-- Box Services MIB overview:
-- Box Services MIB falls under fastPath MIB node of the private subtree.

NETAPP-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN

-- Broadcom Corporation FASTPATH Box Services MIB
-- Copyright Broadcom Corporation(2004-2008) All rights reserved.

-- This SNMP Management Information Specification
-- embodies Broadcom Corporation's confidential and proprietary
-- intellectual property.  Broadcom Corporation retains all title
-- and ownership in the Specification including any revisions.

-- This Specification is supplied "AS IS", Broadcom Corporation
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.


IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
    Unsigned32, Integer32               FROM SNMPv2-SMI
    TEXTUAL-CONVENTION		             	FROM SNMPv2-TC
    DisplayString		                    FROM RFC1213-MIB
    fastPath                            FROM NETAPP-REF-MIB;

    fastPathBoxServices MODULE-IDENTITY
           LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
           ORGANIZATION "Broadcom Corporation"
           CONTACT-INFO
           "                      Customer Support
           Postal:                Broadcom Corporation
				  1030 Swabia Court
				  Suite 400
				  Durham, NC 27703
           Tel:                   +1 919 865 2700"
 
     DESCRIPTION
          "The Broadcom Private MIB for FASTPATH Box Services Feature."

      -- Revision history.
      REVISION
          "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
      DESCRIPTION
          "Postal address updated."
      REVISION
          "200802220000Z" -- 22 Feb 2008 12:00:00 GMT
      DESCRIPTION
          "Broadcom branding related changes."

      ::= { fastPath 43 }

BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
   STATUS  current
   DESCRIPTION
           "The temperature state"
   SYNTAX      INTEGER {
                        low(0),
                        normal(1),
                        warning(2),
                        critical(3),
                        shutdown(4),
                        notpresent(5),
                        notoperational(6)
                       }

--**************************************************************************************
--    boxServicesGroup
--
--    This group provides configuration and status of the Box Services
--    feature.  
--
--**************************************************************************************

	boxServicesGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
  
   --**************************************************************************************
   -- Some scalars
   
    boxServicesNormalTempRangeMin OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
       " Lower boundary of normal temperature range."
    ::= { boxServicesGroup 1 }

    boxServicesNormalTempRangeMax OBJECT-TYPE
      SYNTAX     Integer32 (-100..100)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
       " Upper boundary of normal temperature range."
    ::= { boxServicesGroup 2 }

    boxServicesTemperatureTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
      DEFVAL { enable }
    ::= { boxServicesGroup 3 }

    boxServicesPSMStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Power Supply Module state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 4 }
    
    boxServicesFanStateTrapEnable OBJECT-TYPE
      SYNTAX      INTEGER {
                  enable(1),
                  disable(2)
                  }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
       " Enable or disable Fan state change trap."
      DEFVAL { enable }
    ::= { boxServicesGroup 5 }

boxsPwrUsageHistoryUnitSampleInterval         OBJECT-TYPE 
         SYNTAX      INTEGER (30..86400)
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
            "Interval at which power consumption data needs to be collected."

         ::= { boxServicesGroup 10 }

boxsPwrUsageHistoryUnitMaxSamples         OBJECT-TYPE 
         SYNTAX      INTEGER (1..168)
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
            "Maximum number of samples to keep."

         ::= { boxServicesGroup 11 }


    boxServicesThermalShutdownSensor         OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The number of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 13 }

    boxServicesThermalShutdownTemperature    OBJECT-TYPE 
         SYNTAX      Unsigned32
         MAX-ACCESS  accessible-for-notify
         STATUS      current
         DESCRIPTION
            "The temperature of the sensor which initiated thermal shutdown."

