          -- Version  2.22.1.2, modified  2002-10-29 11:34:15-05

          CDX-6500-COMMON-MIB DEFINITIONS ::= BEGIN

          IMPORTS
                  mgmt, IpAddress, NetworkAddress, Counter, Gauge,
                          TimeTicks, OBJECT-TYPE, enterprises
                      FROM RFC1155-SMI;

               -- Codex MIB Group definitions

                         codex OBJECT IDENTIFIER ::= { enterprises 449 }
            cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 }
                       cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 }

               cdx6500NodeMgmt OBJECT IDENTIFIER ::= { cdx6500 1 }
            cdx6500NMSNMPGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 1 }
  cdx6500NMNodeParametersGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 2 }
     cdx6500NMDiagnosticsGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 3 }
        cdx6500NMControlsGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 4 }
            cdx6500NMDLSVGroup OBJECT IDENTIFIER ::= { cdx6500NodeMgmt 5 }

         cdx6500Configuration  OBJECT IDENTIFIER ::= { cdx6500 2 }
       cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 }
   cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 }
        cdx6500CfgGeneralGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 2 }

             cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 }
      cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 }
    cdx6500StatOtherStatsGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 2 }
          cdx6500StatTFTPGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 3 }
   cdx6500StatNetworkSvcsGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 4 }
   cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 }
cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 }
  cdx6500PSTLANConnectionGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 6 }

               cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 }
               cdx6500ContTFTP OBJECT IDENTIFIER ::= { cdx6500Controls 2 }
           cdx6500statControls OBJECT IDENTIFIER ::= { cdx6500Controls 4 }
              cdx6500ContFlash OBJECT IDENTIFIER ::= { cdx6500Controls 21 }

        -- Textual conventions
        Counter16     ::=  INTEGER (0..65535)

        DisplayString ::= OCTET STRING
        -- This data type is used to model textual information taken
        -- from the NVT ASCII character set.  By convention, objects
        -- with this syntax are declared as having SIZE (0..255)

        -- The purpose of this MIB file is to provide SNMP access to
        -- the Motorola/Codex 6500 database

        -- the SNMP Agent group
        -- This group acts as an extension of the MIB-II snmp group. It
        -- describes managed objects used by the Pegasus SNMP agent that
        -- are not included in the snmp group.

        cdx6500SNMPPrimUDPChan OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..3))
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "The primary UDP port used by the SNMP Agent
                 has a default value of 161."
        ::= { cdx6500NMSNMPGroup 1 }

        cdx6500SNMPSecUDPChan OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..3))
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "The secondary UDP port used by the SNMP Agent
                 has a default value of 162."
        ::= { cdx6500NMSNMPGroup 2 }

        cdx6500SNMPAgentTimer OBJECT-TYPE
            SYNTAX INTEGER (1..255)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "An internal timer used by the SNMP agent, unit
                 is a 20 ms tick."
        ::= { cdx6500NMSNMPGroup 3 }

        cdx6500SNMPTrapEnable OBJECT-TYPE
            SYNTAX INTEGER {
                    disable       (0),
                    enable        (1),
                    newvalDisable (50)
                    }
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "A control object to disable or enable the SNMP
                 agent's trap send capability.
                 newvalDisable : same functionality as 'disable', new
                 enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMSNMPGroup 4 }

        cdx6500SNMPBootAgent OBJECT-TYPE
            SYNTAX INTEGER {
                    boot   (1),
                    noBoot (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "A control object. Setting to value `boot' will cause
                 the SNMP agent to boot."
        ::= { cdx6500NMSNMPGroup 5 }

        cdx6500SNMPResetStats OBJECT-TYPE
            SYNTAX INTEGER {
                    reset   (1),
                    noReset (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "A control object, which when set to value `reset',
                 will cause the SNMP agent to reset all its statistics."
            ::= { cdx6500NMSNMPGroup 6 }

        cdx6500SNMPLastTrap OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..128))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The interesting information portion of the last trap
                 PDU issued by the SNMP Agent."
        ::= { cdx6500NMSNMPGroup 7 }

        cdx6500SNMPGenTrapsType OBJECT-TYPE
            SYNTAX INTEGER {
                    rfc                (1),
                    enterpriseSpecific (2)
                    }
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Choice between generic traps as defined in RFC or 
                 correponding enterprise specific traps to be generated
                 by the node. This attribute is applicable only when 
                 generic traps are being generated and there exists a 
                 corresponding enterprise specific trap."
        ::= { cdx6500NMSNMPGroup 8 }

        cdx6500SNMPTrapThrottleTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500SNMPTrapThrottleEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION 
                 "Throttling table."
        ::= { cdx6500NMSNMPGroup 9 }

        cdx6500SNMPTrapThrottleEntry OBJECT-TYPE
            SYNTAX Cdx6500SNMPTrapThrottleEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Entry representing throttling parameters."
            INDEX {cdx6500SNMPTrapNumber}
        ::= { cdx6500SNMPTrapThrottleTable 1 }

        Cdx6500SNMPTrapThrottleEntry ::= SEQUENCE {
            cdx6500SNMPTrapNumber        INTEGER,
            cdx6500SNMPMaxNumOfTraps     INTEGER,
            cdx6500SNMPThrottlingPeriod  INTEGER,
            cdx6500SNMPNewTrapLevel      INTEGER,
            cdx6500SNMPEntryStatus       INTEGER
		    }

        cdx6500SNMPTrapNumber  OBJECT-TYPE
            SYNTAX INTEGER(1000..2147483647)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "Trap number to be throttled."
	    ::= { cdx6500SNMPTrapThrottleEntry 1 }

        cdx6500SNMPMaxNumOfTraps  OBJECT-TYPE
            SYNTAX INTEGER(0..65535)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION "Number of traps allowed to be generated in the throttling period."
            DEFVAL {5}
        ::= { cdx6500SNMPTrapThrottleEntry 2 }

        cdx6500SNMPThrottlingPeriod  OBJECT-TYPE
            SYNTAX INTEGER(0..65535)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION "Throttling time period in seconds. Value 0 means trap is not throttled."
            DEFVAL {60}
        ::= { cdx6500SNMPTrapThrottleEntry 3 }

        cdx6500SNMPNewTrapLevel  OBJECT-TYPE
            SYNTAX INTEGER {unchanged(1), high (2), medium(3), low(5)}
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION "New severity level for the trap."
            DEFVAL {unchanged}
        ::= { cdx6500SNMPTrapThrottleEntry 4 }

        cdx6500SNMPEntryStatus  OBJECT-TYPE
            SYNTAX INTEGER {active(1), deleted(2)}
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION "Table row status. 
                         Setting the value to deleted removes the entry from the table."
            DEFVAL {active}
        ::= { cdx6500SNMPTrapThrottleEntry 5 }

        cdx6500SNMPSetControl OBJECT-TYPE
            SYNTAX INTEGER {
                    off       (1),
                    on        (2)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Snmp Set operation control      
			off : snmp set operation is not allowed
			on  : snmp set operation is allowed."
        ::= { cdx6500NMSNMPGroup 10 }

        cdx6500SNMPIpAddress OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "IP address for this node."
        ::= { cdx6500NMSNMPGroup 11 }

          -- The Node Parameters Group
          -- contains configuration, inventory, and statistics 
          -- on a node-wide basis.

        cdx6500NMNPconfig OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 1 }
        cdx6500NMNPinvent OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 2 }
        cdx6500NMNPstats  OBJECT IDENTIFIER ::= { cdx6500NMNodeParametersGroup 3 }

          -- Node Management Configuration Group

        cdx6500NMNPCnodeName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This parameter identifies the node with a name, which appears
                 at the top of control terminal menus and reports. Range is 0
                 to 8 alphanumeric characters."
        ::= { cdx6500NMNPconfig 1 }

        cdx6500NMNPCnodeNum OBJECT-TYPE
            SYNTAX INTEGER (0..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node number identifies the node for X.25 routing purposes
                 to prevent routing loops."
        ::= { cdx6500NMNPconfig 2 }

        cdx6500NMNPCnodeAddress OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..13))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node address specifies the main part of the network
                 address for calls destined within this node: PAD port or 
                 node resource (for example, control port) calls. Individual
                 subaddresses specify exact destination."
        ::= { cdx6500NMNPconfig 3 }

        cdx6500NMNPCchassis OBJECT-TYPE
            SYNTAX INTEGER {
                    standalone       (0),
                    modulus8         (1),
                    modulus18        (2),
                    modulus9         (3),
                    modulus19        (4),
                    chassis6520      (5),
                    chassis6560      (6),
                    newvalStandalone (50)
                    }
              ACCESS read-only
              STATUS mandatory
              DESCRIPTION
                  "This parameters identifies the type of chassis that this
                   node is residing in. This is necessary in order to correctly
                   interpret the fan and power supply status signals.
                   newvalStandalone : same functionality as 'standalone', new
                   enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMNPconfig 4 }

        cdx6500NMNPCdate OBJECT-TYPE
            SYNTAX DisplayString (SIZE(9))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node date used for date stamps of events and traps. The
                 format of the string is yyyymmmdd, year: four digits, month:
                 first three letters of the month, day: 01..31."
        ::= { cdx6500NMNPconfig 5 }

        cdx6500NMNPCtime OBJECT-TYPE
            SYNTAX DisplayString (SIZE(4))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The node time used for time stamps of events and traps. The
                 format of the string is hhmmss, hour: 00..23, minute 00..59,
                 second: 00..59."
        ::= { cdx6500NMNPconfig 6 }

        cdx6500NMNPCportUtil OBJECT-TYPE
            SYNTAX INTEGER (10..99)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Port Utilization Threshold (%). This parameter sets the alarm
                 level for traffic on every port in a node. The traffic is
                 checked over a 64-second interval to give an average (in
                 characters per second). This is compared to the port's clock
                 rate and a utilization factor is produced. If the percent of
                 utiliaztion exceeds the setting, an alarm is generated. Port
                 utilization records are kept for each port and the port in
                 question is noted in the report."
        ::= { cdx6500NMNPconfig 7 }

        cdx6500NMNPCbuffUtil OBJECT-TYPE
            SYNTAX INTEGER (10..99)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Buffer Utilization Threshold (%). This parameter sets the
                 alarm level for data buffers. When data passes through a node,
                 buffers provide temporary storage. If the number of buffers
                 used exceeds the specified percentage of available storage, an
                 alarm is generated."
        ::= { cdx6500NMNPconfig 8 }

        cdx6500NMNPCcpuUtil OBJECT-TYPE
            SYNTAX INTEGER (10..99)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "CPU Utilization Threshold (%). If the CPU is not processing
                 data, it is running diagnostic checks. It is never idle. This
                 parameter specifies the amount of time spent performing
                 non-diagnostic functions as a percentage of the total time. If
                 this percentage exceeds the threshold, an alarm is generated."
        ::= { cdx6500NMNPconfig 9 }

        cdx6500NMNPCportErr OBJECT-TYPE
            SYNTAX INTEGER (1..255)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Port Error Threshold. This threshold specifies the number of
                 port errors (such as parity or framing errors) that can be
                 detected before a medium severity alarm is generated. For
                 example, if this parameter is set to 10, an alarm is sent when
                 10 errors are detected, another alarm is sent when the 20th
                 error is detected, etc."
        ::= { cdx6500NMNPconfig 10 }

        cdx6500NMNPCalarmTmr OBJECT-TYPE
            SYNTAX INTEGER (15..255)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Alarm Threshold Timer. This parameter prevents a node from
                 sending threshold alarms too frequently. If a node generates
                 an alarm the threshold alarm timer is started and the node is
                 not allowed to generate the same alarm until the timer has
                 expired. This controls the frequency of alarm reporting."
        ::= { cdx6500NMNPconfig 11 }

        cdx6500NMNPCmaxRoutHops OBJECT-TYPE
            SYNTAX INTEGER (2..15)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Maximum Routing Hops.This parameter specifies the maximum
                 number of nodes a call may pass through before reaching 
                 its destination."
        ::= { cdx6500NMNPconfig 12 }

        cdx6500NMNPCctpSubAddr OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..3))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This parameter specifies the Control Port (CTP) Subaddress.
                 Calls with network address composed of the node address and
                 this subaddress will be routed to the control port in this
                 node. No routing table entry is needed."
        ::= { cdx6500NMNPconfig 13 }

