--/*    (C)COPYRIGHT OKIDATA CORPORATION 1998.                          */
--/*        ALL RIGHTS RESERVED                                                                                 */      
--/*                    Ver. 4.9        2000.05.12                                                      */
--/*                            (MIB System Specification Ver4.9 support)                       */
--/**********************************************************************/

                  OKIDATA-MIB DEFINITIONS ::= BEGIN

          IMPORTS
                                private, enterprises, NetworkAddress, IpAddress, 
                                Counter, Gauge,TimeTicks
                                        FROM RFC1155-SMI
                                DisplayString,mib-2,PhysAddress
                                        FROM RFC1213-MIB
                                OBJECT-TYPE
                                        FROM RFC-1212
											TRAP-TYPE FROM RFC-1215
                                ;
                                        
        -- OKIDATA PRIVATE-MIB

                okidata         OBJECT IDENTIFIER ::= {enterprises 2001}

                -- groups in OKIDATA PRIVATE-MIB

                peripheral      OBJECT IDENTIFIER ::= {okidata 1}

                -- the Peripheral group

                printer         OBJECT IDENTIFIER ::= {peripheral 1}

                printserver     OBJECT IDENTIFIER ::= {peripheral 2}

                -- the Printer group    

                nip                     OBJECT IDENTIFIER ::= {printer 1}

                inkjet          OBJECT IDENTIFIER ::= {printer 2}

                fax                     OBJECT IDENTIFIER ::= {printer 3}

                mfp                     OBJECT IDENTIFIER ::= {printer 4}

                sidm            OBJECT IDENTIFIER ::= {printer 5}

                -- the Nip group

                niptype1        OBJECT IDENTIFIER ::= {nip 1}

                niptype2        OBJECT IDENTIFIER ::= {nip 2}

                -- the Type1 group

                cfg                     OBJECT IDENTIFIER ::= {niptype1 1}

                stat            OBJECT IDENTIFIER ::= {niptype1 2}

                cfg2            OBJECT IDENTIFIER ::= {niptype1 11}

                usage           OBJECT IDENTIFIER ::= {niptype1 100}

                -- the Cfg2 group

                cfg2General                                     OBJECT IDENTIFIER ::= {cfg2 1}

                cfg2JobControl                          OBJECT IDENTIFIER ::= {cfg2 2}

                cfg2PaperHandling                       OBJECT IDENTIFIER ::= {cfg2 3}

                cfg2PrintProcessControl         OBJECT IDENTIFIER ::= {cfg2 4}

                cfg2HostInterface                       OBJECT IDENTIFIER ::= {cfg2 5}

                cfg2LocalResources                      OBJECT IDENTIFIER ::= {cfg2 6}

                cfg2Emulation                           OBJECT IDENTIFIER ::= {cfg2 7}

                cfg2Test                                        OBJECT IDENTIFIER ::= {cfg2 8}

                cfg2Menu                                        OBJECT IDENTIFIER ::= {cfg2 9}


                -- the Usage group

                usagePrinterUnit                        OBJECT IDENTIFIER ::= {usage 1}

                usageTray                                       OBJECT IDENTIFIER ::= {usage 2}

                usageToner                                      OBJECT IDENTIFIER ::= {usage 3}

                usageDrum                                       OBJECT IDENTIFIER ::= {usage 4}

                usageBelt                                       OBJECT IDENTIFIER ::= {usage 5}

                usageFuser                                      OBJECT IDENTIFIER ::= {usage 6}

                usageOil                                        OBJECT IDENTIFIER ::= {usage 7}

                usageWasteToner                         OBJECT IDENTIFIER ::= {usage 8}


                -- the Printserver group

      psVendor         OBJECT IDENTIFIER ::= { printserver 100 }
      okips            OBJECT IDENTIFIER ::= { printserver 683 }
      general          OBJECT IDENTIFIER ::= { okips 1 }
      commands         OBJECT IDENTIFIER ::= { okips 2 }
      okipsSNMP          OBJECT IDENTIFIER ::= { okips 3 }
      okipsSNMPCommands  OBJECT IDENTIFIER ::= { okipsSNMP 2 }
      okipsSNMPTrapMasks  OBJECT IDENTIFIER ::= { okipsSNMP 6 }
      driver           OBJECT IDENTIFIER ::= { okips 4 }
      tokenRing        OBJECT IDENTIFIER ::= { okips 5 }
      printServers     OBJECT IDENTIFIER ::= { okips 6 }
      psGeneral        OBJECT IDENTIFIER ::= { printServers 1 }
      psOutput         OBJECT IDENTIFIER ::= { printServers 2 }
      psProtocols      OBJECT IDENTIFIER ::= { printServers 3 }
      genProtocols     OBJECT IDENTIFIER ::= { general 15 }
      outputCommands   OBJECT IDENTIFIER ::= { psOutput 2 }
      outputConfigure  OBJECT IDENTIFIER ::= { psOutput 3 }
      outputJobLog     OBJECT IDENTIFIER ::= { psOutput 6 }
      trCommands       OBJECT IDENTIFIER ::= { tokenRing 2 }
      trConfigure      OBJECT IDENTIFIER ::= { tokenRing 3 }
      tcpip            OBJECT IDENTIFIER ::= { psProtocols 1 }
      netware          OBJECT IDENTIFIER ::= { psProtocols 2 }
      vines            OBJECT IDENTIFIER ::= { psProtocols 3 }
      lanManager       OBJECT IDENTIFIER ::= { psProtocols 4 }
      eTalk            OBJECT IDENTIFIER ::= { psProtocols 5 }
      tcpipCommands    OBJECT IDENTIFIER ::= { tcpip 3 }
      tcpipConfigure   OBJECT IDENTIFIER ::= { tcpip 4 }
      tcpipStatus      OBJECT IDENTIFIER ::= { tcpip 5 }
      nwCommands       OBJECT IDENTIFIER ::= { netware 3 }
      nwConfigure      OBJECT IDENTIFIER ::= { netware 4 }
      nwStatus         OBJECT IDENTIFIER ::= { netware 5 }
      bvCommands       OBJECT IDENTIFIER ::= { vines 3 }
      bvConfigure      OBJECT IDENTIFIER ::= { vines 4 }
      bvStatus         OBJECT IDENTIFIER ::= { vines 5 }
      eTalkCommands    OBJECT IDENTIFIER ::= { eTalk 3 }
      eTalkConfigure   OBJECT IDENTIFIER ::= { eTalk 4 }
      eTalkStatus      OBJECT IDENTIFIER ::= { eTalk 5 }

                
                -- the Cfg group

        cfgPersonality                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Printer language that is interpreted according to default
                     setting."
            ::= { cfg 20 }

        cfgManualFeed                           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Manual Feed Valid/Invalid"
            ::= { cfg 30 }

        cfgOkiPaperFeed                         OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Paper Tray"
            ::= { cfg 40 }                                                     

        cfgOkiAutoTraySwitch            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Auto Tray Switch Valid/Invalid"
            ::= { cfg 50 }

        cfgOkiPriorityTray            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                                        "Priority Tray Valid/Invalid"
            ::= { cfg 55 }

        cfgPaper                                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Edit size"
            ::= { cfg 60 }

        cfgOkiCustomPaperWidth      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Custom Paper Width(Only Japan)"
            ::= { cfg 61 }

        cfgOkiCustomPaperLength     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Custom Paper Length(Only Japan)"
            ::= { cfg 62 }                                                     

        cfgInTray2Size                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Size of media in Upper Tray.(This has no meaning to the
                     printer with the paper size auto-detecting function.)"
            ::= { cfg 70 }

        cfgInTray3Size                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Size of media in Lower Tray.(This has no meaning to the
                     printer with the paper size auto-detecting function.)"
            ::= { cfg 80 }                                                     

        cfgInTray5Size                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Size of media in Tray3.(This has no meaning to the
                     printer with the paper size auto-detecting function.)"
            ::= { cfg 90 }

        cfgInTray1Size                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Size of media loeded in Front Tray/Manual Feeder."
            ::= { cfg 100 }

        cfgInTray4Size                  OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Size of paper inserted in the multi-purpose Feeder."
            ::= { cfg 110 }

        cfgOkiMediaInTray2              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Types(Weight) of media loeded in Upper Tray."
            ::= { cfg 120 }                                                    

        cfgOkiMediaInTray3              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Types(Weight) of media loaded in Lower Tray."
            ::= { cfg 130 }

        cfgOkiMediaInTray5              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Types(Weight) of media loaded in Tray3."
            ::= { cfg 140 }

        cfgOkiMediaInTray1              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Types(Weight) of media loaded in Front Tray/Manual Feeder"
            ::= { cfg 150 }

        cfgOkiMediaInTray4              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Types(Weight) of media loaded in Multi-purpose Feeder"
            ::= { cfg 160 }                                                    

        cfgOkiPaperSizeCheck        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Paper Length Check valid/invalid"
            ::= { cfg 170 }

        cfgMptray                               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Returns the configuration value of the front tray"
            ::= { cfg 180 }

        cfgIntray1                              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Returns the auto-selection lock status for the front tray
                     (MP tray)"
            ::= { cfg 190 }

        cfgIntray2                              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Returns the auto-selection lock status for the standard
                     cassette"
            ::= { cfg 200 }                                                    

        cfgIntray3                              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Returns the auto-selection lock status for the optional
                     cassette"
            ::= { cfg 210 }

        cfgCopies                               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Number of Copies(1-999)"
            ::= { cfg 220 }

        cfgDuplex                               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Duplex valid/invalid"
            ::= { cfg 230 }

        cfgBinding                              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Binding Direction"
            ::= { cfg 240 }                                                    

        cfgPclFontSource                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Font Source"
            ::= { cfg 250 }

        cfgPclFontNumber                        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Font Number"
            ::= { cfg 260 }

        cfgPclPitch                             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Font Pitch (CPI)"
            ::= { cfg 270 }

        cfgPclPtSize                    OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Font Height (Point)"
            ::= { cfg 280 }                                                    

        cfgPclSymSet                            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Symbol Set"
            ::= { cfg 290 }

        cfgPclOkiA4PrintWidth       OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "How many columns are printed in A4 width (78 or 80
                     columns)"
            ::= { cfg 300 }

        cfgPclOkiWhitePageSkip      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Blank page print skip (OFF means No skip)"
            ::= { cfg 310 }

        cfgPclOkiCrFunction                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Function when CR is received
                     CR:CR only , CRLF:CR+LF"
            ::= { cfg 320 }                                                    

        cfgPclOkiLfFunction                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Function when LF is received
                     LF:LF only , LFCR:LF+CR"
            ::= { cfg 330 }

        cfgIbmpprCharacterPitch     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Character Pitch (CPI)"
            ::= { cfg 340 }

        cfgIbmpprFontCondense       OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "12CPI Pitch in Condense:
                      20:12cpi to 20cpi
                      12:12cpi to 12cpi"
            ::= { cfg 350 }

        cfgIbmpprCharacterSet       OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Character Set"
            ::= { cfg 360 }                                                    

        cfgIbmpprSymbolSet              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Symbol Set(Code Page)"
            ::= { cfg 370 }

        cfgIbmpprLetterOStyle       OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "O(Ou style)
                                                DISABLE :       
                                                ENABLE  :O with slash"
            ::= { cfg 380 }

        cfgIbmpprLinePitch              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Line per Inch (LPI)"
            ::= { cfg 390 }

        cfgIbmpprWhitePageSkip      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Blank page print skip (OFF means No skip)"
            ::= { cfg 400 }                                                    

        cfgIbmpprCrFunction             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Function upon receiving CR(Cursor CR)
                      CR:CR only , CRLF:CR+LF"
            ::= { cfg 410 }

        cfgIbmpprLfFunction             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Function upon receiving LF(Cursor LF)
                      LF:LF only , LFCR:LF+CR"
            ::= { cfg 420 }

        cfgIbmpprLineLength             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Number of characters in a line(columns)"
            ::= { cfg 430 }

        cfgIbmpprFormLength             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Paper length (Inches)
                      11:Letter , 11.7:A4 , 12:12inches"
            ::= { cfg 440 }                                                    

        cfgIbmpprTofPosition            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Print start position from top edge of paper(0-1.0)"
            ::= { cfg 450 }

        cfgIbmpprLeftMargine        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Left margin(0-1.0)"
            ::= { cfg 460 }

        cfgEpsonfxCharacterPitch        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Character Pitch (CPI)"
            ::= { cfg 470 }

        cfgEpsonfxCharacterSet      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Character Set"
            ::= { cfg 480 }                                                    

        cfgEpsonfxSymbolSet             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Symbol Set(Code Page)"
            ::= { cfg 490 }

        cfgEpsonfxLetterOStyle      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "0(Ou style)
                                                DISABLE :
                                                ENABLE  :O with slash"  
            ::= { cfg 500 }

        cfgEpsonfxLinePitch             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Line per Inch (LPI)"
            ::= { cfg 510 }

        cfgEpsonfxWhitePageSkip     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Blank page print skip (OFF means No skip)"
            ::= { cfg 520 }                                                    

        cfgEpsonfxCrFunction        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Function upon receiving CR(Cursor CR)
                      CR:CR only , CRLF:CR+LF"
            ::= { cfg 530 }

        cfgEpsonfxLineLength        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Number of characters in a line(columns)"
            ::= { cfg 540 }

        cfgEpsonfxFormLength        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Paper length (Inches)
                      11:Letter , 11.7:A4 , 12:12inches"
            ::= { cfg 550 }

        cfgEpsonfxTofPosition           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Print start position from top edge of paper (0-1.0)"
            ::= { cfg 560 }                                                    

        cfgEpsonfxLeftMargine           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Left margin(0-1.0)"
            ::= { cfg 570 }

        cfgHiperwOkiDensity             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Hiper-W Data Resolution"
            ::= { cfg 580 }

        cfgHiperwOkiFirstbit            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Data bit order"
            ::= { cfg 590 }

        cfgHiperwOkiReverse             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Posi/Nega Print"
            ::= { cfg 600 }                                                    

        cfgHiperwPrintSpeed             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Engine Print Speed"
            ::= { cfg 610 }

        cfgEscpKanjiFont            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Kanji Font(Only Japan)"
            ::= { cfg 611 }

        cfgEscpAnkFont              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Ank Font(Only Japan)"
            ::= { cfg 612 }

        cfgEscpCharacterSet         OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Character Set(Only Japan)"
            ::= { cfg 613 }

        cfgEscpZeroCharacter        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "O Character(Only Japan)"
            ::= { cfg 614 }                                                    

        cfgEscpZoom                 OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Zoom(Only Japan)"
            ::= { cfg 615 }

        cfgEscpTofPosition          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Tof Position(Only Japan)"
            ::= { cfg 616 }

        cfgEscpLineLength           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Line Length(Only Japan)"
            ::= { cfg 617 }

        cfgEscpCrFunction           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Cr Function(Only Japan)"
            ::= { cfg 618 }

        cfgEscpAutoLf               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Auto Lf(Only Japan)"
            ::= { cfg 619 }                                                    

        cfgOrientation                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Orientation"
            ::= { cfg 620 }

        cfgFormLines                    OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Lines per page"
            ::= { cfg 630 }                                                    

                cfgParallel                                     OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Parallel Interface valid/invalid"
                        ::= { cfg 640 }

