HM2-TSN-MIB DEFINITIONS ::= BEGIN
-- 
-- ***********************************************************
-- Hirschmann Time Sensitive Network MIB
-- ***********************************************************
--
IMPORTS
 
    MODULE-IDENTITY,  OBJECT-TYPE, 
    Integer32                               FROM SNMPv2-SMI
    hm2ConfigurationMibs,
    HmEnabledStatus                         FROM HM2-TC-MIB
    ieee8021STParametersEntry               FROM IEEE8021-ST-MIB
    TEXTUAL-CONVENTION                      FROM SNMPv2-TC;


hm2TsnMib  MODULE-IDENTITY
    LAST-UPDATED "201802060000Z" -- February 6, 2018
    ORGANIZATION "Hirschmann Automation and Control GmbH"
    CONTACT-INFO
        "Postal:     Stuttgarter Str. 45-51
                     72654 Neckartenzlingen
                     Germany
         Phone:      +49 7127 140
         E-mail:     hac.support@belden.com"
    DESCRIPTION
                 "Hirschmann Time Sensitive Network MIB.
                  Copyright (C) 2018. All Rights Reserved."
 
    REVISION     "201802060000Z" -- February 6, 2018
    DESCRIPTION
                 "Initial version."
    REVISION     "202102190000Z" -- February 19, 2021
    DESCRIPTION
                 "Added hm2TsnTemplateBasedGroup."
    REVISION     "202103150000Z" -- March 15, 2021
    DESCRIPTION
                 "Added hm2TsnConflictMibSESGroup for 
                  SNMP extended error handling. ."           
    ::= { hm2ConfigurationMibs 51 }

-- **************************************************************************************

  Hm2TsnBaseTime ::= TEXTUAL-CONVENTION
    DISPLAY-HINT
      "2d-1d-1d,1d:1d:1d.4d"
    STATUS current
    DESCRIPTION
          "A date-time specification for absolute time entry in a time range.

          field  octets  contents                  range 
          -----  ------  --------                  -----
            1     1-2    year                      0..65536
            2      3     month                     1..12
            3      4     day                       1..31
            4      5     hour                      0..23
            5      6     minutes                   0..59
            6      7     seconds                   0..59
            7    8-11    nanoseconds               0..4294967296

          For example, Oct 9, 2009 at 1:30:45.4566 PM would be
          displayed as:
                  2009-10-9,13:30:45.4566"
    SYNTAX OCTET STRING (SIZE (11))

-- **************************************************************************************  
    
-- 
-- ***********************************************************
-- hm2TsnbMib
-- ***********************************************************
--
hm2TsnNotifications         OBJECT IDENTIFIER ::= { hm2TsnMib 0 }
hm2TsnMibObjects            OBJECT IDENTIFIER ::= { hm2TsnMib 1 }
-- hm2TsnMibConformance     OBJECT IDENTIFIER ::= { hm2TsnMib 2 }
hm2TsnMibSNMPExtensionGroup OBJECT IDENTIFIER ::= { hm2TsnMib 3 }
 
-- 
-- ***********************************************************
-- hm2Tsn Groups 
-- ***********************************************************
--
hm2TsnGroup                 OBJECT IDENTIFIER ::= { hm2TsnMibObjects 1 } 
 
-- ****************************************************************************
-- TSN Group
-- ****************************************************************************
 
hm2TsnAdminState OBJECT-TYPE
            SYNTAX HmEnabledStatus
            MAX-ACCESS read-write
            STATUS current
            DESCRIPTION
                "The TSN protocol group administrative status."
            DEFVAL { disable }
            ::= { hm2TsnGroup 1 }


-- ****************************************************************************
-- Parameters Entry
-- ****************************************************************************

hm2STParametersTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hm2STParametersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        ""
    ::= { hm2TsnMibObjects 2 }

hm2STParametersEntry OBJECT-TYPE
    SYNTAX      Hm2STParametersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        ""
    AUGMENTS { ieee8021STParametersEntry }
    ::= { hm2STParametersTable 1 }