        cdx6500NMNPCctpIdleTime OBJECT-TYPE
            SYNTAX INTEGER (1..255)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Control Port Idle Disconnect Time (minutes). This specifies
                 how many minutes of inactivity can occur before
                 the control terminal is automatically disconnected"
        ::= { cdx6500NMNPconfig 14 }

        cdx6500NMNPCalmDist OBJECT-TYPE
            SYNTAX INTEGER {
                    deprecatedObj (1)
                    }
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "This object has been replaced by cdx6500NMNPCalmDistrib."
        ::= { cdx6500NMNPconfig 15 }

        cdx6500NMNPCalmMmem OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Alarm Printer Mnemonic. This specifies the mnemonic name for
                 the destination of alarms sent by the node (if Alarm
                 Distribution = PRIN). This destination is usually a printer or
                 a personal computer. To prevent any alarms from being sent,
                 set this to blank."
        ::= { cdx6500NMNPconfig 16 }

        cdx6500NMNPCalmSelect OBJECT-TYPE
            SYNTAX INTEGER {
                    deprecatedObj (1)
                    }
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "This object has been replaced by cdx6500NMNPCalmSelection."
        ::= { cdx6500NMNPconfig 17 }

        cdx6500NMNPCbroadPortSubad OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..3))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This specifies the broadcast port subaddress for this node.
                 Calls with network address composed of the node address and
                 this subaddress will be routed to the broadcast port in this
                 node. No routing table entry is needed."
        ::= { cdx6500NMNPconfig 18 }

        cdx6500NMNPCnoBroadNets OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Broadcast Nets. This specifies the number of
                 Broadcast Networks to which this node can send
                 broadcast messages. A value of 0 will disable broadcast
                 functions."
        ::= { cdx6500NMNPconfig 19 }

        cdx6500NMNPCnoBroadInCh OBJECT-TYPE
            SYNTAX INTEGER (0..10)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Broadcast Input Channels.  This specifies
                 the number of simultaneous broadcast messages that can
                 be received."
        ::= { cdx6500NMNPconfig 20 }

        cdx6500NMNPCbillMnem OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "When billing records need to be printed, the node will use 
                 this mnemonic to call and send the records to this 
                 destination.  This location is usually a printer used to 
                 print billing records."
        ::= { cdx6500NMNPconfig 21 }

        cdx6500NMNPCbillThresh OBJECT-TYPE
            SYNTAX INTEGER (1..99)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "When the number of billing records queued up equals this
                 threshold, a call will be placed to the logging device to 
                 dump the billing records."
        ::= { cdx6500NMNPconfig 22 }

        cdx6500NMNPCmaxBill OBJECT-TYPE
            SYNTAX INTEGER (0..200)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the maximum number of billing records the node will
                 be allowed to store to be printed. Billing records created 
                 after this maximum is reached will be lost."
        ::= { cdx6500NMNPconfig 23 }

        cdx6500NMNPCbillTimer OBJECT-TYPE
            SYNTAX INTEGER (0..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "If billing records have been stored for printing for this 
                 amount of time (in minutes) without reaching the threshold,
                 a call will be made so that they can be printed."
        ::= { cdx6500NMNPconfig 24 }

        cdx6500NMNPCpvcBill OBJECT-TYPE
            SYNTAX INTEGER (0..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "At this interval the billing records will be gathered 
                 and printed for all of the PVC's in the node that have 
                 billing turned on."
        ::= { cdx6500NMNPconfig 25 }

        cdx6500NMNPCmaxCalls OBJECT-TYPE
            SYNTAX INTEGER (1..2000)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Limiting the number of calls allowed in the node will
                 eliminate data loss in extreme traffic conditions."
        ::= { cdx6500NMNPconfig 26 }

        cdx6500NMNPCpadBulletin OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "PAD Bulletin Message. Specifies the message that
                 appears when a terminal connects to PAD port and enters
                 Command Mode. To have no message appear, select blank."
        ::= { cdx6500NMNPconfig 27 }

        cdx6500NMNPCpadBanner OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..63))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "PAD Banner Message. Specifies the message PAD ports
                 send to attached terminals when they enter Command Mode.
                 These special characters can be used to display certain
                 information in the PAD Banner Message.
                 A               Node address
                 C               Channel Number
                 G               Group sub-address
                 N               Node Name
                 P               Port Number
                 S               Sub-address
                 T               Time
                 V               Software revision
                 If the character following the % symbol is not one of
                 the above, both the % and following character are
                 discarded. The caret (^) is used as an escape character
                 to tell the PAD to send control characters. The
                 character following the caret is converted to a control
                 character and is sent to the PAD port for output. The
                 caret is discarded unless it is entered twice (^^)."
        ::= { cdx6500NMNPconfig 28 }

        cdx6500NMNPCdcpFac OBJECT-TYPE
            SYNTAX INTEGER (201..254)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This defines the facility used to carry DCP information 
                 at call setup and reconnection time in Call Request and 
                 Call Accept packets through the 6500 network. Change the
                 value only if it interferes with some other private network
                 facility."
        ::= { cdx6500NMNPconfig 29 }

        cdx6500NMNPCtrafficPri OBJECT-TYPE
            SYNTAX INTEGER {
                    low       (0),
                    med       (1),
                    high      (2),
                    exp       (3),
                    newvalLow (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Traffic Priority. This is the default traffic
                 priority to be used on the node.
                 newvalLow : same functionality as 'low', new
                 enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMNPconfig 30 }

        cdx6500NMNPCtrafficStep OBJECT-TYPE
            SYNTAX INTEGER (1..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Traffic Priority Step. This specifies the
                 number of packets to be transmitted for each
                 lower priority packet transmitted."
        ::= { cdx6500NMNPconfig 31 }

        cdx6500NMNPCpropProtId OBJECT-TYPE
            SYNTAX INTEGER (192..255)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the Codex Proprietary Protocol ID. Its
                 value is put in the first byte of the Protocol
                 Identifier field of the CUD in the Call Request 
                 packets for protocols that have not been assigned
                 a standardized value by the CCITT."
        ::= { cdx6500NMNPconfig 32 }

        cdx6500NMNPClanSubAddr OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..3))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Calls with network address composed of the node
                 address and this subaddress will be routed to a
                 LAN Connection in this node."
        ::= { cdx6500NMNPconfig 33 }

        cdx6500NMNPCMaxFrameSize OBJECT-TYPE
            SYNTAX INTEGER (1..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The largest datalink level frame that will ever
                 be received on any link. On WAN links this does
                 not include space that is reserved internally
                 for trailers."
        ::= { cdx6500NMNPconfig 34 }

        cdx6500NMNPCCodexGroupFacility OBJECT-TYPE
            SYNTAX INTEGER (202..254)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the facility used in call packets on
                 Codex 6500 links for passing CODEX PRIVATE
                 facilities other than Hop Count and DCP
                 facilities between 4.xx nodes. This should
                 be the SAME on all nodes in the network. It
                 need only be changed if it interferes with
                 some other private network facility."
--          DEFVAL { 202 }
        ::= { cdx6500NMNPconfig 35 }

        cdx6500NMNPCalmDistrib OBJECT-TYPE
            SYNTAX DisplayString (SIZE(3..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Distribution of alarms is controlled by specifying:
                 NONE - no alarm is sent\r\n\
                 CTP  - send alarms to Control Port Terminal\r\n\
                 PRIN - send alarms to Printer Destination\r\n\
                 Any combination of above specified by summing (e.g. CTP+PRIN)."
        ::= { cdx6500NMNPconfig 36 }

        cdx6500NMNPCalmSelection OBJECT-TYPE
            SYNTAX DisplayString (SIZE(3..27))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Alarm type reporting by the node:
                 NONE - no alarms reported.
                 HIGH - high severity alarms reported.
                 MED  - medium severity alarms reported.
                 LOW  - low severity alarms reported.
                 CONN - connection events reported.
                 CODE - alarms from Codex 6000 communication processors
                        reported.
                 Any combination of above specified by summing 
                 (e.g. HIGH+CONN+. . .)."
        ::= { cdx6500NMNPconfig 37 }

        cdx6500NMNPChopFacility OBJECT-TYPE
            SYNTAX INTEGER (200..254)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Hop Count Facility. This is the facility used in call
                 packets on X.25 links with the INL option for network
                 routing. This should be the SAME in all nodes in the network.
                 It need only be changed if it interferes with some other
                 private network facility."
        ::= { cdx6500NMNPconfig 38 }

        cdx6500NMNPCnumNccpDevices OBJECT-TYPE
            SYNTAX INTEGER (1..2000)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the number of NCCP devices."
        ::= { cdx6500NMNPconfig 39 }

        cdx6500NMNPCmaxCallid OBJECT-TYPE
            SYNTAX INTEGER (0..200)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the maximum number of Call id numbers that go in the
                 Calling Identifier table. This table can have a maximum of 512
                 entries. Each entry of 30 digits."
        ::= { cdx6500NMNPconfig 40 }

         -- Node Inventory Group

        cdx6500NMNPIproductType OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Identifies a general class of feature set for
                 the product, e.g. 6504PLUS Asynchronous PAD
                 or 6520 Branch Node"
        ::= { cdx6500NMNPinvent 1 }

        cdx6500NMNPIsoftwareSrc OBJECT-TYPE
            SYNTAX INTEGER {
                    prom           (0),
                    download       (1),
                    promLoadingRAM (2),
                    newvalProm     (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The source of software currently running on the node.
                 prom           - CPU running from code in PROM.
                 download       - CPU downloading code into RAM.
                 promLoadingRAM - CPU running from code in RAM.
                 newvalProm     - same functionality as 'prom', new
                                  enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMNPinvent 2 }

        cdx6500NMNPIserialNum OBJECT-TYPE
            SYNTAX INTEGER 
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The serial number of the motherboard."
        ::= { cdx6500NMNPinvent 3 }

        cdx6500NMNPIpromRevision OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The PROM software revision."
        ::= { cdx6500NMNPinvent 4 }

        cdx6500NMNPIdlCodeRevision OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The downloaded software revision. Applicable to
                 6500 platforms."
        ::= { cdx6500NMNPinvent 5 }

        cdx6500NMNPIdlCodeSource OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The source of downloaded software. Applicable
                 to 6500 platforms."
        ::= { cdx6500NMNPinvent 6 }

        cdx6500NMNPIdlCodeSize OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The size of downloaded software in bytes.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPinvent 7 }


        cdx6500NMNPIflashStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    enabled       (0),
                    disabled      (1),
                    newvalEnabled (50)
                    }
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The status of use of flash memory. Applicable
                 only to 6500 platforms.
                 newvalEnabled : same functionality as 'enabled', new
                 enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMNPinvent 8 }

        cdx6500NMNPIflashIdCur OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Name and version of software stored in flash.
                 This refers to the currently selected bank
                 of flash when there is an alternate bank of
                 flash installed."
        ::= { cdx6500NMNPinvent 9 }

        cdx6500NMNPIflashIdAlt OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Name and version of software contained by the
                 alternate bank of flash (if installed).
                 Applicable to 6520 platforms."
        ::= { cdx6500NMNPinvent 10 }

        cdx6500NMNPIflashSizeCur OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Size of software stored in flash. This refers
                 to the currently selected bank of flash when
                 there is an alternate bank of flash installed."
        ::= { cdx6500NMNPinvent 11 }

        cdx6500NMNPIflashSizeAlt OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Size of software in the alternate bank of flash
                 (bytes). Applicable to 6520 platforms."
        ::= { cdx6500NMNPinvent 12 }

        cdx6500NMNPIinventTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500NMNPIinventEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of the node's boards."
        ::= { cdx6500NMNPinvent 13 }

        cdx6500NMNPIinventEntry OBJECT-TYPE
            SYNTAX Cdx6500NMNPIinventEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each entry contains a board number, board type, number of
                 ports, status, and serial number."
            INDEX { cdx6500NMNPIinventBoard }
        ::= { cdx6500NMNPIinventTable 1}