                cfgRs232c                                       OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "RS232C valid/invalid"
                        ::= { cfg 650 }

                cfgRs422                                        OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "RS422 valid/invalid"
                        ::= { cfg 660 }

                cfgLocalTalk                            OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "LocalTalk valid/invalid"
                        ::= { cfg 670 }

                cfgNetwork                                      OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Network(OKIHSP) valid/invalid"
                        ::= { cfg 680 }

                cfgUsb                                  OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "USB valid/invalid"
                        ::= { cfg 690 }
        
        cfgResolution                   OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Print resolution"
            ::= { cfg 2000 }

        cfgRet                                  OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                "Smoothing(Oki Smoothing Technology)"
            ::= { cfg 2010 }

        cfgOkiRasterBuffer              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Raster Buffer size"
            ::= { cfg 2020 }

        cfgPageProtect                  OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Page Protection"
            ::= { cfg 2030 }                                                  

        cfgPrintProtect                 OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Print Protection"
            ::= { cfg 2035 }

        cfgOkiReceiveBuffer             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Receive Buffer size (KB)"
            ::= { cfg 2040 }

        cfgOkiFontProtection        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Font cache size
                      n*100KB"
            ::= { cfg 2050 }

        cfgOkiResourceSave                      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Resource save size
                      n*100KB"
            ::= { cfg 2060 }                                                 

        cfgAutoCont                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                "Auto continuation at error occurrence"
            ::= { cfg 2070 }                                                   

        cfgOkiAutoEject                 OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Paper eject at receive time-out(Sec)"
            ::= { cfg 2080 }                                                   

                cfgManualTimeOut                        OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Manual Insert timeout
                                                0:infinit,30:30sec,60:1min"
                        ::= { cfg 2090 }

        cfgDensity                              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Print darkness for mono printer"
            ::= { cfg 2100 }                                                   

                cfgOkiYellowDarkness            OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Yellow print darkness for color printer"
                        ::= { cfg 2101 }

                cfgOkiMagentaDarkness           OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Magenta print darkness for color printer"
                        ::= { cfg 2102 }

                cfgOkiCyanDarkness                      OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Cyan print darkness for color printer"
                ::= { cfg 2103 }

                cfgOkiBlackDarkness                     OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                "Black print darkness for color printer"
                        ::= { cfg 2104 }

                cfgOkiPowerSaving                       OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Time for shifting to Power Save Mode
                                          0:0Sec , 8:8Min"
                        ::= { cfg 2110 }

                cfgOkiQuietMode                         OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Quiet Mode
                                         ON:Default"
                        ::= { cfg 2115 }

        cfgLowToner                                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Off:shift to On-line in Toner Low state
                     On:remaining On-line"
            ::= { cfg 2120 }

        cfgEconoMode                    OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Toner saving"
            ::= { cfg 2130 }

        cfgClearableWarnings        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Handling of clearable warning
                                                JOB:Clearing by jobs"
            ::= { cfg 2140 }

        cfgOkiPrintErrors           OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Outputing report at error occurrence."
            ::= { cfg 2150 }                                                   

        cfgParallelSpeed                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Parallel I/F receiving speed"
            ::= { cfg 2160 }

        cfgBiDirection                  OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Bi-directional parallel"
            ::= { cfg 2170 }

        cfgOkiIPrime                    OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "I-Prime valid/invalid
                      On:valid"
            ::= { cfg 2180 }                                                   

                cfgLang                                         OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Local message language"
                        ::= { cfg 2190 }

        cfgOkiJobSwitch                         OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "Job Switch Timing"
            ::= { cfg 2195 }                                                   

                cfgRs232cBaud                           OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "RS232C Baud Rate"
                        ::= { cfg 2200 }

                cfgRs232cDataBits                       OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "RS232C Data Bit length"
                        ::= { cfg 2210 }

        cfgRs232cStopBits               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS232C Stop Bits"
            ::= { cfg 2215 }                                                   

                cfgRs232cParity                         OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "RS232C Parity"
                        ::= { cfg 2220 }

        cfgRs232cBusyTime               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS232C Minimum Busy time"
            ::= { cfg 2230 }                                                   

        cfgRs232cFlowControl            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                                        "RS232C Flow Control"
            ::= { cfg 2240 }                                                   

        cfgRs422Baud                            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS422 Baud Rate"
            ::= { cfg 2300 }                                                   

        cfgRs422DataBits            OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS422 Data Bit length"
            ::= { cfg 2310 }                                                  

                cfgRs422StopBits                        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS422 stop bits"
            ::= { cfg 2320 }                                                   

        cfgRs422Parity                          OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "RS422 Parity"
            ::= { cfg 2330 }                                                   


        cfgOkiUser      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    " User"
            ::= { cfg 3000 }

        cfgOkiEcp      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                                        "ECP mode Setting(User Maintenance)"
            ::= { cfg 3005 }

        cfgOkiXAdjust      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    "X Adjust Value(User Maintenance)"
            ::= { cfg 3010 }

        cfgOkiYAdjust      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    "Y Adjust Value(User Maintenance)"
            ::= { cfg 3020 }

                cfgOkiDuplexAdjust                      OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                "Duplex Position Adjust Value"
                        ::= { cfg 3022 }                                                   

        cfgOkiMediaSourceTray2      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    "Feeding destination of 2nd tray in PCL5 Emulation
                                        (User Maintenance)"
            ::= { cfg 3024 }

        cfgOkiMediaSourceTray3      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    "Feeding destination of 3rd tray in PCL5 Emulation
                                        (User Maintenance)"
            ::= { cfg 3025 }

        cfgOkiMediaSourceFront      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                    "Feeding destination of Front tray in PCL5 Emulation
                                        (User Maintenance)"
            ::= { cfg 3026 }

        cfgPlacePage                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                    "The mechanical sheet setting position(User Maintenance)"
            ::= { cfg 3028 }

                cfgOkiColorAdjustPrint          OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  write-only
                        STATUS  optional
                        DESCRIPTION
                                        "Print position Adjustment for color printer"
                        ::= { cfg 3041 }

                cfgOkiColorAdjustYellow         OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  write-only
                        STATUS  optional
                        DESCRIPTION
                                        "Yellow print position Adjustment for color printer
                                                Value: Left, Center, Right ; Range: -7 to 7"
                        ::= { cfg 3042 }

                cfgOkiColorAdjustMagenta        OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  write-only
                        STATUS  optional
                        DESCRIPTION
                                        "Magenta print position Adjustment for color printer
                                                Value: Left, Center, Right ; Range: -7 to 7"
                        ::= { cfg 3043 }

                cfgOkiColorAdjustCyan           OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  write-only
                        STATUS  optional
                        DESCRIPTION
                                        "Cyan print position Adjustment for color printer
                                                Value: Left, Center, Right ; Range: -7 to 7"
                        ::= { cfg 3044 }

        cfgOkiJamRecovery      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-write
                        STATUS  optional
            DESCRIPTION
                                        "Jam Recovery Mode(User Maintenance)"
                        ::= { cfg 3142 }

                cfgFirmCpuVersion                       OBJECT-TYPE
                        SYNTAX  DisplayString(SIZE (0..20))
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Firmware Version
                                                ex. FW = 01.00 A00 C745
                                                        (F/W ver . User . CPU ver)"
                        ::= { cfg 3160 }

        cfgEngineFirmVersion        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Engine Version
                     ex. ENG = 01.00"
            ::= { cfg 3170 }

        cfgMessageVersion               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Local Message Version
                     ex. MSG = L01.00,P01.20"
            ::= { cfg 3180 }

        cfgPclFirmVersion               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "PCL5e Version"
            ::= { cfg 3190 }                                                   

        cfgPclxlFirmVersion             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "PCL-XL Version"
            ::= { cfg 3200 }

        cfgSidmFirmVersion              OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "SIDM Version"
            ::= { cfg 3210 }

        cfgHdFirmVersion                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Hex dump Version"
            ::= { cfg 3220 }

        cfgPsFirmVersion                        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "PostScript Version"
            ::= { cfg 3230 }                                                   

        cfgEmulationTable               OBJECT-TYPE
            SYNTAX  SEQUENCE OF CfgEmulationEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "Installed emulation name table"
            ::= { cfg 3500 }

        cfgEmulationEntry               OBJECT-TYPE
            SYNTAX  CfgEmulationEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "Installed emulation name entry"
            INDEX   {cfgEmulationIndex }
            ::= { cfgEmulationTable 1 }

        CfgEmulationEntry ::= SEQUENCE{
        cfgEmulationIndex   INTEGER(1..100),
        cfgEmulationName    DisplayString(SIZE (0..20))
        }

        cfgEmulationIndex               OBJECT-TYPE
            SYNTAX  INTEGER(1..100)
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Installed emulation name index"
            ::= { cfgEmulationEntry 1 }                                        

        cfgEmulationName                OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Installed emulation name"
            ::= { cfgEmulationEntry 2 }

        cfgRamInstalledSize             OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Installed RAM size"
            ::= { cfg 3510 }

        cfgTrayTable                    OBJECT-TYPE
            SYNTAX  SEQUENCE OF CfgTrayEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "Installed tray name table"
            ::= {cfg 3520 }

        cfgTrayEntry                    OBJECT-TYPE
            SYNTAX  CfgTrayEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "Installed tray name entry"
            ::= { cfgTrayTable 1 }                                             

        CfgTrayEntry        ::= SEQUENCE{
            cfgTrayIndex    INTEGER(0..100),
            cfgTrayName     DisplayString(SIZE (0..20))
        }

        cfgTrayIndex                    OBJECT-TYPE
            SYNTAX  INTEGER(0..100)
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Installed tray name index"
            ::= { cfgTrayEntry 1 }

        cfgTrayName                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Installed tray name"
            ::= { cfgTrayEntry 2 }

        cfgPrinterName                  OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..20))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Printer model name"
            ::= { cfg 3530 }                                                   


        -- the stat group

        stPjlStatus                     OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "PJL Status Code (Refer to the System Spec PJL Version for
                     codes.)"
            ::= { stat 10 }                                                    

        stLcdMessage                    OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..40))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Character strings displayed on LCD. An extension of
                                                Roman-8 applies to Symbol Set."
            ::= { stat 20 }

        stOnline                        OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "Host Interface's on-line state
                      TRUE:ON-LINE , FALSE:OFF-LINE"
            ::= { stat 30 }

        stManualLedStatus               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "MANUAL LED status on front panel."
            ::= { stat 100 }

        stOperatorLedStatus         OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "OPERATOR LED status on front panel."
            ::= { stat 110 }                                                   

        stServiceLedStatus                      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "SERVICE LED status on front panel."
            ::= { stat 120 }

        stOnlineLedStatus               OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..30))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "ON-LINE LED status on front panel.)"
            ::= { stat 130 }

        stPsStatus                                      OBJECT-TYPE
            SYNTAX  DisplayString(SIZE (0..100))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "PS message same as when the printer receives ^T(CTR-T)"
            ::= { stat 140 }                                                   
        
        -- the cfg2General group

                cfg2PrinterInformation          OBJECT IDENTIFIER ::= {cfg2General 10}

                cfg2PrinterConsumption          OBJECT IDENTIFIER ::= {cfg2General 20}

                cfg2JamRecovery                         OBJECT IDENTIFIER ::= {cfg2General 70}


                cfg2JamRecoveryCurrentValue                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Jam recovery setting"
                ::= { cfg2JamRecovery 2 }



                cfg2OPPanelLock                         OBJECT IDENTIFIER ::= {cfg2General 130}

                cfg2OPPanelLockCurrentValue                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Operation Panel setting"
                ::= { cfg2OPPanelLock 2 }

                cfg2Controlt                         OBJECT IDENTIFIER ::= {cfg2General 160}

                cfg2ControltCurrentValue                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Control T setting"
                ::= { cfg2Controlt 2 }


                cfg2Type1MIBVersion                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Type1 MIB Version"
                ::= { cfg2PrinterInformation 10 }

                cfg2ModelId                                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Model ID"
                ::= { cfg2PrinterInformation 30 }


                cfg2PrinterVersions                                     OBJECT IDENTIFIER ::= {cfg2PrinterInformation 50}

                cfg2PrinterVersion1Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 1}
                cfg2PrinterVersion2Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 2}
                cfg2PrinterVersion3Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 3}
                cfg2PrinterVersion4Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 4}
                cfg2PrinterVersion5Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 5}
                cfg2PrinterVersion6Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 6}
                cfg2PrinterVersion7Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 7}
                cfg2PrinterVersion8Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 8}
                cfg2PrinterVersion9Table                        OBJECT IDENTIFIER ::= {cfg2PrinterVersions 9}
                cfg2PrinterVersion10Table                       OBJECT IDENTIFIER ::= {cfg2PrinterVersions 10}


--              cfg2PrinterVersion1Table                                        OBJECT-TYPE
--                      SYNTAX  Cfg2PrinterVersion1Table
--                      ACCESS  not-accessible
--                      STATUS  optional
--                      DESCRIPTION
--                                      "Printer Version1"
--              ::= { cfg2PrinterVersions 1 }

--              Cfg2PrinterVersion1 ::= SEQUENCE{
--                      cfg2PrinterVersion1Description                  DisplayString,
--                      cfg2PrinterVersion1                                             DisplayString
--              }

--              cfg2PrinterVersion1Description                          OBJECT-TYPE
--                      SYNTAX  DisplayString
--                      ACCESS  read-only
--                      STATUS  optional
--                      DESCRIPTION
--                                      "Printer Version1 Description"
--              ::= { cfg2PrinterVersion1 1 }

                cfg2PrinterVersion1                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version1"
                ::= { cfg2PrinterVersion1Table 2 }

                cfg2PrinterVersion2                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version2"
                ::= { cfg2PrinterVersion2Table 2 }

                cfg2PrinterVersion3                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version3"
                ::= { cfg2PrinterVersion3Table 2 }

                cfg2PrinterVersion4                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version4"
                ::= { cfg2PrinterVersion4Table 2 }

                cfg2PrinterVersion5                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version5"
                ::= { cfg2PrinterVersion5Table 2 }

                cfg2PrinterVersion6                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version6"
                ::= { cfg2PrinterVersion6Table 2 }

                cfg2PrinterVersion7                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version7"
                ::= { cfg2PrinterVersion7Table 2 }

                cfg2PrinterVersion8                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version8"
                ::= { cfg2PrinterVersion8Table 2 }

                cfg2PrinterVersion9                                                     OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version9"
                ::= { cfg2PrinterVersion9Table 2 }

                cfg2PrinterVersion10                                                    OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Version10"
                ::= { cfg2PrinterVersion10Table 2 }

                cfg2PrinterType                                                                 OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "Printer Type"
                ::= { cfg2PrinterInformation 70 }


                cfg2PowerSave           OBJECT IDENTIFIER ::= {cfg2PrinterConsumption 10}

                cfg2PowerSaveCurrentValue                                               OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "PowerSave setting"
                ::= { cfg2PowerSave 2 }

                cfg2PowerSaveShift      OBJECT IDENTIFIER ::= {cfg2PrinterConsumption 11}

                cfg2PowerSaveShiftCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "PowerSave Shift setting"
                ::= { cfg2PowerSaveShift 2 }