         ::= { boxServicesGroup 14 }

   --**************************************************************************************
   -- boxServicesFans

    boxServicesFansTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Fan"
         ::= { boxServicesGroup 6 }

    boxServicesFansEntry OBJECT-TYPE
         SYNTAX      BoxServicesFansEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Fan Entry"
         INDEX { boxServicesFansIndex }
         ::= { boxServicesFansTable 1 }

    BoxServicesFansEntry ::= SEQUENCE {
	  boxServicesFansIndex
              Integer32,
          boxServicesFanItemType
              INTEGER,
          boxServicesFanItemState
              INTEGER,
          boxServicesFanSpeed
              Integer32,
          boxServicesFanDutyLevel
              Integer32
          }

    boxServicesFansIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of fan table entry"
         ::= { boxServicesFansEntry 1 }

    boxServicesFanItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of fan"
         ::= { boxServicesFansEntry 2 }


    boxServicesFanItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  nopower(4),
                                  powering(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of fan"
         ::= { boxServicesFansEntry 3 }


      boxServicesFanSpeed OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The speed of fan"
         ::= { boxServicesFansEntry 4}
         
      boxServicesFanDutyLevel OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The duty level of fan, in percents"
         ::= { boxServicesFansEntry 5}

   --**************************************************************************************
   -- boxServicesPowSupplies

    boxServicesPowSuppliesTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Power supply"
         ::= { boxServicesGroup 7 }

    boxServicesPowSuppliesEntry OBJECT-TYPE
         SYNTAX      BoxServicesPowSuppliesEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Power Supply Entry"
         INDEX { boxServicesPowSupplyIndex }
         ::= { boxServicesPowSuppliesTable 1 }

    BoxServicesPowSuppliesEntry ::= SEQUENCE {
	  boxServicesPowSupplyIndex
              Integer32,
          boxServicesPowSupplyItemType
              INTEGER,
          boxServicesPowSupplyItemState
              INTEGER
          }

    boxServicesPowSupplyIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of power supply table entry"
         ::= { boxServicesPowSuppliesEntry 1 }

    boxServicesPowSupplyItemType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6) 
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of power supply"
         ::= { boxServicesPowSuppliesEntry 2 }


    boxServicesPowSupplyItemState OBJECT-TYPE
             SYNTAX      INTEGER {
                                  notpresent(1),
                                  operational(2),
                                  failed(3),
                                  nopower(4),
                                  powering(5),
                                  notpowering(6),
                                  incompatible(7)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The status of power supply."
         ::= { boxServicesPowSuppliesEntry 3 }


 -- Box Services Unit Power Usage History table
    boxsUnitPwrUsageHistoryTable OBJECT-TYPE
         SYNTAX      SEQUENCE OF BoxsUnitPwrUsageHistoryEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
            "A table providing configuration and status of Power Usage History feature"

         ::= { boxServicesGroup 9 }

boxsUnitPwrUsageHistoryEntry OBJECT-TYPE
         SYNTAX      BoxsUnitPwrUsageHistoryEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Power Usage History Table for a Unit."
         INDEX   { boxsPwrUsageHistoryUnitIndex, boxsPwrUsageHistoryUnitSampleIndex }
         ::= { boxsUnitPwrUsageHistoryTable 1 }


    BoxsUnitPwrUsageHistoryEntry::=
         SEQUENCE {
            boxsPwrUsageHistoryUnitIndex
                INTEGER,
            boxsPwrUsageHistoryUnitSampleIndex         
                INTEGER,
            boxsPwrUsageHistoryUnitSampleTime
                DisplayString,
            boxsPwrUsageHistoryUnitPowerConsumption
                INTEGER,
            boxsPwrUsageHistoryStackPowerConsumption
                INTEGER
         }

boxsPwrUsageHistoryUnitIndex OBJECT-TYPE
         SYNTAX      INTEGER (1..8)
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
            "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. 
            A non-zero value indicates the unitIndex for the corresponding unit 
            entry in the Power Usage History Table."

         ::= { boxsUnitPwrUsageHistoryEntry 1 }

boxsPwrUsageHistoryUnitSampleIndex         OBJECT-TYPE 
         SYNTAX      INTEGER (1..2147483647)
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
            "This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. 
            A non-zero value indicates the sampleIndex for the corresponding sample 
            entry in the Power Usage History Table."

         ::= { boxsUnitPwrUsageHistoryEntry 2 }

boxsPwrUsageHistoryUnitSampleTime         OBJECT-TYPE 
         SYNTAX      DisplayString (SIZE(1..32))
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
            "Time at which the Sample was collected."