        Cdx6500NMNPIinventEntry ::=
            SEQUENCE {
                cdx6500NMNPIinventBoard
                    INTEGER,
                cdx6500NMNPIinventType
                    DisplayString,
                cdx6500NMNPIinventPorts
                    INTEGER,
                cdx6500NMNPIinventStatus
                    DisplayString,
                cdx6500NMNPIinventSerial
                    DisplayString,
                cdx6500NMNPIinventAssy 
                    DisplayString,
                cdx6500NMNPIinventRev 
                    DisplayString,
                cdx6500NMNPIinventDIM1
                    DisplayString,
                cdx6500NMNPIinventDIM2
                    DisplayString
                }

        cdx6500NMNPIinventBoard OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The board number. This is used to index the boards in a node."
        ::= { cdx6500NMNPIinventEntry 1 }

        cdx6500NMNPIinventType OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The board type. A description of the type of board."
        ::= { cdx6500NMNPIinventEntry 2 }

        cdx6500NMNPIinventPorts OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of I/O ports for this board."
        ::= { cdx6500NMNPIinventEntry 3 }

        cdx6500NMNPIinventStatus OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The status of the board"
        ::= { cdx6500NMNPIinventEntry 4 }

        cdx6500NMNPIinventSerial OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The serial number of the board"
        ::= { cdx6500NMNPIinventEntry 5 }

        cdx6500NMNPIinventAssy OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The assembly number of the board"
        ::= { cdx6500NMNPIinventEntry 6 }

        cdx6500NMNPIinventRev OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The revision level of the board"
        ::= { cdx6500NMNPIinventEntry 7 }

        cdx6500NMNPIinventDIM1 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The type of interface specified by DIM 1."
        ::= { cdx6500NMNPIinventEntry 8 }

        cdx6500NMNPIinventDIM2 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The type of interface specified by DIM 2."
        ::= { cdx6500NMNPIinventEntry 9 }


        cdx6500NMNPIinventPortConfigTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500NMNPIinventPortConfigEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of the node's Port Configuration."
        ::= { cdx6500NMNPinvent 14 }

        cdx6500NMNPIinventPortConfigEntry OBJECT-TYPE
            SYNTAX Cdx6500NMNPIinventPortConfigEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each entry contains a port configuration."
            INDEX { cdx6500NMNPIinventPortNum }
        ::= { cdx6500NMNPIinventPortConfigTable 1}

        Cdx6500NMNPIinventPortConfigEntry ::=
            SEQUENCE {
                cdx6500NMNPIinventPortNum
                    INTEGER,
                cdx6500NMNPIinventPortConfig
                    DisplayString
                }

        cdx6500NMNPIinventPortNum OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port  number. This is used to index the ports in a node."
        ::= { cdx6500NMNPIinventPortConfigEntry 1 }

        cdx6500NMNPIinventPortConfig OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port configuration on each board."
        ::= { cdx6500NMNPIinventPortConfigEntry 2 }

        -- Node Management Statistics Group

        cdx6500NMNPSevLastOccPower OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last time the node was turned on."
        ::= { cdx6500NMNPstats 1 }

        cdx6500NMNPSevLastOccReset OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last time the reset button was pressed."
        ::= { cdx6500NMNPstats 2 }
 
        cdx6500NMNPSevLastOccReboot OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last time the node was rebooted."
        ::= { cdx6500NMNPstats 3 }

        cdx6500NMNPSevLastOccWDTimer OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last time the watch dog timer expired."
        ::= { cdx6500NMNPstats 4 }

        cdx6500NMNPSevLastOccConfig OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The last time the configuration memory was changed or
                 downloaded."
        ::= { cdx6500NMNPstats 5 }

        cdx6500NMNPSstatusFan OBJECT-TYPE
            SYNTAX INTEGER {
                    notMonitored       (0),
                    operational        (1),
                    impaired           (2),
                    newvalNotMonitored (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The operational status of the cooling fan.
                 newvalNotMonitored : same functionality as
                 'notMonitored', new enumeration added for 
                 RFC1155 compatibility."
        ::= { cdx6500NMNPstats 6 }

        cdx6500NMNPSstatusPwrSy OBJECT-TYPE
            SYNTAX INTEGER {
                    notMonitored       (0),
                    operational        (1),
                    impaired           (2),
                    newvalNotMonitored (50),
                    notAvailable       (100)
                    }
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "The operational status of the power supply.
                 This object is being replaced by cdx6500NMNPSstatusPowerSy.
                 newvalNotMonitored : same functionality as 'notMonitored',
                 new enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMNPstats 7 }


        cdx6500NMNPScmemSizeComp OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Size of compressed configuration memory available (free) in
                 bytes."
        ::= { cdx6500NMNPstats 8 }

        cdx6500NMNPScmemUseComp OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Size of compressed configuration memory in use in bytes."
        ::= { cdx6500NMNPstats 9 }

        cdx6500NMNPScmemSizeUncomp OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Size of uncompressed configuration memory available (free) in
                 bytes."
        ::= { cdx6500NMNPstats 10 }

        cdx6500NMNPScmemUseUnComp OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Size of uncompressed configuration memory in use in bytes."
        ::= { cdx6500NMNPstats 11 }

        cdx6500NMNPScallsInPlaceCur OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of X.25 calls.  The number of calls currently in
                 place."
        ::= { cdx6500NMNPstats 12 }

        cdx6500NMNPScallsInPlaceMax OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of X.25 calls gauge. The maximum number of calls since
                 the last reset."
        ::= { cdx6500NMNPstats 13 }

        cdx6500NMNPScallsPerSecCur OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Rate of X.25 calls. The number of calls/sec. currently
                 in place."
        ::= { cdx6500NMNPstats 14 }

        cdx6500NMNPScallsPerSecMax OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Rate of X.25 calls gauge. The maximum number of calls/sec.
                 since the last reset."
        ::= { cdx6500NMNPstats 15 }

        cdx6500NMNPSpvcConnectCur OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Permanent virtual circuit connections. The number currently
                 in place."
        ::= { cdx6500NMNPstats 16 }

        cdx6500NMNPSPVCConnectMax OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Permanent virtual circuit connections. The maximum since the
                 last reset."
        ::= { cdx6500NMNPstats 17 }

        cdx6500NMNPSbuffDataAvail OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of data buffers available.
                 Applicable to all platforms."
        ::= { cdx6500NMNPstats 18 }

        cdx6500NMNPSbuffDataUse OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of data buffers in use.
                 Applicable to all platforms."
        ::= { cdx6500NMNPstats 19 }

        cdx6500NMNPSbuffDataGauge OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The maximum number of data buffers in use since last reset
                 Applicable to all platforms."
        ::= { cdx6500NMNPstats 20 }

        cdx6500NMNPSbuffPacketAvail OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of packet buffers available. Applicable to all 
                 platforms except VG100 ."
        ::= { cdx6500NMNPstats 21 }

        cdx6500NMNPSbuffPacketUse OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of packet buffers in use. Applicable to all 
                 platforms except VG100."
        ::= { cdx6500NMNPstats 22 }

        cdx6500NMNPSbuffPacketExhaust OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of times the packet buffer pool has been 
                 exhausted since last reset. Applicable to all platforms 
                 except VG100."
        ::= { cdx6500NMNPstats 23 }

        cdx6500NMNPSbuffMgtAvail OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of management buffers available. Applicable to 
                 all platforms except VG100."
        ::= { cdx6500NMNPstats 24 }

        cdx6500NMNPSbuffMgtUse OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of management buffers in use. Applicable to all 
                 platforms except VG100."
        ::= { cdx6500NMNPstats 25 }

        cdx6500NMNPSbuffMgtExhaust OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of times the management buffer pool has been 
                 exhausted since last reset. Applicable to all platforms 
                 except VG100."
        ::= { cdx6500NMNPstats 26 }

        cdx6500NMNPSrateCurChar OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Node throughput, number of current chararacters/second 
                 for the node."
        ::= { cdx6500NMNPstats 27 }

        cdx6500NMNPSrateCurPkt OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Node throughput, number of current packets/second 
                 for the node."
        ::= { cdx6500NMNPstats 28 }

        cdx6500NMNPSrateMaxChar OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Node throughput gauge, Number of maximum characters/second for
                 the node since last reset"
        ::= { cdx6500NMNPstats 29 }

        cdx6500NMNPSrateMaxPkt OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Node throughput gauge, Number of maximum packets/second for
                 the node since last reset"
        ::= { cdx6500NMNPstats 30 }

        cdx6500NMNPSmemEprom OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Amount of memory available on the processor card in bytes.
                 Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 31 }

        cdx6500NMNPSmemDram OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Amount of memory used for data buffers in bytes.
                 Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 32 }

        cdx6500NMNPSmemFlashCur OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The size of the flash module in bytes. This refers to the
                 currently selected bank of flash when there is an alternate
                 bank of flash installed. Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 33 }

        cdx6500NMNPSmemFlashAlt OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The size of the alternate flash module in bytes. Applicable
                 to 6520 platforms."
        ::= { cdx6500NMNPstats 34 }

        cdx6500NMNPScpuUtil OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Percentage of time the CPU processed traffic data (as
                 opposed performing diagnositic tests or processing node
                 control data) to in the last 64 seconds.
                 Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 35 }

        cdx6500NMNPSDisplayNumImage OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Front panel numeric display. Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 36 }

        cdx6500NMNPSDisplayLEDstatus OBJECT-TYPE
            SYNTAX INTEGER {
                    off          (0),
                    on           (1),
                    blinking     (2),
                    newvalOff    (50),
                    notSupported (100)
                    }
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Front panel status LED. Applicable to 6520 platforms.
                 newvalOff : same functionality as 'off', new enumeration
                 added for RFC1155 compatibility."
        ::= { cdx6500NMNPstats 37 }

        cdx6500NMNPSDisplayLEDdiag OBJECT-TYPE
            SYNTAX INTEGER {
                    off          (0),
                    on           (1),
                    blinking     (2),
                    newvalOff    (50),
                    notSupported (100)
                    }
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Front panel fault (or service) LED. Applicable to 6520
                 platforms.
                 newvalOff : same functionality as 'off', new enumeration
                 added for RFC1155 compatibility."
        ::= { cdx6500NMNPstats 38 }

        cdx6500NMNPSdefaultNode OBJECT-TYPE
            SYNTAX INTEGER {
                    default   (1),
                    noDefault (2)
                    }
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A control object. Setting to value default will cause the
                 current configuration of the entire node to change back to the
                 default settings. CAUTION: If you implement the Default Node
                 control, communications are disrupted and data could be lost
                 after a boot. In addition, configuration settings are lost
                 unless they had been saved to an external device."
        ::= { cdx6500NMNPstats 39 }

        cdx6500NMNPSresetStatTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500NMNPSresetStatEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of Port Statistic Reset entries."
        ::= { cdx6500NMNPstats 40 }

        cdx6500NMNPSresetStatAll OBJECT-TYPE
            SYNTAX INTEGER {
                    reset   (1),
                    noReset (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "A value of reset will cause statistics to be reset on all
                 ports. A value of noReset has no effect."
        ::= { cdx6500NMNPstats 41 }

        cdx6500NMNPSstatusPowerSy OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..20))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The operational status of the power supply.
                 This object replaces cdx6500NMNPSstatusPwrSy."
        ::= { cdx6500NMNPstats 42 }

        cdx6500NMNPSresetStatEntry OBJECT-TYPE
            SYNTAX Cdx6500NMNPSresetStatEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each entry contains a port number and a control to reset
                 statistics for that port."
            INDEX { cdx6500NMNPSresetStatPort }
        ::= { cdx6500NMNPSresetStatTable 1 }

        Cdx6500NMNPSresetStatEntry ::=
            SEQUENCE {
                cdx6500NMNPSresetStatPort
                    INTEGER,
                cdx6500NMNPSresetStatStatus
                    INTEGER
                }

        cdx6500NMNPSresetStatPort OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "The port number value for this object directs the
                 statistics reset command to that port."
        ::= { cdx6500NMNPSresetStatEntry 1 }


        cdx6500NMNPSresetStatStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    reset   (1),
                    noReset (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "A value of reset will cause a port's statistics to be reset.
                 A value of noReset has no effect."
        ::= { cdx6500NMNPSresetStatEntry 2 }


        cdx6500NMNPSstatsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500NMNPSstatsEntry
            ACCESS not-accessible
            STATUS optional
            DESCRIPTION
                "Board specific statistics. Applicable to 6500 platforms."
        ::= { cdx6500NMNPstats 43 }

        cdx6500NMNPSstatsEntry OBJECT-TYPE
            SYNTAX Cdx6500NMNPSstatsEntry
            ACCESS not-accessible
            STATUS optional
            DESCRIPTION
                "A Board statistics Table entry. Each entry
                 contains statistics parameters for a single board.
                 Applicable to 6500 platforms."
            INDEX { cdx6500NMNPSstatsBoard }
        ::= { cdx6500NMNPSstatsTable 1 }