                -- the cfg2JobControl group


                -- the cfg2PaperHandling group

                cfg2PHCommon                    OBJECT IDENTIFIER ::= {cfg2PaperHandling 1}
                cfg2PHInput                             OBJECT IDENTIFIER ::= {cfg2PaperHandling 2}
                cfg2PHOutput                    OBJECT IDENTIFIER ::= {cfg2PaperHandling 3}
                cfg2PHDuplex                    OBJECT IDENTIFIER ::= {cfg2PaperHandling 4}


                cfg2MonoPrintSpeed              OBJECT IDENTIFIER ::= {cfg2PHCommon 20}

                cfg2MonoPrintSpeedCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Mono Print Speed setting"
                ::= { cfg2MonoPrintSpeed 2 }


                cfg2PriorityTray                OBJECT IDENTIFIER ::= {cfg2PHInput 30}

                cfg2PriorityTrayCurrentValue                                    OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Priority Tray setting"
                ::= { cfg2PriorityTray 2 }


                cfg2TrayTable                   OBJECT IDENTIFIER ::= {cfg2PHInput 40}

                cfg2Tray1Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 1}
                cfg2Tray2Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 2}
                cfg2Tray3Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 3}
                cfg2Tray4Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 4}
                cfg2Tray5Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 5}
                cfg2Tray6Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 6}
                cfg2Tray7Table                  OBJECT IDENTIFIER ::= {cfg2TrayTable 7}

                cfg2Tray1PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray1Table 1}
                cfg2Tray2PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray2Table 1}
                cfg2Tray3PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray3Table 1}
                cfg2Tray4PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray4Table 1}
                cfg2Tray5PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray5Table 1}
                cfg2Tray6PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray6Table 1}
                cfg2Tray7PaperSize              OBJECT IDENTIFIER ::= {cfg2Tray7Table 1}

                cfg2Tray1PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 Paper Size setting"
                ::= { cfg2Tray1PaperSize 2 }

                cfg2Tray2PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 Paper Size setting"
                ::= { cfg2Tray2PaperSize 2 }

                cfg2Tray3PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 Paper Size setting"
                ::= { cfg2Tray3PaperSize 2 }

                cfg2Tray4PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 Paper Size setting"
                ::= { cfg2Tray4PaperSize 2 }

                cfg2Tray5PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 Paper Size setting"
                ::= { cfg2Tray5PaperSize 2 }

                cfg2Tray6PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 Paper Size setting"
                ::= { cfg2Tray6PaperSize 2 }

                cfg2Tray7PaperSizeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 Paper Size setting"
                ::= { cfg2Tray7PaperSize 2 }


                cfg2Tray1MediaType              OBJECT IDENTIFIER ::= {cfg2Tray1Table 2}
                cfg2Tray2MediaType              OBJECT IDENTIFIER ::= {cfg2Tray2Table 2}
                cfg2Tray3MediaType              OBJECT IDENTIFIER ::= {cfg2Tray3Table 2}
                cfg2Tray4MediaType              OBJECT IDENTIFIER ::= {cfg2Tray4Table 2}
                cfg2Tray5MediaType              OBJECT IDENTIFIER ::= {cfg2Tray5Table 2}
                cfg2Tray6MediaType              OBJECT IDENTIFIER ::= {cfg2Tray6Table 2}
                cfg2Tray7MediaType              OBJECT IDENTIFIER ::= {cfg2Tray7Table 2}

                cfg2Tray1MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 Media Type setting"
                ::= { cfg2Tray1MediaType 2 }

                cfg2Tray2MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 Media Type setting"
                ::= { cfg2Tray2MediaType 2 }

                cfg2Tray3MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 Media Type setting"
                ::= { cfg2Tray3MediaType 2 }

                cfg2Tray4MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 Media Type setting"
                ::= { cfg2Tray4MediaType 2 }

                cfg2Tray5MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 Media Type setting"
                ::= { cfg2Tray5MediaType 2 }

                cfg2Tray6MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 Media Type setting"
                ::= { cfg2Tray6MediaType 2 }

                cfg2Tray7MediaTypeCurrentValue                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 Media Type setting"
                ::= { cfg2Tray7MediaType 2 }


                cfg2Tray1MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray1Table 3}
                cfg2Tray2MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray2Table 3}
                cfg2Tray3MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray3Table 3}
                cfg2Tray4MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray4Table 3}
                cfg2Tray5MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray5Table 3}
                cfg2Tray6MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray6Table 3}
                cfg2Tray7MediaWeight    OBJECT IDENTIFIER ::= {cfg2Tray7Table 3}

                cfg2Tray1MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 Media Weight setting"
                ::= { cfg2Tray1MediaWeight 2 }

                cfg2Tray2MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 Media Weight setting"
                ::= { cfg2Tray2MediaWeight 2 }

                cfg2Tray3MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 Media Weight setting"
                ::= { cfg2Tray3MediaWeight 2 }

                cfg2Tray4MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 Media Weight setting"
                ::= { cfg2Tray4MediaWeight 2 }

                cfg2Tray5MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 Media Weight setting"
                ::= { cfg2Tray5MediaWeight 2 }

                cfg2Tray6MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 Media Weight setting"
                ::= { cfg2Tray6MediaWeight 2 }

                cfg2Tray7MediaWeightCurrentValue                                        OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 Media Weight setting"
                ::= { cfg2Tray7MediaWeight 2 }


                cfg2UnitOfMeasure               OBJECT IDENTIFIER ::= {cfg2PHInput 50}

                cfg2UnitOfMeasureCurrentValue                                           OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Unit of Measure setting"
                ::= { cfg2UnitOfMeasure 2 }


                cfg2XDimension                  OBJECT IDENTIFIER ::= {cfg2PHInput 60}

                cfg2XDimensionCurrentValue                                                      OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "X Dimension setting"
                ::= { cfg2XDimension 2 }


                cfg2YDimension                  OBJECT IDENTIFIER ::= {cfg2PHInput 70}

                cfg2YDimensionCurrentValue                                                      OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Y Dimension setting"
                ::= { cfg2YDimension 2 }


                cfg2TrayA3Paper                 OBJECT IDENTIFIER ::= {cfg2PHInput 90}

                cfg2Tray1A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 1}
                cfg2Tray2A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 2}
                cfg2Tray3A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 3}
                cfg2Tray4A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 4}
                cfg2Tray5A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 5}
                cfg2Tray6A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 6}
                cfg2Tray7A3Paper                OBJECT IDENTIFIER ::= {cfg2TrayA3Paper 7}

                cfg2Tray1A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 A3 Paper setting"
                ::= { cfg2Tray1A3Paper 2 }

                cfg2Tray2A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 A3 Paper setting"
                ::= { cfg2Tray2A3Paper 2 }

                cfg2Tray3A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 A3 Paper setting"
                ::= { cfg2Tray3A3Paper 2 }

                cfg2Tray4A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 A3 Paper setting"
                ::= { cfg2Tray4A3Paper 2 }

                cfg2Tray5A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 A3 Paper setting"
                ::= { cfg2Tray5A3Paper 2 }

                cfg2Tray6A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 A3 Paper setting"
                ::= { cfg2Tray6A3Paper 2 }

                cfg2Tray7A3PaperCurrentValue                                            OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 A3 Paper setting"
                ::= { cfg2Tray7A3Paper 2 }


                cfg2TrayLegal14Paper            OBJECT IDENTIFIER ::= {cfg2PHInput 100}

                cfg2Tray1Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 1}
                cfg2Tray2Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 2}
                cfg2Tray3Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 3}
                cfg2Tray4Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 4}
                cfg2Tray5Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 5}
                cfg2Tray6Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 6}
                cfg2Tray7Legal14Paper   OBJECT IDENTIFIER ::= {cfg2TrayLegal14Paper 7}

                cfg2Tray1Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 Legal14 Paper setting"
                ::= { cfg2Tray1Legal14Paper 2 }

                cfg2Tray2Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 Legal14 Paper setting"
                ::= { cfg2Tray2Legal14Paper 2 }

                cfg2Tray3Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 Legal14 Paper setting"
                ::= { cfg2Tray3Legal14Paper 2 }

                cfg2Tray4Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 Legal14 Paper setting"
                ::= { cfg2Tray4Legal14Paper 2 }

                cfg2Tray5Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 Legal14 Paper setting"
                ::= { cfg2Tray5Legal14Paper 2 }

                cfg2Tray6Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 Legal14 Paper setting"
                ::= { cfg2Tray6Legal14Paper 2 }

                cfg2Tray7Legal14PaperCurrentValue                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 Legal14 Paper setting"
                ::= { cfg2Tray7Legal14Paper 2 }


                cfg2TrayA5A6Paper               OBJECT IDENTIFIER ::= {cfg2PHInput 110}

                cfg2Tray1A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 1}
                cfg2Tray2A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 2}
                cfg2Tray3A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 3}
                cfg2Tray4A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 4}
                cfg2Tray5A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 5}
                cfg2Tray6A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 6}
                cfg2Tray7A5A6Paper              OBJECT IDENTIFIER ::= {cfg2TrayA5A6Paper 7}

                cfg2Tray1A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray1 A5/A6 Paper setting"
                ::= { cfg2Tray1A5A6Paper 2 }

                cfg2Tray2A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray2 A5/A6 Paper setting"
                ::= { cfg2Tray2A5A6Paper 2 }

                cfg2Tray3A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray3 A5/A6 Paper setting"
                ::= { cfg2Tray3A5A6Paper 2 }

                cfg2Tray4A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray4 A5/A6 Paper setting"
                ::= { cfg2Tray4A5A6Paper 2 }

                cfg2Tray5A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray5 A5/A6 Paper setting"
                ::= { cfg2Tray5A5A6Paper 2 }

                cfg2Tray6A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray6 A5/A6 Paper setting"
                ::= { cfg2Tray6A5A6Paper 2 }

                cfg2Tray7A5A6PaperCurrentValue                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Tray7 A5/A6 Paper setting"
                ::= { cfg2Tray7A5A6Paper 2 }


                cfg2OutputBin           OBJECT IDENTIFIER ::= {cfg2PHOutput 10}

                cfg2OutputBinCurrentValue                                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Output Bin setting"
                ::= { cfg2OutputBin 2 }


                cfg2Duplex                      OBJECT IDENTIFIER ::= {cfg2PHDuplex 10}

                cfg2DuplexCurrentValue                                                          OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Duplex setting"
                ::= { cfg2Duplex 2 }

                cfg2Binding                     OBJECT IDENTIFIER ::= {cfg2PHDuplex 20}

                cfg2BindingCurrentValue                                                         OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Binding setting"
                ::= { cfg2Binding 2 }



                -- the cfg2PrintProcessControl group

                cfg2PPCColor                            OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 1}
                cfg2PPCDevelopmentControl       OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 2}
                cfg2PPCLEDHeadControl           OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 3}
                cfg2PPCFusingControl            OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 4}
                cfg2PPCPrintPositionControl     OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 5}
                cfg2PPCTonerControl                     OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 6}
                cfg2PPCDrumControl                      OBJECT IDENTIFIER ::= {cfg2PrintProcessControl 7}


                cfg2AutoRegistration   OBJECT IDENTIFIER ::= {cfg2PPCColor 30}

                cfg2AutoRegistrationCurrentValue                                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Auto Registration setting"
                ::= { cfg2AutoRegistration 2 }
                
                cfg2JobOffset   OBJECT IDENTIFIER ::= {cfg2PPCDevelopmentControl 20}

                cfg2JobOffsetCurrentValue                                                       OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-write
                        STATUS  optional
                        DESCRIPTION
                                        "Job Offset setting"
                ::= { cfg2JobOffset 2 }


                -- the cfg2HostInterface group

                -- the cfg2LocalResources group

                cfg2LRCommon    OBJECT IDENTIFIER ::= {cfg2LocalResources 1}

                cfg2LRMemory    OBJECT IDENTIFIER ::= {cfg2LocalResources 2}

                cfg2LRHdd               OBJECT IDENTIFIER ::= {cfg2LocalResources 3}


                cfg2StoragePartitionTable                               OBJECT-TYPE
                        SYNTAX  SEQUENCE OF Cfg2StoragePartitionEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "storage partition table"
                ::= { cfg2LRCommon 1 }

                cfg2StoragePartitionEntry                               OBJECT-TYPE
                        SYNTAX  Cfg2StoragePartitionEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "storage partition entry"
--                      INDEX   {cfg2StoragePartitionIndex }
                        INDEX   {hrDeviceIndex , hrPartitionIndex}
                ::= { cfg2StoragePartitionTable 1 }

                Cfg2StoragePartitionEntry ::= SEQUENCE{
                        cfg2StoragePartitionIndex                       INTEGER,
                        cfg2StoragePartitionFree                        INTEGER
                }

                cfg2StoragePartitionIndex                               OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "storage partition index"
                ::= { cfg2StoragePartitionEntry 1 }

                cfg2StoragePartitionFree                                OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "storage partition free size"
                ::= { cfg2StoragePartitionEntry 2 }



                -- the cfg2Emulation group

                -- the cfg2Test group

                -- the cfg2Menu group



        usagePrinterUnitTable                           OBJECT-TYPE
            SYNTAX  SEQUENCE OF UsagePrinterUnitEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage PrinterUnit table"
                ::= { usagePrinterUnit 1 }

        usagePrinterUnitEntry                           OBJECT-TYPE
            SYNTAX  UsagePrinterUnitEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage PrinterUnit entry"
            INDEX   {usagePrinterUnitIndex }
                ::= { usagePrinterUnitTable 1 }

        UsagePrinterUnitEntry ::= SEQUENCE{
            usagePrinterUnitIndex                       INTEGER,
            usagePrinterUnitCounter                     DisplayString,
            usagePrinterUnitCounterLife                 DisplayString}

        usagePrinterUnitIndex                                   OBJECT-TYPE
               SYNTAX  INTEGER
               ACCESS  read-only
               STATUS  optional
               DESCRIPTION
                               "usage PrinterUnit index"
               ::= { usagePrinterUnitEntry 1 }


        usagePrinterUnitCounter                         OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage PrinterUnit Counter"
                ::= { usagePrinterUnitEntry 3 }

        usagePrinterUnitCounterLife                     OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage PrinterUnit Counter Life"
                ::= { usagePrinterUnitEntry 4 }

        usageTrayTable                                          OBJECT-TYPE
            SYNTAX  SEQUENCE OF UsageTrayEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage Tray table"
                ::= { usageTray 1 }

        usageTrayEntry                                          OBJECT-TYPE
            SYNTAX  UsageTrayEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage Tray entry"
            INDEX   {usageTrayIndex }
                ::= { usageTrayTable 1 }

        UsageTrayEntry ::= SEQUENCE{
            usageTrayIndex                                      INTEGER,
        --    usageTrayCurrentLevel                     DisplayString,
            usageTrayMaxLevel                           DisplayString,
            usageTrayCounter                          DisplayString
        }

                usageTrayIndex                                                  OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Tray index"
                ::= { usageTrayEntry 1 }

        usageTrayMaxLevel                                       OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Tray Max Level"
                ::= { usageTrayEntry 4 }


        usageTrayCounter                                      OBJECT-TYPE
            SYNTAX    DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Tray Counter"
                ::= { usageTrayEntry 7 }



        usageTonerTable                                         OBJECT-TYPE
            SYNTAX  SEQUENCE OF UsageTonerEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage Toner table"
                ::= { usageToner 1 }

        usageTonerEntry                                         OBJECT-TYPE
            SYNTAX  UsageTonerEntry
            ACCESS  not-accessible
            STATUS  optional
            DESCRIPTION
                    "usage Toner entry"
            INDEX   {usageTonerIndex }
                ::= { usageTonerTable 1 }

