-- Open Network Linux Environmental Sensor MIB
-- ----------------------------------------------------------------------

OCP-ONL-SENSOR-MIB DEFINITIONS ::= BEGIN

IMPORTS
    OBJECT-TYPE, MODULE-IDENTITY, Integer32, enterprises, Gauge32 FROM SNMPv2-SMI
    DisplayString                                         FROM SNMPv2-TC
    ocp                                                   FROM OCP-MIB
    OpenNetworkLinux                                      FROM OCP-ONL-MIB;

onlSensors MODULE-IDENTITY
     LAST-UPDATED "201605140000Z"
     ORGANIZATION "Open Compute Project"
     CONTACT-INFO "http://www.opencompute.org"
     DESCRIPTION
        "This MIB describes objects for sensors used in Open Network Linux."
     REVISION "201605140000Z"
     DESCRIPTION "Initial revision"
     ::= { OpenNetworkLinux 2 }

--
-- TEMPERATURE SENSORS
--
onlTempSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF ONLTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of temperature sensors and their values."
    ::= { onlSensors 1 }

onlTempSensorsEntry OBJECT-TYPE
    SYNTAX      ONLTempSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { onlTempSensorsIndex }
    ::= { onlTempSensorsTable 1 }

ONLTempSensorsEntry ::= SEQUENCE {
    onlTempSensorsIndex    Integer32,
    onlTempSensorsDevice   DisplayString,
    onlTempSensorsStatus   Integer32,
    onlTempSensorsValue    Gauge32
}

onlTempSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { onlTempSensorsEntry 1 }

onlTempSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the temperature sensor we are reading."
    ::= { onlTempSensorsEntry 2 }

onlTempSensorsStatus OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of this sensor.
         0: missing
         1: good
         2: failed."
    ::= { onlTempSensorsEntry 3 }

onlTempSensorsValue OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The temperature of this sensor in mC."
    ::= { onlTempSensorsEntry 4 }

--
-- FAN SENSORS
--
onlFanSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF ONLFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of fan sensors and their values."
    ::= { onlSensors 2 }

onlFanSensorsEntry OBJECT-TYPE
    SYNTAX      ONLFanSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { onlFanSensorsIndex }
    ::= { onlFanSensorsTable 1 }

ONLFanSensorsEntry ::= SEQUENCE {
    onlFanSensorsIndex    Integer32,
    onlFanSensorsDevice   DisplayString,
    onlFanSensorsStatus   Integer32,
    onlFanSensorsFlowType DisplayString,
    onlFanSensorsRPM      Gauge32,
    onlFanSensorsPct      Gauge32,
    onlFanSensorsModel    DisplayString,
    onlFanSensorsSerial   DisplayString
}

onlFanSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { onlFanSensorsEntry 1 }

onlFanSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the fan sensor we are reading."
    ::= { onlFanSensorsEntry 2 }

onlFanSensorsStatus OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the fan.
         0: missing
         1: good
         2: failed."
    ::= { onlFanSensorsEntry 3 }

onlFanSensorsFlowType OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Flow type of the fan.
         unknown: unknown type
         f2b: front to back
         b2f: back to front."
    ::= { onlFanSensorsEntry 4 }

onlFanSensorsRPM OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The rotation speed of the fan in RPM."
    ::= { onlFanSensorsEntry 5 }

onlFanSensorsPct OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The percentage of the fan."
    ::= { onlFanSensorsEntry 6 }

onlFanSensorsModel OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The model of the fan sensor we are reading."
    ::= { onlFanSensorsEntry 7 }

onlFanSensorsSerial OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The serial number of the fan sensor we are reading."
    ::= { onlFanSensorsEntry 8 }

--
-- PSU SENSORS
--
onlPSUSensorsTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF ONLPSUSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table of power suply unit sensors and their values."
    ::= { onlSensors 3 }

onlPSUSensorsEntry OBJECT-TYPE
    SYNTAX      ONLPSUSensorsEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry containing a device and its statistics."
    INDEX       { onlPSUSensorsIndex }
    ::= { onlPSUSensorsTable 1 }

ONLPSUSensorsEntry ::= SEQUENCE {
    onlPSUSensorsIndex    Integer32,
    onlPSUSensorsDevice   DisplayString,
    onlPSUSensorsStatus   Integer32,
    onlPSUSensorsCurrentType DisplayString,
    onlPSUSensorsModel	 DisplayString,
    onlPSUSensorsVin      Gauge32,
    onlPSUSensorsVout     Gauge32,
    onlPSUSensorsIin      Gauge32,
    onlPSUSensorsIout     Gauge32,
    onlPSUSensorsPin      Gauge32,
    onlPSUSensorsPout     Gauge32,
    onlPSUSensorsSerial   DisplayString
}

onlPSUSensorsIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Reference index for each observed device."
    ::= { onlPSUSensorsEntry 1 }

onlPSUSensorsDevice OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The name of the device we are reading."
    ::= { onlPSUSensorsEntry 2 }

onlPSUSensorsStatus OBJECT-TYPE
    SYNTAX      Integer32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The status of the PSU.
         0: missing
         1: good
         2: failed."
    ::= { onlPSUSensorsEntry 3 }

onlPSUSensorsCurrentType OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The current type of the PSU."
    ::= { onlPSUSensorsEntry 4 }

onlPSUSensorsModel OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The model of the PSU."
    ::= { onlPSUSensorsEntry 5 }

onlPSUSensorsVin OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The input voltage in mV."
    ::= { onlPSUSensorsEntry 6 }

onlPSUSensorsVout OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The output voltage in mV."
    ::= { onlPSUSensorsEntry 7 }

onlPSUSensorsIin OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The input current in mA."
    ::= { onlPSUSensorsEntry 8 }

onlPSUSensorsIout OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The output current in mA."
    ::= { onlPSUSensorsEntry 9 }

onlPSUSensorsPin OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The input power in mW."
    ::= { onlPSUSensorsEntry 10 }

onlPSUSensorsPout OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The output power in mW."
    ::= { onlPSUSensorsEntry 11 }

onlPSUSensorsSerial OBJECT-TYPE
    SYNTAX      DisplayString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The serial number of the PSU."
    ::= { onlPSUSensorsEntry 12 }

END