        Cdx6500NMNPSstatsEntry ::=
            SEQUENCE{
                cdx6500NMNPSstatsBoard
                    INTEGER,
                cdx6500NMNPSstatsbuffDataAvail
                    INTEGER,
                cdx6500NMNPSstatsbuffDataUse
                    INTEGER,
                cdx6500NMNPSstatsbuffDataGauge
                    Gauge,
                cdx6500NMNPSstatsmemEprom
                    INTEGER,
                cdx6500NMNPSstatsmemDram
                    INTEGER,
                cdx6500NMNPSstatsmemFlash
                    INTEGER,
                cdx6500NMNPSstatscpuUtil
                    INTEGER,
                cdx6500NMNPSstatsMaxcpuUtil
                    INTEGER,
                cdx6500NMNPSstatsMaxcpuUtilTime
                    DisplayString
             }

        cdx6500NMNPSstatsBoard OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Board number. Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 1 }

        cdx6500NMNPSstatsbuffDataAvail OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of data buffers available.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 2 }

        cdx6500NMNPSstatsbuffDataUse OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The number of data buffers in use.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 3 }

        cdx6500NMNPSstatsbuffDataGauge OBJECT-TYPE
            SYNTAX Gauge
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The maximum number of data buffers in use since last reset
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 4 }

        cdx6500NMNPSstatsmemEprom OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Amount of memory available on the processor card in bytes.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 5 }

        cdx6500NMNPSstatsmemDram OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Amount of memory used for data buffers in bytes.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 6 }

        cdx6500NMNPSstatsmemFlash OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The size of the flash module in bytes. This refers to the
                 currently selected bank of flash when there is an alternate
                 bank of flash installed. Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 7 }

        cdx6500NMNPSstatscpuUtil OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Percentage of time the CPU processed traffic data (as
                 opposed performing diagnositic tests or processing node
                 control data) to in the last 64 seconds.
                 Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 8 }

        cdx6500NMNPSstatsMaxcpuUtil OBJECT-TYPE
            SYNTAX INTEGER 
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Peak CPU Utilization since last node or statistics 
                 reset. Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 9 }

        cdx6500NMNPSstatsMaxcpuUtilTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Time stamp of Peak CPU Utilization since last node or
                 statistics reset. Applicable to 6500 platforms."
        ::= { cdx6500NMNPSstatsEntry 10 }

        cdx6500NMNPScallsInPlaceMaxTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time stamp of Max number of calls since the last
                 reset."
        ::= { cdx6500NMNPstats 44 }

        cdx6500NMNPSPVCConnectMaxTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time stamp of Max number of PVC connections since the 
                 last reset."
        ::= { cdx6500NMNPstats 45 }

        cdx6500NMNPScallsPerSecMaxTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time stamp of Max number of calls/sec since the last
                 reset."
        ::= { cdx6500NMNPstats 46 }

        cdx6500NMNPSbuffDataGaugeTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Time stamp of Max number of data buffers in use since
                 the last reset. Applicable to all platforms."
        ::= { cdx6500NMNPstats 47 }

        cdx6500NMNPSbuffPacketGauge OBJECT-TYPE
            SYNTAX Gauge 
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The maximum number of packet buffers in use since the
                 last reset. Applicable to all platforms except VG100."
        ::= { cdx6500NMNPstats 48 }

        cdx6500NMNPSbuffPacketGaugeTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Time stamp of Max number of packet buffers in use since
                 the last reset. Applicable to all platforms except 
                 VG100."
        ::= { cdx6500NMNPstats 49 }

        cdx6500NMNPSbuffMgtGauge OBJECT-TYPE
            SYNTAX Gauge 
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "The maximum number of management buffers in use since 
                 the last reset. Applicable to all platforms except
                 VG100."
        ::= { cdx6500NMNPstats 50 }

        cdx6500NMNPSbuffMgtGaugeTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Time stamp of Max number of management buffers in use 
                 since the last reset. Applicable to all platforms 
                 except VG100."
        ::= { cdx6500NMNPstats 51 }

        cdx6500NMNPSrateMaxCharTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time stamp of Max node throughput (chars/sec) since the
                 last reset."
        ::= { cdx6500NMNPstats 52 }

        cdx6500NMNPSrateMaxPktTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time stamp of Max node throughput (packets/sec) since
                 the last reset."
        ::= { cdx6500NMNPstats 53 }

        cdx6500NMNPSMaxcpuUtil OBJECT-TYPE
            SYNTAX INTEGER 
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Peak CPU Utilization since last node or statistics 
                 reset. Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 54 }

        cdx6500NMNPSMaxcpuUtilTime OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS optional
            DESCRIPTION
                "Time stamp of Peak CPU Utilization since last node or
                 statistics reset. Applicable to 6520 platforms."
        ::= { cdx6500NMNPstats 55 }


        -- The Report Statistics Table
        -- This table contains statistics paramaters 
        -- for the Report Operator event log table.

        cdx6500NMReportTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500NMReportEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "All of the statistics parameters relevant
                 to the Report event log table."
        ::= { cdx6500NMDiagnosticsGroup 1 }

        cdx6500NMReportEntry OBJECT-TYPE
            SYNTAX Cdx6500NMReportEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A row of Report Statistics parameters."
            INDEX { cdx6500reptIndex }
        ::= { cdx6500NMReportTable 1 }

        Cdx6500NMReportEntry ::=
            SEQUENCE {
                cdx6500reptIndex
                    INTEGER,
                cdx6500reptEvent
                    DisplayString
                }
    
        cdx6500reptIndex OBJECT-TYPE
            SYNTAX INTEGER (1..512)
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Report Log Index"
        ::= { cdx6500NMReportEntry 1 }
    
        cdx6500reptEvent OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..152))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Report Log Alarm Text"
        ::= { cdx6500NMReportEntry 2 }
  
        cdx6500NMreptClearLog OBJECT-TYPE
            SYNTAX INTEGER {
                    clearLog   (1),
                    noClearLog (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Clears the Operator log.
                 clearLog   - Clear the Log
                 noClearLog - Do not clear the Log."
        ::= { cdx6500NMDiagnosticsGroup 2 }

        -- The V54 Loopback group, part of Pegasus Diagnostics
        -- This Group contains controls, configurables, and statistics 
        -- parameters related to invoking and monitoring loopback tests.

        cdx6500NMV54Loopback OBJECT IDENTIFIER ::= { cdx6500NMDiagnosticsGroup 3 }
        cdx6500NMV54LocalLoop OBJECT-TYPE
            SYNTAX INTEGER {
                    startTest (1),
                    noTest    (2)
                    }
            ACCESS write-only
            STATUS obsolete
            DESCRIPTION
                "Local loop test; The test will start when set to value
                 'startTest'."
        ::= { cdx6500NMV54Loopback 1 }

        cdx6500NMV54Loop2 OBJECT-TYPE
            SYNTAX INTEGER {
                    startTest (1),
                    noTest    (2)
                    }
            ACCESS write-only
            STATUS obsolete
            DESCRIPTION
                "Loopback test 2 : Loop at remote modem digital side."
        ::= { cdx6500NMV54Loopback 2 }

        cdx6500NMV54Loop3 OBJECT-TYPE
            SYNTAX INTEGER  {
                    startTest (1),
                    noTest    (2)
                    }
            ACCESS write-only
            STATUS obsolete
            DESCRIPTION
                "Loopback test 3: Loop at local modem analog side."
        ::= { cdx6500NMV54Loopback 3 }

        cdx6500NMV54turnLoopbackOff OBJECT-TYPE
            SYNTAX INTEGER   {
                    loopbackOff(1)
                    }
            ACCESS write-only
            STATUS obsolete
            DESCRIPTION
                "A control to turn any loopback test off"
        ::= { cdx6500NMV54Loopback 4 }

        cdx6500NMV54LoopbackDuration OBJECT-TYPE
            SYNTAX INTEGER (0..65535)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Duration of loopback in seconds."
        ::= { cdx6500NMV54Loopback 5 }

        cdx6500NMV54TestType OBJECT-TYPE
            SYNTAX INTEGER {
                    v54LocalLoop (1),
                    v54Loop2     (2),
                    v54Loop3     (3)
                    }
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Loopback test type."
        ::= { cdx6500NMV54Loopback 6 }

        cdx6500NMV54LoopbackStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    v54Starting           (1),
                    v54Running            (2),
                    v54Stopping           (3),
                    v54Clearing           (4),
                    v54Stopped            (5),
                    v54AbortPortDisabled  (6),
                    v54AbortIsRunning     (7),
                    v54AbortPortNull      (8),
                    v54AbortEiaDisc       (9),
                    v54AbortCpuNotRunning (10),
                    v54AbortNotSupported  (11),
                    v54AbortWrongParams   (12),
                    v54AbortWrongPort     (13),
                    v54NotRun             (14)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Loopback Status.
                 v54Starting - test is being prepared to start.
                 v54Running - test in progress.
                 v54Stopping - test is being stopped.
                 v54Clearing - system is clearing resources used for the test.
                 v54Stopped - test has been completed.
                 v54AbortPortDisabled - selected port is disabled.
                 v54AbortIsRunning - test is already running on the specified port.
                 v54AbortPortNull - selected port is of NULL type.
                 v54AbortEiaDisc - interface has been disconnected during the test.
                 v54AbortCpuNotRunning - CPU is not running on the specified port.
                 v54AbortNotSupported - specified test is not supported by the selected port.
                 v54AbortWrongParams - specified test params are incorrect. Check port number.
                 v54AbortWrongPort - specified port is incorrect.
                 v54NotRun - test has not been run yet."
        ::= { cdx6500NMV54Loopback 7 }

        cdx6500NMV54MessagesSent OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Number of messages sent"
        ::= { cdx6500NMV54Loopback 9}

        cdx6500NMV54GoodMsgsReceived OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Number of good messages received"
        ::= { cdx6500NMV54Loopback 10 }

        cdx6500NMV54BadMsgsReceived OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Number of bad messages received"
        ::= { cdx6500NMV54Loopback 11 }
                                
        cdx6500NMV54LastPortTested OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS read-only
            STATUS obsolete
            DESCRIPTION
                "Last port to be put in loopback."
        ::= { cdx6500NMV54Loopback 12 }

        cdx6500NMV54CurrentTestPort OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS read-write
            STATUS obsolete
            DESCRIPTION
                "Current test port."
        ::= { cdx6500NMV54Loopback 13 }

        cdx6500NMV54LoopbackTest OBJECT-TYPE
            SYNTAX INTEGER {testing (1), notTesting (2)}
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Starts and stops loopback test."
        ::= { cdx6500NMV54Loopback 14 }

        cdx6500NMV54LoopbackTestType OBJECT-TYPE
            SYNTAX INTEGER {
                    v54LocalLoop          (1),
                    v54Loop2              (2),
                    v54Loop3              (3),
                    dsuInternal           (4),
                    dsuInternalExternal   (5)
                    }
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Loopback test type.
                 v54LocalLoop - creates a loop on the selected port.
                 v54Loop2 - creates a loop on the remote modem digital side.
                 v54Loop3 - creates a loop on the local modem analog side.
                 dsuInternal - creates a loop on the internal interface.
                 dsuInternalExternal - creates a loop on the internal and the external interfaces."
        ::= { cdx6500NMV54Loopback 15 }

        cdx6500NMV54LoopbackLastPortTested OBJECT-TYPE
            SYNTAX INTEGER (0..54)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Last port put in loopback."
        ::= { cdx6500NMV54Loopback 16 }

        cdx6500NMV54LoopbackCurrentTestPort OBJECT-TYPE
            SYNTAX INTEGER (0..54)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Current test port. Value zero means that no port has been specified.
                When test completes, this object is defaulted to zero."
        ::= { cdx6500NMV54Loopback 17 }

        cdx6500NMV54LoopbackMessagesSent OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of messages sent"
        ::= { cdx6500NMV54Loopback 18}

        cdx6500NMV54LoopbackGoodMsgsReceived OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of good messages received"
        ::= { cdx6500NMV54Loopback 19}

        cdx6500NMV54LoopbackBadMsgsReceived OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of bad messages received"
        ::= { cdx6500NMV54Loopback 20}
 
