OPTIMUX-MIB 	DEFINITIONS ::= BEGIN

--Title:    OPTIMUX   MIB
--
-- Copyright 1993 RAD Data Communications, Ltd.
-- All Rights Reserved.  

-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.

-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.

IMPORTS
	DisplayString	                        FROM RFC1213-MIB
 	enterprises, Counter, IpAddress, TimeTicks	FROM RFC1155-SMI
	OBJECT-TYPE                     	    FROM RFC-1212
	TRAP-TYPE                               FROM RFC-1215
    ifIndex, InterfaceIndex			        FROM IF-MIB
 	dsx1LoopbackStatus 	                	FROM DS1-MIB
	dsx3LoopbackStatus                      FROM DS3-MIB; 

-- Some MIB compilers need those two lines:
-- enterprises OBJECT IDENTIFIER ::=
--                   { iso org(3) dod(6) internet(1) private(4) 1 }



rad OBJECT IDENTIFIER ::= { enterprises 164 }
radWan   OBJECT IDENTIFIER ::= { rad 3 } -- rad WAN Tree
radGen   OBJECT IDENTIFIER ::= { rad 6} -- General information
wanGen   OBJECT IDENTIFIER ::= { radWan 1}

-- 
-- file :v:\doc\rdv\mib\ver440\radgen.txt
-- 

--Version:   4.40
--First Version Date:   16.10.94              
--By:        Orly Nicklass
--File:      radgen.txt

--Last Update:  04.01.99 by Smadar (added OID for DXC30E)


systems OBJECT IDENTIFIER ::= { radGen 1}  --    list of RAD products

radSysTR  OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring 

radRADring    OBJECT IDENTIFIER  ::= { radSysTR  1 }

radTMA  OBJECT IDENTIFIER  ::= { radSysTR  2 }

radRingMonitor    OBJECT IDENTIFIER  ::= { radSysTR  3 }

radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi 

radFDX100  OBJECT IDENTIFIER ::= { radSysFddi  1 } -- RAD Fddi
 
radSysWan OBJECT IDENTIFIER ::= { systems 3 }  -- RAD Wan products

radMP2100      OBJECT IDENTIFIER ::= { radSysWan  1 }
radMP2104      OBJECT IDENTIFIER ::= { radSysWan  2 }
radMP2100B     OBJECT IDENTIFIER ::= { radSysWan  3 }
radMP2100F     OBJECT IDENTIFIER ::= { radSysWan  4 }

radMP2100H      OBJECT IDENTIFIER ::= { radSysWan  5 }
radMP2104H      OBJECT IDENTIFIER ::= { radSysWan  6 }
radMP2200B      OBJECT IDENTIFIER ::= { radSysWan  7 }
radMP2200F      OBJECT IDENTIFIER ::= { radSysWan  8 }

radMX3000       OBJECT IDENTIFIER ::= { radSysWan  9 }
radMX3004       OBJECT IDENTIFIER ::= { radSysWan 10 }
radMX30			OBJECT IDENTIFIER ::= { radSysWan 11 }
radMX300		OBJECT IDENTIFIER ::= { radSysWan 12 }

radKM2100	    OBJECT IDENTIFIER ::= { radSysWan 15 }
radKM2104		OBJECT IDENTIFIER ::= { radSysWan 16 }

radDXC30        OBJECT IDENTIFIER ::= { radSysWan 20 }
radDXC10A       OBJECT IDENTIFIER ::= { radSysWan 21 }
radDXC8R        OBJECT IDENTIFIER ::= { radSysWan 22 }
radDXC30E       OBJECT IDENTIFIER ::= { radSysWan 23 }

radFcdT1        OBJECT IDENTIFIER ::= { radSysWan 30 }
radFcdE1        OBJECT IDENTIFIER ::= { radSysWan 31 }
radFcdE1I       OBJECT IDENTIFIER ::= { radSysWan 32 }

radHtuE1Sa      OBJECT IDENTIFIER ::= { radSysWan 40 }
radHtuE1        OBJECT IDENTIFIER ::= { radSysWan 41 }	 --card
radHtu2Sa       OBJECT IDENTIFIER ::= { radSysWan 42 }
radHtu2         OBJECT IDENTIFIER ::= { radSysWan 43 }	 --card
radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 }
radAsmi450R768  OBJECT IDENTIFIER ::= { radSysWan 45 }	 --card
radAsmi450R1152Sa  OBJECT IDENTIFIER ::= { radSysWan 46 }
radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 }	 --card

radLrs12F        OBJECT IDENTIFIER ::= { radSysWan 48 }
radLrs12B        OBJECT IDENTIFIER ::= { radSysWan 49 }

radHcdE1Sa       OBJECT IDENTIFIER ::= { radSysWan 51 }
radHcdE1         OBJECT IDENTIFIER ::= { radSysWan 52 }  --card
radHtuT1Sa       OBJECT IDENTIFIER ::= { radSysWan 53 }
radHtuT1         OBJECT IDENTIFIER ::= { radSysWan 54 }	 --card

radOptimux4E1         OBJECT IDENTIFIER ::= { radSysWan 55 }
radOptimux4T1         OBJECT IDENTIFIER ::= { radSysWan 56 }
radOptimuxXLE1         OBJECT IDENTIFIER ::= { radSysWan 57 }
radOptimuxXLT1         OBJECT IDENTIFIER ::= { radSysWan 58 }
radOptimuxXL16E1       OBJECT IDENTIFIER ::= { radSysWan 59 }

radImx64        OBJECT IDENTIFIER ::= { radSysWan 60 }
radImx6L        OBJECT IDENTIFIER ::= { radSysWan 61 }
radImxT1E1      OBJECT IDENTIFIER ::= { radSysWan 62 }