         ::= { boxsUnitPwrUsageHistoryEntry 3}

boxsPwrUsageHistoryUnitPowerConsumption         OBJECT-TYPE 
         SYNTAX      INTEGER
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
            "Power Consumption (mWatts) at the time of collecting the given sample."

         ::= { boxsUnitPwrUsageHistoryEntry 4 }

boxsPwrUsageHistoryStackPowerConsumption         OBJECT-TYPE 
         SYNTAX      INTEGER
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
            "Power Consumption (mWatts) per Stack at the time of collecting the given sample."

         ::= { boxsUnitPwrUsageHistoryEntry 5 }
   --**************************************************************************************
   -- boxServicesTempSensors


    boxServicesTempSensorsTable OBJECT-TYPE
         SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Temperature sensor"
         ::= { boxServicesGroup 8 }


    boxServicesTempSensorsEntry OBJECT-TYPE
         SYNTAX      BoxServicesTempSensorsEntry
         MAX-ACCESS  not-accessible
         STATUS      current
         DESCRIPTION
                     "Box Services Temperature Sensor Entry"
         INDEX { boxServicesTempSensorIndex }
         ::= { boxServicesTempSensorsTable 1 }

    BoxServicesTempSensorsEntry ::= SEQUENCE {
          boxServicesTempSensorIndex
              Integer32,
          boxServicesTempSensorType
              INTEGER,
          boxServicesTempSensorState
              BoxsTemperatureStatus,
          boxServicesTempSensorTemperature
              Integer32
          }
 
    boxServicesTempSensorIndex OBJECT-TYPE
         SYNTAX      Integer32 (0..2147483647)
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "Unique index of temperature sensor table entry"
         ::= { boxServicesTempSensorsEntry 1 }


    boxServicesTempSensorType OBJECT-TYPE
             SYNTAX      INTEGER {
                                  fixed(1),
                                  removable(2),
                                  fixedAC(3),
                                  removableDC(4),
                                  fixedDC(5),
                                  removableAC(6)
                                 }
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
                     "The type of temperature sensor"
         ::= { boxServicesTempSensorsEntry 2 }


    boxServicesTempSensorState OBJECT-TYPE
         SYNTAX      BoxsTemperatureStatus 
         MAX-ACCESS  read-only
         STATUS      obsolete
         DESCRIPTION
                     "The state of temperature sensor"
         ::= { boxServicesTempSensorsEntry 3 }


      boxServicesTempSensorTemperature OBJECT-TYPE
             SYNTAX      Integer32
             MAX-ACCESS  read-only
             STATUS      current
             DESCRIPTION
                          "The temperature value reported by sensor"
         ::= { boxServicesTempSensorsEntry 4 }

    boxServicesTempUnitTable OBJECT-TYPE
        SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Temperature status table"
        ::= { boxServicesGroup 15 }

    boxServicesTempUnitEntry OBJECT-TYPE
        SYNTAX      BoxServicesTempUnitEntry
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Box Services Temperature Unit Entry"
        INDEX { boxServicesTempUnitIndex }
        ::= { boxServicesTempUnitTable 1 }

    BoxServicesTempUnitEntry ::= SEQUENCE {
        boxServicesTempUnitIndex
           Unsigned32,
        boxServicesTempUnitState
           BoxsTemperatureStatus,
        boxServicesTempUnitTemperature
           Integer32
        }

    boxServicesTempUnitIndex OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only 
        STATUS      current
        DESCRIPTION
            "Unit index for an entry in the Box Services Temperature Unit Table"
        ::= { boxServicesTempUnitEntry 1 }

    boxServicesTempUnitState OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus 
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The temperature state of the unit"
        ::= { boxServicesTempUnitEntry 2 }

    boxServicesTempUnitTemperature OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The highest temperature currently reported by any sensor on the unit"
        ::= { boxServicesTempUnitEntry 3 }
--**************************************************************************************
--    boxServicesNotificationsGroup
--
--    This group provides notification definitions for the Box Services
--    feature.  
--
--**************************************************************************************

	boxServicesNotificationsGroup               OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }

   --**************************************************************************************
   -- boxServices notification definitions

      boxsItemStateChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             insertion(1),
             removal(2),
             becomeoperational(3),
             failure(4),
	     losepower(5)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes states of the fan or power supply.
           