        UsageTonerEntry ::= SEQUENCE{
            usageTonerIndex                                     INTEGER,
            usageTonerDescription                       DisplayString,
            usageTonerCurrentLevel                      DisplayString,
            usageTonerMaxLevel                          DisplayString,
            usageTonerLevelUnit                         DisplayString
        }

                usageTonerIndex                                                 OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Toner index"
                ::= { usageTonerEntry 1 }

        usageTonerDescription                           OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Toner Description"
                ::= { usageTonerEntry 2 }

        usageTonerCurrentLevel                          OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Toner Current Level"
                ::= { usageTonerEntry 3 }

        usageTonerMaxLevel                                      OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Toner Max Level"
                ::= { usageTonerEntry 4 }

        usageTonerLevelUnit                                     OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                    "usage Toner Level Unit"
                ::= { usageTonerEntry 5 }



                usageDrumTable                                                  OBJECT-TYPE
                        SYNTAX  SEQUENCE OF UsageDrumEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Drum table"
                ::= { usageDrum 1 }

                usageDrumEntry                                                  OBJECT-TYPE
                        SYNTAX  UsageDrumEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Drum entry"
                        INDEX   {usageDrumIndex }
                ::= { usageDrumTable 1 }

                UsageDrumEntry ::= SEQUENCE{
                        usageDrumIndex                                  INTEGER,
                        usageDrumCurrentLevel                   DisplayString,
                        usageDrumMaxLevel                               DisplayString
                }

                usageDrumIndex                                                  OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Drum index"
                ::= { usageDrumEntry 1 }


                usageDrumCurrentLevel                                   OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Drum Current Level"
                ::= { usageDrumEntry 3 }

                usageDrumMaxLevel                                               OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Drum Max Level"
                ::= { usageDrumEntry 4 }

                usageBeltTable                                                  OBJECT-TYPE
                        SYNTAX  SEQUENCE OF UsageBeltEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Belt table"
                ::= { usageBelt 1 }

                usageBeltEntry                                                  OBJECT-TYPE
                        SYNTAX  UsageBeltEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Belt entry"
                        INDEX   {usageBeltIndex }
                ::= { usageBeltTable 1 }

                UsageBeltEntry ::= SEQUENCE{
                        usageBeltIndex                                  INTEGER,
                        usageBeltCurrentLevel                   DisplayString,
                        usageBeltMaxLevel                               DisplayString
                }

                usageBeltIndex                                                  OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Belt index"
                ::= { usageBeltEntry 1 }


                usageBeltCurrentLevel                                   OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Belt Current Level"
                ::= { usageBeltEntry 3 }

                usageBeltMaxLevel                                               OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Belt Max Level"
                ::= { usageBeltEntry 4 }

                usageFuserTable                                                 OBJECT-TYPE
                        SYNTAX  SEQUENCE OF UsageFuserEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Fuser table"
                ::= { usageFuser 1 }

                usageFuserEntry                                                 OBJECT-TYPE
                        SYNTAX  UsageFuserEntry
                        ACCESS  not-accessible
                        STATUS  optional
                        DESCRIPTION
                                        "usage Fuser entry"
                        INDEX   {usageFuserIndex }
                ::= { usageFuserTable 1 }

                UsageFuserEntry ::= SEQUENCE{
                        usageFuserIndex                                 INTEGER,
                        usageFuserCurrentLevel                  DisplayString,
                        usageFuserMaxLevel                              DisplayString
                }

                usageFuserIndex                                                 OBJECT-TYPE
                        SYNTAX  INTEGER
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Fuser index"
                ::= { usageFuserEntry 1 }

                usageFuserCurrentLevel                                  OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Fuser Current Level"
                ::= { usageFuserEntry 3 }

                usageFuserMaxLevel                                              OBJECT-TYPE
                        SYNTAX  DisplayString
                        ACCESS  read-only
                        STATUS  optional
                        DESCRIPTION
                                        "usage Fuser Max Level"
                ::= { usageFuserEntry 4 }


        -- The print server group
        
        psVendorId  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The vendor ID branch."
            ::= { psVendor 1 }
        
        psMibVersion OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..9))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A textual description of the MIB Version."
            ::= { psVendor 3 }

        genGroupVersion     OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the general group."
            ::= { general 1 }
        
        genMIBVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version of the MIB."
            ::= { general 2 }
        
        genProductName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..22))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A textual description of the device."
            ::= { general 3 }
        
        genProductNumber OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..5))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The product number of the device."
            ::= { general 4 }
        
        genSerialNumber OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..7))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The serial number of the device."
            ::= { general 5 }
        
        genHWAddress OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (6))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The device's hardware address."
            ::= { general 6 }
        
        genCableType OBJECT-TYPE
            SYNTAX  INTEGER {
                tenbase2(1),
                tenbaseT(2),
                aui(3),
                utp(4),
                stp(5),
                fiber100fx(6)
            }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Indicates the network cable type connected to the
                 device."
            ::= { general 7 }
        
        genDateCode OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..10))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The device's datecode."
            ::= { general 8 }
        
        genVersion OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..10))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the version of the firmware."
            ::= { general 9 }
        
        genConfigurationDirty OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A variable's value has been changed which will
                 require that the device be reset or power cycled
                 before it will take effect.
                 Set cmdReset to take this action.
        
                 A list of critical variables that will cause
                 genConfigurationDirty to be set follows:
        
                 snmpGetCommunityName,
                 snmpSetCommunityName,
        
                 trPriority,
                 trEarlyTokenRelease,
                 trPacketSize,
                 trRouting,
                 trLocallyAdminAddr,
        
                 psJetAdminEnabled,
        
                 outputType,
                 outputHandshake,
        
                 tcpipEnabled,
                 tcpipIPAddress,
                 tcpipDefaultGateway,
                 tcpipSubnetMask,
                 tcpipUsingNetProtocols,
                 tcpipBootProtocolsEnabled,
                 tcpipRawPortNumber,
                 tcpipMLPTCPPort,
                 tcpipMLPPort,
        
                 nwEnabled,
                 nwSetFrameFormat,
                 nwMode,
                 nwPrintServerName,
                 nwPrintServerPassword,
                 nwQueueScanTime,
                 nwFileServerName,
                 nwPortPrinterNumber,
                 nwPortFontDownload,
                 nwPortPCLQueue,
                 nwPortPSQueue,
                 nwPortFormsOn,
                 nwPortNotification,
        
                 bvEnabled,
                 bvSetSequencedRouting,
                 bvLoginName,
                 bvLoginPassword,
                 bvPrintServiceName,
                 bvPrintServiceRouting,
        
                 lmEnabled,
        
                 eTalkEnabled"
            ::= { general 10 }
        
        genCompanyName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..30))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the manufacturer of the device."
            ::= { general 11 }
        
        genCompanyLoc OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..50))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the location of the manufacturer
                 of the device."
            ::= { general 12 }
        
        genCompanyPhone OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..15))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the phone number of the
                 manufacturer of the device."
            ::= { general 13 }
        
        genCompanyTechSupport OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..64))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the technical support information
                 for the device."
            ::= { general 14 }
        
        genNumProtocols OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of network protocols supported on the
                 device."
            ::= { genProtocols 1 }
        
        genProtocolTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF GenProtocolEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A list of network protocols.  The number of
                 entries is given by the value of genNumProtocols."
           ::= { genProtocols 2 }
        
        genProtocolEntry OBJECT-TYPE
            SYNTAX  GenProtocolEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A network protocol supported on the device."
            INDEX   { genProtocolIndex }
            ::= { genProtocolTable 1 }
        
        GenProtocolEntry ::=
            SEQUENCE {
                genProtocolIndex
                    INTEGER,
                genProtocolDescr
                    DisplayString,
                genProtocolID
                    INTEGER
            }
        
        genProtocolIndex OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A unique value for each network protocol.  Its
                 value ranges between 1 and the value of
                 genNumProtocols.  The value for each protocol must
                 remain constant at least from one re-initialization
                 of the entity's network management system to the next
                 re-initialization."
            ::= { genProtocolEntry 1 }
        
        genProtocolDescr OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..32))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A textual string describing the network protocol."
            ::= { genProtocolEntry 2 }
        
        genProtocolID OBJECT-TYPE
            SYNTAX  INTEGER {
                tcp-ip(1),
                netware(2),
                vines(3),
                lanmanger(4),
                ethertalk(5)
            }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A unique identification number for the network
                 protocol."
            ::= { genProtocolEntry 3 }

       genSysUpTimeString OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..35))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
               "A string indicating the system up time for the device."
            ::= { general 16 }
        
        -- the commands group
        
        cmdGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the commands group."
        ::= { commands 1 }
        
        cmdReset OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will reset the device.  The following
                 list of variables will also cause the device to reset
                 itself.
        
                 cmdRestoreDefaults,
                 snmpRestoreDefaults,
                 trRestoreDefaults,
                 outputRestoreDefaults,
                 tcpipRestoreDefaults,
                 tcpipFirmwareUpgrade,
                 nwRestoreDefaults,
                 nwFirmwareUpgrade,
                 bvRestoreDefaults,
                 bvFirmwareUpgrade,
                 eTalkRestoreDefaults"
        ::= { commands 2 }
        
        cmdPrintConfig OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will cause the device to print a
                 configuration page."
            ::= { commands 3 }
        
        cmdRestoreDefaults OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will restore all parameters on the device
                 to factory defaults, as well as reset the device."
            ::= { commands 4 }
        
        -- the okipsSNMP group
        
        snmpGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the snmp group."
            ::= { okipsSNMP 1 }
        
        snmpRestoreDefaults OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will restore all SNMP parameters
                 on the device to factory defaults, as well as reset
                 the device."
            ::= { okipsSNMPCommands 1 }
        
        snmpGetCommunityName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (1..31))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                "Get community name for the managed node.
        
                 In order for changes to this variable to take effect,
                 the print server must be reset.  See cmdReset to do
                 this."
            ::= { okipsSNMP 3 }
        
        snmpSetCommunityName OBJECT-TYPE
             SYNTAX  DisplayString (SIZE (1..31))
             ACCESS  read-write
             STATUS  optional
             DESCRIPTION
                  "Set community name for the managed node.  This value
                  cannot be read, just set.
        
                  In order for changes to this variable to take effect,
                  the print server must be reset.  See cmdReset to do
                  this."
        ::= { okipsSNMP 4 }
        
        snmpTrapCommunityName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (1..31))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "Trap community name for the managed node."
            ::= { okipsSNMP 5 }
        
        snmpPrinterTrapMaskUsed OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                 "A bit mask showing which bits in the printer trap mask
                  are valid."
            ::= { okipsSNMPTrapMasks 1 }
        
        snmpPrinter2TrapMaskUsed OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                 "A bit mask showing which bits in the printer2 trap mask
                  are valid."
            ::= { okipsSNMPTrapMasks 2 }
        
        snmpTrapMaskTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF SNMPTrapEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A list of strings which show how each bit in the printer2
                  trap mask is used."
            ::= { okipsSNMPTrapMasks 3 }
        
        snmpTrapEntry OBJECT-TYPE
            SYNTAX  SNMPTrapEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A physical output port on the print server."
            INDEX   { SNMPTrapMaskIndex }
            ::= { snmpTrapMaskTable 1 }
        
        SNMPTrapEntry ::=
            SEQUENCE {
                snmpTrapMaskIndex
                    INTEGER,
                snmpTrapMaskString
                    OCTET STRING
            }
        
        snmpTrapMaskIndex OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A unique value for each bit in the SNMPTrapMask."
            ::= { snmpTrapEntry 1 }
        
        snmpTrapMaskString OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (30))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "String describing how the bit in the SNMPTrapMask is used."
              ::= { snmpTrapEntry 2 }
        
        -- the driver group
        
        driverGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the driver group."
            ::= { driver 1 }
        
        driverRXPackets OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of packets received."
            ::= { driver 2 }
        
        driverTXPackets OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of packets transmitted."
            ::= { driver 3 }
        
        driverRXPacketsUnavailable OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of inbound packets which were chosen
                 to be discarded even though no errors had been
                 detected to prevent their being deliverable to a
                 higher-layer protocol due to a lack of buffer space."
            ::= { driver 4 }
        
        driverRXPacketErrors OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of inbound packets that contained
                 errors preventing them from being deliverable to a
                 higher-layer protocol."
            ::= { driver 5 }
        
        driverTXPacketErrors OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of outbound packets that could not be
                 transmitted because of errors."
            ::= { driver 6 }
        
        driverTXPacketRetries OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of retransmitted packets."
            ::= { driver 7 }
        
        driverChecksumErrors OBJECT-TYPE
            SYNTAX  Counter
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of packets containing checksum errors
                 received."
            ::= { driver 8 }
        
        -- the tokenRing group
        
        trGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the tokenRing group."
            ::= { tokenRing 1 }
        
        trRestoreDefaults OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will restore all token-ring parameters
                 on the device to factory defaults, as well as reset
                 the device."
            ::= { trCommands 1 }
        
        trPriority OBJECT-TYPE
            SYNTAX  INTEGER (0..6)
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "The token which is passed around the ring until a
                 station needs it can be assigned a priority from 0 to
                 6.  Priority 0 is the lowest and 6 is the highest.  The
                 priority of the device can be increased to improve
                 performance.  However, the performance of file servers
                 and crucial stations could be affected.
        
                 In order for changes to this variable to take effect,
                 the device must be reset.  See cmdReset to do this."
                 ::= { trConfigure 1 }
        
        trEarlyTokenRelease OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "Early token release allows the device to release the
                 token immediately after transmitting data but only on
                 16 Mbps systems.  This feature enhances ring performance.
        
                 In order for changes to this variable to take effect,
                 the device must be reset.  See cmdReset to do this."
            ::= { trConfigure 2 }
        
        trPacketSize OBJECT-TYPE
            SYNTAX  INTEGER {
                one-k(1),
                two-k(2),
                four-k(3)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "You should only change the packet size if you are
                 using a driver for your Token Ring adapter which
                 allows packet sizes greater than One-K.
        
                 In order for changes to this variable to take effect,
                 the device must be reset.  See cmdReset to do this."
            ::= { trConfigure 3 }
        
        trRouting OBJECT-TYPE
            SYNTAX  INTEGER {
                off(1),
                all-None(2),
                single-All(3),
                single-None(4)
            }
           ACCESS  read-write
           STATUS  optional
           DESCRIPTION
                "Set this variable to change the source routing
                configuration on the device.
        
                Off:  No source routing.
        
                All, None:  All-routes broadcast, nonbroadcast return.
                The frame will be transmitted on every route within
                the network resulting in multiple copies on a given ring.
        
                Single, All:  Single-route broadcast, all routes
                broadcast return.  The frame will be transmitted across
                the designated bridges, which will result in the frame
                appearing only once on each ring.  The response frame
                is on all routes broadcast to the originator.
        