Hm2STParametersEntry ::=
    SEQUENCE {
       hm2STAdminBaseTime               Hm2TsnBaseTime,
       hm2STOperBaseTime                Hm2TsnBaseTime,
       hm2STConfigChangeTime            Hm2TsnBaseTime,
       hm2STPortStatus					INTEGER
     }

hm2STAdminBaseTime OBJECT-TYPE
     SYNTAX      Hm2TsnBaseTime
     MAX-ACCESS  read-write
     STATUS      current
     DESCRIPTION
                 "The administrative value of the BaseTime parameter for the port."
     ::= { hm2STParametersEntry 1 }

hm2STOperBaseTime OBJECT-TYPE
     SYNTAX      Hm2TsnBaseTime
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
                 "The operational value of the BaseTime parameter for the port."
     ::= { hm2STParametersEntry 2 }

hm2STConfigChangeTime OBJECT-TYPE
     SYNTAX      Hm2TsnBaseTime
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
                 "The value of the ConfigChangeTime parameter for the port."
     ::= { hm2STParametersEntry 3 }

hm2STPortStatus OBJECT-TYPE
     SYNTAX      INTEGER { running(1),
                           waitForTimeSync(2),
                           pending(3),
                           disabled(4),
                           error(5)
                        }
     MAX-ACCESS  read-only
     STATUS      current
     DESCRIPTION
                 "The operational value of cycle status on the port"
     ::= { hm2STParametersEntry 4 }


-- ***********************************************************
-- TSN Template Based Group 
-- ***********************************************************

hm2TsnTemplateBasedGroup         OBJECT IDENTIFIER ::= { hm2TsnMibObjects 3 } 

hm2TsnTemplateBasedParametersTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF Hm2TsnTemplateBasedParametersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        ""
    ::= { hm2TsnTemplateBasedGroup 1 }

hm2TsnTemplateBasedParametersEntry OBJECT-TYPE
    SYNTAX      Hm2TsnTemplateBasedParametersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        ""
    AUGMENTS { ieee8021STParametersEntry }
    ::= { hm2TsnTemplateBasedParametersTable 1 }

Hm2TsnTemplateBasedParametersEntry ::=
    SEQUENCE {
       hm2TsnAdminTemplateGcl             INTEGER,
       hm2TsnOperTemplateGcl              INTEGER
     }

hm2TsnAdminTemplateGcl OBJECT-TYPE
            SYNTAX  INTEGER {
                               noop(1),
                               tc7Tc6to0Gb(2),
                               gbTc7Tc6to0(3),
                               tc6to0GbTc7(4),
                               gbTc7GbTc6Tc5to0(5),
                               tc5to0GbTc7GbTc6(6),
                               gbTc6GbTc7Tc5to0(7),
                               gbTc7Tc5to0GbTc6(8),
                               tc7GbTc6Tc5to0Gb(9)
                            }
            MAX-ACCESS      read-write
            STATUS          current
            DESCRIPTION
            "Administrative value of presetting the TSN gate control list 
            with a template.
            
            Writing noop(1) has no effect. When reading this object,
            it returns noop(1).
            
            When writing tc7Tc6to0Gb(2) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            traffic class 7, 
            the second entry represents the traffic classes 6 to 0,
            and the third entry represents a guard band.
            
            When writing gbTc7Tc6to0(3) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            a guard band,
            the second entry represents the traffic class 7,
            and the third entry represents the traffic classes 6 to 0.
            
            When writing tc6to0GbTc7(4) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            the traffic classes 6 to 0,
            the second entry represents a guard band,
            and the third entry represents the traffic class 7.
            
            When writing gbTc7GbTc6Tc5to0(5) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 7,
            the third entry represents a guard band,
            the fourth entry represents the traffic class 6,
            and the fifth entry represents the traffic classes 5 to 0.
            
            When writing tc5to0GbTc7GbTc6(6) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            the traffic classes 5 to 0, 
            the second entry represents a guard band,
            the third entry represents the traffic class 7,
            the fourth entry represents a guard band,
            and the fifth entry represents the traffic class 6.
            
            When writing gbTc6GbTc7Tc5to0(7) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 6,
            the third entry represents a guard band,
            the fourth entry represents the traffic class 7,
            and the fifth entry represents the traffic classes 5 to 0.
            
            When writing gbTc7Tc5to0GbTc6(8) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 7,
            the third entry represents the traffic classes 5 to 0,
            the fourth entry represents a guard band,
            and the fifth entry represents the traffic class 6.