             insertion          - hot-pluggable fan or power supply was inserted
             removal            - hot-pluggable fan or power supply was removed
             becomeoperational  - fan or power supply became operational after failure state
             failure            - fan or power supply failure happened, i.e. it is not able to perform its functions
             losepower          - a power supply was operational, but the power to it has been disconnected or has failed"
        ::= { boxServicesNotificationsGroup 1 }

      boxsTemperatureChangeEvent OBJECT-TYPE
        SYNTAX INTEGER  {
             abovethreshold(1),
             belowthreshold(2),
             withinnormalrange(3)
        }
        MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
           "This event describes change of the temperature. 
           To avoid flipping on boundary conditions, it is allowed to send the trap 
           taking into account some margin around thresholds.
           
             abovethreshold     - temperature increased and crossed upper threshold value
             belowthreshold     - temperature decreased and crossed lower threshold value
             withinnormalrange  - temperature returned to normal range (between threshold)"
        ::= { boxServicesNotificationsGroup 2 }

    boxsTemperatureStatusCurrentEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the current status of a switch."
        ::= { boxServicesNotificationsGroup 3 }

    boxsTemperatureStatusPreviousEvent OBJECT-TYPE
        SYNTAX      BoxsTemperatureStatus
        MAX-ACCESS  accessible-for-notify
        STATUS      current
        DESCRIPTION
            "This event describes the previous status of a switch."
        ::= { boxServicesNotificationsGroup 4 }



--**************************************************************************************
--   Traps
--**************************************************************************************

     fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }



     boxsFanStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesFansIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when fan state change happens."
         ::= { fastPathBoxServicesTraps 1 }

     boxsPowSupplyStateChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesPowSupplyIndex,
                      boxsItemStateChangeEvent
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when power supply state change happens."
         ::= { fastPathBoxServicesTraps 2 }


     boxsTemperatureChange NOTIFICATION-TYPE
         OBJECTS {
                      boxServicesTempSensorIndex,
                      boxsTemperatureChangeEvent
                 }
         STATUS             obsolete
         DESCRIPTION
             "Trap is sent when temperature is changing and crossing any of the thresholds"
         ::= { fastPathBoxServicesTraps 3 }


     boxsThermalShutdown NOTIFICATION-TYPE
         OBJECTS {
                   boxServicesThermalShutdownSensor,
                   boxServicesThermalShutdownTemperature
                 }
         STATUS             current
         DESCRIPTION
             "Trap is sent when thermal shutdown is initiated."
         ::= { fastPathBoxServicesTraps 4 }


    boxsTemperatureStateChange NOTIFICATION-TYPE
        OBJECTS {
                     boxServicesTempUnitIndex,
                     boxsTemperatureStatusCurrentEvent,
                     boxsTemperatureStatusPreviousEvent
                }
        STATUS             current
        DESCRIPTION
            "Trap is sent when the system temperature crosses a threshold. 
            To avoid rapid flapping between states, a hysteresis may
            be applied."
        ::= { fastPathBoxServicesTraps 5 }

--**************************************************************************************
--    Locator LED manage group
--
--    This group provides manage definitions for the Locator LED feature.  
--
--**************************************************************************************

    boxsLocatorLedConfigGroup                 OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }

    boxsLocatorLedUnit OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Spesifies unit number where Locator LED should blink on.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
          ::= { boxsLocatorLedConfigGroup 1 }

    boxsLocatorLedTime OBJECT-TYPE
         SYNTAX      INTEGER
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Indicates time period in seconds for Locator LED blinking.
                      The range is from 20 to 3600 seconds.
                      The dafault value is 20 seconds.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         DEFVAL { 20 }
          ::= { boxsLocatorLedConfigGroup 2 }

    boxsLocatorLedEnable OBJECT-TYPE
         SYNTAX      INTEGER {
                       disable(0), 
                       enable(1)
                     }
         MAX-ACCESS  read-write
         STATUS      current
         DESCRIPTION
                     "Starts the Locator LED blinking.
                      If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
                      If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
                      This is write-only value. It always returns '0' on request
                      if the Locator Led feature is supported."
         ::= { boxsLocatorLedConfigGroup 3 }

END