radHtuE1SaV2      OBJECT IDENTIFIER ::= { radSysWan 70 }
radHtuE1V2        OBJECT IDENTIFIER ::= { radSysWan 71 }	 --card

 
radSysBRG OBJECT IDENTIFIER ::= { systems 4 }  -- RAD Bridges products

radTRE1  OBJECT IDENTIFIER ::= { radSysBRG 1 }  -- RAD Bridges products

radTRE1D  OBJECT IDENTIFIER ::= { radSysBRG 2 }  -- RAD Bridges products

radTRE8  OBJECT IDENTIFIER ::= { radSysBRG 3 }  -- RAD Bridges products

radTRE8D  OBJECT IDENTIFIER ::= { radSysBRG 4 }  -- RAD Bridges products

radMBE1  OBJECT IDENTIFIER ::= { radSysBRG 5 }  -- RAD Bridges products

radMBE1D  OBJECT IDENTIFIER ::= { radSysBRG  6 }  -- RAD Bridges products

radMBE8  OBJECT IDENTIFIER ::= { radSysBRG  7 }  -- RAD Bridges products

radMBE8D  OBJECT IDENTIFIER ::= { radSysBRG  8 }  -- RAD Bridges products

radMLBT   OBJECT IDENTIFIER ::= { radSysBRG  9 }  -- RAD Bridges products 

radFEB4DAS    OBJECT IDENTIFIER ::= { radSysBRG  10 }  -- RAD Bridges products

radTrimBrg10  OBJECT IDENTIFIER ::= { radSysBRG 11 }  -- RAD Bridges products

radTrimBrg16  OBJECT IDENTIFIER ::= { radSysBRG 12 }  -- RAD Bridges products

radRRTRE8  OBJECT IDENTIFIER ::= { radSysBRG 13 }  -- RAD Bridges products

radRRTRE8D  OBJECT IDENTIFIER ::= { radSysBRG 14 }  -- RAD Bridges products

radRRMLBT   OBJECT IDENTIFIER ::= { radSysBRG 15 }  -- RAD Bridges products 

radRRMLBTF   OBJECT IDENTIFIER ::= { radSysBRG 16 }  -- RAD Bridges products 

radRRTRE1D  OBJECT IDENTIFIER ::= { radSysBRG 17 }  -- RAD Bridges products

radTRERAS  OBJECT IDENTIFIER ::= { radSysBRG 18 }  -- RAD Bridges products

radTRERASa  OBJECT IDENTIFIER ::= { radSysBRG 19 }  -- RAD Bridges products

radMBERAS  OBJECT IDENTIFIER ::= { radSysBRG 20 }  -- RAD Bridges products

radMBERASa  OBJECT IDENTIFIER ::= { radSysBRG 21 }  -- RAD Bridges products
 
radFEB4FDX   OBJECT IDENTIFIER ::= { radSysBRG 22 }  -- RAD Bridges products

radFEB4SAS  OBJECT IDENTIFIER ::= { radSysBRG 23 }  -- RAD Bridges products

radRRFTBDAS  OBJECT IDENTIFIER ::= { radSysBRG 24 }  -- RAD Bridges products

radRRFTBSAS  OBJECT IDENTIFIER ::= { radSysBRG 25 }  -- RAD Bridges products

radFTBDAS    OBJECT IDENTIFIER ::= { radSysBRG 26 }  -- RAD Bridges products

radFTBSAS    OBJECT IDENTIFIER ::= { radSysBRG 27 }  -- RAD Bridges products

radFastWay100    OBJECT IDENTIFIER ::= { radSysBRG 28 }  -- RAD Bridges products

radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 }  -- RAD Converters products

radSTC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 1 }  -- RAD Converters products

radSTC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 3 }  -- RAD Converters products

radSTC1UDP  OBJECT IDENTIFIER ::= { radSysCnvrtr 4 }  -- RAD Converters products

radSTC2UDP  OBJECT IDENTIFIER ::= { radSysCnvrtr 6 }  -- RAD Converters products

radFTC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 10 }  -- RAD Converters products

radFTC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 12 }  -- RAD Converters products

radFTC1UDP    OBJECT IDENTIFIER ::= { radSysCnvrtr 13 }  -- RAD Converters products

radFTC2UDP    OBJECT IDENTIFIER ::= { radSysCnvrtr 15 }  -- RAD Converters products

radSEC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 20 }  -- RAD Converters products

radSEC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 22 }  -- RAD Converters products

radSEC1UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 23 }  -- RAD Converters products

radSEC2UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 25 }  -- RAD Converters products

radFEC1   OBJECT IDENTIFIER ::= { radSysCnvrtr 30 }  -- RAD Converters products

radFEC2   OBJECT IDENTIFIER ::= { radSysCnvrtr 32 }  -- RAD Converters products

radFEC1UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 33 }  -- RAD Converters products

radFEC2UDP   OBJECT IDENTIFIER ::= { radSysCnvrtr 35 }  -- RAD Converters products

radSysStkHub  OBJECT IDENTIFIER ::= { systems 7 }  -- RAD Stackable products

radRBHE    OBJECT IDENTIFIER ::= { radSysStkHub 1 }  -- RAD Stackable products

radRBHT    OBJECT IDENTIFIER ::= { radSysStkHub 2 }  -- RAD Stackable products

radETS4fddiDAS   OBJECT IDENTIFIER ::= { radSysStkHub 3 }  -- RAD Stackable products

radETS4fddiSAS   OBJECT IDENTIFIER ::= { radSysStkHub 4 }  -- RAD Stackable products