                Single, None:  Single-route broadcast, nonbroadcast
                return.  The frame will be transmitted across designated
                bridges, which will result in the frame appearing only
                once each ring.
        
                 In order for changes to this variable to take effect,
                 the device must be reset.  See cmdReset to do this."
            ::= { trConfigure 4 }
        
        trLocallyAdminAddr OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (6))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "This is the locally administered node address for the
                 device.  Valid values are 000000000000 and between
                 400000000000 and 7FFFFFFFFFFF.  A value of 000000000000
                 indicates that a locally administered address is not in
                 use."
            ::= { trConfigure 5 }
        
        -- the psGeneral group
        
        psGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the psGeneral group."
            ::= { psGeneral 1 }
        
        psJetAdminEnabled OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                 "Indicates whether or not the JetAdmin support is
                 enabled on the print server.
        
                 In order for changes to this variable to take effect,
                 the print server must be reset.  See cmdReset to do
                 this."
            ::= { psGeneral 2 }

        psVerifyConfiguration OBJECT-TYPE
            SYNTAX  INTEGER {
                getvalue(0),
                serial-configuration(1)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "This variable is used to force the print server to verify valid configuration
                  settings. Setting the variable to the appropriate enumeration will cause the 
                  print server to verify the settings for that enumeration. If the settings are
                  valid, the result of the set will be OK. If the settings are not valid, the 
                  result will be BadValue. Gets on this variable will always return 0. 
                 
                 1 - Indicates whether or not the current serial configuration is
                      valid. 
                     Valid configurations - If the serial port is set in bidirectional mode,
                     the baud rate must be less than 115200 and the handshaking must be set to 
                     hardware handshaking.
                
                 2 - Not used yet. 
                 "
            ::= { psGeneral 3 }

        -- the psOutput group
        
        outputGroupVersion OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The version for the output group."
            ::= { psOutput 1 }
        
        outputRestoreDefaults OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                 "A value of 2 will restore all output parameters on
                 the print server to factory defaults, as well as reset
                 the print server."
            ::= { outputCommands 1 }
        
        outputCommandsTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF OutputCommandsEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A list of physical output ports.  The number of
                 entries is given by the value of outputNumPorts."
            ::= { outputCommands 2 }
            
        outputCommandsEntry OBJECT-TYPE
            SYNTAX  OutputCommandsEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A physical output port on the print server."
            INDEX   { outputIndex }
            ::= { outputCommandsTable 1 }
            
        OutputCommandsEntry ::=
            SEQUENCE {
                outputCancelCurrentJob
                    INTEGER
            }
            
        outputCancelCurrentJob OBJECT-TYPE
            SYNTAX  INTEGER {
                no(1),
                yes(2)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "A value of 2 will cancel the job currently printing 
                 on that port."
            ::= { outputCommandsEntry 1 }

        outputNumPorts OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of physical output ports on the print
                 server."
            ::= { outputConfigure 1 }
        
        outputTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF OutputEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A list of physical output ports.  The number of
                 entries is given by the value of outputNumPorts."
            ::= { outputConfigure 2 }
        
        outputEntry OBJECT-TYPE
            SYNTAX  OutputEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A physical output port on the print server."
            INDEX   { outputIndex }
            ::= { outputTable 1 }
        
        OutputEntry ::=
            SEQUENCE {
                outputIndex
                    INTEGER,
                outputName
                    DisplayString,
                outputStatusString
                    DisplayString,
                outputStatus
                    INTEGER,
                outputExtendedStatus
                    INTEGER,
                outputPrinter
                    INTEGER,
                outputLanguageSwitching
                    INTEGER,
                outputConfigLanguage
                    INTEGER,
                outputPCLString
                    OCTET STRING,
                outputPSString
                    OCTET STRING,
                outputSetting
                    INTEGER,
                outputOwner
                    INTEGER,
                outputBIDIStatusEnabled
                    INTEGER,
                outputPrinterModel
                    DisplayString,
                outputPrinterDisplay
                    DisplayString,
                outputCapabilities
                    INTEGER,
                outputHandshake
                    INTEGER,
                outputProtocolManager
                             INTEGER
            }
        
        outputIndex OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A unique value for each physical output port.
                 Its value ranges between 1 and the value of
                 outputNumPorts.  The value for each protocol must
                 remain constant at least from one re-initialization
                 of the entity's network management system to the next
                 re-initialization."
            ::= { outputEntry 1 }
        
        outputName OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..15))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                 "A textual description of the output port."
            ::= { outputEntry 2 }
        
        outputStatusString OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..80))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the status of the physical
                 output port."
            ::= { outputEntry 3 }
        
        outputStatus OBJECT-TYPE
            SYNTAX  INTEGER  {
                on-Line(1),
                off-Line(2)
            }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Indicates status of the printer.  Get
                 outputExtendedStatus for further information."
            ::= { outputEntry 4 }
        
        outputExtendedStatus OBJECT-TYPE
            SYNTAX  INTEGER  {
                none(1),
                no-Printer-Attached(2),
                toner-Low(3),
                paper-Out(4),
                paper-Jam(5),
                door-Open(6),
                printer-Error(15)
            }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Indicates printer status to be used in conjunction with
                 outputStatus."
            ::= { outputEntry 5 }
        
        outputPrinter OBJECT-TYPE
            SYNTAX  INTEGER {
                okidata(2),
                no-Specific-Printer(4)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "The type of printer the output port is attached to.
        
                 Even if the group is supported, this variable may not
                 be supported."
        ::= { outputEntry 6 }
        
        outputLanguageSwitching OBJECT-TYPE
            SYNTAX  INTEGER {
                off(1),
                pcl(2),
                postScript(3),
                als(4)
            }
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "Indicates the language switching option for the physical
                 port.
        
                 Even if the group is supported, this variable may not be
                 supported."
            ::= { outputEntry 7 }
        
        outputConfigLanguage OBJECT-TYPE
            SYNTAX  INTEGER {
                text(1),
                pcl(2),
                postScript(3),
                off(4)
            }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                 "Indicates the language that configuration pages will be
                 printed in.
        
                 If set to off, a config sheet will not be printed on this
                 port."
            ::= { outputEntry 8 }
        
        outputPCLString OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (127))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                 "This string will be sent out the physical port if
                 (1) outputLanguageSwitching is set to PCL or
                 outputLanguageSwitching is set to Auto and the job is
                   determined to be PCL, and (2) outputPrinter is set to
                   No-Specific-Printer.
        
                   Even if the group is supported, this variable may not be
                   supported."
              ::= { outputEntry 9 }
        
        outputPSString OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (127))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This string will be sent out the physical port if
                   (1) outputLanguageSwitching is set to PostScript or
                   outputLanguageSwitching is set to Auto and the job is
                   determined to be PostScript, and (2) outputPrinter is
                   set to No-Specific-Printer.
        
                   Even if the group is supported, this variable may not be
                   supported."
              ::= { outputEntry 10 }

          outputSetting OBJECT-TYPE
              SYNTAX  INTEGER {
                  serial-infrared(32758),
                  serial-bidirectional(32759),
                  serial-unidirectional(32760),
                  serial-input(32761),
                  parallel-compatibility-no-bidi(32762),
                  ieee-1284-std-nibble-mode(32763),
                  z-Link(32764),
                  internal(32765),
                  ieee-1284-ecp-or-fast-nibble-mode(32766),
                  extendedLink(32767)          
              }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                   "Indicates the type (and optionally speed) for the
                   physical output port.  Setting this variable to physical
                   connections (such as Parallel) will result in an error.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { outputEntry 12 }
        
          outputOwner OBJECT-TYPE
              SYNTAX  INTEGER {
                  no-Owner(1),
                  tcpip(2),
                  netware(3),
                  vines(4),
                  lanManager(5),
                  etherTalk(6),
                  config-Page(7)
              }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "Indicates which protocol or task currently is printing on
                   the port."
              ::= { outputEntry 13 }
        
          outputBIDIStatusEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 indicates that the BIDI status system is
                    enabled."
              ::= { outputEntry 14 }
        
          outputPrinterModel OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..60))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A string indicating the printer model attached to the output port."
              ::= { outputEntry 15 }
        
          outputPrinterDisplay OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..30))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A string indicating the message on the attached printer front panel."
              ::= { outputEntry 16 }
        
          outputCapabilities OBJECT-TYPE
              SYNTAX  INTEGER {
                  serial-Uni-Baud-9600(1),
                  serial-Uni-Baud-19200(2),
                  serial-Uni-Baud-38400(4),
                  serial-Uni-Baud-57600(8),
                  serial-Uni-Baud-115200(16),
                  serial-bidi-Baud-9600(32),
                  serial-bidi-Baud-19200(64),
                  serial-bidi-Baud-38400(128),
                  serial-bidi-Baud-57600(256),
                  serial-irin(524288),
                  serial-in(1048576),
                  serial-config-settings(2097152),
                  parallel-compatibility-no-bidi(4194304),
                  ieee-1284-std-nibble-mode(8388608),
                  bidirectional(33554432),
                  serial-Software-Handshake(67108864),
                  serial-Output(134217728),
                  internal(536870912),
                  ieee-1284-ecp-or-fast-nibble-mode(1073741824)
              }
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "This field is implemented as a BIT mask.  If the bit is set then
                   the port is capable of functioning in this mode.
        
                   Bit  Property
                   ---  ------------------------
                   0    Serial Unidirectional Baud 9600
                   1    Serial Unidirectional Baud 19200
                   2    Serial Unidirectional Baud 38400
                   3    Serial Unidirectional Baud 57600
                   4    Serial Unidirectional Baud 115200
                   5    Serial Bidirectional Baud 9600
                   6    Serial Bidirectional Baud 19200
                   7    Serial Bidirectional Baud 38400
                   8    Serial Bidirectional Baud 57600
                   19   Infrared Input on serial port
                   20   Serial Input
                   21   Serial Configuration Settings
                   22   Parallel Compatibility Mode (no bidi)
                   23   IEEE 1284 Standard Nibble Mode
                   25   Bidirectional Support (PJL status)
                   26   Serial Software Handshaking
                   27   Serial Output
                   29   Printer Internal (MIO)
                   30   IEEE 1284 ECP or Fast Nibble Mode"
              ::= { outputEntry 17 }
        
          outputHandshake OBJECT-TYPE
              SYNTAX  INTEGER {
                  not-Supported(1),
                  hardware-Software(2),
                  hardware(3),
                  software(4)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "If the port in serial mode operation this indicates the
                   handshaking method being used.  Setting this value to 'not-
                   supported' will result in an error.  Setting this value on
                   non serial capable ports will result in an error.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { outputEntry 18 }
                      
          outputProtocolManager OBJECT-TYPE
              SYNTAX  INTEGER {
                   protocol-none(0),      
                   protocol-compatibility(1),
                   protocol-1284-4(2)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   " Indicates the type of output protocol manager being used on the
                     port.  Protocol-none means either there is no printer attached or
                     the print server has not yet determined which output managers are
                     supported on the printer.   Protocol-compatibility means the printer
                     does not support any of the protocol managers supported by the print
                     server.  Protocol-1284-4 means the output is using the 1284.4 logical
                     port protocol manager.
                   "
              ::= { outputEntry 23 }
        
                              
        outputDisplayMask OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Bit mask describing what should be displayed by the utilities
        
                  bit   Description
                  ---   -----------
                  0     outputCancelCurrentJob (Includes all CancelCurrentJob info)
                  1     outputName
                  2     outputStatusString
                  3     outputStatus
                  4     outputExtendedStatus
                  5     outputPrinter
                  6     outputLanguageSwitching
                  7     outputConfigLanguage
                  8     outputString (Includes outputPCLString and outputPSString)
                  9     outputCascaded
                  10    outputSetting
                  11    outputOwner
                  12    outputBIDIStatusEnabled
                  13    outputPrinterModel
                  14    outputPrinterDisplay
                  15    outputHandshake
                  16    outputJobLog  (includes all job logging)
                  17    outputSerialConfig
                  18    NoPrinterType1
                  19    NoPrinterType2
                  20    NoPrinterType3
                  21    NoPrinterType4"
            ::= { psOutput 4 }
        
        outputAvailableTrapsMask OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Bit mask describing what output printer traps are available
        
                  bit   Description
                  ---   -----------
                  0     online
                  1     offline
                  2     printer attached
                  3     toner low
                  4     paper out
                  5     paper jam
                  6     door open
                  7     printer error"
            ::= { psOutput 5 }
        
        outputNumLogEntries OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The number of job log entries per output port."
            ::= { outputJobLog 1 }
        
        outputJobLogTable OBJECT-TYPE
            SYNTAX  SEQUENCE OF OutputJobLogEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                 "A 2 dimensional list of Job log entries indexed by the output port
                 number and the log entry index (1 through outputNumJobLogEntries).
                 The number of entries per output port is given by the value of
                 outputNumJobLogEntries."
            ::= { outputJobLog 2 }
        
        outputJobLogEntry OBJECT-TYPE
            SYNTAX  OutputJobLogEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A Job log entry."
            INDEX   { outputIndex }
            ::= { outputJobLogTable 1 }
        
        OutputJobLogEntry ::=
            SEQUENCE {
                outputJobLogInformation
                    DisplayString,
                outputJobLogTime
                    DisplayString
            }
        
        outputJobLogInformation OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..100))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A textual description of print job information.
                 The protocol, source, and file size are always included.
                 Other information such as File Server, Queue, File Name, etc
                 will be included if available."
            ::= { outputJobLogEntry 1 }
        
        outputJobLogTime OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..50))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "A string indicating the elasped time since the last job was
                 printed. Reported in form X hours X minutes X seconds."
            ::= { outputJobLogEntry 2 }
        
        outputTotalJobTable OBJECT-TYPE
           SYNTAX  SEQUENCE OF OutputTotalJobEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
                "Table showing the total number of jobs printed for each port."
           ::= { outputJobLog 3 }
        
        outputTotalJobEntry OBJECT-TYPE
           SYNTAX  OutputTotalJobEntry
           ACCESS  not-accessible
           STATUS  mandatory
           DESCRIPTION
               "An entry in the outputTotalJobTable."
           INDEX   { outputTotalJobIndex }
           ::= { outputTotalJobTable 1 }
        
        OutputTotalJobEntry ::=
           SEQUENCE {
               outputTotalJobIndex
                   INTEGER,
               outputTotalJobsLogged
                   INTEGER
           }
        
        outputTotalJobIndex OBJECT-TYPE
           SYNTAX  INTEGER
           ACCESS  read-only
           STATUS  mandatory
           DESCRIPTION
                "A unique value for entry in the outputTotalJobTable.
                Its value ranges between 1 and the value of
                numPorts."
           ::= { outputTotalJobEntry 1 }
        
        outputTotalJobsLogged OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "The total number of jobs printed by the port since the
                 print server was powered on. "
            ::= { outputTotalJobEntry 2 }
        
        
          -- the tcpip group
        
          tcpipGroupVersion OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The version for the tcpip group."
              ::= { tcpip 1 }
        
          tcpipEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates whether or not the tcpip protocol stack is
                   enabled on the print server.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { tcpip 2 }
        
          tcpipRestoreDefaults OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will restore all tcpip parameters on
                   the print server to factory defaults, as well as reset
                   the print server."
              ::= { tcpipCommands 1 }
        
          tcpipFirmwareUpgrade OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will put the print server into firmware
                   upgrade mode waiting to receive a firmware upgrade file
                   via tftp."
              ::= { tcpipCommands 2 }
        
          tcpipIPAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The Internet Address.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { tcpipConfigure 1 }
        
          tcpipDefaultGateway OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The default gateway for the print server.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { tcpipConfigure 2 }
        
          tcpipSubnetMask OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The subnet mask for the print server.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
          ::= { tcpipConfigure 3 }
        
          tcpipUsingNetProtocols OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 indicates that the print server is using
                   a combination of RARP, BOOTP, default IP address, or
                   gleaning to determine its IP address.
        
