--    SyncE Proprietary MIB Definition

--    This file explains the proprietary MIB implemented
--    for SyncE (Synchronous Ethernet) that conforms to ITU-T G.8264
--    and ITU-T G.781

SyncE-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Integer32,
    Unsigned32, enterprises
        FROM SNMPv2-SMI
    TruthValue , RowStatus
        FROM SNMPv2-TC
    InterfaceIndex
        FROM IF-MIB;

fsSynceMIB MODULE-IDENTITY
    LAST-UPDATED "201302150000Z"
    -- February 15, 2013

    ORGANIZATION "Super Micro Computer Inc."

    CONTACT-INFO "support@Supermicro.com"

    DESCRIPTION
       "This file is proprietary MIB for SyncE (Synchronous Ethernet)
       implementation that confirms to standard ITU-T G.8264"

    REVISION "201302150000Z"

    DESCRIPTION
       "This file is proprietary MIB for SyncE (Synchronous Ethernet)
       implementation that confirms to standard ITU-T G.8264"


   ::= { enterprises supermicro-computer-inc(10876) super-switch(101) extended(2) 79 }

fsSynceObjects          OBJECT IDENTIFIER ::= { fsSynceMIB 1 }
fsSynceNotifications    OBJECT IDENTIFIER ::= { fsSynceMIB 2 }

--
-- FS SyncE MIB Objects
--

fsSynceGeneralGroup             OBJECT IDENTIFIER ::= { fsSynceObjects 1 }
fsSynceInterfaceConfiguration   OBJECT IDENTIFIER ::= { fsSynceObjects 2 }

-- Scalar objects

fsSynceGlobalSysCtrl OBJECT-TYPE
   SYNTAX      INTEGER {
                        start(1),
                        shutdown(2)
                      }
   MAX-ACCESS  read-write
   STATUS      current
   DESCRIPTION
      "This object is used to initialise/de-initialise the module"
   DEFVAL  { start }
   ::= { fsSynceGeneralGroup 1 }


-- SyncE Table
-- It is used to store SyncE module related information.
-- Implements multiple instance feature in SyncE Module

fsSynceTable OBJECT-TYPE
    SYNTAX SEQUENCE OF FsSynceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table contains information about SyncE module
        at global level"
    ::= { fsSynceGeneralGroup 2 }

fsSynceEntry OBJECT-TYPE
    SYNTAX      FsSynceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Contains information about parameters of a switch/router
        instance. The entry in this table is created using the
        fsSynceContextRowStatus object only if the virtual context is
        existing in the system and deleted using fsSynceContextRowStatus
        when the virtual context is deleted from the system"
    INDEX { fsSynceContextId }
    ::= { fsSynceTable 1 }

FsSynceEntry ::=
    SEQUENCE {
        fsSynceContextId Integer32,
        fsSynceTraceOption Unsigned32,
        fsSynceQLMode INTEGER,
        fsSynceQLValue Unsigned32,
        fsSynceSSMOptionMode INTEGER,
        fsSynceSelectedInterface InterfaceIndex,
        fsSynceContextRowStatus RowStatus
    }

fsSynceContextId OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object is a unique context identifier for each entry.
        Each virtual context will be able to run SyncE protocol individually
        and will be distinguished by this object."
    ::= { fsSynceEntry 1 }

fsSynceTraceOption OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This variable governs the trace levels in the SyncE module.

        A four byte integer is used for enabling the trace level.
        Each bit in the four byte integer represents a particular
        trace level.
        The mapping between the bit positions & the trace level is
        as follows:
          Bit 0 - Init and Shutdown traces
          Bit 1 - Management traces
          Bit 2 - Data Path traces [NOT REQUIRED IN SYNCE]
          Bit 3 - Control Plane traces
          Bit 4 - Packet Dump traces
          Bit 5 - Traces related to all resources except buffers
          Bit 6 - All Failure traces
          Bit 7 - Buffer allocation/release traces

          Bit 16 - SYNCE Function Entry traces
          Bit 17 - SYNCE Function Exit traces
          Bit 18 - SYNCE Critical traces

        The remaining bits are unused. Combination of levels are
        also allowed.

        For example if the bits 19 and 20 are set, then the trace
        statement related to discovery and remote loopback related
        messages will be printed.

        The user has to enter the corresponding integer value for the
        bits set. For example if bits 8 and 9 are to be set ,then user
        has to give the value 0x300."
    DEFVAL  { '00000040'H }
   ::= { fsSynceEntry 2 }

fsSynceQLMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    disabled(0),
                    enabled(1)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to configure QL Enable/Disable mode for
        the selection process in SyncE module.
        The default value of this object is Enabled.
        In the disabled state the quality level of the source will not
        be considered as a parameter for selecting the source among other
        sources for synchronizing the clock; Instead of QL, priority of
        the interface will be used in selecting the best source among
        SyncE sources."
    DEFVAL  { 1 }
    ::= { fsSynceEntry 3 }

fsSynceQLValue OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the QL value selected through the clock selection
        process. The value of this object shall be used while transmitting the
        SSM packets.
        If this value is set by user then automatic selection of clock source
        will be disabled. It is assumed in this case that some external source
        is used to synchronize the system clock.
        The default value of this object is do not use DNU(15)."
    DEFVAL { 15 }
    ::= { fsSynceEntry 4 }

fsSynceSSMOptionMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    option1(1),
                    option2Gen1(2),
                    option2Gen2(3)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object is used to select Option 1(Europe) or Option 2(America)
        clocks in SyncE."
    DEFVAL { 1 }
    ::= { fsSynceEntry 5 }

fsSynceSelectedInterface OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object represent the currently selected interface which QL value
        is being used for transmitting QL in SSM packets."
    ::= { fsSynceEntry 6 }

fsSynceContextRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Used for creation/deletion of enteries in the table"
    ::= { fsSynceEntry 7 }