radSAHEMX  OBJECT IDENTIFIER ::= { radSysStkHub 5 }  -- RAD Stackable products

radSAHTM   OBJECT IDENTIFIER ::= { radSysStkHub 6 }  -- RAD Stackable products

radETS4   OBJECT IDENTIFIER ::= { radSysStkHub 7 }  -- RAD Stackable products

radSAHEMU  OBJECT IDENTIFIER ::= { radSysStkHub 8 }  -- RAD Stackable products


unknown    	OBJECT IDENTIFIER ::= { radSysStkHub 9 }  -- RAD Stackable products

radSAH16Eint   OBJECT IDENTIFIER ::= { radSysStkHub 10 }  -- RAD Stackable products

radSAH16Tint   OBJECT IDENTIFIER ::= { radSysStkHub 11 }  -- RAD Stackable products

radSAH16Eext   OBJECT IDENTIFIER ::= { radSysStkHub 12 }  -- RAD Stackable products

radSAH16Text   OBJECT IDENTIFIER ::= { radSysStkHub 13 }  -- RAD Stackable products



radSysPS OBJECT IDENTIFIER ::=  { systems 8 } -- RAD Packet Switch  (PS) products 

radSPS2  OBJECT IDENTIFIER ::=  { radSysPS 1 } -- RAD Packet Switch  (PS) products 

radSPS3  OBJECT IDENTIFIER ::=  { radSysPS 2 } -- RAD Packet Switch  (PS) products 

radSPS6  OBJECT IDENTIFIER ::=  { radSysPS 3 } -- RAD Packet Switch  (PS) products 

radSPS9  OBJECT IDENTIFIER ::=  { radSysPS 4 } -- RAD Packet Switch  (PS) products 

radSPS12 OBJECT IDENTIFIER ::=  { radSysPS 5 } -- RAD Packet Switch  (PS) products 

radAPD2  OBJECT IDENTIFIER ::=  { radSysPS 6 } -- RAD Packet Switch  (PS) products 

radAPD8  OBJECT IDENTIFIER ::=  { radSysPS 7 } -- RAD Packet Switch  (PS) products 

radAPS8  OBJECT IDENTIFIER ::=  { radSysPS 8 } -- RAD Packet Switch  (PS) products 

radAPS16 OBJECT IDENTIFIER ::=  { radSysPS 9 } -- RAD Packet Switch  (PS) products 

radAPS24 OBJECT IDENTIFIER ::=  { radSysPS 10 } -- RAD Packet Switch  (PS) products 

radSPS3S  OBJECT IDENTIFIER ::=  { radSysPS 11} -- RAD Packet Switch  (PS) products 

radFPS8  OBJECT IDENTIFIER ::=  { radSysPS 12} -- RAD Packet Switch  (PS) products 

radFPS12  OBJECT IDENTIFIER ::=  { radSysPS 13} -- RAD Packet Switch  (PS) products 

radSPS3ScSL  OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch  (PS) products 

radSPS3Sc2S  OBJECT IDENTIFIER ::=  { radSysPS 15} -- RAD Packet Switch  (PS) products 

radFPS8c OBJECT IDENTIFIER ::=  { radSysPS 16} -- RAD Packet Switch  (PS) products

radFPS4 OBJECT IDENTIFIER ::=  { radSysPS 17} -- RAD Packet Switch  (PS) products


radSysEth  OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products 

radEP8T    OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products

radEP4TAUI   OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products

radEP4T2FL   OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products

radEP4TFL    OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products

radEP4FL     OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products


radEPR8T   OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products

radEPR4TAUI  OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products

radEPR4T2FL  OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products

radEPR4TFL   OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products

radEPR4FL    OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products


radSysRtr  OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products 

radRTED    OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products

radRTEM    OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products

radRTEC    OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products


radSysAtm  OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products 

radStarSwitch    OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products

radStarSwitchATM25    OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products
radStarSwitchATM25L   OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products
radStarSwitchATM155   OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products


radAtmCsuDsu  OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products 

radAmcdE1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products
radAmcdT1  OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products
radAce20E  OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products
radAce20T  OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products

radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005
radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002

radAce2E  OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products
radAce2T  OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products

radAce  OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products 
radAce101  OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101
radAce102  OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102


agnt OBJECT IDENTIFIER ::= { radGen 2} 
-- agent general tree
-- Agent General  
agnHwVersion OBJECT-TYPE
      SYNTAX  DisplayString
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "ASCII string for description and display of the agent hardware version,
      as it is known by the agent software.The user can update the version
       upon request when he changes   components in the agent's module  "
      ::= { agnt 1 }

agnTrapMask OBJECT-TYPE   
      SYNTAX  INTEGER 
      ACCESS  read-write    
      STATUS  mandatory
      DESCRIPTION
      "The value of this attribute determines the type of traps the 
       agent should mask and not send to the management console. The 
       value is differently determined for different products. There are 
       mainly two methods:
       - an integer number, specifying the traps' severity.
       - a sum of 2**n, where n is a bit assigned to a certain 
         masked trap group.
       User should consult the product specification, to find out 
       the method employed."
      ::= { agnt 2 }

agnTrapValue OBJECT-TYPE
	SYNTAX  OCTET STRING
	ACCESS  read-only
	STATUS deprecated
	DESCRIPTION
	"The value of the trap decoded in internal RAD format. Full description is given
	  in the Trap definition file"
	::= {agnt 3}

agnChangeCnt OBJECT-TYPE
	SYNTAX  Counter
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"The number of changes in system configuration that were  reported to the 
	manager since last cold start"
	::= {agnt 4 }

agnSpecific OBJECT-TYPE
      SYNTAX  OBJECT IDENTIFIER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      " Object identifier of entity containing additional information 
      regarding this instance."
      ::= { agnt 5}

agnConfigMsg OBJECT-TYPE   
      SYNTAX  OCTET STRING
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      "Full configuration message  coded in internal RAD application format.
      This entry describes agent's configuration. "
      ::= { agnt 6 }