                   See tcpipBootProtocolsEnabled to determine which boot
                   protocols are enabled.  If the value of
                   tcpipUsingNetProtocols is 1, the IP address is stored
                   permanently in flash memory.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { tcpipConfigure 4 }
        
          tcpipBootProtocolsEnabled OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which boot
                   protocols will be used to determine the print server's
                   IP address.
        
                        BIT       Boot Protocol Enabled
                        ---       --------------------------
                         0        RARP
                         1        BootP
                         2        DHCP
                         3        Gleaning
                         4        Default Address Enabled (If no address after 2 minutes
                                            timeout and go to 198.102.102.254) 
        
           A value of 31 indicates that all boot protocols are
                   enabled.  These protocols will only be used if
                   tcpipUsingNetProtocols is set to 2.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { tcpipConfigure 5 }
        
          tcpipIPAddressSource OBJECT-TYPE
              SYNTAX  INTEGER {
                  permanent(1),
                  default(2),
                  rarp(3),
                  bootp(4),
                  dhcp(5),
                  glean(6)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "This variable indicates how the IP address for the
                   print server was determined."
              ::= { tcpipConfigure 6 }
        
          tcpipIPAddressServerAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "This variable indicates the source of the IP address
                   if a boot protocol was used.  This value will be
                   0.0.0.0 if no boot server was used."
              ::= { tcpipConfigure 7 }
        
          tcpipTimeoutChecking OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 indicates that a packet timeout
                   will be active on all tcp connections.  If a packet has
                   not been received from the connection within this timeout the
                   connection will be reset.
        
                   To set this timeout, see tcpipTimeoutCheckingValue"
              ::= { tcpipConfigure 8 }
        
          tcpipNumTraps OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of UDP trap destinations."
              ::= { tcpipConfigure 9 }
        
          tcpipTrapTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF TcpipTrapEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "A list of UDP trap definitions.  The number of
                   entries is given by the value of tcpipNumTraps."
              ::= { tcpipConfigure 10 }
        
          tcpipTrapEntry OBJECT-TYPE
              SYNTAX  TcpipTrapEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                  "An entry in the tcpipTrapTable."
              INDEX   { tcpipTrapIndex }
              ::= { tcpipTrapTable 1 }
        
          TcpipTrapEntry ::=
              SEQUENCE {
                  tcpipTrapIndex
                      INTEGER,
                  tcpipTrapDestination
                      IpAddress,
                  tcpipPrinter2TrapMask
                      INTEGER,
                  tcpipPrinterTrapMask
                      INTEGER,
                  tcpipOutputTrapMask
                      INTEGER
              }
        
          tcpipTrapIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "A unique value for entry in the tcpipTrapTable.
                   Its value ranges between 1 and the value of
                   tcpipNumTraps."
              ::= { tcpipTrapEntry 1 }
        
          tcpipTrapDestination OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                  "This is the IP address that traps are sent to.
                  A value of 0.0.0.0 will disable traps over UDP."
              ::= { tcpipTrapEntry 2 }
        
          tcpipPrinter2TrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which protocol
                   specific traps will be sent out via UDP.
        
                   Currently no protocol specific traps are supported."
              ::= { tcpipTrapEntry 3 }
        
          tcpipPrinterTrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which printer
                   specific traps will be sent out via UDP.
        
                   A value of 65535 indicates that all printer specific
                   traps should be reported via UDP.
        
                        BIT       CONDITION
                        ---       --------------------------
                         0        On-line (Condition cleared)
                         1        Off-line
                         2        No printer attached
                         3        Toner Low
                         4        Paper Out
                         5        Paper Jam
                         6        Door Open
                        15        Printer Error"
              ::= { tcpipTrapEntry 4 }
        
          tcpipOutputTrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which physical
                   output ports will be checked when generating printer
                   specific traps to be sent out via UDP.
        
                   A value of 65535 indicates that all physical output ports
                   will generate traps.
        
                        BIT       CONDITION
                        ---       --------------------------
                         0        Port 1
                         1        Port 2
                         2        Port 3
                         3        Port 4
                         ...        ..."
              ::= { tcpipTrapEntry 5 }
        
          tcpipBanners OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 indicates that banners will be printed
                   with tcpip jobs.
        
                   Even if the group is supported, this variable may not be
                   supported."
              ::= { tcpipConfigure 11 }
        
          tcpipWinsAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The IP address of the WINS server.
        
                    The print server will register its sysName to
                    this WINS server."
              ::= { tcpipConfigure 12 }
        
          tcpipWinsAddressSource OBJECT-TYPE
              SYNTAX  INTEGER {
                  dhcp(1),
                  permanent(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The source of the WINS server address.
        
                    If set to dhcp, the print server will use the
                    WINS address supplied with dhcp.
        
                    If it is set to permanent, it will use the
                    WINS address stored in flash."
              ::= { tcpipConfigure 13 }
        
          tcpipConfigPassword OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (5..24))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The print server html/telnet configuration password.
                   This value cannot be read, just set."
              ::= { tcpipConfigure 14 }
        
          tcpipTimeoutCheckingValue OBJECT-TYPE
              SYNTAX  INTEGER (0..65535)
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The TCP connection timeout in seconds.
                    A value of 0 has the same effect as disabling
                    timeout checking."
              ::= { tcpipConfigure 15 }
        
          tcpipArpInterval OBJECT-TYPE
              SYNTAX  INTEGER (0..30)
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The ARP interval in minutes.
                    The print server will ARP itself once when
                    this timer expires.  Set to 0 to disable."
              ::= { tcpipConfigure 16 }
        
          tcpipRawPortNumber OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The raw TCP port number the print server will listen
                    for print jobs on.  On multiple port devices, additional
                    ports will sequentially follow this port number.
                    The default port is 9100.  Setting this value to a TCP
                    port that is in use by another TCP application will 
                    return an error.
                    
                    In order for changes to this variable to take effect,
                    the print server must be reset.  See cmdReset to do
                    this."
              ::= { tcpipConfigure 17 }
              
          tcpipNumSecurity OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of secure IP address ranges."
              ::= { tcpipConfigure 18 }  
          
          tcpipSecurityTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF TcpipSecurityEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "A list of secure IP address ranges.  This adds security for both
                   printing and admin rights. 
                   
                   AdminEnabled: When the admin enabled field is set to yes for a secure
                   address range, the print server may only be configured via IP from 
                   IP address within that range. If the admin field is not set for any address
                   ranges, the print server will accept admin commands from any IP address 
                   which has the valid community names and/or passwords. 
                   
                   PortMask: When there is a port mask set for a secure IP address range, the 
                   print server will only accept TCP/IP print jobs from hosts that are in the
                   secure address range.  If there are no ranges with a port mask set, the print
                   server will accept TCP/IP print jobs from any host.
                   
                   The number of entries is given by the value of tcpipNumSecurity."
              ::= { tcpipConfigure 19 }
        
          tcpipSecurityEntry OBJECT-TYPE
              SYNTAX  TcpipSecurityEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                  "An entry in the tcpipSecurityTable."
              INDEX   { tcpipSecurityIndex }
              ::= { tcpipSecurityTable 1 }
        
          TcpipSecurityEntry ::=
              SEQUENCE {
                  tcpipSecurityIndex
                      INTEGER,
                  tcpipSecureStartIPAddress
                      IpAddress,
                  tcpipSecureEndIPAddress
                      IpAddress,
                  tcpipSecurePrinterMask
                      INTEGER,
                  tcpipSecureAdminEnabled
                      INTEGER
              }
        
          tcpipSecurityIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "A unique value for entry in the tcpipSecurityTable.
                   Its value ranges between 1 and the value of
                   tcpipNumSecurity."
              ::= { tcpipSecurityEntry 1 }
        
          tcpipSecureStartIPAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                  "This is the starting IP address for the secure IP
                  address range.  A value of 0.0.0.0 for both
                  tcpipStartIPAddress and tcpipEndIPAddress will 
                  disable the address range."
              ::= { tcpipSecurityEntry 2 }
        
          tcpipSecureEndIPAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                  "This is the ending IP address for the secure IP
                  address range.  A value of 0.0.0.0 for both
                  tcpipStartIPAddress and tcpipEndIPAddress will 
                  disable the address range."
              ::= { tcpipSecurityEntry 3 }
        
          tcpipSecurePrinterMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 8 bit mask which determines which physical
                   output ports this range of IP addresses can print to.
                   A value of 127 indicates that the range of IP addresses
                   can print to any of the output ports.
                   
                   This value can not be configured until a valid start and 
                   end address range have been configured.
        
                        BIT       CONDITION
                        ---       --------------------------
                         0        Port 1
                         1        Port 2
                         2        Port 3
                         3        Port 4
                        ...        ...
                         8        Reserved, must be set to 0."
              ::= { tcpipSecurityEntry 4 }
              
          tcpipSecureAdminEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   " This allows an advanced level of admin security for IP. Setting this will 
                   restrict which IP addresses can configure the print server. The 
                   correct community names and passwords are still required if this is used, it
                   just adds another level of security. 
                    
                   Indicates whether or not admin rights are enabled for this range of 
                   IP addresses. If no range of addresses has this enabled, then any IP address
                   can configure the print server if it has the correct community names and/or
                   passwords. If this field is set to yes for any range of addresses, the 
                   print server will only be configurable via IP from that range of addresses.
                   
                   This value can not be configured until a valid start and end address range 
                   have been configured."
                   
              ::= { tcpipSecurityEntry 5 }
          
          tcpipLowBandwidth OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will optimize the TCP stack for low bandwidth
                    networks.  A value of 1 will optimize the TCP stack for high
                    bandwidth networks."
              ::= { tcpipConfigure 20 }
              
          tcpipNumLogicalPrinters OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of available logical printers."
              ::= { tcpipConfigure 21 }  
          
          tcpipMLPTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF TcpipMLPEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "A table of the available logical printers.
                   The number of entries is given by the value of tcpipNumLogicalPrinters."
              ::= { tcpipConfigure 22 }
        
          tcpipMLPEntry OBJECT-TYPE
              SYNTAX  TcpipMLPEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                  "An entry in the tcpipMLPTable."
              INDEX   { tcpipMLPIndex }
              ::= { tcpipMLPTable 1 }
        
          TcpipMLPEntry ::=
              SEQUENCE {
                  tcpipMLPIndex
                      INTEGER,
                  tcpipMLPName
                      DisplayString,
                  tcpipMLPPort
                      INTEGER,
                  tcpipMLPTCPPort
                      INTEGER,
                  tcpipMLPPreString
                      DisplayString,
                  tcpipMLPPostString
                      DisplayString,
                  tcpipMLPDeleteBytes
                      INTEGER
              }
        
          tcpipMLPIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for entry in the tcpipMLPTable.
                    Its value ranges between 1 and the value of
                    tcpipNumLogicalPrinters."
              ::= { tcpipMLPEntry 1 }
        
        
          tcpipMLPName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..20))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Contains the name of the logical printer.  This name is also
                    the LPR remote queue name associated with the logical printer."
              ::= { tcpipMLPEntry 2 }
              
          tcpipMLPPort OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The number of the physical output port associated with the logical
                    printer.
                    
                    In order for changes to this variable to take effect,
                    the print server must be reset.  See cmdReset to do
                    this."
              ::= { tcpipMLPEntry 3 }
              
          tcpipMLPTCPPort OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The TCP port associated with the logical printer.  Any print data
                    sent to this TCP port will be processed through this logical
                    printer entry.
                    
                    In order for changes to this variable to take effect,
                    the print server must be reset.  See cmdReset to do
                    this."
              ::= { tcpipMLPEntry 4 }
              
          tcpipMLPPreString OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..64))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This contains any data that should be sent down to the printer
                    at the beginning of jobs sent to this logical printer.  To enter
                    non-printable ascii characters in the string, enclose the decimal 
                    value inside of <>.  For example, to enter an ESC-E the string would 
                    be '<27>E'."
              ::= { tcpipMLPEntry 5 }
              
          tcpipMLPPostString OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..64))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This contains any data that should be sent down to the printer
                    at the end of jobs sent to this logical printer.  To enter
                    non-printable ascii characters in the string, enclose the decimal 
                    value inside of <>.  For example, to enter an ESC-E the string would 
                    be '<27>E'."
              ::= { tcpipMLPEntry 6 }
        
          tcpipMLPDeleteBytes OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The number of bytes that will be deleted from the beginning of
                    jobs sent to this logical printer."
              ::= { tcpipMLPEntry 7 }
        
          tcpipSmtpServerAddr OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The IP address of the e-mail server which will be used to send e-mail
                   notification of printer status conditions. This address must contain the 
                   valid IP address of an e-mail server before any of the contents of the 
                   SmtpTable are used."
              ::= { tcpipConfigure 23 }
        
          tcpipNumSmtpDestinations OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of configurable e-mail destinations to receive
                    printer status conditions. "
              ::= { tcpipConfigure 24 }
        
          tcpipSmtpTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF TcpipSmtpEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "A list of SMTP e-mail addresses and printer status conditions
                   to send e-mails for. The number of entries is given by the 
                   value of tcpipNumSmtpDestinations."
              ::= { tcpipConfigure 25 }
        
          tcpipSmtpEntry OBJECT-TYPE
              SYNTAX  TcpipSmtpEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                  "An entry in the tcpipSmtpTable."
              INDEX   { tcpipSmtpIndex }
              ::= { tcpipSmtpTable 1 }
        
          TcpipSmtpEntry ::=
              SEQUENCE {
                  tcpipSmtpIndex
                      INTEGER,
                  tcpipSmtpEmailAddr
                      OCTET STRING,
                  tcpipSmtpProtocolMask
                      INTEGER,
                  tcpipSmtpPrinterMask
                      INTEGER,
                  tcpipSmtpOutputMask
                      INTEGER
              }
        
          tcpipSmtpIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "A unique value for entry in the tcpipSmtpTable.
                   Its value ranges between 1 and the value of
                   tcpipNumSmtpDestinations."
              ::= { tcpipSmtpEntry 1 }
        
          tcpipSmtpEmailAddr OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the e-mail address that printer status conditions 
                  are sent to. If this string is empty the status conditions will
                  not be sent."
              ::= { tcpipSmtpEntry 2 }
        
          tcpipSmtpProtocolMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which protocol
                   specific conditions will be sent out via e-mail.
        
                   Currently no protocol specific conditions are supported."
              ::= { tcpipSmtpEntry 3 }
        
          tcpipSmtpPrinterMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which printer
                   specific conditions will be sent out via e-mail.
        
                   A value of 65535 indicates that all printer specific
                   conditions should be reported via e-mail.
        
