODULE IDENTITY
-- ********************************************************************
ciscoIgnitionMIB MODULE-IDENTITY
    LAST-UPDATED    "202306300000Z"
    ORGANIZATION    "Cisco Systems, Inc."
    CONTACT-INFO
            "Cisco Systems
            Customer Service

            Postal: 170 W Tasman Drive
            San Jose, CA  95134
            USA

            Tel: +1 800 553-NETS

            E-mail: cs-<list>@cisco.com"
    DESCRIPTION
        "This MIB is intended to be implemented on IR1800 devices."
    REVISION        "202306300000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { ciscoMgmt 1061 }

-- Textual Conventions definition will be defined before this line

ipmMIBStatus OBJECT IDENTIFIER
    ::= { ciscoIgnitionMIB 0 }

ipmMIBThreshold OBJECT IDENTIFIER
    ::= { ciscoIgnitionMIB 1 }

ipmMIBConform OBJECT IDENTIFIER
    ::= { ciscoIgnitionMIB 2 }

ipmMIBCompliance OBJECT IDENTIFIER
    ::= { ipmMIBConform 1 }

ipmMIBGroups OBJECT IDENTIFIER
    ::= { ipmMIBConform 2 }

-- table entry type definition

IgnitionStatus ::= TEXTUAL-CONVENTION
    STATUS          current
    DESCRIPTION
        "Ignition Status 
         Bootloader(0): Booting or on bootloader mode,
         PowerOn(1): Normal operating status,
         LowDelay(2): Timing the low voltage shut down,
         OffDelay(3): Timing the ignition off shut down,
         HighDelay(4): Timing the high voltage shut down,
         OnDelay(5): Timing from ignition 'on' to power,
         Monitor(6): Monitor,
         Sleep(7): Sleep,
         Unknown(8): Unknown"
    REFERENCE       "Ignition Status"
    SYNTAX          INTEGER  {
                        bootloader(0),
                        powerOn(1),
                        lowDelay(2),
                        offDelay(3),
                        highDelay(4),
                        onDelay(5),
                        monitor(6),
                        sleep(7),
                        unknown(8)
                    }

-- table definition for ipmIgnitionStatusTable

ipmIgnitionStatusTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF IpmIgnitionStatusEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Table for Ignition Status"
    ::= { ipmMIBStatus 1 }

ipmIgnitionStatusEntry OBJECT-TYPE
    SYNTAX          IpmIgnitionStatusEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry (conceptual row) in the ipmIgnitionStatusTable."
    INDEX           { ipmIgnitionStatusIndex } 
    ::= {  ipmIgnitionStatusTable 1 }

IpmIgnitionStatusEntry ::= SEQUENCE {
        ipmIgnitionStatusIndex  Integer32,
        ipmIgnitionManagement   TruthValue,
        ipmInputVoltage         Unsigned32,
        ipmIgnitionStatus       IgnitionStatus,
        ipmIgnitionSense        TruthValue,
        ipmShutdownTimer        Unsigned32,
        ipmConfigBattery        Integer32
}

-- table definition for ipmIgnitionThresholdTable

ipmIgnitionThresholdTable OBJECT-TYPE
    SYNTAX          SEQUENCE OF IpmIgnitionThresholdEntry 
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "Table for Ignition Threshold"
    ::= { ipmMIBThreshold 1 }

ipmIgnitionThresholdEntry OBJECT-TYPE
    SYNTAX          IpmIgnitionThresholdEntry
    MAX-ACCESS      not-accessible
    STATUS          current
    DESCRIPTION
        "An entry (conceptual row) in the ipmIgnitionThresholdTable."
    INDEX           { ipmIgnitionThresholdIndex } 
    ::= {  ipmIgnitionThresholdTable 1 }