-- Manager table to record all IP addresses

mngTrapIpTable  OBJECT-TYPE
	SYNTAX  SEQUENCE OF MngEntry
	ACCESS  not-accessible
	STATUS mandatory
	DESCRIPTION
	"This table indicates  the destination address of the traps.
	  Internally it will be limited to ten addresses. "
	::= { agnt 7 }

mngEntry OBJECT-TYPE
	SYNTAX  MngEntry
	ACCESS  not-accessible
	STATUS mandatory
	INDEX {  mngID }
	::= { mngTrapIpTable 1 }


MngEntry  ::=
	    SEQUENCE {
	mngID
	  INTEGER,
	mngIP
	  IpAddress,
	mngIPMask
	  IpAddress,
    mngTrapMask
      INTEGER	
    }

mngID OBJECT-TYPE
	SYNTAX  INTEGER 
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	" This value indicates an index of a specific IP address"
	::= { mngEntry 1 }

mngIP OBJECT-TYPE
	SYNTAX  IpAddress 
	ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
	"This value indicates  the  destination address of the traps. IP 0.0.0.0 removes the entry. "
	::= { mngEntry 2 }

mngIPMask OBJECT-TYPE
	SYNTAX  IpAddress 
	ACCESS  read-write
	STATUS deprecated
	DESCRIPTION
	"This value indicates  the  mask of the destination addresses of the traps. "
	::= { mngEntry 3 }

mngTrapMask OBJECT-TYPE
	SYNTAX  INTEGER 
	ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
      "The value of this attribute determines the type of traps the 
       agent should mask and not send to this NMS. The 
       value is differently determined for different products. There are 
       mainly two methods:
       - an integer number, specifying the traps' severity.
       - a sum of 2**n, where n is a bit assigned to a certain 
         masked trap group.
       User should consult the product specification, to find out 
       the method employed."
	::= { mngEntry 4 }

agnIndication OBJECT-TYPE   
      SYNTAX  INTEGER {
		 faulty (1),        -- critical
		 warning (2),
		 normal(3),			-- off
		 minor(4),
		 major(5),
		 event(6)
     
		}
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      "Attribute describing the state of the entity the agent is responsible for.
       In case of a modular entity, the value of this attribute will be according
       to the component which is in the worst state."
      ::= { agnt 8 }


agnMonitorModeCmd OBJECT-TYPE
	SYNTAX  INTEGER {
	notApplicable(1),
	off(2),
	on(3)
	}
	ACCESS  read-write
	STATUS mandatory
	DESCRIPTION
	"Setting this attribute to ON, will enforce the agent to change its mode of operation to
	 Monitor Mode"
	::= {agnt 9}

agnLed OBJECT-TYPE
	SYNTAX  OCTET STRING
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"This entry specifies  the LEDs status of the agent module . Each led will be represented by 4 
	 bits  where the first 2 bits (left) will specify  the status :
	 (00=NA, 01=OFF, 10=ON, 11=BLINK),
     and the next two bits (right) will specify the color :
     (00=GREEN, 01=RED, 10=YELLOW, 11=ORANGE)"
	::= {agnt 10}

trapTable  OBJECT-TYPE
	SYNTAX  SEQUENCE OF TrapEntry
	ACCESS  not-accessible
	STATUS mandatory
	DESCRIPTION
	"This table includes the last few traps generated by the agent, for future retrieval. The table
	 has a limited capacity. If traps are not retrieved in proper time, they will be
	 over-written by new traps "
	::= {agnt 11}

trapEntry OBJECT-TYPE
	SYNTAX  TrapEntry
	ACCESS  not-accessible
	STATUS mandatory
	INDEX {  trapID }
	::= { trapTable 1 }

TrapEntry  ::=
	    SEQUENCE {
	trapID
	  INTEGER,
	trapVal
	  DisplayString,
	 trapTimeSinceOccurrence
	   TimeTicks
	}

trapID OBJECT-TYPE
	SYNTAX  INTEGER 
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	" This value indicates an index of a specific trap "
	::= { trapEntry 1 }

trapVal OBJECT-TYPE
	SYNTAX  DisplayString 
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"This value is the actual ASCII description  of the trap. "
	::= { trapEntry 2 }

trapTimeSinceOccurrence OBJECT-TYPE
	 SYNTAX    TimeTicks
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"This value indicates the amount of  time passed since the occurrence of the event that
	   trigger this trap. "
	::= { trapEntry 3 }

fileTransfer  OBJECT IDENTIFIER ::= { agnt 12 }

fileServerIP  OBJECT-TYPE
	SYNTAX  IpAddress
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"The IP address of the server from which the file is loaded "
	::= { fileTransfer 1 }

fileName  OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"The name of the file to be loaded. For protection, read returns
	 NULL. "
	::= { fileTransfer 2 }

fileTransCmd  OBJECT-TYPE
	SYNTAX  INTEGER {
	                 swDwnLoad     (1),
					 configDwnLoad (2),
					 configUpLoad  (3),
					 coProcDwnLoad (4),
					 stateUpLoad   (5),
					 noOp          (255)
					}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"The command to be executed on fileName at fileServerIP."
	::= { fileTransfer 3 }
 