                      BIT       CONDITION
                      ---       --------------------------
                       0        On-line (Condition cleared)
                       1        Off-line
                       2        No printer attached
                       3        Toner Low
                       4        Paper Out
                       5        Paper Jam
                       6        Door Open
                      15        Printer Error"
              ::= { tcpipSmtpEntry 4 }
        
          tcpipSmtpOutputMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which physical
                   output ports will be checked when generating printer
                   specific conditions to be sent out via e-mail.
        
                   A value of 65535 indicates that all physical output ports
                   will generate e-mails upon a change in status.
        
                              BIT       CONDITION
                              ---       --------------------------
                               0        Port 1
                               1        Port 2
                               2        Port 3
                               3        Port 4
                              ...        ..."
              ::= { tcpipSmtpEntry 5 }
        
          tcpipWebAdminName OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (25))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the admin name used by web configuration for login."
              ::= { tcpipConfigure 26 }
        
          tcpipWebAdminPassword OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (25))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the admin password used by web configuration for login."
              ::= { tcpipConfigure 27 }
        
          tcpipWebUserName OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (25))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the user name used by web configuration for login. Not
                   currently used. "
              ::= { tcpipConfigure 28 }
        
          tcpipWebUserPassword OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (25))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the user password used by web configuration for login. Not
                  currently used."
              ::= { tcpipConfigure 29 }
        
          tcpipWebHtttpPort OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The port number used to communicate over http. Must be between 0 and 
                   65535. It must not be the same as any other port used. Other ports used are
                   20, 21, 23, 515, & raw port numbers (9100, 9101, ...  if at default)" 
              ::= { tcpipConfigure 30 }
        
          tcpipWebFaqURL OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the URL for FAQ at the ESI (or other OEM) website."
              ::= { tcpipConfigure 31 }
        
          tcpipWebUpdateURL OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the URL for finding firmware updates at the ESI 
                  (or other OEM) website."
              ::= { tcpipConfigure 32 }
        
          tcpipWebCustomLinkName OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (25))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the name assigned to the custom link defined by the user."
              ::= { tcpipConfigure 33 }
        
          tcpipWebCustomLinkURL OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the URL for a custom link specified by the user."
              ::= { tcpipConfigure 34 }
        
          tcpipPOP3ServerAddress OBJECT-TYPE
              SYNTAX  IpAddress
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The IP address of the POP3 server from which email will be retrieved. 
                   This address must contain the valid IP address of a POP3 server before 
                   any attempts to retrieve email will be made."
              ::= { tcpipConfigure 35 }
        
          tcpipPOP3PollInterval OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                   "The number of seconds between attempts to retrieve mail from the 
                   POP3 server. "
              ::= { tcpipConfigure 36 }
        
          tcpipPOP3UserName OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the user name for the print server's email account on 
                  the POP3 server."
              ::= { tcpipConfigure 37 }
        
          tcpipPOP3Password OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (20))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the password for the print server's email account on
                  the POP3 server."
              ::= { tcpipConfigure 38 }
        
          tcpipDomainName OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE (64))
            ACCESS  read-write
            STATUS  optional
            DESCRIPTION
                  "This is the Domain name used by POP3 and SMTP."
              ::= { tcpipConfigure 39 }
          
          tcpipCapabilities OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                 "Bit mask describing TCPIP capabilities.  If the BIT is set then the
                 feature is supported.
                 
                  bit   Description
                  ---   -----------
                  0     LPR/LPD 
                  1     Raw port printing
                  2     FTP 
                  3     POP3 printing 
                  4     Multiple logical printers
                  5     IPP
                  6     HTTP
                  7     HTTP Variables
                  8     Telnet
                  9     IP Security
                  10    Timeout checking
                  11    Fragmentation
                  12    Default IP address assignment
                  13    DHCP IP address assignment
                  14    BOOTP IP address assignment
                  15    RARP IP address assignment
                  16    Gleaning IP address assignment
                  17    IP Enterprise Traps
                  18    SMTP Traps
                  19    WINS
                  20    DDNS
                  21    Encryption1"
              ::= { tcpipConfigure 40 }
        
                    
        tcpipError OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..80))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Contains any tcpip specific error information."
              ::= { tcpipStatus 1 }

          tcpipDisplayMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "Bit mask describing what should be displayed by the utilities
                 
                  bit   Description
                  ---   -----------
                  0     tcpipAddress (Includes tcpipDefaultGateway and tcpipSubnetMask)
                  1     tcpipUsingNetProtocols (Includes tcpipBootProtocolsEnabled, tcpipAddressSource,                                                                tcpipAddressServerAddress)
                  2     tcpipTimeoutChecking
                  3     tcpipTraps (Includes all trap info)
                  4     tcpipBanners
                  5     tcpipSecurity (Includes all security info)
                  6     tcpipWinsAddress (Includes tcpipWinsAddressSource)
                  7     tcpipConfigPassword
                  8     tcpipTimeoutCheckingValue
                  9     tcpipArpInterval
                  10    tcpipRawPortNumber
                  11    tcpipError
                  12    tcpipLowBandwidth
                  13    tcpipMLP (Includes all logical printer settings)
                  14    tcpipPOP3"
              ::= { tcpip 6 }
       
          -- the netware group
        
          nwGroupVersion OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The version for the netware group."
              ::= { netware 1 }
       
          nwEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                    "Indicates whether or not the NetWare protocol stack is
                    enabled on the print server.
           
                    In order for changes to this variable to take effect,
                    the print server must be reset.  See cmdReset to do
                    this."
               ::= { netware 2 }
        
          nwRestoreDefaults OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will restore all NetWare parameters on
                   the print server to factory defaults, as well as reset
                   the print server."
          ::= { nwCommands 1 }
        
          nwFirmwareUpgrade OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will put the print server into firmware
                   upgrade mode."
              ::= { nwCommands 2 }
        
          nwFrameFormat OBJECT-TYPE
              SYNTAX  INTEGER {
                  unknown(1),
                  ethernet-II(2),
                  ethernet-802-3(3),
                  ethernet-802-2(4),
                  ethernet-Snap(5),
                  token-Ring(6),
                  token-Ring-Snap(7)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Indicates the frame format that the print server is
                   using.  See nwSetFrameFormat to determine which frame
                   frame format the print server is configured for."
              ::= { nwConfigure 1 }
        
          nwSetFrameFormat OBJECT-TYPE
              SYNTAX  INTEGER {
                  auto-Sense(1),
                  forced-Ethernet-II(2),
                  forced-Ethernet-802-3(3),
                  forced-Ethernet-802-2(4),
                  forced-Ethernet-Snap(5),
                  forced-Token-Ring(6),
                  forced-Token-Ring-Snap(7)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the frame format that the print server is
                   using.  Setting this value to 1 (Auto-Sense) indicates
                   that automatic frame format sensing will be used.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwConfigure 2 }
        
          nwMode OBJECT-TYPE
              SYNTAX  INTEGER {
                  unknown(1),
                  pserver(2),
                  rprinter(3)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Mode the print server is running in.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwConfigure 3 }
        
          nwPrintServerName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Contains print server name.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwConfigure 4 }
        
          nwPrintServerPassword OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..9))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The print server password.  This value cannot be read,
                   just set.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwConfigure 5 }
        
          nwQueueScanTime OBJECT-TYPE
              SYNTAX  INTEGER (1..255)
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Determines how often, in tenths of a second that the
                   print server will scan the queues for jobs.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwConfigure 6 }
        
          nwNetworkNumber OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (4))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The print server's network number."
              ::= { nwConfigure 7 }
        
          nwMaxFileServers OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The print server maximum number of file servers which
                   it can be attached to at once."
              ::= { nwConfigure 8 }
        
          nwFileServerTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF NwFileServerEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "A table of file servers to service."
              ::= { nwConfigure 9 }
        
          nwFileServerEntry OBJECT-TYPE
              SYNTAX  NwFileServerEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "A file server for the print server to service."
              INDEX   { nwFileServerIndex }
              ::= { nwFileServerTable 1 }
        
          NwFileServerEntry ::=
              SEQUENCE {
                  nwFileServerIndex
                      INTEGER,
                  nwFileServerName
                      DisplayString,
                  nwFileServerConnectionStatus
                      INTEGER
              }
        
          nwFileServerIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for each file server.  Its value
                   ranges between 1 and the value of nwMaxFileServers.
                   The value for each server must remain constant at
                   least from one re-initialization of the entity's
                   network management system to the next
                   re-initialization.  The first entry in the table is
                   the default file server."
              ::= { nwFileServerEntry 1 }
        
          nwFileServerName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The file server name.  This name will be NULL if there
                   is no file server to be serviced.  Only the default
                   file server (the first entry in the table) can be set.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwFileServerEntry 2 }
        
          nwFileServerConnectionStatus OBJECT-TYPE
              SYNTAX  INTEGER {
                  up(1),
                  down(2),
                  startupInProgress(3),
                  serverReattaching(4),
                  serverNeverAttached(5),
                  pse-UNKNOWN-FILE-SERVER(258),
                  pse-NO-RESPONSE(261),
                  pse-CANT-LOGIN(276),
                  pse-NO-SUCH-QUEUE(512),
                  pse-UNABLE-TO-ATTACH-TO-QUEUE(515),
                  bad-CONNECTION(768),
                  bad-SERVICE-CONNECTION(769),
                  other(32767)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The value describes the status of the connection
                   between the file server and the print server."
              ::= { nwFileServerEntry 3 }
        
          nwPortTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF NwPortEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "A table of NetWare port specific information."
              ::= { nwConfigure 10 }
        
          nwPortEntry OBJECT-TYPE
              SYNTAX  NwPortEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "An entry of NetWare port specific information."
              INDEX   { nwPortIndex }
              ::= { nwPortTable 1 }
        
          NwPortEntry ::=
              SEQUENCE {
                  nwPortIndex
                      INTEGER,
                  nwPortStatus
                      DisplayString,
                  nwPortPrinterNumber
                      INTEGER,
                  nwPortFontDownload
                      INTEGER,
                  nwPortPCLQueue
                      DisplayString,
                  nwPortPSQueue
                      DisplayString,
                  nwPortFormsOn
                      INTEGER,
                  nwPortFormNumber
                      INTEGER,
                  nwPortNotification
                      INTEGER
              }
        
          nwPortIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for each physical output port.  Its
                   value ranges between 1 and the value of outputNumPorts.
                   The value for each port must remain constant at least
                   from one re-initialization of the entity's network
                   management system to the next re-initialization."
              ::= { nwPortEntry 1 }
        
          nwPortStatus OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..80))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A string indicating the NetWare specific status of the
                   physical output port."
              ::= { nwPortEntry 2 }
        
          nwPortPrinterNumber OBJECT-TYPE
              SYNTAX  INTEGER (0..255)
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the printer number for the print server to
                   use when running in RPRinter mode.  A value of 255
                   indicates that the port is unconfigured for RPRinter
                   mode.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwPortEntry 3 }
        
          nwPortFontDownload OBJECT-TYPE
              SYNTAX  INTEGER {
                  disabled(1),
                  enabled-No-Power-Sense(2),
                  enabled-Power-Sense(3)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This variable controls the font downloading feature
                   of the print server.
        
                   Disabled - Do not download fonts.
        
                   Enabled, without Printer Sense - Only download fonts
                   after the print server has been reset or power cycled.
        
                   Enabled, with Printer Sense - Download fonts after the
                   print server has been reset or power-cycled, or after
                   the printer has been power-cycled.  This option is only
                   available on certain print servers.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwPortEntry 4 }
        
          nwPortPCLQueue OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A string indicating the name of the queue containing
                   the PCL fonts to download when font downloading is
                   enabled.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwPortEntry 5 }
        
          nwPortPSQueue OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A string indicating the name of the queue containing
                   the PS fonts to download when font downloading is
                   enabled.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwPortEntry 6 }
        
          nwPortFormsOn OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will enable forms checking.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { nwPortEntry 7 }
        
          nwPortFormNumber OBJECT-TYPE
              SYNTAX  INTEGER (0..255)
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the form number to check jobs against
                   when nwPortFormsOn is enabled."
              ::= { nwPortEntry 8 }
        
          nwPortNotification OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will enable job notification."
              ::= { nwPortEntry 9 }
        
          nwNumTraps OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of IPX trap destinations."
              ::= { nwConfigure 11 }
        
          nwTrapTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF NwTrapEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "A list of IPX trap definitions.  The number of
                   entries is given by the value of nwNumTraps."
              ::= { nwConfigure 12 }
        
          nwTrapEntry OBJECT-TYPE
              SYNTAX  NwTrapEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                  "An entry in the nwTrapTable."
              INDEX   { nwTrapIndex }
              ::= { nwTrapTable 1 }
        
          NwTrapEntry ::=
              SEQUENCE {
                  nwTrapIndex
                      INTEGER,
                  nwTrapDestination
                      OCTET STRING,
                  nwTrapDestinationNet
                      OCTET STRING,
                  nwPrinter2TrapMask
                      INTEGER,
                  nwPrinterTrapMask
                      INTEGER,
                  nwOutputTrapMask
                      INTEGER
              }
        
          nwTrapIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "A unique value for entry in the nwTrapTable.
                   Its value ranges between 1 and the value of
                   nwNumTraps."
              ::= { nwTrapEntry 1 }
        
          nwTrapDestination OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (6))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                  "This is the network address that IPX traps are sent to.
                  A value of 00 00 00 00 00 00 in conjunction with a
                  nwTrapDestinationNet of 00 00 00 00 will disable traps
                  over IPX."
              ::= { nwTrapEntry 2 }
        
          nwTrapDestinationNet OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (4))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                   "This is the network number that IPX traps are sent to.
                   A value of 00 00 00 00 in conjunction with a
                   nwTrapDestination of 00 00 00 00 00 00 will disable
                   traps over IPX."
              ::= { nwTrapEntry 3 }
        
          nwPrinter2TrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which protocol
                   specific traps will be sent out via IPX.
        
                   Currently no protocol specific traps are supported."
              ::= { nwTrapEntry 4 }
        
          nwPrinterTrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which printer
                   specific traps will be sent out via IPX.
        
                   A value of 65535 indicates that all printer specific
                   traps should be reported via IPX.
        
                              BIT       CONDITION
                              ---       --------------------------
                               0        On-line (Condition cleared)
                               1        Off-line
                               2        No printer attached
                               3        Toner Low
                               4        Paper Out
                               5        Paper Jam
                               6        Door Open
                              15        Printer Error"
              ::= { nwTrapEntry 5 }
        
          nwOutputTrapMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the 16 bit mask which determines which physical
                   output ports will be checked when generating printer
                   specific traps to be sent out via IPX.
        
                   A value of 65535 indicates that all physical output ports
                   will generate traps.
        
                              BIT       CONDITION
                              ---       --------------------------
                               0        Port 1
                               1        Port 2
                               2        Port 3
                               3        Port 4
                              ...        ..."
              ::= { nwTrapEntry 6 }
        
        
          nwNDSPrintServerName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..512))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Directory Services object used by the print server to
                 connect to the NDS tree.  This string contains the entire
                 canonicalized name.
        