IpmIgnitionThresholdEntry ::= SEQUENCE {
        ipmIgnitionThresholdIndex Integer32,
        ipmUndervoltage           Unsigned32,
        ipmOvervoltage            Unsigned32,
        ipmSenseOn                Unsigned32,
        ipmSenseOff               Unsigned32,
        ipmUndervoltageTimer      Unsigned32,
        ipmOvervoltageTimer       Unsigned32,
        ipmIgnitionOffTimer       Unsigned32 
} 

ipmIgnitionStatusIndex OBJECT-TYPE
    SYNTAX          Integer32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Status Index"
    ::= { ipmIgnitionStatusEntry 1 }

ipmIgnitionManagement OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Management is enable(true) or disable(false)"
    ::= { ipmIgnitionStatusEntry 2 }

ipmInputVoltage OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Input Voltage in millivolts"
    ::= { ipmIgnitionStatusEntry 3 }

ipmIgnitionStatus OBJECT-TYPE
    SYNTAX          IgnitionStatus
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Status"
    ::= { ipmIgnitionStatusEntry 4 }

ipmIgnitionSense OBJECT-TYPE
    SYNTAX          TruthValue
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Sense is enable(true) or disable(false)"
    ::= { ipmIgnitionStatusEntry 5 }

ipmShutdownTimer OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Shutdown Timer in milliseconds to off"
    ::= { ipmIgnitionStatusEntry 6 }

ipmConfigBattery OBJECT-TYPE
    SYNTAX          Integer32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Battery Type (v)"
    ::= { ipmIgnitionStatusEntry 7 }

ipmIgnitionThresholdIndex OBJECT-TYPE
    SYNTAX          Integer32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Threshold Index"
    ::= { ipmIgnitionThresholdEntry 1 }

ipmUndervoltage OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition undervoltage in millivolts"
    ::= { ipmIgnitionThresholdEntry 2 }

ipmOvervoltage OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition overvoltage in millivolts"
    ::= { ipmIgnitionThresholdEntry 3 }

ipmSenseOn OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Sense On in millivolts"
    ::= { ipmIgnitionThresholdEntry 4 }

ipmSenseOff OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition Sense Off in millivolts"
    ::= { ipmIgnitionThresholdEntry 5 }

ipmUndervoltageTimer OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition undervoltage timer in milliseconds"
    ::= { ipmIgnitionThresholdEntry 6 }

ipmOvervoltageTimer OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition overvoltage timer in milliseconds"
    ::= { ipmIgnitionThresholdEntry 7 }

ipmIgnitionOffTimer OBJECT-TYPE
    SYNTAX          Unsigned32
    MAX-ACCESS      read-only
    STATUS          current
    DESCRIPTION
        "Ignition off timer in milliseconds"
    ::= { ipmIgnitionThresholdEntry 8 }

ipmMIBCompliances MODULE-COMPLIANCE
    STATUS          current
    DESCRIPTION
        "This is a default module-compliance
        containing default object groups."
    MODULE          -- this module
    MANDATORY-GROUPS {
                        ipmIgnitionStatusMIBGroup,
                        ipmIgnitionThresholdMIBGroup
                     }
    ::= { ipmMIBCompliance 1 }

-- Units of Conformance

ipmIgnitionStatusMIBGroup OBJECT-GROUP
    OBJECTS         {
                        ipmIgnitionManagement,
                        ipmInputVoltage,
                        ipmIgnitionStatus,
                        ipmIgnitionSense,
                        ipmShutdownTimer,
                        ipmConfigBattery
                    }
    STATUS          current
    DESCRIPTION
        "The is a test group for Ignition Status."
    ::= { ipmMIBGroups 1 }

ipmIgnitionThresholdMIBGroup OBJECT-GROUP
    OBJECTS         {
                        ipmUndervoltage,
                        ipmOvervoltage,
                        ipmSenseOn,
                        ipmSenseOff,
                        ipmUndervoltageTimer,
                        ipmOvervoltageTimer,
                        ipmIgnitionOffTimer
                    }
    STATUS          current
    DESCRIPTION
        "The is a test group for Ignition Thresholds."
    ::= { ipmMIBGroups 2 }
 
END