-- tftp  group  

tftpRetryTimeOut OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        " General Retransmission time-out value (seconds) "
    -- DEFVAL  { 15 }
    ::= { fileTransfer 4 }

tftpTotalTimeOut OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
        " Total Retransmission time-out value (seconds) "
    -- DEFVAL  { 60 }
    ::= { fileTransfer 5 }

tftpStatus OBJECT-TYPE
    SYNTAX  INTEGER {
		noOp(2),
		connecting(3),
		transferringData(4),
		endedTimeOut(5),
		endedOk(6),
		error(7)
	}
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
    "Status of tftp session. When a session ended with success,
    the tftpStatus should be endedOk(6). Before restarting a
    tftp session, the NMS should set the tftpStatus to noOp(2).
    That's the reason of ACCESS read-write to this field."
    DEFVAL  { noOp}
    ::= { fileTransfer 6 }

tftpError OBJECT-TYPE
    SYNTAX  OCTET STRING ( SIZE(2) )
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
    " The MSB represents the standard error code.
    The LSB represents the private error code.
    0x0000 is No Error
    0x0100 is File Not Found
    0x0400 is Illegal TFTP operation
    0x0500 is Unknown transfer ID
    0x0001 is Server Overflow
    0x0002 is No empty UDP port
    0x0003 is No empty connection
    0x0004 is Illegal File Mode
    0x0007 is Illegal PDU size "
    DEFVAL  { '0000'h }
    ::= { fileTransfer 7 }

fileTransferToSubSystems OBJECT-TYPE
    SYNTAX  OCTET STRING 
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
    " This object represents the sub-systems the fileTransCmd 
      refers to. It should be used when a system is divided 
      to sub-systems and each sub-system (or part of them) can 
	  have a different SW/Configuration.

	  Each bit of this object will represent one of the sub-systems.
	  Bit='1' - APPLY to respective sub-system
	  Bit='0' - DO NOT APPLY to respective sub-system

	  For the meaning of each bit, see product's specification.
	  User will select the sub-systems envolved by filling-in the bits
      that represent these sub-systems.
      In this case, the file represented by 'fileName' will 
	  include several parts, each representing one of the sub-systems.
	  The agent will refer only to the part/s indicated by this object.

      0 Octet Strings = not applicable  
      DEFVAL = 0h	for  the products that support this object."
    ::= { fileTransfer 8 }


systemReset  OBJECT-TYPE
	SYNTAX  INTEGER	{
	                 off         (2),
					 on          (3), --HW
					 resetConfig (4)  
				    }
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION
	"Reset action to be performed on the system."
	::= { agnt 13 }

systemTiming  OBJECT IDENTIFIER ::= { agnt 14 }

systemDate OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
           "System date."
        ::= { systemTiming 1 }
        
systemTime OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
           "System time."
        ::= { systemTiming 2 }


systemPort  OBJECT IDENTIFIER ::= { agnt 15 }

physicalConnectorTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF PhysicalConnectorEntry
	ACCESS  not-accessible
	STATUS mandatory
	DESCRIPTION
	"This table includes the connector type of ports or interfaces."
	::= {systemPort 1}

physicalConnectorEntry OBJECT-TYPE
	SYNTAX  PhysicalConnectorEntry
	ACCESS  not-accessible
	STATUS mandatory
	INDEX {portIdx}
	::= { physicalConnectorTable 1 }

PhysicalConnectorEntry  ::=
	    SEQUENCE {
	portIdx
	  INTEGER,
	physicalConnector
	  INTEGER
	}

portIdx OBJECT-TYPE
	SYNTAX  INTEGER 
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"This object is an index of the specific port or interface.
	 For a port, the index will be as agreed between agent and 
	 application.
	 For an interface, ifIndex may be used."
	::= { physicalConnectorEntry 1 }

physicalConnector OBJECT-TYPE
	SYNTAX  INTEGER 
	        {
			other (1),
			v35   (2),	  --34 pin female
			rs530 (3),	  --DB25
			x21   (4),	  --DB15
			bnc   (5),
			utp   (6),	  --RJ45
			aui   (7),
			rs422 (8),	  --DB25
			crossUtp (9), --RJ45
			rj45    (10),
			v24     (11), --DB25
			g703    (12), --TB5
			termBlock3AndRj45 (13),
			terminalBlock3    (14),
			terminalBlock5    (15),
			terminalBlock7    (16),
			db25              (17),
			db15              (18),
			rj45ethernet      (19),
			termBlock5AndRj45 (20),
			db9               (21),
			g703E1            (22),  --BNC-RJ45-BNC	
			g703E1-LTU        (23),  --BNC-RJ45-BNC
			sc                (24),	 --sc optical 
			st                (25),	 --st optical
			stl               (26),
			fc                (27),	 --fc optical
			tb5w              (28),  --Term-Block-5-Wire (for HCD)
			termBlock6AndRj45 (29),

			none             (255)    	
			}	 
	ACCESS  read-only
	STATUS mandatory
	DESCRIPTION
	"The connector of the port/interface.
	 other - none of the specified connectors
	 none -  no connector."
	::= { physicalConnectorEntry 2 }


prtSupervisory  OBJECT IDENTIFIER ::= { systemPort 2 }


prtSpTable OBJECT-TYPE
      SYNTAX SEQUENCE OF PrtSpEntry
      ACCESS not-accessible
      STATUS  mandatory
      ::= {prtSupervisory 1}

prtSpEntry OBJECT-TYPE
      SYNTAX PrtSpEntry
      ACCESS not-accessible
      STATUS mandatory
      DESCRIPTION
      "Supervisory port parameter table."
      INDEX {prtSupervisoryIndex }
      ::= { prtSpTable 1}