        -- Node Management Controls Group

        cdx6500NMCBootNode OBJECT-TYPE
            SYNTAX INTEGER {
                    bootCold       (0),
                    bootWarm       (1),
                    newvalBootCold (50)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Setting this object will cuase the node to perform either
                 a cold or a warm Node boot :
                 bootCold - perform a cold Node Boot; run diagnostic
                            tests, reload operational software, request
                            software download if neccessary, reload
                            configuration and start the node.
                 bootWarm - perform a warm Node Boot; reload
                            configuration and start the node.
                 newvalBootCold - same functionality as 'bootCold', new
                            enumeration added for RFC1155 compatibility."
        ::= { cdx6500NMControlsGroup  1 }

        cdx6500NMCBootTableNodeRec OBJECT-TYPE
            SYNTAX INTEGER {
                    bootrec (1)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Setting to bootrec will cause the running configuration
                 to be updated using new configuration tables from CMEM."
        ::= { cdx6500NMControlsGroup 2 }

        -- DLSV Group
        cdx6500DLSVDLstate OBJECT-TYPE
            SYNTAX INTEGER {
                    dlStart (1),
                    dlCall  (2),
                    dlReq   (3),
                    dlLoad  (4),
                    dlGss   (8),
                    dlLgs   (16),
                    dlDone  (32),
                    dlBoot  (64),
                    dlIdle  (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Statistic - state of the download
                 dlStart : Setup phase.
                 dlCall  : Setup phase.
                 dlReq   : Setup phase.
                 dlLoad  : Downloading phase.
                 dlGss   : Setup phase.
                 dlLgs   : Downloading phase.
                 dlDone  : Download Complete.
                 dlBoot  : Download Complete.
                 dlIdle  : No download."
        ::= { cdx6500NMDLSVGroup 1 }

        cdx6500DLSVPercentComplete OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Statistic - amount of download that has completed."
        ::= { cdx6500NMDLSVGroup 2 }

        cdx6500DLSVTimestamp OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Statistic - time of last download."
        ::= { cdx6500NMDLSVGroup 3 }

        cdx6500DLSVLastServer OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Statistic - Last server node to send software."
        ::= { cdx6500NMDLSVGroup 4 }

        cdx6500DLSVTransferType OBJECT-TYPE
            SYNTAX INTEGER {
                   idle         (1),
                   ramToram     (2),
                   flashToflash (3)
                   } 
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Statistic - type of transfer - i.e. which bank to which
                 bank at what throughput."
        ::= { cdx6500NMDLSVGroup 5 }

        cdx6500DLSVInitiateTransfer OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Type of transfer - i.e. which bank to which bank at
                 what throughput setting this initiates the flash to
                 flash transfer."
        ::= { cdx6500NMDLSVGroup 6 }

        cdx6500DLSVAgntSegmentSize OBJECT-TYPE
            SYNTAX INTEGER {
                    segmentSizeDisable       (0),
                    segmentSize16            (4),
                    segmentSize32            (5),
                    segmentSize64            (6),
                    segmentSize128           (7),
                    segmentSize256           (8),
                    segmentSize512           (9),
                    segmentSize1024          (10),
                    newvalSegmentSizeDisable (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the segment size used for accounting purposes
                 with data packets. 
                 segmentSizeDisable - segment counting disabled.
                 segmentSize16      - 16   byte segments.
                 segmentSize32      - 32   byte segments.
                 segmentSize64      - 64   byte segments.
                 segmentSize128     - 128  byte segments.
                 segmentSize256     - 256  byte segments.
                 segmentSize512     - 512  byte segments.
                 segmentSize1024    - 1024 byte segments
                 newvalSegmentSizeDisable - same as 
                                      'segmentSizeDisable', new
                                      enumeration added for
                                      RFC1155 compatibility."
        ::= { cdx6500NMDLSVGroup 7 }

        cdx6500DLSVAgntnmServAddress OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the mnemonic name of the download server
                 assigned to load this node with operational
                 software."
        ::= { cdx6500NMDLSVGroup 8 }

        cdx6500DLSVagntloaderSubaddress OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the subaddress of the download module in this
                 node."
        ::= { cdx6500NMDLSVGroup 9 }

        cdx6500DLSVagntdlServSubaddress OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Calls with network address composed of the node address
                 (configured in the Node record) and this subaddress will
                 be routed to the module in this node which sends code to
                 a remote node. No routing table entry is needed."
        ::= { cdx6500NMDLSVGroup 10 }

        -- The Statistics Tables
        -- The allPorts Statistics Table
        -- This table contains statistic parameters 
        -- for the allPorts table.
  
  
        cdx6500PPSTallPortsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500PPSTallPortsEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "All of the statistics parameters relevant
                 to the allPorts table."
        ::= { cdx6500PSTPortProtocolGroup 18 }
  
        cdx6500PPSTallPortsEntry OBJECT-TYPE
            SYNTAX Cdx6500PPSTallPortsEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A row of allPorts statistics parameters."
            INDEX { cdx6500allportsPortNum }
        ::= { cdx6500PPSTallPortsTable 1 }
  
        Cdx6500PPSTallPortsEntry ::=
            SEQUENCE {
                cdx6500allportsPortNum
                    INTEGER,
                cdx6500allportsPortType
                    INTEGER,
                cdx6500allportsPortStatus
                    INTEGER,
                cdx6500allportsPortState
                    DisplayString,
                cdx6500allportsPortSpeed
                    INTEGER,
                cdx6500allportsUtilizationIn
                    INTEGER,
                cdx6500allportsUtilizationOut
                    INTEGER,
                cdx6500allportsCharInTot
                    Counter,
                cdx6500allportsCharOutTot
                    Counter,
                cdx6500allportsPktInTot
                    Counter,
                cdx6500allportsPktOutTot
                    Counter,
                cdx6500allportsFrameInTot
                    Counter,
                cdx6500allportsFrameOutTot
                    Counter,
                cdx6500allportsPktsQueued
                    INTEGER,
                cdx6500allportsCharsInPerSec
                    INTEGER,
                cdx6500allportsCharsOutPerSec
                    INTEGER,
                cdx6500allportsPktsInPerSec
                    INTEGER,
                cdx6500allportsPktsOutPerSec
                    INTEGER,
                cdx6500allportsFramesInPerSec
                    INTEGER,
                cdx6500allportsFramesOutPerSec
                    INTEGER,
                cdx6500allportsOverrunErrors
                    Counter16,
                cdx6500allportsUnderrunErrors
                    Counter16,
                cdx6500allportsCRCErrors
                    Counter16,
                cdx6500allportsParityErrors
                    Counter16,
                cdx6500allportsFramingErrors
                    Counter16,
                cdx6500allportsBootPort
                    INTEGER,
                cdx6500allportsPortControlStatus
                    INTEGER
                }
  
        cdx6500allportsPortNum OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of the port"
        ::= { cdx6500PPSTallPortsEntry 1 }
  
        cdx6500allportsPortType OBJECT-TYPE
            SYNTAX INTEGER {
                    null      (1),
                    pad       (2),
                    x25       (3),
                    mux       (4),
                    mx25      (9),
                    bsc2780   (11),
                    bsc3270   (12),
                    vip       (13),
                    pos       (14),
                    sdlc      (15),
                    ncrbsc    (16),
                    fri       (17),
                    xdlc      (18),
                    bstd      (19),
                    rs366     (20),
                    ibm2260   (23),
                    vap       (24),
                    tbop      (25),
                    n270      (26),
                    tcop      (27),
                    tr        (28),
                    eth       (29),
                    alc       (31),
                    sl        (32),
                    fra       (33),
                    t3pos     (34),
                    atpad     (35),
                    tnpp      (36),
                    slip      (37),
                    hub       (39),
                    bri       (40),
                    x32pcm    (41),
                    ppp       (42),
                    voice     (43),
                    t1        (44),
                    e1        (45),
                    tdlc      (48),
                    ptype3201 (50),
                    gsc       (51),
                    spp       (52),
                    t1e1       (54),
                    t3e3       (55),
                    atm       (56)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Type of port."
        ::= { cdx6500PPSTallPortsEntry 2 }
  
        cdx6500allportsPortStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    disabled       (0),
                    enabled        (1),
                    busyOut        (2),
                    up             (3),
                    down           (4),
                    newvalDisabled (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Status of the port.
                 disabled - Port is disabled.
                 enabled  - Port is enabled.
                 busyOut  - Port is busyOuted.
                 up       - Port is up.
                 down     - Port is down.
                 newvalDisabled - same functionality as 'disabled',
                 new enumeration added for RFC1155 compatibility."
        ::= { cdx6500PPSTallPortsEntry 3 }
  
        cdx6500allportsPortState OBJECT-TYPE
            SYNTAX DisplayString (SIZE(1..25))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Current Port state."
        ::= { cdx6500PPSTallPortsEntry 4 }
  
        cdx6500allportsPortSpeed OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the speed of the port when Clock=Int; 
                 this is detected clock speed if Clock=Ext. 
                 If Port Speed is 0, Clock=Ext then
                 clocking is not being received from attached device."
        ::= { cdx6500PPSTallPortsEntry 5 }
  
        cdx6500allportsUtilizationIn OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Percentage of port bandwidth in use."
        ::= { cdx6500PPSTallPortsEntry 6 }

        cdx6500allportsUtilizationOut OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Percentage of port bandwidth in use."
        ::= { cdx6500PPSTallPortsEntry 7 }
  
        cdx6500allportsCharInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of characters received by the port since the 
                 last node, port or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 8 }
  
        cdx6500allportsCharOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of characters sent by the port since the last 
                 node, port or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 9 }
  
        cdx6500allportsPktInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets received by the port since the last 
                 node, port or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 10 }
  
        cdx6500allportsPktOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets sent by the port since the last node, port
                 or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 11 }
  
        cdx6500allportsFrameInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of frames received by the port since the last node, 
                 port or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 12 }
  
        cdx6500allportsFrameOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of frames sent by the port since the last node, port
                 or statistics reset."
        ::= { cdx6500PPSTallPortsEntry 13 }
  
        cdx6500allportsPktsQueued OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets currently queued."
        ::= { cdx6500PPSTallPortsEntry 14}
  
        cdx6500allportsCharsInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the characters being received over the port."
        ::= { cdx6500PPSTallPortsEntry 15 }
  
        cdx6500allportsCharsOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the characters being sent over the port."
        ::= { cdx6500PPSTallPortsEntry 16 }
  
        cdx6500allportsPktsInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the packets being received over the port."
        ::= { cdx6500PPSTallPortsEntry 17 }
  
        cdx6500allportsPktsOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the packets being sent over the port."
        ::= { cdx6500PPSTallPortsEntry 18 }
  
        cdx6500allportsFramesInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the frames being received over the port."
        ::= { cdx6500PPSTallPortsEntry 19 }
  
        cdx6500allportsFramesOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the frames being sent over the port."
        ::= { cdx6500PPSTallPortsEntry 20 }
  
        cdx6500allportsOverrunErrors OBJECT-TYPE
            SYNTAX Counter16
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Overrun errors since the last node or statistics 
                 reset.  Overrun Errors: Received data was lost because it 
                 could not be processed by the CPU."
        ::= { cdx6500PPSTallPortsEntry 21 }
  
        cdx6500allportsUnderrunErrors OBJECT-TYPE
            SYNTAX Counter16
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Underrun errors since the last node or statistics
                 reset.  UnderrunErrors: Transmission of a frame could not be 
                 completed because all the data had not been sent to port."
        ::= { cdx6500PPSTallPortsEntry 22 }
  
        cdx6500allportsCRCErrors OBJECT-TYPE
            SYNTAX Counter16
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of CRC errors since the last node or statistics reset.
                 CRC Errors: Cyclical Redundancy failure because of noise on 
                 the line."
        ::= { cdx6500PPSTallPortsEntry 23 }

        cdx6500allportsParityErrors OBJECT-TYPE
            SYNTAX Counter16
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Parity errors since the last reset"
        ::= { cdx6500PPSTallPortsEntry 24 }

        cdx6500allportsFramingErrors OBJECT-TYPE
            SYNTAX Counter16
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of Framing errors since the last reset."
        ::= { cdx6500PPSTallPortsEntry 25 }

        cdx6500allportsBootPort OBJECT-TYPE
            SYNTAX INTEGER {
                    bootPort (1)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Boots the specified Port.
                 bootPort - Boot the Port."
        ::= { cdx6500PPSTallPortsEntry 26 }

        cdx6500allportsPortControlStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    enable  (1),
                    disable (2),
                    busyout (3)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Change the Port Control Status.
                 enable  - Enable the Port.
                 disable - Disable the Port.
                 busyout - BusyOut the Port."
        ::= { cdx6500PPSTallPortsEntry 27 }