--SyncE Interface table

fsSynceIfTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FsSynceIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Table containing configuration information on SyncE interfaces."
    ::= { fsSynceInterfaceConfiguration 1 }

fsSynceIfEntry OBJECT-TYPE
    SYNTAX      FsSynceIfEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This object contains SyncE configuration information of an interface."
    INDEX { fsSynceIfIndex }
    ::= { fsSynceIfTable 1 }

FsSynceIfEntry ::=
        SEQUENCE {
            fsSynceIfIndex InterfaceIndex,
            fsSynceIfSynceMode TruthValue,
            fsSynceIfEsmcMode INTEGER,
            fsSynceIfPriority Integer32,
            fsSynceIfQLValue INTEGER,
            fsSynceIfIsRxQLForced TruthValue,
            fsSynceIfLockoutStatus INTEGER,
            fsSynceIfSignalFail TruthValue,
            fsSynceIfPktsTx Unsigned32,
            fsSynceIfPktsRx Unsigned32,
            fsSynceIfPktsRxDropped Unsigned32,
            fsSynceIfPktsRxErrored Unsigned32,
            fsSynceIfRowStatus RowStatus
        }

fsSynceIfIndex OBJECT-TYPE
    SYNTAX      InterfaceIndex
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Uniquely identifies an interface in the system."
    ::= { fsSynceIfEntry 1 }

fsSynceIfSynceMode OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object controls enabling/disabling of Synchronous Ethernet
        feature on an interface. In the disabled state, SyncE
        packets will not considered for synchronizing the system clock.
        The default value of this object is disabled."
    DEFVAL  { false }
    ::= { fsSynceIfEntry 2 }

fsSynceIfEsmcMode OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    rx(1),
                    tx(2)
                }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object represent the ESMC mode i.e. whether SSM is expected
        to be received on this interface or SSM are to be tranmissted on this
        interface.
        rx : SSM is expected to be received on this interface.
        tx : SSM is expected to be transmitted on this interface
        none : the SyncE interface doesn't support ESMC."
    DEFVAL  { 0 }
    ::= { fsSynceIfEntry 3 }

fsSynceIfPriority OBJECT-TYPE
    SYNTAX      Integer32 (0..255)
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object contains the priority value of an interface. It is used
        by the selection algorithm in order to select the best QL value
        among all the interfaces. In the disabled mode, the port QL value will
        not be a candidate QL for the selection of the best QL value i.e. SyncE
        feature will be non-operational on that particular interface.
        The default value of this object is undefined or disabled"
    DEFVAL { 0 }
    ::= { fsSynceIfEntry 4 }

fsSynceIfQLValue OBJECT-TYPE
    SYNTAX      INTEGER {
                            qlPRC(1),
                            qlSSUA(2),
                            qlSSUB(3),
                            qlSEC(4),
                            qlDNU(5),
                            qlPRS(6),
                            qlSTU(7),
                            qlST2(8),
                            qlTNC(9),
                            qlST3E(10),
                            qlST3(11),
                            qlSMC(12),
                            qlRES(13),
                            qlPROV(14),
                            qlDUS(15)
                        }
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object contains the QL value for a SyncE interface.
        The value of this object is not considered in QL disabled mode.
        The default value on this object is DNU(5)"
    DEFVAL { qlDNU }
    ::= { fsSynceIfEntry 5 }

fsSynceIfIsRxQLForced OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object will be true if operator manually assign the QL value to an
        interface."
    ::= { fsSynceIfEntry 6 }

fsSynceIfLockoutStatus OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object contains the lockout status for SyncE interface.
        Lockout temporarily removes a timing source as available synchronization
        source for the selection process.As defined in ITU-T G.781i, lockout
        commands are accepted for nominated synchronization sources
        (synchronization sources that are not disabled) of each selection process.
        By default Lockout status of an interface is disabled."
    DEFVAL  { false }
    ::= { fsSynceIfEntry 7 }

fsSynceIfSignalFail OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "If the hold off timer expires and no SyncE packet was received till
        then by the port then the status of the port changes to signal fail
        status. As defined in ITU-T standard G.781 Signal fail for a
        synchronization source is activated in case of defects detected in the
        server layers."
    ::= { fsSynceIfEntry 8 }

fsSynceIfPktsTx OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the total number of transmitted SyncE packets on
        an interface."
    ::= { fsSynceIfEntry 9 }

fsSynceIfPktsRx OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the total number of received SyncE packets on an
        interface."
    ::= { fsSynceIfEntry 10 }

fsSynceIfPktsRxDropped OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the total number of dropped SyncE packets on an
        interface."
    ::= { fsSynceIfEntry 11 }

fsSynceIfPktsRxErrored OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object contains the total number of SyncE packets whose
        processing(decoding) resulted into error."
    ::= { fsSynceIfEntry 12 }

fsSynceIfRowStatus OBJECT-TYPE
    SYNTAX      RowStatus
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "Used for creation/deletion of enteries in the SyncE interface table"
    ::= { fsSynceIfEntry 13 }