PrtSpEntry ::=
      SEQUENCE {
      prtSupervisoryIndex       INTEGER,
	  prtSupervisoryRate        INTEGER,
	  prtSupervisoryDataBits    INTEGER,
	  prtSupervisoryParity      INTEGER,
	  prtSupervisoryStopBits    INTEGER,
	  prtSupervisoryUsage       INTEGER,
	  prtSupervisoryInterface   INTEGER,
	  prtSupervisoryCTS		    INTEGER,
	  prtSupervisoryDcdDelay    INTEGER,
	  prtSupervisoryDSR		    INTEGER
      }				  
					  

prtSupervisoryIndex OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      "The SP port index. 
       The LS byte of the integer is the port index 1..255. 
       The MS byte is different than 0 only if the port belongs to 
       a module. In	that case it is the module number."
      ::= { prtSpEntry 1}

prtSupervisoryRate     OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        auto      (1),
        s300bps   (2),
        s1200bps  (3),
        s2400bps  (4),
        s4800bps  (5),
        s9600bps  (6),
        s19200bps (7),
        s38400bps (8),
        s57600bps (9),
        s115200bps (10)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the operation rate (speed) of the 
       port.
       auto - automatic rate selection, by the agent."
      ::= { prtSpEntry 2}

prtSupervisoryDataBits OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        dataBits7 (1),
        dataBits8 (2)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the number of data bits in an async 
       frame"
      ::= { prtSpEntry 3}

prtSupervisoryParity OBJECT-TYPE
      SYNTAX  INTEGER
	      {
        none  (1),
        odd   (2),
        even  (3)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the parity mode in an async frame"
      ::= { prtSpEntry 4}

prtSupervisoryStopBits OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		notApplicable  (1),
        stopBits1      (2),
        stopBits1dot5  (3),
        stopBits2      (4)
	      }
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the parity mode in an async frame."
      ::= { prtSpEntry 5}

prtSupervisoryUsage OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		unknown (1),
		noUse   (2),
		terminal(3),
		nmsSlip (4),
		nmsPpp  (5),
		muxSlip (6),
		muxPpp  (7),
		dialOut (8)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the usage of the SP port."
      ::= { prtSpEntry 6}

prtSupervisoryInterface OBJECT-TYPE
      SYNTAX  INTEGER
	      {
		  notApplicable(1),
          dce  (2),
          dte  (3)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This attribute indicates the supervisory port interface."
      ::= { prtSpEntry 7}

prtSupervisoryCTS OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          	notApplicable   (1),
          	on            	(2),        --Old value for DCE.
			rts           	(3),        --Old value for DCE 
			dteWait         (4),        --DTE will wait for CTS to become active before transmit date.
			dteIgnore       (5)         --DTE will Ignore CTS signal and will transmit date anyway.
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
	  "CTS line state." 
      ::= { prtSpEntry 8}

prtSupervisoryDcdDelay OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notApplicable (1),
          d0   (2),
          d10  (3),
		  d50  (4),
		  d100 (5),
		  d200 (6),
		  d300 (7)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
	  "DCD delay in msec." 
      ::= { prtSpEntry 9}

prtSupervisoryDSR OBJECT-TYPE
      SYNTAX  INTEGER
	      {
          notApplicable (1),
          on   (2),
          dtr  (3)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
	  "DSR line state." 
      ::= { prtSpEntry 10}

systemResetAllStatsCmd OBJECT-TYPE
      SYNTAX   INTEGER
	      {
    		off(2),
	    	on (3)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
       "Reset statistics of all ports and connections of the device."
      ::= { agnt 16 }

systemClearTablesCmd OBJECT-TYPE
      SYNTAX   INTEGER
	      {
    		off(2),
	    	tempCnfgTables (3)
	      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
       "tempCnfgTables - Set *RowStatus = destroy for all entries of 
                         some tables having *RowStatus object, for 
                         temporary configuration only! (255).
                         For the relevant tables, see product's specification.
                         This object should be used by WAN product applications 
                         before performing the Update operation, in order to clear 
                         old entries of these tables. 
        off - agent will automatically change to this value, after performing the 
              command. "
      ::= { agnt 17 }

systemParameter OBJECT-TYPE
      SYNTAX   INTEGER
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
       "Protocol indication parameter. This parameter can be used for
        different purposes: 
        - TELNET session time-out in seconds."
       ::= { agnt 18 }

agnGlobalAlarmMask OBJECT-TYPE   
      SYNTAX OCTET STRING 
      ACCESS  read-write    
      STATUS  mandatory
      DESCRIPTION
      "The value of this attribute determines the alarm traps the 
       agent should mask and not send to the managers.
       Each bit from a certain octet represents a certain alarm."
      ::= { agnt 19 }

alarmSeverity   OBJECT-TYPE
      	SYNTAX   INTEGER
	      	{
			event		(3),
			minor		(4),
			major		(5),
	    	warning		(6),
			critical	(7)
	  		}
      	ACCESS  read-only
      	STATUS  mandatory
      	DESCRIPTION
       	"This object specifies the severity of the alarms."
      ::= { agnt 20 }

alarmState   OBJECT-TYPE
      	SYNTAX   INTEGER
	      	{
			off (2), 	-- End, 
			on  (3) 	-- Start.
	  		}
      	ACCESS  read-only
      	STATUS  mandatory
      	DESCRIPTION
       "."
      ::= { agnt 21 }

 
agnTestStatus OBJECT-TYPE
	SYNTAX	INTEGER
		{
		 off			(2),
		 on 			(3)
		}

	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
	"Indicates the current test status (for all levels: system,
	   card, port).
       This attribute will be set to: 
         on(3): when there is at least one test	in progress on the
                system/card/port
		 off(2): when there is NO test in progress on the
		         system/card/port"
    ::= {agnt 22  }


tftpStatusChangeTrap  TRAP-TYPE
     ENTERPRISE      systems
     VARIABLES       { tftpStatus}
     DESCRIPTION     
     "This trap is sent whenever the status of tftp changed."
     ::= 1


agnStatusChangeTrap  TRAP-TYPE
	ENTERPRISE		systems
	VARIABLES		{agnIndication}
	DESCRIPTION
	"This trap is sent whenever the state of the entity the agent is
	 responsible for is changed.
	 TDM devices will send agnTestStatus variable to indicate the current test status."
	::= 2


optimux OBJECT IDENTIFIER ::= { radWan 5 }

-- One Optimux is always connected to another optimux 
-- via its link. Therefore, the SNMP agent sitting on
-- one device is responsible of the second (remote)
-- device. This table supplies information for the both
-- optimux, while the first is the local one and the second
-- is the remote one.

optMxConfigTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF OptMxConfigEntry
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
        "This table contains parameters of configuration
	for each member of the couple of Optimux."
     ::= { optimux 1 }

 optMxConfigEntry OBJECT-TYPE
     SYNTAX OptMxConfigEntry 
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
         "An entry in the Optimux Config  table."
     INDEX   { optIndex }
     ::= { optMxConfigTable 1 }

     OptMxConfigEntry ::=
              SEQUENCE {
                  optIndex   		INTEGER,
	     optHWVersion           DisplayString,
 	     optSWVersion           DisplayString,
                  optPSPrimary 		INTEGER,
	     optPSSecondary 	INTEGER,
	     optLinkActive       	InterfaceIndex,
	     optSelectLink       	INTEGER,
	     optGrpPayLoadLoop    INTEGER,
	     optGrpClockSource      INTEGER,
	     optRedundancyStatus   INTEGER,
	     optRedundancyCnf       INTEGER 
      }

 optIndex OBJECT-TYPE
 SYNTAX  INTEGER {local(1), remote(2) }
 ACCESS  read-only
 STATUS  mandatory
 DESCRIPTION
 "optIndex = 1 is for local Optimux.
  optIndex = 2 is for remote Optimux."
  ::= { optMxConfigEntry 1 }

 optHWVersion OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "HW Version of the device."
     ::= { optMxConfigEntry 2 }

optSWVersion OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "SW Version of the device."
     ::= { optMxConfigEntry 3 }

optPSPrimary OBJECT-TYPE
    SYNTAX  INTEGER {
		unknown(1),
		fault(3),
		active(4),
		none(6)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "The status of the primary Power Supply Unit."
    DEFVAL { active }
     ::= { optMxConfigEntry 4 }

optPSSecondary OBJECT-TYPE
     SYNTAX  INTEGER {
		unknown(1),
		fault(3),
		active(4),
		none(6)
      }
     ACCESS  read-only
     STATUS  mandatory
     DESCRIPTION
     "The status of the secondary Power Supply Unit."
     DEFVAL { none }
              ::= { optMxConfigEntry 5 }

optLinkActive OBJECT-TYPE
     SYNTAX  InterfaceIndex
     ACCESS  read-only
     STATUS  mandatory
     DESCRIPTION
     "This object indicates which link is active. It
       may be: 5, 6 or 105, 106" 
      ::= { optMxConfigEntry 6 }

optSelectLink OBJECT-TYPE
     SYNTAX  INTEGER {
		autoredundancy(1),
		main(5),
		back(6)
     }
     ACCESS  read-write
     STATUS   mandatory
     DESCRIPTION
     "This mib item enables the user to force the device
       to use specific link. "
      DEFVAL { autoredundancy }
      ::= { optMxConfigEntry 7 }

optGrpPayLoadLoop OBJECT-TYPE
     SYNTAX  INTEGER {
		off(2), on(3)
     }
     ACCESS  read-write
     STATUS   mandatory
     DESCRIPTION
    	"Performs payload loop ( remote loop) to 4 E1 channels
           at once."
      DEFVAL { off }
      ::= { optMxConfigEntry 8 }

optGrpClockSource OBJECT-TYPE
     SYNTAX  INTEGER {
	notApplicable(1), localInternal(2), localExternal(3),loopTiming(4)
     }
     ACCESS  read-write
     STATUS   mandatory
     DESCRIPTION
     "If dsx3TransmitClockSource = localTiming(2), then the user
      can configure this field as:
      localInternal(2) = use the internal clock of the device
      localExternal(3) = use the external clock connected to the port
      dedicated to clock."
      DEFVAL { notApplicable }
      ::= { optMxConfigEntry 9 }


optRedundancyStatus OBJECT-TYPE
     SYNTAX  INTEGER {
	  available(2), notAvailable(3)
     }
     ACCESS  read-only
     STATUS   mandatory
     DESCRIPTION
     "If there are two modules 'links', then this field
      should be set to available(2). If there is only one
      module 'link', this field should be set to notAvailable(3)."
      DEFVAL { available }
      ::= { optMxConfigEntry 10 }

optRedundancyCnf  OBJECT-TYPE
     SYNTAX  INTEGER {
	off(2), auto(3), manual(4)
     }
     ACCESS  read-write
     STATUS   mandatory
     DESCRIPTION
     "If optRedundancyStatus = notAvailable(3), then this field
       is off(2). Else the user can configure this field as:
      auto(3) = switch back to main link when valid.
      manual(4) = don't switch back to main link. "
      DEFVAL { auto }
      ::= { optMxConfigEntry 11 }

-- This table is for XL Optimux
optMxModuleTable OBJECT-TYPE
     SYNTAX  SEQUENCE OF OptMxModuleEntry
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
        "This table defines the type of the module
      enrolled in each slot."
     ::= { optimux 2 }

 optMxModuleEntry OBJECT-TYPE
     SYNTAX OptMxModuleEntry 
     ACCESS  not-accessible
     STATUS  mandatory
     DESCRIPTION
         "An entry in the Optimux Module  table."
     INDEX   { optMdIdx, optMdSltIdx }
     ::= { optMxModuleTable 1 }