        -- The allStations Statistics Table
        -- This table contains statistic paramaters 
        -- for the allStations table.
    
    
        cdx6500SPSTallStationsTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500SPSTallStationsEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "All of the statistics parameters relevant
                 to the allStations table."
        ::= { cdx6500PSTStationProtocolGroup 8 }
  
        cdx6500SPSTallStationsEntry OBJECT-TYPE
            SYNTAX Cdx6500SPSTallStationsEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A row of allStations statistics parameters."
            INDEX { cdx6500allstationsPortNum,
                    cdx6500allstationsStnNum }
        ::= { cdx6500SPSTallStationsTable 1 }
  
        Cdx6500SPSTallStationsEntry ::=
            SEQUENCE {
                cdx6500allstationsPortNum
                    INTEGER,
                cdx6500allstationsStnNum
                    INTEGER,
                cdx6500allstationsStnType
                    DisplayString,
                cdx6500allstationsStnStatus
                    INTEGER,
                cdx6500allstationsStnState
                    DisplayString,
                cdx6500allstationsUtilizationIn
                    INTEGER,
                cdx6500allstationsUtilizationOut
                    INTEGER,
                cdx6500allstationsCharInTot
                    Counter,
                cdx6500allstationsCharOutTot
                    Counter,
                cdx6500allstationsPktInTot
                    Counter,
                cdx6500allstationsPktOutTot
                    Counter,
                cdx6500allstationsFrameInTot
                    Counter,
                cdx6500allstationsFrameOutTot
                    Counter,
                cdx6500allstationsPktsQueued
                    INTEGER,
                cdx6500allstationsCharsInPerSec
                    INTEGER,
                cdx6500allstationsCharsOutPerSec
                    INTEGER,
                cdx6500allstationsPktsInPerSec
                    INTEGER,
                cdx6500allstationsPktsOutPerSec
                    INTEGER,
                cdx6500allstationsFramesInPerSec
                    INTEGER,
                cdx6500allstationsFramesOutPerSec
                    INTEGER,
                cdx6500allstationsBootStation
                    INTEGER,
                cdx6500allstationsDisableStation
                    INTEGER,
                cdx6500allstationsEnableStation
                    INTEGER,
                cdx6500allstationsBusyOutStation
                    INTEGER
                }
  
        cdx6500allstationsPortNum OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of the port."
        ::= { cdx6500SPSTallStationsEntry 1 }
  
        cdx6500allstationsStnNum OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of the station."
        ::= { cdx6500SPSTallStationsEntry 2 }
  
        cdx6500allstationsStnType OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..10))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Type of station."
        ::= { cdx6500SPSTallStationsEntry 3 }
  
        cdx6500allstationsStnStatus OBJECT-TYPE
            SYNTAX INTEGER {
                    disabled       (0),
                    enabled        (1),
                    busyOut        (2),
                    up             (3),
                    down           (4),
                    newvalDisabled (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Status of the station.
                 disabled  - Station is disabled.
                 enabled   - Station is enabled.
                 busyOut   - Station is busyOuted.
                 up        - Station is up.
                 down      - Station is down.
                 newvalDisabled - same functionality as 'disabled',
                 new enumeration added for RFC1155 compatibility."
        ::= { cdx6500SPSTallStationsEntry 4 }
  
        cdx6500allstationsStnState OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..15))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Current Station state."
        ::= { cdx6500SPSTallStationsEntry 5 }
  
        cdx6500allstationsUtilizationIn OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Percentage of station bandwidth in use."
        ::= { cdx6500SPSTallStationsEntry 6 }
  
        cdx6500allstationsUtilizationOut OBJECT-TYPE
            SYNTAX INTEGER (0..100)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Percentage of station bandwidth in use."
        ::= { cdx6500SPSTallStationsEntry 7 }
  
        cdx6500allstationsCharInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of characters received by the station since the 
                 last node, port, station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 8 }
  
        cdx6500allstationsCharOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of characters sent by the station since the last 
                 node, port, station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 9 }
  
        cdx6500allstationsPktInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets received by the station since the last 
                 node, port, station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 10 }
  
        cdx6500allstationsPktOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets sent by the port since the last node, port,
                 station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 11 }
  
        cdx6500allstationsFrameInTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of frames received by the port since the last node,
                 port, station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 12 }
  
        cdx6500allstationsFrameOutTot OBJECT-TYPE
            SYNTAX Counter
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of frames sent by the port since the last node, port,
                 station or statistics reset."
        ::= { cdx6500SPSTallStationsEntry 13 }
  
        cdx6500allstationsPktsQueued OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of packets currently queued."
        ::= { cdx6500SPSTallStationsEntry 14}
  
        cdx6500allstationsCharsInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the characters being received over the station."
        ::= { cdx6500SPSTallStationsEntry 15 }
  
        cdx6500allstationsCharsOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the characters being sent over the station."
        ::= { cdx6500SPSTallStationsEntry 16 }
  
        cdx6500allstationsPktsInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the packets being received over the station."
        ::= { cdx6500SPSTallStationsEntry 17 }
  
        cdx6500allstationsPktsOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the packets being sent over the station."
        ::= { cdx6500SPSTallStationsEntry 18 }
  
        cdx6500allstationsFramesInPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the frames being received over the station."
        ::= { cdx6500SPSTallStationsEntry 19 }

        cdx6500allstationsFramesOutPerSec OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Summary of the frames being sent over the station."
        ::= { cdx6500SPSTallStationsEntry 20 }

        cdx6500allstationsBootStation OBJECT-TYPE
            SYNTAX INTEGER {
                    bootStn   (1),
                    noBootStn (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                 "Boots the specified station.
                  bootStn   - Boot Station
                  noBootStn - Do not boot Station."
        ::= { cdx6500SPSTallStationsEntry 21 }
  
        cdx6500allstationsDisableStation OBJECT-TYPE
            SYNTAX INTEGER {
                    disableStn   (1),
                    noDisableStn (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Disables the specified station.
                 disableStn   - Disable Station.
                 noDisableStn - Do not disable Station."
        ::= { cdx6500SPSTallStationsEntry 22 }
  
        cdx6500allstationsEnableStation OBJECT-TYPE
            SYNTAX INTEGER {
                    enableStn   (1),
                    noEnableStn (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Enables the specified station.
                 enableStn   - Enable Station.
                 noEnableStn - Not not enable Station."
        ::= { cdx6500SPSTallStationsEntry 23 }
  
        cdx6500allstationsBusyOutStation OBJECT-TYPE
            SYNTAX INTEGER {
                    busyoutStn   (1),
                    noBusyoutStn (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Busy out the specified station.
                 busyoutStn   - Busyout Station.
                 noBusyoutStn - Do not busyout Station."
        ::= { cdx6500SPSTallStationsEntry 24 }


        -- General Objects
        -- The ROUT selection configuration table
        -- Implementation of the ROUT group is mandatory for Pegasus BN.
        -- It is also available on the other 65xx and VGxxx platforms.

        cdx6500GCTRouteSelectionTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500GCTRouteSelectionEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of Configuration Parameters that select
                 the links over which calls are routed."
        ::= { cdx6500CfgGeneralGroup 1 }

        cdx6500GCTRouteSelectionEntry OBJECT-TYPE
            SYNTAX Cdx6500GCTRouteSelectionEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each entry contains a list of parameters that 
                 makeup the Route Selection Table."
            INDEX { cdx6500RoutSVCEntryNumber }
        ::= { cdx6500GCTRouteSelectionTable 1 }

        Cdx6500GCTRouteSelectionEntry ::=
            SEQUENCE {
                cdx6500RoutSVCEntryNumber
                    INTEGER,
                cdx6500RoutSVCAddress
                    INTEGER,
                cdx6500RoutSVCDestination1
                    DisplayString,
                cdx6500RoutSVCPriority1
                    INTEGER,
                cdx6500RoutSVCDestination2
                    DisplayString,
                cdx6500RoutSVCPriority2
                    INTEGER,
                cdx6500RoutSVCDestination3
                    DisplayString,
                cdx6500RoutSVCPriority3
                    INTEGER,
                cdx6500RoutSVCDestination4
                    DisplayString,
                cdx6500RoutSVCPriority4
                    INTEGER,
                cdx6500RoutSVCDestination5
                    DisplayString,
                cdx6500RoutSVCPriority5
                    INTEGER,
                cdx6500RoutSVCDestination6
                    DisplayString,
                cdx6500RoutSVCPriority6
                    INTEGER,
                cdx6500RoutSVCDestination7
                    DisplayString,
                cdx6500RoutSVCPriority7
                    INTEGER,
                cdx6500RoutSVCDestination8
                    DisplayString,
                cdx6500RoutSVCPriority8
                    INTEGER,
                cdx6500RoutSVCAddress1
                    DisplayString
                }

        cdx6500RoutSVCEntryNumber OBJECT-TYPE
            SYNTAX INTEGER (1..128)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is not a configurable parameter. 
                 This identifies the particular Route 
                 Selection Table entry being configured by 
                 the other parameters in the record."
        ::= { cdx6500GCTRouteSelectionEntry 1 }


        cdx6500RoutSVCAddress OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS deprecated
            DESCRIPTION
                "This is a non-supported object.
                 It has been replaced by cdx6500RoutSVCAddress1."
        ::= { cdx6500GCTRouteSelectionEntry 2 }

        cdx6500RoutSVCDestination1 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 3 }

        cdx6500RoutSVCPriority1 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 4 }

        cdx6500RoutSVCDestination2 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 5 }

        cdx6500RoutSVCPriority2 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 6 }

        cdx6500RoutSVCDestination3 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 7 }

        cdx6500RoutSVCPriority3 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 8 }

        cdx6500RoutSVCDestination4 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 9 }

        cdx6500RoutSVCPriority4 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 10 }

        cdx6500RoutSVCDestination5 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 11 }

        cdx6500RoutSVCPriority5 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 12 }

        cdx6500RoutSVCDestination6 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 13 }

        cdx6500RoutSVCPriority6 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 14 }

        cdx6500RoutSVCDestination7 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 15 }

        cdx6500RoutSVCPriority7 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 16 }

        cdx6500RoutSVCDestination8 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the network address to 
                 which calls are routed. For example: 
                 BCST         route calls to the broadcast module.
                 BSC2780-4    route calls to BSC2780 port 4.
                 BSC3270-9    route calls to BSC3270 port 9.
                 MX25-2s3     route calls to MX25 port 2, station 3.
                 PAD-5        route calls to PAD port 5.
                 P54s9        route calls to port 54, station 9.
                 SDLC-4s5     route calls to SDLC port 4, station 5.
                 X25-1        route calls to X25 port 1.
                 BOSTON       route backup calls to BOSTON resource."
        ::= { cdx6500GCTRouteSelectionEntry 17 }

        cdx6500RoutSVCPriority8 OBJECT-TYPE
            SYNTAX INTEGER (0..15)
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This specifies the priority for call forwarding 
                 to ports within the Route Selection Table. Call 
                 forwarding is determined by a combination of priority
                 and load conditions. 
                 0         - backup port.
                 1 to 15   - 1 is the highest priority and 15, the lowest."
        ::= { cdx6500GCTRouteSelectionEntry 18 }

        cdx6500RoutSVCAddress1 OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "Network address for calls routed beyond this 
                 node. A route selection entry is not needed 
                 for calls destined within this node: PAD port
                 or node resource (for example, control port) 
                 calls. The wild card(match anything) character
                 is * and can also be part of the entry. When 
                 set to (blank), this parameter is ignored."
        ::= { cdx6500GCTRouteSelectionEntry 19 }

        -- The PVC Setup configuration table

        cdx6500GCTPVCSetupTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500GCTPVCSetupEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of Configuration Parameters for PVCs."
        ::= { cdx6500CfgGeneralGroup 5 }

        cdx6500GCTPVCSetupEntry OBJECT-TYPE
            SYNTAX Cdx6500GCTPVCSetupEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each entry contains a PVC source and PVC destination."
            INDEX { cdx6500PVCSetupEntryNumber }
        ::= { cdx6500GCTPVCSetupTable 1 }