            When writing tc7GbTc6Tc5to0Gb(9) the number of entries (TLVs) in the
            ieee8021STAdminControlList will be preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            traffic class 7, 
            the second entry represents a guard band,
            the third entry represents the traffic class 6,
            the fourth entry represents the traffic classes 5 to 0,
            and the fifth entry represents a guard band.
            "
            DEFVAL { noop }            
            ::= { hm2TsnTemplateBasedParametersEntry 1 }

hm2TsnOperTemplateGcl OBJECT-TYPE
            SYNTAX  INTEGER {
                               noTemplate(1),
                               tc7Tc6to0Gb(2),
                               gbTc7Tc6to0(3),
                               tc6to0GbTc7(4),
                               gbTc7GbTc6Tc5to0(5),
                               tc5to0GbTc7GbTc6(6),
                               gbTc6GbTc7Tc5to0(7),
                               gbTc7Tc5to0GbTc6(8),
                               tc7GbTc6Tc5to0Gb(9)
                            }
            MAX-ACCESS      read-only
            STATUS          current
            DESCRIPTION
            "Operational value of presetting the TSN gate control list with a template.
            
            noTemplate(1) indicates that the TSN gate control list was not presetted
            with a template.
            
            tc7Tc6to0Gb(2) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            traffic class 7,
            the second entry represents the traffic classes 6 to 0,
            and the third entry represents a guard band.
 
            gbTc7Tc6to0(3) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            a guard band,
            the second entry represents the traffic class 7,
            and the third entry represents the traffic classes 6 to 0.
            
            tc6to0GbTc7(4) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 3, 
            in the ieee8021STAdminControlList the first entry represents 
            the traffic classes 6 to 0,
            the second entry represents a guard band,
            and the third entry represents the traffic class 7.

            gbTc7GbTc6Tc5to0(5) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 7,
            the third entry represents a guard band,
            the fourth entry represents the traffic class 6,
            and the fifth entry represents the traffic classes 5 to 0.

            tc5to0GbTc7GbTc6(6) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            the traffic classes 5 to 0, 
            the second entry represents a guard band,
            the third entry represents the traffic class 7,
            the fourth entry represents a guard band,
            and the fifth entry represents the traffic class 6.

            gbTc6GbTc7Tc5to0(7) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 6,
            the third entry represents a guard band,
            the fourth entry represents the traffic class 7,
            and the fifth entry represents the traffic classes 5 to 0.

            gbTc7Tc5to0GbTc6(8) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            a guard band, 
            the second entry represents the traffic class 7,
            the third entry represents the traffic classes 5 to 0,
            the fourth entry represents a guard band,
            and the fifth entry represents the traffic class 6.

            tc7GbTc6Tc5to0Gb(9) indicates that the number of entries (TLVs) in the
            ieee8021STAdminControlList was preassigned to 5, 
            in the ieee8021STAdminControlList the first entry represents
            traffic class 7, 
            the second entry represents a guard band,
            the third entry represents the traffic class 6,
            the fourth entry represents the traffic classes 5 to 0,
            and the fifth entry represents a guard band.
            "         
            ::= { hm2TsnTemplateBasedParametersEntry 2 }

--*****************************************************************************
-- hm2TsnMibSNMPExtensionGroup
--*****************************************************************************
hm2TsnConflictMibSESGroup		OBJECT IDENTIFIER ::= { hm2TsnMibSNMPExtensionGroup 1 }

-- *************************************************************
-- hm2TsnConflictMibSESGroup notifications
-- *************************************************************

hm2TsnGranulaityConflict OBJECT-IDENTITY
            STATUS      current
            DESCRIPTION 
            "Indicates that either the configured cycle time or GCL interval 
             does not conform to the granularity of cycle time range.	 
            For cycle time till 4ms, granularity is 1000ns.
            For cycle time between 4ms and 8ms, granularity is 2000ns.
            For cycle time greater than 8ms, granularity is 4000ns.	 
            "
            ::= { hm2TsnConflictMibSESGroup 1 }
	
hm2TsnGCLTimeIntervalConflit OBJECT-IDENTITY
            STATUS      current
            DESCRIPTION 
            "Indicates that sum of the time interval of all GCL entries exceeds
             the configured cycle time."
            ::= { hm2TsnConflictMibSESGroup 2 }
	
hm2TsnGCLTemplateConflict OBJECT-IDENTITY
            STATUS      current
            DESCRIPTION 
            "Indicates that configured GCL entry does not match to any of the
             available GCL templates."
            ::= { hm2TsnConflictMibSESGroup 3 }
END