 OptMxModuleEntry ::=
              SEQUENCE {
 		optMdIdx	    INTEGER,
	 	optMdSltIdx 	INTEGER,
 		optMdType 	    INTEGER,
	    optMdHWVersion  DisplayString,
	    optMdModLed 	OCTET STRING 
      }

 optMdIdx OBJECT-TYPE
 SYNTAX  INTEGER {local(1), remote(2) }
 ACCESS  read-only
 STATUS  mandatory
 DESCRIPTION
 " optMdIdx = 1 is for local Optimux.
 optMdIdx = 2 is for remote Optimux."
  ::= { optMxModuleEntry 1 }

 optMdSltIdx OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "Slot A = 1, Slot B = 2, Slot C = 3, Slot D = 4,
      Slot Link = 5, Slot BU = 6 ."
     ::= { optMxModuleEntry 2 }

optMdType OBJECT-TYPE
    SYNTAX  INTEGER {
		unknown(1),
		noModule(2),
		e3linkCX34(3),
		e3linkOPT1(4),
		t3linkOPT1(5),
		eth1Port(6),
		e1FourUTP(7),
		e1TwoPort(8),
		e1TwoUB(9),
		t1FourPort(10),
		t1TwoPort(11),
		e1FourRJ45(12),  -- special for XL/16
		e1FourBNC(13),   -- special for XL/16
		e1FourMiniBNC(14),
		sfLink(15),      -- single fiber
		stationClk(16)   -- not for XL/T1
	}
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "Module Type and number of connectors."
     ::= { optMxModuleEntry 3 }

optMdHWVersion OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "HW Version of the module."
     ::= { optMxModuleEntry 4 }

optMdModLed OBJECT-TYPE
    SYNTAX  OCTET STRING
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
     "The meaning of each bit depends on the module type."
     ::= { optMxModuleEntry 5 }

-- Traps
optMxConfigChange TRAP-TYPE
      ENTERPRISE  optimux
      VARIABLES  {optIndex,  agnLed }
      DESCRIPTION
	  "The trap is sent every time there is a change in
	   the state of one of the PS.."
      ::= 1

optMxAgentFault TRAP-TYPE
      ENTERPRISE  optimux
      VARIABLES  {agnIndication,  agnLed }
      DESCRIPTION
	  "The trap is sent every time there is a change in
	   the agnIndication variable."
      ::= 2

optLineStatusChange TRAP-TYPE
      ENTERPRISE  optimux
      VARIABLES { dsx1LineStatus,
                        dsx1LineStatusLastChange }
	  DESCRIPTION
      "optLineStatusChange trap is sent when the value of an instance 
       dsx1LineStatus changes. It can be utilized by an NMS to trigger polls.
       When the line status change results from a higher level line status 
       change (i.e. ds3), then no traps for the ds1 are sent."
      ::= 3

optSlotChange TRAP-TYPE
      ENTERPRISE  optimux
        VARIABLES { optMdIdx, optMdSltIdx }
--         STATUS  current
         DESCRIPTION
         "This trap alerts the console if there is module
          enrollement/de-enrollement "
         ::= 4

optLoopbackStatusChange TRAP-TYPE
      ENTERPRISE  optimux
        VARIABLES { ifIndex, dsx1LoopbackStatus, dsx3LoopbackStatus }
--         STATUS  current
         DESCRIPTION
         "This trap alerts the console if there is changes in the
         loopback status of some of the line."
                 ::= 5

optXlLineStatusChange TRAP-TYPE
      ENTERPRISE  optimux
      VARIABLES { ifIndex,  optMdModLed, dsx1LineStatus, dsx3LineStatus }
      DESCRIPTION
       "optXlLineStatusChange trap is sent when the value of an instance 
        dsx1LineStatus changes. It can be utilized by an NMS to trigger polls."
      ::= 6


-- 
-- file :v:\doc\rdv\mib\ver435\ethif.txt
-- 
--25/03/97
--By: Smadar Tauber
--File:      s:\doc\rdv\mib\ver435\ethIf.txt


--EthIf MIB - special for DXC-30 v2.3, v2.4

diverseIfWanGen	OBJECT IDENTIFIER ::= {wanGen 6}


--
-- diverseIf - diverse NON-WAN interfaces of WAN products 	
--

--Ethernet Interface

ethIf	OBJECT IDENTIFIER ::= {diverseIfWanGen 1}

ethIfTable OBJECT-TYPE
      SYNTAX SEQUENCE OF EthIfEntry
      ACCESS not-accessible
      STATUS  mandatory
      ::= { ethIf 1}

ethIfEntry OBJECT-TYPE
      SYNTAX EthIfEntry
      ACCESS not-accessible
      STATUS mandatory
      INDEX {ethIfIdx}
      ::= {ethIfTable 1}

EthIfEntry ::=
      SEQUENCE {
      ethIfIdx                INTEGER,
      ethMode                 INTEGER,
      ethBridgingMode         INTEGER
      }

ethIfIdx     OBJECT-TYPE
      SYNTAX  INTEGER
      ACCESS  read-only
      STATUS  mandatory
      DESCRIPTION
      "A unique index of the ethernet interface/port."
      ::=  {ethIfEntry 1}

ethMode    OBJECT-TYPE
      SYNTAX  INTEGER
        {
		  halfDuplex  (1),
          fullDuplex  (2)
	    }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This object indicates the Ethernet mode of operation."
      ::=  {ethIfEntry 2}

ethBridgingMode  OBJECT-TYPE
      SYNTAX  INTEGER
      {
         filtered    (1),
         transparent (2)
      }
      ACCESS  read-write
      STATUS  mandatory
      DESCRIPTION
      "This object indicates the bridging mode of the Ethernet
       interface. "
      ::=  {ethIfEntry 3}