        Cdx6500GCTPVCSetupEntry ::=
            SEQUENCE {
                cdx6500PVCSetupEntryNumber
                    INTEGER,
                cdx6500PVCSetupSource
                    DisplayString,
                cdx6500PVCSetupDestination
                    DisplayString
                }

        cdx6500PVCSetupEntryNumber OBJECT-TYPE
            SYNTAX INTEGER (1..256)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is not a configurable parameter. 
                 This identifies the particular PVC Table entry being 
                 configured by the other parameters in the record."
        ::= { cdx6500GCTPVCSetupEntry 1 }

        cdx6500PVCSetupSource OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This is the PVC source channel identifier.  
                 Entries are not case sensitive. For example:
                 BCST        route calls to the broadcast module.
                 MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2.
                 PAD-5       route calls to PAD port 5.
                 P54S9(22)   route calls to port 54, station 9, channel 22.
                 SDLC-4s5    route calls to SDLC port 4, station 5.
                 X25-1(5)    route calls to X25 port 1, channel 5."
        ::= { cdx6500GCTPVCSetupEntry 2 }

        cdx6500PVCSetupDestination OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This is the PVC destination channel identifier.  
                 Entries are not case sensitive. For example:
                 BCST        route calls to the broadcast module.
                 MX25-2s3(2) route calls to MX25 port 2, station 3, channel 2.
                 PAD-5       route calls to PAD port 5.
                 P54S9(22)   route calls to port 54, station 9, channel 22.
                 SDLC-4s5    route calls to SDLC port 4, station 5.
                 X25-1(5)    route calls to X25 port 1, channel 5."
        ::= { cdx6500GCTPVCSetupEntry 3 }

        -- The Mnemonic Configuration Table
        -- This table contains Configuration paramaters 
        -- for the Mnemonic table.

        cdx6500CfgMnemonicTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500CfgMnemonicEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "All of the configuration parameters relevant
                 to the Mnemonic table."
        ::= { cdx6500CfgGeneralGroup 6 }

        cdx6500CfgMnemonicEntry OBJECT-TYPE
            SYNTAX Cdx6500CfgMnemonicEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A row of mnemonic configuration parameters."
            INDEX { cdx6500mnemEntryNum }
        ::= { cdx6500CfgMnemonicTable 1 }

        Cdx6500CfgMnemonicEntry ::=
            SEQUENCE {
                cdx6500mnemEntryNum
                    INTEGER,
                cdx6500mnemName
                    DisplayString,
                cdx6500mnemx28Cmd
                    DisplayString
                }

        cdx6500mnemEntryNum OBJECT-TYPE
            SYNTAX INTEGER (1..256)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is not a configuration parameter. Instead, it
                 identifies the particular Mnemonic Table entry being
                 configured by the other parameters in the record.
                 NOTE: You can have up to 256 entries for the 6507Plus 
                 and 6525Plus, but only 64 entries for the 6505Plus."
        ::= { cdx6500CfgMnemonicEntry 1 }
  
        cdx6500mnemName OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is an mnemonic name available to PAD port users for
                 abbreviated calling or autocalling. The following parameter
                 will specify call details. The mnemonic CTP is reserved 
                 and specifies a call to the control port."
        ::= { cdx6500CfgMnemonicEntry 2 }

        cdx6500mnemx28Cmd OBJECT-TYPE
            SYNTAX DisplayString (SIZE (0..64))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This specifies call details for the mnemonic configured 
                 in the previous parameter. Use the format of an X.28 call 
                 command, but leave out the command specifier 
                 (the c or call)."
        ::= { cdx6500CfgMnemonicEntry 3 }

        -- The CSIS NUI Password Table 

        cdx6500GCTNUIPasswordTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500GCTNUIPasswordEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of NUI/Password configuration entries."
        ::= { cdx6500CfgGeneralGroup 7 }

        cdx6500GCTNUIPasswordEntry OBJECT-TYPE
            SYNTAX Cdx6500GCTNUIPasswordEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "The Network User Identification (NUI)/Password Table."
            INDEX { cdx6500NUITEntryNumber }
        ::= { cdx6500GCTNUIPasswordTable 1 }

        Cdx6500GCTNUIPasswordEntry ::=
            SEQUENCE {
                cdx6500NUITEntryNumber
                    INTEGER,
                cdx6500NUITAcctName
                    DisplayString,
                cdx6500NUITPasswd
                    DisplayString,
                cdx6500NUITPADPromptNum
                    INTEGER
                }

        cdx6500NUITEntryNumber OBJECT-TYPE
            SYNTAX INTEGER (1..400)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is not a configurable parameter. Instead, it
                  identifies the particular NUI/Password Table entry being
                  configured by the other parameters in the record."
        ::= { cdx6500GCTNUIPasswordEntry 1 }

        cdx6500NUITAcctName OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the account name for billing records."
        ::= { cdx6500GCTNUIPasswordEntry 2 }

        cdx6500NUITPasswd OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..8))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is the password for the account name."
        ::= { cdx6500GCTNUIPasswordEntry 3 }

        cdx6500NUITPADPromptNum OBJECT-TYPE
            SYNTAX INTEGER (0..8)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This parameter specifies which entry in the PAD Prompt
                 Table is used as a PAD prompt after the user has entered
                 a valid password. Use 0 for standard asterisk prompt."
        ::= { cdx6500GCTNUIPasswordEntry 4 }

        -- The CSIS Software Key Table 

        cdx6500GCTSoftwareKeyTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500GCTSoftwareKeyEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A table of Software Key configuration entries."
        ::= { cdx6500CfgGeneralGroup 12 }

        cdx6500GCTSoftwareKeyEntry OBJECT-TYPE
            SYNTAX Cdx6500GCTSoftwareKeyEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "The Software Key for a specific optional software
                 product code."
            INDEX { cdx6500CSISSoftKeyEntryNumber }
        ::= { cdx6500GCTSoftwareKeyTable 1 }

        Cdx6500GCTSoftwareKeyEntry ::=
            SEQUENCE {
                cdx6500CSISSoftKeyEntryNumber
                    INTEGER,
                cdx6500CSISSoftKeyValue
                    DisplayString
                }

        cdx6500CSISSoftKeyEntryNumber OBJECT-TYPE
            SYNTAX INTEGER (1..20)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is not a configurable parameter. It is the reference
                 number for the individual software option that is being
                 enabled. You must configure a separate entry for each
                 software option enabled at the node. A node may have up
                 to 20 options enabled at one time."
        ::= { cdx6500GCTSoftwareKeyEntry 1 }

        cdx6500CSISSoftKeyValue OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..20))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This is a software key supplied by Codex Corporation for
                 this node."
        ::= { cdx6500GCTSoftwareKeyEntry 2 }

          -- Other Statistics
          -- CSIS Option and Port Authorization

        cdx6500OSTCSISOptionStatTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500OSTCSISOptionStatEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A table describing the Software Options that have been
                 purchased and enabled for this node."
        ::= { cdx6500StatOtherStatsGroup 5 }

        cdx6500OSTCSISOptionStatEntry OBJECT-TYPE
            SYNTAX Cdx6500OSTCSISOptionStatEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of objects describing a single Software Option."
            INDEX { cdx6500CSISOptionNumber }
        ::= { cdx6500OSTCSISOptionStatTable 1 }

        Cdx6500OSTCSISOptionStatEntry ::=
            SEQUENCE {
                cdx6500CSISOptionNumber
                    INTEGER,
                cdx6500CSISMaxAllowed
                    INTEGER,
                cdx6500CSISNumUsed
                    INTEGER,
                cdx6500CSISOptionAuth
                    INTEGER
                }

        cdx6500CSISOptionNumber OBJECT-TYPE
            SYNTAX INTEGER (1..55)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Table index, which is code for the software option.
                 Following are the various software options and their codes.
                 1   -  MX25                                        
                 2   -  SDLC                                        
                 3   -  BSC3270                                     
                 4   -  BSC2780                                     
                 5   -  VIP                                         
                 6   -  VIDEOTEX                                    
                 7   -  Data/Connection Protect                     
                 8   -  INL backup                                  
                 9   -  FR DTE Interface                            
                 10  -  6600 ETM                                    
                 11  -  NCRBSC                                      
                 12  -  TRANSPARENT POLLED ASYNC                    
                 13  -  INTERNAL DSD                                
                 14  -  801 AUTODIALER                              
                 15  -  BSTD                                        
                 16  -  FLASH Enable                                
                 17  -  NCCP Pad                                    
                 18  -  TBOP                                        
                 19  -  Source Routing Bridge                       
                 22  -  IBM2260                                     
                 23  -  XDLC                                        
                 24  -  Transparent Bridge                          
                 25  -  Local Termination                           
                 26  -  SR/TB Bridge                                
                 29  -  IP Routing                                  
                 31  -  FR DCE Interface                            
                 32  -  6520 Model ID RN                            
                 33  -  6520 Model ID SN                            
                 34  -  6520 Model ID BN                            
                 40  -  TCOP                                        
                 42  -  FrameRelay LLC Conversion                   
                 43  -  IP stack on CPU+                            
                 44  -  TNPP-PAD Enable                             
                 45  -  Token Ring LLC Conversion                   
                 46  -  Ethernet LLC Conversion                     
                 50  -  Dial-Out Routing Manager                    
                 51  -  Dial-Out Routing Agent                      
                 52  -  Chinapac Billing Feature                    
                 53  -  Chinapac NUIC Interface                     
                 54  -  X32 Port                                    
                 55  -  Chinapac NUI Concentrator."
        ::= { cdx6500OSTCSISOptionStatEntry 1 }

        cdx6500CSISMaxAllowed OBJECT-TYPE
            SYNTAX INTEGER (1..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Number of ports that this option can support. Options
                 can be purchased to support different numbers of ports.
                 Value of 65535 indicates no limit."
        ::= { cdx6500OSTCSISOptionStatEntry 2 }

        cdx6500CSISNumUsed OBJECT-TYPE
            SYNTAX INTEGER (0..54)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The number of ports actually being used with this
                 option."
        ::= { cdx6500OSTCSISOptionStatEntry 3 }

        cdx6500CSISOptionAuth OBJECT-TYPE
            SYNTAX INTEGER {
                    unauthorized (1),
                    authorized   (2)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "unauthorized - an attempt was made to use an option
                                that has not been purchased or enabled.
                 authorized   - all attempts to use the option were
                                authorized."
        ::= { cdx6500OSTCSISOptionStatEntry 4 }

        -- CSIS Port Authorization Statistics

        cdx6500OSTCSISPortUsageTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500OSTCSISPortUsageEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A table providing statistics on unauthorized port
                 usage."
        ::= { cdx6500StatOtherStatsGroup 6 }

        cdx6500OSTCSISPortUsageEntry OBJECT-TYPE
            SYNTAX Cdx6500OSTCSISPortUsageEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A list of authorization statistics for a single port."
            INDEX { cdx6500CSISPortNumber }
        ::= { cdx6500OSTCSISPortUsageTable 1 }

        Cdx6500OSTCSISPortUsageEntry ::=
            SEQUENCE {
                cdx6500CSISPortNumber
                    INTEGER,
                cdx6500CSISPortAuth
                    INTEGER
                }

        cdx6500CSISPortNumber OBJECT-TYPE
            SYNTAX INTEGER (1..54)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "The port's number."
        ::= { cdx6500OSTCSISPortUsageEntry 1 }

        cdx6500CSISPortAuth OBJECT-TYPE
            SYNTAX INTEGER {
                    unauthorized (1),
                    authorized   (2)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "unauthorized - an attempt was made to use this port to
                                exceed an option port limit.
                 authorized   - the port was not used in an unauthorized
                                 fashion."
        ::= { cdx6500OSTCSISPortUsageEntry 2 }

        -- SVC calls table

        cdx6500StatSVCTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500StatSVCEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A table of currently active switched virtual circuits (SVC).
                 The table is dynamic i.e. changing as queries are being 
                 performed on the table."
        ::= { cdx6500StatNetworkSvcsGroup 1}

        cdx6500StatSVCEntry OBJECT-TYPE
            SYNTAX Cdx6500StatSVCEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION 
                "A list of objects describing a single SVC."
            INDEX { cdx6500StatSVCIndex}
        ::= { cdx6500StatSVCTable 1}