                 NOTE: This variable must be stored in Unicode."
              ::= { nwConfigure 13 }
        
          nwNDSPreferredDSTree OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Directory Services tree to which the NDS print server
                 initially connects."
              ::= { nwConfigure 14 }
        
          nwNDSPreferredDSFileServer OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..47))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "The NetWare server to which the NDS print server initially
                 makes a bindery connection."
              ::= { nwConfigure 15 }
        
          nwNDSPacketCheckSumEnabled OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Compute the checksum for packets.
        
                        1 = disabled
                        2 = enabled"
              ::= { nwConfigure 16 }
        
          nwNDSPacketSignatureLevel OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Packet signature is a security method to prevent
                 packet forging.
        
                        1 = disabled
                        2 = enabled
                        3 = preferred
                        4 = required"
              ::= { nwConfigure 17 }
        
          nwAvailablePrintModes OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                "Reports which NetWare print modes are available.
        
                      BIT       CONDITION
                      ---       --------------------------
                       0        PServer
                       1        RPrinter
                       2        NDS
                       3        SPX Direct
                       4        JetAdmin
                "
              ::= { nwConfigure 18 }
        
          nwDirectPrintEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Indicates whether or not direct mode ipx/spx
                 printing is enabled."
              ::= { nwConfigure 19 }
        
          nwJAConfig OBJECT-TYPE
              SYNTAX INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                "Indicates whether or not JetAdmin was used to configure
                 the netware settings."
              ::= { nwConfigure 20 }
        
          nwDisableSAP OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                "Indicates whether or not SAPs are enabled."
              ::= { nwConfigure 21 }
        
                  nwError OBJECT-TYPE
                      SYNTAX  DisplayString (SIZE (0..160))
                      ACCESS  read-only
                      STATUS  optional
                      DESCRIPTION
                           "Contains any NetWare specific error information."
                      ::= { nwStatus 1 }
        
          nwDisplayMask OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "Bit mask describing what should be displayed by the utilities
                 
                  bit   Description
                  ---   -----------
                  0     nwFrameFormat
                  1     nwJetAdmin
                  2     nwFileServer (Includes all file server info)
                  3     nwMode
                  4     nwPrintServerName
                  5     nwPrintServerPassword
                  6     nwQueueScanTime
                  7     nwNetworkNumber
                  8     nwPortStatus
                  9     nwPortPrinterNumber
                  10    nwPortFontDownload (Includes nwPortPCLQueue and nwPortPSQueue)
                  11    nwPortFormsOn (Includes nwPortFormsNumber)
                  12    nwPortNotification
                  13    nwTraps (Includes all trap info)
                  14    nwNDSPrintServerName
                  15    nwNDSPreferredDSTree
                  16    nwNDSPreferredDSFileServer
                  17    nwNDSPacketCheckSumEnabled
                  18    nwNDSPacketSignatureLevel
                  19    nwDirectPrintEnabled
                  20    nwError
                  21    nwSapDisable"
              ::= { netware 6 }
                
          -- the vines group
        
          bvGroupVersion OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The version for the vines group."
              ::= { vines 1 }
        
          bvEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates whether or not the Banyan VINES protocol
                   stack is enabled on the print server."
              ::= { vines 2 }
        
          bvRestoreDefaults OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will restore all VINES parameters on
                   the print server to factory defaults, as well as reset
                   the device."
              ::= { bvCommands 1 }
        
          bvFirmwareUpgrade OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will put the print server into firmware
                   upgrade mode."
             ::= { bvCommands 2 }
        
          bvSetSequenceRouting OBJECT-TYPE
              SYNTAX  INTEGER {
                  automatic-Routing(1),
                  force-Sequenced-Routing(2),
                  force-Non-Sequenced-Routing(3)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Sets the VINES Routing selection.
        
                   Automatic - Utilizes Sequenced Routing if available,
                               otherwise uses Non-Sequenced Routing.
        
                   Force-Sequenced - Will only use Sequenced Routing.
        
                   Force-Non-Sequenced - Will only use Non-Sequenced Routing
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this.
        
                   WARNING - Sequential Routing requires a VINES 5.5 or
                   greater server on the same subnet."
              ::= { bvCommands 3 }
        
          bvDisableVPMan OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will disable VPMan access to the print
                   server for one minute."
              ::= { bvCommands 4 }
        
          bvLoginName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (5..63))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The StreetTalk name the device will use to login with.
                   This value will be OKIxxxxxxxx where xxxxxxx is the Serial
                   number of the device if it is unconfigured.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { bvConfigure 1 }
        
          bvLoginPassword OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..15))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The password for the login name, bvLoginName.  This value
                   cannot be read, just set.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { bvConfigure 2 }
        
          bvNumberPrintServices OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The number of Print Services this device supports."
              ::= { bvConfigure 3 }
        
          bvPrintServiceTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF BvPrintServiceEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "Table of Print Services for this device."
              ::= { bvConfigure 4 }
        
          bvPrintServiceEntry OBJECT-TYPE
              SYNTAX  BvPrintServiceEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "Print Services Table entry."
              INDEX   { bvPrintServiceIndex }
              ::= { bvPrintServiceTable 1 }
        
          BvPrintServiceEntry ::=
              SEQUENCE {
                  bvPrintServiceIndex
                      INTEGER,
                  bvPrintServiceName
                      DisplayString,
                  bvPrintServiceRouting
                      INTEGER
              }
        
          bvPrintServiceIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for each print service."
              ::= { bvPrintServiceEntry 1 }
        
          bvPrintServiceName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..63))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The StreetTalk Name for this Print Service.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { bvPrintServiceEntry 2 }
        
          bvPrintServiceRouting OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "The output port that the print service will print to.
                   This value will range from 0 to the number of output ports,
                   see outputNumPorts.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { bvPrintServiceEntry 3 }
        
          bvPnicDescription OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Contains the VINES PNIC description."
              ::= { bvConfigure 5 }

          bvError OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..48))
            ACCESS  read-only
            STATUS  optional
            DESCRIPTION
                 "Contains any VINES specific error information."
            ::= { bvStatus 1 }
      
          bvRouting OBJECT-TYPE
            SYNTAX  INTEGER {
                sequenced-Routing(1),
                non-Sequenced-Routing(2),
                unknown-Routing(32766),
                protocol-Disabled(32767)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The current VINES Routing being used by the device."
              ::= { bvStatus 2 }
        
          bvNumPrintServices OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The number of Print Services this device supports."
              ::= { bvStatus 3 }
        
          bvPrintServiceStatusTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF BvPrintServiceStatusEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "Table of Print Service Status Entry's."
              ::= { bvStatus 4 }
        
          bvPrintServiceStatusEntry OBJECT-TYPE
              SYNTAX  BvPrintServiceStatusEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "Print Service Status Entry."
              INDEX   { bvPSStatusIndex }
              ::= { bvPrintServiceStatusTable 1 }
        
          BvPrintServiceStatusEntry ::=
              SEQUENCE {
                  bvPSStatusIndex
                      INTEGER,
                  bvPSName
                      DisplayString,
                  bvPSStatus
                      DisplayString,
                  bvPSDestination
                      INTEGER,
                  bvPrinterStatus
                      DisplayString,
                  bvJobActive
                      INTEGER,
                  bvJobSource
                      DisplayString,
                  bvJobTitle
                      DisplayString,
                  bvJobSize
                      DisplayString,
                  bvJobNumber
                      DisplayString
              }
        
          bvPSStatusIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for each status entry."
              ::= { bvPrintServiceStatusEntry 1 }
        
          bvPSName OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..63))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The StreetTalk Name for this Print Service."
              ::= { bvPrintServiceStatusEntry 2 }
        
          bvPSStatus  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..48))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Print Service Status."
              ::= { bvPrintServiceStatusEntry 3 }
        
          bvPSDestination OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Port Destination for this print service."
              ::= { bvPrintServiceStatusEntry 4 }
        
          bvPrinterStatus OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..80))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                  "Printer status for this Print Service."
              ::= { bvPrintServiceStatusEntry 5 }
        
          bvJobActive OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Whether there is a VINES job active for this print
                   service."
              ::= { bvPrintServiceStatusEntry 6 }
        
          bvJobSource  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..64))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The active print jobs source."
              ::= { bvPrintServiceStatusEntry 7 }
        
          bvJobTitle  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..64))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The title of the active print job."
              ::= { bvPrintServiceStatusEntry 8 }
        
          bvJobSize  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..9))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "The size of the active print job."
              ::= { bvPrintServiceStatusEntry 9 }
        
          bvJobNumber  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..4))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                  "The VINES job number of the active print job."
              ::= { bvPrintServiceStatusEntry 10 }
        
          -- the LanMan group
        
          lmGroupVersion OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The version for the lanManger group."
              ::= { lanManager 1 }
        
          lmEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                  "Indicates whether or not the Lan Manager protocol
                  stack is enabled on the print server.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { lanManager 2 }
        
          -- the eTalk group
        
          eTalkGroupVersion OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The version for the eTalk group."
              ::= { eTalk 1 }
        
          eTalkEnabled OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates whether or not the EtherTalk protocol
                   stack is enabled on the print server.
        
                   In order for changes to this variable to take effect,
                   the print server must be reset.  See cmdReset to do
                   this."
              ::= { eTalk 2 }
        
          eTalkRestoreDefaults OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "A value of 2 will restore all EtherTalk parameters on
                   the print server to factory defaults, as well as reset
                   the print server."
              ::= { eTalkCommands 1 }
        
          eTalkNetwork OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (2))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Indicates the EtherTalk network number that the print
                   server is currently using."
              ::= { eTalkConfigure 1 }
        
          eTalkNode OBJECT-TYPE
              SYNTAX  OCTET STRING (SIZE (1))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Indicates the EtherTalk node number that the print
                   server is currently using."
              ::= { eTalkConfigure 2 }
        
          eTalkNumPorts OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Indicates the number of physical output ports that
                   are EtherTalk compatible."
              ::= { eTalkConfigure 3 }
        
          eTalkPortTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF ETalkPortEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "A table of EtherTalk specific port configuration
                   information."
              ::= { eTalkConfigure 4 }
        
          eTalkPortEntry OBJECT-TYPE
              SYNTAX  ETalkPortEntry
              ACCESS  not-accessible
              STATUS  optional
              DESCRIPTION
                   "An entry of EtherTalk port specific information."
              INDEX   { eTalkPortIndex }
              ::= { eTalkPortTable 1 }
        
          ETalkPortEntry ::=
              SEQUENCE {
                  eTalkPortIndex
                      INTEGER,
                  eTalkPortEnable
                      INTEGER,
                  eTalkName
                      DisplayString,
                  eTalkActiveName
                      DisplayString,
                  eTalkType1
                      DisplayString,
                  eTalkType2
                      DisplayString,
                  eTalkZone
                      DisplayString,
                  eTalkActiveZone
                      DisplayString
              }
        
          eTalkPortIndex OBJECT-TYPE
              SYNTAX  INTEGER
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "A unique value for each physical output port which is
                   compatible with EtherTalk.  Its value ranges between
                   1 and the value of eTalkNumPorts.  The value for each
                   port must remain constant at least from one
                   re-initialization of the entity's network management
                   system to the next re-initialization."
              ::= { eTalkPortEntry 1 }
        
          eTalkPortEnable OBJECT-TYPE
              SYNTAX  INTEGER {
                  no(1),
                  yes(2)
              }
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates whether or not the physical output port is
                   enabled to print via EtherTalk and will show up in the
                   Chooser."
              ::= { eTalkPortEntry 2 }
        
          eTalkName  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (1..32))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "This is the EtherTalk name for the print server."
              ::= { eTalkPortEntry 3 }
        
          eTalkActiveName  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (1..32))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "This is the EtherTalk name for the print server
                   that is currently being used."
              ::= { eTalkPortEntry 4 }
        
          eTalkType1  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (1..32))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the first EtherTalk type.  This type is
                   mandatory."
              ::= { eTalkPortEntry 5 }
        
          eTalkType2  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..32))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the second EtherTalk type.  This type is
                   optional.  Setting this name to NULL will disable it."
              ::= { eTalkPortEntry 6 }
        
          eTalkZone  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (1..32))
              ACCESS  read-write
              STATUS  optional
              DESCRIPTION
                   "Indicates the EtherTalk zone.  This must be defined
                   on the router."
              ::= { eTalkPortEntry 7 }
        
          eTalkActiveZone  OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (1..32))
              ACCESS  read-only
              STATUS  optional
              DESCRIPTION
                   "Indicates the EtherTalk zone that is currently being
                   used.  This must be defined on the router."
              ::= { eTalkPortEntry 8 }
        
          eTalkError  OBJECT-TYPE
               SYNTAX  DisplayString (SIZE (0..80))
               ACCESS  read-only
               STATUS  optional
               DESCRIPTION
                    "Shows any errors for the EtherTalk protocol."
               ::= { eTalkStatus 1 }
        
          -- Traps
        
          trapPrinterOnline TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer is on-line.  This trap will be sent
                    out after a printer error condition has been cleared."
                                --#TYPE "Printer On-Line"
                                --#SUMMARY "Port %s is On-Line"
                                --#ARGUMENTS{0}
                                --#SEVERITY INFORMATIONAL
                                --#TIMEINDEX 2
                                --#STATE  OPERATIONAL
               ::= 1
        
          trapPrinterOffline TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer is off-line."
                                --#TYPE "Printer Off-Line"
                                --#SUMMARY "Port %s is Off-Line"
                                --#ARGUMENTS {0}
                                --#SEVERITY INFORMATIONAL
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 2
        
          trapNoPrinterAttached TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "No printer is attached to the output port."
                                --#TYPE "No Printer Attached"
                                --#SUMMARY "Port %s - No Printer Attached"
                                --#ARGUMENTS {0}
                                --#SEVERITY INFORMATIONAL
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 3
        
          trapPrinterTonerLow TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer toner is low."
                                --#TYPE "Toner Low"
                                --#SUMMARY "Port %s - Toner Low"
                                --#ARGUMENTS {0}
                                --#SEVERITY MINOR
                                --#TIMEINDEX 2
                                --#STATE  DEGRADED
               ::= 4
        
          trapPrinterPaperOut TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer is out of paper."
                                --#TYPE "Printer Out of Paper"
                                --#SUMMARY "Port %s - Out of Paper"
                                --#ARGUMENTS {0}
                                --#SEVERITY MINOR
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 5
        
          trapPrinterPaperJam TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer has a paper jam."
                                --#TYPE "Paper Jam"
                                --#SUMMARY "Port %s - Paper Jam"
                                --#ARGUMENTS {0}
                                --#SEVERITY MAJOR
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 6
        
          trapPrinterDoorOpen TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "The printer door is open."
                                --#TYPE "Printer Door Open"
                                --#SUMMARY "Port %s - Printer Door Open"
                                --#ARGUMENTS {0}
                                --#SEVERITY INFORMATIONAL
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 7
        
          trapPrinterError TRAP-TYPE
               ENTERPRISE printServers
               VARIABLES  {outputIndex}
               DESCRIPTION
                    "General printer error."
                                --#TYPE "General Printer Error"
                                --#SUMMARY "Port %s - Printer Error"
                                --#ARGUMENTS {0}
                                --#SEVERITY MINOR
                                --#TIMEINDEX 2
                                --#STATE  NONOPERATIONAL
               ::= 16
                                                                                       

END