        Cdx6500StatSVCEntry ::= 
            SEQUENCE {
                cdx6500StatSVCIndex
                    INTEGER,
                cdx6500StatSVCCallingChannel
                    DisplayString,
                cdx6500StatSVCCalledChannel
                    DisplayString,
                cdx6500StatSVCReverseCharge
                    INTEGER,
                cdx6500StatSVCFastSelect             
                    INTEGER,
                cdx6500StatSVCNetUserIdentification
                    INTEGER,
                cdx6500StatSVCClosedUserGroup
                    INTEGER,
                cdx6500StatSVCConnectionUPTime
                    DisplayString
                }

        cdx6500StatSVCIndex  OBJECT-TYPE
            SYNTAX INTEGER (1..65535)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "It is position in the list of SVC's."
        ::= { cdx6500StatSVCEntry 1 }
         
        cdx6500StatSVCCallingChannel OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..17))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Calling channel of SVC."
        ::= { cdx6500StatSVCEntry 2 }

        cdx6500StatSVCCalledChannel OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..17))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Called channel of SVC."
        ::= { cdx6500StatSVCEntry 3 }

        cdx6500StatSVCReverseCharge OBJECT-TYPE
            SYNTAX INTEGER {
                    refuse       (0),
                    accept       (1),
                    newvalRefuse (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Reverse charge facility condition.
                 refuse       -  Refused the condition.
                 accept       -  Accepted the condition.
                 newvalRefuse -  same functionality as 'refuse', new
                                 enumeration added for RFC1155 compatibility."
        ::= { cdx6500StatSVCEntry 4 }

        cdx6500StatSVCFastSelect  OBJECT-TYPE
            SYNTAX INTEGER {
                    noFastSelect       (0),
                    fastSelect         (1),
                    newvalNoFastSelect (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Fast select facility condition.
                 noFastSelect   -  Fast select facility is not selected.
                 fastSelect     -  Fast select facility is selected.
                 newvalNoFastSelect - same functionality as 'noFastSelect',
                                   new enumeration added for RFC1155 
                                   compatibility."
        ::= { cdx6500StatSVCEntry 5}

        cdx6500StatSVCNetUserIdentification  OBJECT-TYPE
            SYNTAX INTEGER {
                    notRequested       (0),
                    requested          (1),
                    newvalNotRequested (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Net user identifiaction facility condition.
                 notRequested    -  Net user identifiaction facility not requested.
                 requested       -  Net user identifiaction facility  requested.
                 newvalNotRequested - same functionality as 'notRequested', new
                                    enumeration added for RFC1155 compatibility."
        ::= { cdx6500StatSVCEntry 6}

        cdx6500StatSVCClosedUserGroup  OBJECT-TYPE
            SYNTAX INTEGER {
                    notRequested       (0),
                    requested          (1),
                    newvalNotRequested (50)
                    }
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Closed user group facility on/off.
                 notRequested   - Closed user group facility off.
                 requested      - Closed user group facility on.
                 newvalNotRequested - same functionality as 'notRequested', new
                                  enumeration added for RFC1155 compatibility."
        ::= { cdx6500StatSVCEntry 7}

        cdx6500StatSVCConnectionUPTime  OBJECT-TYPE
            SYNTAX DisplayString (SIZE(0..21))
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Time at which connection was up."
        ::= { cdx6500StatSVCEntry 8}

        -- STAT module control parameter

        cdx6500statResetAllStats OBJECT-TYPE
            SYNTAX INTEGER {
                    reset   (1),
                    noReset (2)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "A control object that when set to reset will cause the
                 node to reset ALL its statistics.
                 reset   -  reset ALL node statistics.
                 noReset -  Do not reset the statistics."
        ::= { cdx6500statControls 1 }

       -- Flash Control Group

        cdx6500ContFlashCopyImage OBJECT-TYPE
            SYNTAX INTEGER {
                    currentToalternate   (1),
                    alternateTocurrent   (2),
                    noOperation        (100)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Copy image from current to alternate or
                 alternate to current."
        ::= { cdx6500ContFlash 1 }

        cdx6500ContFlashCopyCmem OBJECT-TYPE
            SYNTAX INTEGER {
                    currentToalternate   (1),
                    alternateTocurrent   (2),
                    noOperation        (100)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Copy cmem from current to alternate or
                 alternate to current."
        ::= { cdx6500ContFlash 2 }

        cdx6500ContFlashActiveImage OBJECT-TYPE
            SYNTAX INTEGER {
                    setcurrentImage   (1),
                    setalternateImage   (2),
                    noOperation        (100)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Activate image in flash memory."
        ::= { cdx6500ContFlash 3 }

        cdx6500ContFlashActiveCmem OBJECT-TYPE
            SYNTAX INTEGER {
                    setcurrentCmem   (1),
                    setalternateCmem   (2),
                    noOperation        (100)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Activate cmem in flash memory."
        ::= { cdx6500ContFlash 4 }

        cdx6500ContFlashDeleteImage OBJECT-TYPE
            SYNTAX INTEGER {
                    deleteImage   (1),
                    noOperation        (100)
                    }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Delete all images in flash memory."
        ::= { cdx6500ContFlash 5 }

   -- Control creating and station

        cdx6500CreatePortAndStationTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500CreatePortAndStationEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                 "Create Port and Station table."
        ::= { cdx6500CfgProtocolGroup 9 }

        cdx6500CreatePortAndStationEntry OBJECT-TYPE
            SYNTAX Cdx6500CreatePortAndStationEntry 
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Entry for representing Creating Port
		 and Station  Record."
            INDEX {cdx6500PortNumber}
        ::= { cdx6500CreatePortAndStationTable 1 }

        Cdx6500CreatePortAndStationEntry ::= SEQUENCE {
            cdx6500PortNumber        INTEGER,
            cdx6500CreatePortType    INTEGER,
            cdx6500CreateStation     INTEGER
                    }

        cdx6500PortNumber  OBJECT-TYPE
            SYNTAX INTEGER(1..256)
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "Port Number which is installed."
            ::= { cdx6500CreatePortAndStationEntry 1 }

        cdx6500CreatePortType  OBJECT-TYPE
            SYNTAX INTEGER {
			pad (2),
			x25 (3),
			mx25 (9),
			sdlc (15),
			fri (17),
			xdlc (18),
			tr (28),
			eth (29),
			fra (33)
			}
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION "port type to be created.
			pad  : PAD port
			x25  : X25 port
			mx25 : Multipoint X25 port
			sdlc : Synchronous Data Link Control Port
			xdlc : X25 Data Link Control Port
			fri  : Frame Relay Interface Port
			tr   : Token Ring Port
			eth  : Ethernet Port
			fra  : Frame Relay Access Port."
            ::= { cdx6500CreatePortAndStationEntry 2 }

        cdx6500CreateStation  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION "station number to be created.
			 The instance should be existing port number.
			 Station Range : 1 - Max Station Number."
            ::= { cdx6500CreatePortAndStationEntry 3 }

 	cdx6500LconPortTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500LconPortEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "This table contains port and assocaited Lcon
                 parameters."
        ::= { cdx6500CfgGeneralGroup 32 }

        cdx6500LconPortEntry OBJECT-TYPE
            SYNTAX  Cdx6500LconPortEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "Entries in the Lcon and Port Table."
            INDEX  { LconifFriPortNumberIndex, LconDlci  }
        ::= { cdx6500LconPortTable 1 }

        Cdx6500LconPortEntry ::=
            SEQUENCE {
                LconifFriPortNumberIndex
                    INTEGER,
                LconDlci
                    INTEGER,
                LconNumber
                    INTEGER,
                LconFriPortNumber
                    INTEGER,
                LconFriStnNumber
                    INTEGER,
                LconIpAddress
                    IpAddress,
                LconIpSubnetMask
                    IpAddress
             }

        LconifFriPortNumberIndex  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "The ifIndex Value of the ifEntry."
            ::= { cdx6500LconPortEntry 1 }

        LconDlci  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "DLCI number which is associated with Lcon."
            ::= { cdx6500LconPortEntry 2 }

        LconNumber  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "Lcon number which is associated with this circuit."
            ::= { cdx6500LconPortEntry 3 }

        LconFriPortNumber  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "Port number which is associated with Lcon."
            ::= { cdx6500LconPortEntry 4 }

        LconFriStnNumber  OBJECT-TYPE
            SYNTAX INTEGER
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION "Station number which is associated with Lcon."
            ::= { cdx6500LconPortEntry 5 }
        LconIpAddress OBJECT-TYPE
            SYNTAX IpAddress
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Ip Address which is associated with Lcon."
            ::= { cdx6500LconPortEntry 6 }

        LconIpSubnetMask OBJECT-TYPE
            SYNTAX IpAddress
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "Ip Address Mask which is associated with Lcon."
            ::= { cdx6500LconPortEntry 7 }


        -- The T3E3 Port Control Table

        cdx6500ContT3E3Table OBJECT IDENTIFIER
        ::= { cdx6500Controls 23 }

        cdx6500T3E3ContEntry OBJECT-TYPE
            SYNTAX Cdx6500T3E3ContEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Each control applies to a single T3E3 port."
            INDEX { t3e3ContPortNumber }
        ::= { cdx6500ContT3E3Table 1 }

        Cdx6500T3E3ContEntry ::=
            SEQUENCE {
                t3e3ContPortNumber
                    INTEGER,
                t3e3ContPortControl
                    INTEGER
                }

        t3e3ContPortNumber OBJECT-TYPE
            SYNTAX INTEGER (1..65535)
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "Port number of the T3E3 port."
        ::= { cdx6500T3E3ContEntry 1 }

        t3e3ContPortControl OBJECT-TYPE
            SYNTAX INTEGER {
                   boot       (1),
                   enable     (2),
                   disable    (3),
                   resetstats (4)
                   }
            ACCESS write-only
            STATUS mandatory
            DESCRIPTION
                "Control operations for the specified T3E3 port.
                 boot       - Boots the T3E3 port
                 enable     - Enables the T3E3 port
                 disable    - Disables the T3E3 port
                 resetstats - Resets the T3E3 port statistics."
        ::= { cdx6500T3E3ContEntry 2 }
	
	-- The DSCP-to-CoS Mapping Profile
        -- This table contains the DSCP-to-CoS Mapping Profile 

        cdx6500CfgDSCPtoCoSTable OBJECT-TYPE
            SYNTAX SEQUENCE OF Cdx6500CfgDSCPtoCoSEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "All of the configuration parameters relevant
                 to the DSCP-to-CoS Mapping Profile table."
        ::= { cdx6500CfgGeneralGroup 36 }

        cdx6500CfgDSCPtoCoSEntry OBJECT-TYPE
            SYNTAX Cdx6500CfgDSCPtoCoSEntry
            ACCESS not-accessible
            STATUS mandatory
            DESCRIPTION
                "A row of DSCP-to-CoS entries."
            INDEX { cdx6500DSCPtoCoSProfile, cdx6500DSCPtoCoSEntryNum }
        ::= { cdx6500CfgDSCPtoCoSTable 1 }

        Cdx6500CfgDSCPtoCoSEntry ::=
            SEQUENCE {
                cdx6500DSCPtoCoSProfile
                    INTEGER,
                cdx6500DSCPtoCoSEntryNum
                    INTEGER,
                cdx6500DSCPValue
                    DisplayString,
                cdx6500CoSValue
                    DisplayString
                }

        cdx6500DSCPtoCoSProfile OBJECT-TYPE
            SYNTAX INTEGER 
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This value represents the profile number."
        ::= { cdx6500CfgDSCPtoCoSEntry 1 }        

        cdx6500DSCPtoCoSEntryNum OBJECT-TYPE
            SYNTAX INTEGER 
            ACCESS read-only
            STATUS mandatory
            DESCRIPTION
                "This value identifies the particular DSCP-to-CoS 
                 Mapping Profile entry being configured by the 
                 other parameters in the record."
        ::= { cdx6500CfgDSCPtoCoSEntry 2 }
  
        cdx6500DSCPValue OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                "This value specifies the DSCP value(s) that will
                 be mapped to the specified CoS value.  The values
                 are specified as a list of values and/or ranges.  A
                 maximum of 5 ranges is supported per entry."
        ::= { cdx6500CfgDSCPtoCoSEntry 3 }

        cdx6500CoSValue OBJECT-TYPE
            SYNTAX DisplayString
            ACCESS read-write
            STATUS mandatory
            DESCRIPTION
                  "This value specifies the CoS value that will be
                   set for packets with any of the DSCP values
                   specified in the associated DSCP Value(s) entry"
        ::= { cdx6500CfgDSCPtoCoSEntry 4 }

END